946 resultados para etch-and-rinse adhesive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The usage of multi material structures in industry, especially in the automotive industry are increasing. To overcome the difficulties in joining these structures, adhesives have several benefits over traditional joining methods. Therefore, accurate simulations of the entire process of fracture including the adhesive layer is crucial. In this paper, material parameters of a previously developed meso mechanical finite element (FE) model of a thin adhesive layer are optimized using the Strength Pareto Evolutionary Algorithm (SPEA2). Objective functions are defined as the error between experimental data and simulation data. The experimental data is provided by previously performed experiments where an adhesive layer was loaded in monotonically increasing peel and shear. Two objective functions are dependent on 9 model parameters (decision variables) in total and are evaluated by running two FEsimulations, one is loading the adhesive layer in peel and the other in shear. The original study converted the two objective functions into one function that resulted in one optimal solution. In this study, however, a Pareto frontis obtained by employing the SPEA2 algorithm. Thus, more insight into the material model, objective functions, optimal solutions and decision space is acquired using the Pareto front. We compare the results and show good agreement with the experimental data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To compare soft-tissue dissolution by sodium hypochlorite, with an EDTA intermediate rinse, with or without activation with passive ultrasonic activation (PUI) or sonic activation using the Endoactivator (EA) or Eddy tips (ED). Methodology: The root canals of eighty-three human maxillary central incisors were chemo-mechanically prepared and the teeth split. A standardized longitudinal intracanal groove was created in one of the root halves. Eighty-three porcine palatal mucosa samples were collected, adapted to fit into the grooves and weighed. The re-assembled specimens were randomly divided into four experimental groups (n = 20), based on the final rinse: no activation; EA; PUI; ED, using 2.5% sodium hypochlorite, with an EDTA intermediate rinse. A control group (n = 3) was irrigated with distilled water without activation. The solutions were delivered using a syringe and needle 2 mm from working length. Total irrigation time was 150 s, including 60 s of activation in the specific groups. The study was carried out at 36 ± 2 °C. The porcine palatal mucosa samples were weighed after completion of the assays. Student paired t-test and anova were used to assess the intra- and intergroup weight changes. The multiple comparisons were evaluated using Bonferroni correction (α = 0.05). Results: Weight loss occurred in all experimental groups. Irrigant activation resulted in greater weight loss when compared to the nonactivated group [vs. EA (P = 0.001); vs. PUI (P < 0.001); vs. ED (P < 0.001)]. No significant differences were found amongst the different activation systems. Conclusions: Activation increased the tissue-dissolving activity of irrigants from artificial grooves in root canals of maxillary central incisors. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Self-assembled silk fibroin (SF)-polyethylenimine (PEI) multilayered films were fabricated on ethanol treated electrospun SF nanofibrous substrates via the electrostatic layer-by-layer (LBL) adsorption. The film coated membranes were characterized using scanning electron microscopy (SEM), transmission electron microscope (TEM) and X-ray photoelectron spectrophotometer (XPS). The SEM images showed that the multilayers of SF-PEI were formed on the surface of the ethanol treated SF nanofibres. The characteristics such as the fiber shape and porous structure were well maintained as the number of the coated SF-PEI bilayers was less than five. However, obvious adhesive substances and blocked pores were observed on the surface of the fibers as the number of bilayers of SF-PEI increased to six. Furthermore, the obvious core-shell structures were observed by TEM. The thickness of five SF-PEI bilayers was approximately 80nm. Additionally, the XPS results also revealed that the SF-PEI multilayer composite membranes formed. The adsorption mainly depended on a simple electrostatic interaction between the layers of SF and PEI. These SF-PEI multilayer assembled nanofibrous membranes could be a promising material for use as a sensor, gene delivery agent and scaffolds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poly(aryl-ether-ether-ketone) (PEEK) is a semi crystalline polymer which exhibits properties that make it an attractive choice for use as an implant material. It displays natural radiolucency, and MRI compatibility, as well as good chemical and sterilization resistance, both of which make it of particular interest in orthopaedic implants. However, PEEK has demonstrated poor cellular adhesion both in vitro and in vivo. This is problematic as implant surfaces that do not develop a layer of adhesive cells are at risk of undergoing fibrous encapsulation, which in turn leads to lack of a strong interface between the implant device and the patient tissue, which can in turn lead to failure of the implant and revision surgery . As incorporating nanotopography into a polymer surface has been demonstrated to be able to direct the differentiation behaviour of stem cells, a possible solution to PEEKs underlying issues with poor cellular response would be to incorporate specific nanoscale topography into the material surface through injection moulding, and then analysing if this is a viable method for addressing PEEKs issues with cellular response. In addition to nanoscale topography, the experimental PEEK surfaces were treated with oxygen plasma to address the underlying cytophobicity of the material. As this type of treatment has been documented to be capable of etching the PEEK surface, experiments were carried out to quantify the effect of this treatment, both on the ability of cells to adhere to the PEEK surface, as well as the effect it has upon the nanotopography present at the PEEK surface. The results demonstrated that there were a range of plasma treatments which would significantly improve the ability of cells to adhere to the PEEK surface without causing unacceptable damage to the nanotopography. Three different types of cells with osteogenic capacity were tested with the PEEK surfaces to gauge the ability of the topography to alter their behaviour: SAOS-2, osteoprogenitors and 271+ MSCs. Due to PEEKs material properties (it is non transparent, exhibits birefringence and is strongly autofluorescent) a number of histological techniques were used to investigate a number of different stages that take place in osteogenesis. The different cell types did display slightly different responses to the topographies. The SAOS-2 cells cultured on surfaces that had been plasma treated for 2 minutes at 200W had statistically significantly higher levels of von Kossa staining on the NSQ surface compared to the planar surface, and the same experiment employing alizarin red staining, showed a statistically significantly lower level of staining on the SQ surface compared to the planar surface. Using primary osteoprogenitor cells designed to look into if whether or not the presence of nanotopography effected the osteogenic response of these cells, we saw a lack of statistically significant difference produced by the surfaces investigated. By utilising HRP based immunostaining, we were able to investigate, in a quantitative fashion, the production of the two osteogenic markers osteopontin and osteocalcin by cells. When stained for osteocalcin, the SQ nanotopography had total percentage of the surface with stained material, average area and average perimeter all statistically significantly lower than the planar surface. For the cells that were stained for osteopontin, the SQ nanotopgraphy had a total percentage of the surface with stained material, average area and average perimeter all highly statistically significantly lower than those of the planar surface. Additionally, for this marker the NSQ nanotopography had average areas and average perimeters that were highly significantly higher than those of the planar surface. There were no significant differences for any of the values investigated for the 271+ MSC’s When plasma treatment was varied, the SAOS-2 cells demonstrated an overall trend i.e. increasing the energy of plasma treatment in turn leads to an increase in the overall percentage of staining. A similar experiment employing stem cells isolated from human bone marrow instead of SAOS-2 cells showed that for polycarbonate surfaces , used as a control, mineralization is statistically significantly higher on the NSQ nanopattern compared to the planar surface, whereas on the PEEK surfaces we observe the opposite trend i.e. the NSQ nanotopography having a statistically significantly lower amount of mineralization compared to the planar surface at the 200W 2min and 30W 1min plasma treatments. The standout trend from the PEEK results in this experiment was that the statistically significant differences on the PEEK substrates were clustered around the lower energy plasma treatments, which could suggest that the plasma treatment disrupted a function of the nanotopograhy which is why, as the energy increases, there are less statistically significant differences between the NSQ nanotopography and the Planar surface This thesis documents the response of a number of different types of cells to specific nanoscale topographies incorporated into the PEEK surface which had been treated with oxygen plasma. It outlines the development of a number of histological methods which measure different aspects of osteogenesis, and were selected to both work with PEEK, and produce quantitative results through the use of Cell Profiler. The methods that have been employed in this body of work would be of interest to other researchers working with this material, as well as those working with similarly autofluorescent materials.