974 resultados para four-dimensional computed tomography
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
PURPOSE: Fatty liver disease (FLD) is an increasing prevalent disease that can be reversed if detected early. Ultrasound is the safest and ubiquitous method for identifying FLD. Since expert sonographers are required to accurately interpret the liver ultrasound images, lack of the same will result in interobserver variability. For more objective interpretation, high accuracy, and quick second opinions, computer aided diagnostic (CAD) techniques may be exploited. The purpose of this work is to develop one such CAD technique for accurate classification of normal livers and abnormal livers affected by FLD. METHODS: In this paper, the authors present a CAD technique (called Symtosis) that uses a novel combination of significant features based on the texture, wavelet transform, and higher order spectra of the liver ultrasound images in various supervised learning-based classifiers in order to determine parameters that classify normal and FLD-affected abnormal livers. RESULTS: On evaluating the proposed technique on a database of 58 abnormal and 42 normal liver ultrasound images, the authors were able to achieve a high classification accuracy of 93.3% using the decision tree classifier. CONCLUSIONS: This high accuracy added to the completely automated classification procedure makes the authors' proposed technique highly suitable for clinical deployment and usage.
Resumo:
contribuindo para o aumento da gordura abdominal, e consequentes complicações metabólicas. O exercício físico permite quebrar este ciclo através da estimulação da lipólise e da utilização de ácidos gordos. Objetivo: Verificar os efeitos de um programa de exercícios no domicílio, em indivíduos com doença arterial coronária, na composição corporal, gordura abdominal, perfil lipídico, glicose, e nível de atividade física. Métodos: Estudo experimental composto por 20 indivíduos, aleatorizados grupo experimental (GE) e grupo de controlo (GC), ambos com 10, tendo o GE sido sujeito ao programa durante 8 semanas. Realizou-se uma avaliação inicial e final, através da bioimpedância, Tomografia Computorizada (TC) abdominal, perimetria, adipometria, análises sanguíneas e acelerómetro. Resultados: Numa análise intergrupal, verificouse uma diminuição da percentagem (%) de gordura total (GT) calculado pela adipometria (p<0.01), na prega supra-ilíaca (p=0.005), na prega abdominal horizontal (p=0.001) e vertical (p=0.003) no GE, e da % de tempo em atividades moderadas no GC (p=0.035). Após 8 semanas o GE diminuiu a %GT (p=0.008); a massa gorda (MG) (p=0.002); perímetro abaixo da última costela (p=0.037) e acima das cristas-ilíacas (p=0.021); %GT calculado (p=0.002); pregas supra-ilíaca (p=0.008), abdominal horizontal (p=0.002) e vertical (p=0.033); TC abdominal subcutâneo (p=0.031) e %de tempo em atividades vigorosas (p=0.031). O GC diminuiu a %GT (p=0.002) e MG (p=0.008); aumentou o perímetro ao nível dos grandes trocânteres (p=0.008), diminuiu o rácio cintura/anca (p=0.002), e a %de tempo em atividades moderadas (p=0.031) e vigorosas (p=0.008). Parece existir uma tendência no GE para diminuição do rácio cintura/anca, c-LDL, triglicerídeos e aumento do nível de atividade moderado. Conclusão: O programa de exercícios no domicílio demonstrou uma diminuição da gordura abdominal, alteração da composição corporal, e parece promover uma melhoria no perfil lipídico e no aumento do nível de atividade física moderado.
Resumo:
Trabalho de Projeto para obtenção do grau de Mestre em Engenharia Informática e de Computadores
Resumo:
8th International Technology, Education and Development Conference, Valencia 10th, 11th and 12th of March, 2014.
Resumo:
Introdução – Os estudos Gated – Single Photon Emission Computed Tomography (SPECT) são uma das técnicas de imagiologia cardíaca que mais evoluiu nas últimas décadas. Para a análise das imagens obtidas, a utilização de softwares de quantificação leva a um aumento da reprodutibilidade e exatidão das interpretações. O objetivo deste estudo consiste em avaliar, em estudos Gated-SPECT, a variabilidade intra e interoperador de parâmetros quantitativos de função e perfusão do miocárdio, obtidos com os softwares Quantitative Gated SPECT (QGS) e Quantitative Perfusion SPECT (QPS). Material e métodos – Recorreu-se a uma amostra não probabilística por conveniência de 52 pacientes, que realizaram estudos Gated-SPECT do miocárdio por razões clínicas e que integravam a base de dados da estação de processamento da Xeleris da ESTeSL. Os cinquenta e dois estudos foram divididos em dois grupos distintos: Grupo I (GI) de 17 pacientes com imagens com perfusão do miocárdio normal; Grupo II (GII) de 35 pacientes que apresentavam defeito de perfusão nas imagens Gated-SPECT. Todos os estudos foram processados 5 vezes por 4 operadores independentes (com experiência de 3 anos em Serviços de Medicina Nuclear com casuística média de 15 exames/semana de estudos Gated-SPECT). Para a avaliação da variabilidade intra e interoperador foi utilizado o teste estatístico de Friedman, considerando α=0,01. Resultados e discussão – Para todos os parâmetros avaliados, os respectivos valores de p não traduziram diferenças estatisticamente significativas (p>α). Assim, não foi verificada variabilidade intra ou interoperador significativa no processamento dos estudos Gated-SPECT do miocárdio. Conclusão – Os softwares QGS e QPS são reprodutíveis na quantificação dos parâmetros de função e perfusão avaliados, não existindo variabilidade introduzida pelo operador.
Resumo:
Introdução – A tomografia de emissão de fotão simples sincronizada com o sinal eletrocardiográfico (Gated-SPECT) é essencial para a avaliação conjunta da perfusão e da função ventricular esquerda (VE) do miocárdio. Objetivo – Investigar a relação entre a função VE e o índice de captação (IC) miocárdio/pulmão direito (M/PD) e M/P esquerdo (M/PE) nos estudos Gated-SPECT com 99mTc-Tetrofosmina. Metodologia – Amostra de 32 pacientes que realizaram estudos Gated-SPECT por indicação clínica, sendo subdividida em dois grupos: Grupo I (GI) – pacientes com a informação clínica de enfarte agudo do miocárdio (EAM); Grupo II (GII) – pacientes com a informação clínica de isquemia. Por cada paciente adquiriram-se imagens estáticas torácico-abdominais e dois estudos Gated-SPECT do miocárdio (protocolo de um dia esforço/repouso). Nas imagens estáticas
definiram-se regiões de interesse (Regions of interest – ROI) para calcular os IC. Nos estudos Gated-SPECT utilizou-se o software Quantitative Gated SPECT/Quantitative Perfusion SPECT para calcular a Fração de Ejeção do Ventrículo Esquerdo (FEVE). Efetuou-se análise estatística descritiva para caracterização da amostra. Aplicou-se o teste de Spearman para avaliar a correlação entre a FEVE e os IC por grupo de pacientes. O Teste de Willcoxon foi usado para comparar FEVE em repouso e em esforço. Resultados – Nos estudos Gated-SPECT em esforço não se verificou correlação estatisticamente significativa entre a FEVE e os IC, para GI e GII; em repouso existe correlação positiva estatisticamente significativa entre a FEVE e os IC, para GI; para GII não se verificou correlação. Na comparação dos valores de FEVE em esforço e repouso nos dois grupos constatou-se a existência de diferenças estatisticamente significativas, sendo a FEVE em Esforço
Resumo:
Radiotherapy (RT) is one of the most important approaches in the treatment of cancer and its performance can be improved in three different ways: through the optimization of the dose distribution, by the use of different irradiation techniques or through the study of radiobiological initiatives. The first is purely physical because is related to the physical dose distributiuon. The others are purely radiobiological because they increase the differential effect between the tumour and the health tissues. The Treatment Planning Systems (TPS) are used in RT to create dose distributions with the purpose to maximize the tumoral control and minimize the complications in the healthy tissues. The inverse planning uses dose optimization techniques that satisfy the criteria specified by the user, regarding the target and the organs at risk (OAR’s). The dose optimization is possible through the analysis of dose-volume histograms (DVH) and with the use of computed tomography, magnetic resonance and other digital image techniques.
Resumo:
Agências financiadoras: National Natural Science Foundation of China - 61204077; Shenzhen Science and Technology Innovation Commission - JCYJ20120614150521967
Resumo:
Atualmente a Tomografia Computorizada (TC) é o método de imagem que mais contribui para a dose coletiva resultante de exposições médicas. Este estudo pretende determinar os valores de Índice de Dose de TC (CTDI) e produto dose-comprimento (DLP) para os exames de crânio e tórax em adultos num equipamento de TC multidetetores; e efetuar uma análise objetiva e subjetiva da qualidade da imagem. Determinaram-se os valores de CTDI e DLP utilizando uma câmara de ionização e fantomas de crânio e tórax. Efetuou-se ainda uma análise objetiva e subjetiva da qualidade da imagem com o fantoma Catphan® 500 e observadores, respetivamente. Os resultados obtidos foram superiores relativamente às Guidelines europeias no protocolo de crânio (CTDIvol = 80,13 mGy e DLP = 1209,22 mGy.cm) e inferiores no protocolo de tórax (CTDIvol = 8,37 mGy e DLP = 274,71 mGy.cm). Na análise objetiva da qualidade da imagem, à exceção da resolução de baixo contraste no protocolo de crânio, todos os outros critérios analisados estavam em conformidade com a legislação. Na análise subjetiva da qualidade da imagem existiu uma diferença estatisticamente significativa entre as classificações atribuídas pelos observadores às imagens nos parâmetros avaliados (p = 0,000-0,005).
Resumo:
Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde- Ramo de especialização: Terapia com Radiações
Resumo:
Mestrado em Intervenção Sócio-Organizacional em Saúde - Ramo de especialização: Políticas de Administração e Gestão de Serviços de Saúde
Resumo:
Medical imaging is a powerful diagnostic tool. Consequently, the number of medical images taken has increased vastly over the past few decades. The most common medical imaging techniques use X-radiation as the primary investigative tool. The main limitation of using X-radiation is associated with the risk of developing cancers. Alongside this, technology has advanced and more centres now use CT scanners; these can incur significant radiation burdens compared with traditional X-ray imaging systems. The net effect is that the population radiation burden is rising steadily. Risk arising from X-radiation for diagnostic medical purposes needs minimising and one way to achieve this is through reducing radiation dose whilst optimising image quality. All ages are affected by risk from X-radiation however the increasing population age highlights the elderly as a new group that may require consideration. Of greatest concern are paediatric patients: firstly they are more sensitive to radiation; secondly their younger age means that the potential detriment to this group is greater. Containment of radiation exposure falls to a number of professionals within medical fields, from those who request imaging to those who produce the image. These staff are supported in their radiation protection role by engineers, physicists and technicians. It is important to realise that radiation protection is currently a major European focus of interest and minimum competence levels in radiation protection for radiographers have been defined through the integrated activities of the EU consortium called MEDRAPET. The outcomes of this project have been used by the European Federation of Radiographer Societies to describe the European Qualifications Framework levels for radiographers in radiation protection. Though variations exist between European countries radiographers and nuclear medicine technologists are normally the professional groups who are responsible for exposing screening populations and patients to X-radiation. As part of their training they learn fundamental principles of radiation protection and theoretical and practical approaches to dose minimisation. However dose minimisation is complex – it is not simply about reducing X-radiation without taking into account major contextual factors. These factors relate to the real world of clinical imaging and include the need to measure clinical image quality and lesion visibility when applying X-radiation dose reduction strategies. This requires the use of validated psychological and physics techniques to measure clinical image quality and lesion perceptibility.
Resumo:
Introdução – O melanoma maligno cutâneo (MMC) é considerado uma das mais letais neoplasias e no seu seguimento recorre-se, para além dos exames clínicos e da análise de marcadores tumorais, a diversos métodos imagiológicos, como é o exame Tomografia por Emissão de Positrões/Tomografia Computorizada (PET/CT, do acrónimo inglês Positron Emission Tomography/Computed Tomography) com 18fluor-fluorodeoxiglucose (18F-FDG). O presente estudo tem como objetivo avaliar a utilidade da PET/CT relativamente à análise da extensão e à suspeita de recidiva do MMC, comparando os achados imagiológicos com os descritos em estudos CT. Metodologia – Estudo retrospetivo de 62 estudos PET/CT realizados em 50 pacientes diagnosticados com MMC. Excluiu-se um estudo cujo resultado era duvidoso (nódulo pulmonar). As informações relativas aos resultados dos estudos anatomopatológicos e dos exames imagiológicos foram obtidas através da história clínica e dos relatórios médicos dos estudos CT e PET/CT. Foi criada uma base de dados com os dados recolhidos através do software Excel e foi efetuada uma análise estatística descritiva. Resultados – Dos estudos PET/CT analisados, 31 foram considerados verdadeiros positivos (VP), 28 verdadeiros negativos (VN), um falso positivo (FP) e um falso negativo (FN). A sensibilidade, especificidade, o valor preditivo positivo (VPP), o valor preditivo negativo (VPN) e a exatidão da PET/CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 96,9%, 96,6%, 96,9%, 96,6% e 96,7%. Dos resultados da CT considerados na análise estatística, 14 corresponderam a VP, 12 a VN, três a FP e cinco a FN. A sensibilidade, especificidade, o VPP e o VPN e a exatidão da CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 73,7%, 80,0%, 82,4%, 70,6% e 76,5%. Comparativamente aos resultados CT, a PET/CT permitiu uma mudança na atitude terapêutica em 23% dos estudos. Conclusão – A PET/CT é um exame útil na avaliação do MMC, caracterizando-se por uma maior acuidade diagnóstica no estadiamento e na avaliação de suspeita de recidiva do MMC comparativamente à CT isoladamente.