962 resultados para electrospray ionization mass spectrometry (ESI-MS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stir bar sorptive extraction and liquid desorption followed by large volume injection coupled to gas chromatography–quadrupole mass spectrometry (SBSE–LD/LVI-GC–qMS) had been applied for the determination of volatiles in wines. The methodology was optimised in terms of extraction time and influence of ethanol in the matrix; LD conditions, and instrumental settings. The optimisation was carried out by using 10 standards representative of the main chemical families of wine, i.e. guaiazulene, E,E-farnesol, β-ionone, geranylacetone, ethyl decanoate, β-citronellol, 2-phenylethanol, linalool, hexyl acetate and hexanol. The methodology shows good linearity over the concentration range tested, with correlation coefficients higher than 0.9821, a good reproducibility was attained (8.9–17.8%), and low detection limits were achieved for nine volatile compounds (0.05–9.09 μg L−1), with the exception of 2-phenylethanol due to low recovery by SBSE. The analytical ability of the SBSE–LD/LVI-GC–qMS methodology was tested in real matrices, such as sparkling and table wines using analytical curves prepared by using the 10 standards where each one was applied to quantify the structurally related compounds. This methodology allowed, in a single run, the quantification of 67 wine volatiles at levels lower than their respective olfactory thresholds. The proposed methodology demonstrated to be easy to work-up, reliable, sensitive and with low sample requirement to monitor the volatile fraction of wine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The establishment of potential age markers of Madeira wine is of paramount significance as it may contribute to detect frauds and to ensure the authenticity of wine. Considering the chemical groups of furans, lactones, volatile phenols, and acetals, 103 volatile compounds were tentatively identified; among these, 71 have been reported for the first time in Madeira wines. The chemical groups that could be used as potential age markers were predominantly acetals, namely, diethoxymethane, 1,1-diethoxyethane, 1,1-diethoxy-2-methyl-propane, 1-(1-ethoxyethoxy)-pentane, trans-dioxane and 2-propyl-1,3-dioxolane, and from the other chemical groups, 5-methylfurfural and cis-oak-lactone, independently of the variety and the type of wine. GC × GC-ToFMS system offers a more useful approach to identify these compounds compared to previous studies using GC−qMS, due to the orthogonal systems, that reduce coelution, increase peak capacity and mass selectivity, contributing to the establishment of new potential Madeira wine age markers. Remarkable results were also obtained in terms of compound identification based on the organized structure of the peaks of structurally related compounds in the GC × GC peak apex plots. This information represents a valuable approach for future studies, as the ordered-structure principle can considerably help the establishment of the composition of samples. This new approach provides data that can be extended to determine age markers of other types of wines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical procedure using supercritical fluid extraction (SFE) and capillary gas chromatography with electron-capture detection was developed to determine simultaneously residues of different pesticides (organochlorine, organophosphorus, organonitrogen and pyrethroid) in honey samples. Fortification experiments were conducted to test conventional extraction (liquid-liquid) and optimize the extraction procedure in SFE by varying the CO2-modifier, temperature, extraction time and pressure. Best efficiency was achieved at 400 bar using acetonitrile as modifier at 90 degreesC. For the clean-up step, Florisil cartridges were used for both methods LLE and SFE. Recoveries for majority of pesticides from fortified samples of honey at fortification level of 0.01-0.10 mg/kg ranged 75-94% from both methods. Limits of detection found were less than 0.01 mg/kg for ECD and confirmation of pesticide identity was performed by gas chromatography-mass spectrometry in selected-ion monitoring mode. The multiresidue methods in real honey samples were applied and the results of developed methods were compared. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The applicability of supercritical fluid extraction (SFE) in pesticide multiresidue analysis (organohalogen, organonitrogen, organophosphorus, and pyrethroid) in soil samples was investigated. Fortification experiments were conducted to test the conventional extraction (solid-liquid) and to optimize the extraction procedure in SFE by varying the CO2 Modifier, temperature, extraction time, and pressure. The best efficiency was achieved at 400 bar using methanol as modifier at 60 degreesC. For the SFE method, C-18 cartridges were used for the cleanup. The analytical screening was performed by gas chromatography equipped with electron-capture detection (ECD). Recoveries for the majority of pesticides from spiked samples of soil at different residence times were 1, 20, and 40 days at the fortification level of 0.04-0.10 mg/kg ranging from 70 to 97% for both methods. The detection limits found were <0.01 mg/kg for ECD, and the confirmation of pesticide identity was performed by gas chromatography-mass spectrometry in a selected-ion monitoring mode. Multiresidue methods were applied in real soil samples, and the results of the methods developed were compared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the study of the fragmentation process of diethylene glycol dimethyl ether (CH3O(CH2CH2O)(2)CH3) (diglyme here in) molecule in low pressure RF excited plasma discharges. The study was carried out using mass spectrometry. The results showed that for a fixed pressure, the increase of the RF power coupled to the plasma chamber from 1 to 35 W produced a plasma environment much more reactive which increases the population of the ionized species like CH3+ (15 amu), C2H4+ (28 amu), CH3O+ (31 amu), C2H4O+ (44 amu), CH3OCH2CH2+ (59 amu) and CH3OCH2CH2O+ (75 amu). This fact may be attributed to the increase of the electronic temperature that makes predominant the occurrence of inelastic processes that promotes molecular fragmentation. For a fixed value of RF power the increase of pressure from 50 mTorr to 100 mTorr produces the decreasing of the above mentioned chemical species due the lower electronic mean free path. These results suggest that if one wants to keep the monomer's functionality within the plasma deposited films resulting from such kind of discharges one must operate in low power conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the separation and identification of indole alkaloids, steroids and triterpenoids from the ethanolic extracts of Tabernaemontana hilariana (Apocynaceae). The alkaloidal fractions from the ethanolic extracts obtained (root barks, green fruits, ripe fruits and seeds) were fractionated and analysed by thin-layer chromatography, capillary gas chromatography-flame ionization detection (cGC-FID) as well as by high-resolution gas chromatography-mass spectrometry (HRGC-MS). 3-Hydroxycoronaridine, ibogamine, coronaridine pseudoindoxyl, coronaridine, catharanthine, voacangine hydroxyindolenine, voacangine pseudoindoxyl, tabernanthine, tetraphyllicine, 3-hydroxyvoacangine, voacangine, isovoacangine and 3-oxocoronaridine were identified. The insoluble fraction of ethanolic extracts obtained from the root barks and green fruits were analysed and ten aliphatic constituents were also identified by cGC-FID and HRGC-MS. (C) 1998 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Propanil and its major degradation product, 3,4-dichloroaniline (DCA), were monitored in surface water and soil samples from two rice fields of the Ebre Delta area (Tarragona, Spain) following agricultural application. On-line solid-phase extraction (SPE) (water) and Soxhlet extraction (soil) followed by liquid chromatography/diode array detection (LC/DAD) were used for the trace determination of both compounds. Unequivocal confirmation/identification was conducted by using liquid chromatography/atmospheric pressure chemical ionization-mass spectrometry, LC/APCI/MS (using negative and positive ionization modes). Concentrations of the herbicide propanil in water samples varied from 1.9 to 55.9 mu g/L. Propanil degraded very rapidly to DCA, and high concentrations of this product were found, varying from 16.5 to 470 mu g/L in water and 119 +/- 22 mu g/kg in soil samples. No detectable DCA (<0.001%) was found in the applied pesticide formulation, indicating that DCA formation took place after propanil application. These field results compared favorably with laboratory experiments showing that humic interactions had a strong influence on the pesticide degradation. The half-lifes under real conditions for propanil and DCA, calculated using a first-order decay, were 1.2 and 1.6 days, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method is described for the rapid, sensitive, virtually interference-free, and selective quantitation of cyanogenic glycosides in aqueous extracts using membrane introduction mass spectrometry (MIMS). Selective monitoring, by either conventional MIMS or cryotrap-MIMS, not of HCN but of the co-released ketones (acetone and butan-2-one), when performed for both the crude cassava extracts and the linamarase-NaOH-hydrolyzed extracts, is found to offer an advantageous alternative to classic spectrophotometric methods based on HCN analysis for the selective quantitation of the two cyanogenic glycosides linamarin and lotaustralin expressed as both the free HCN content and the total cyanogenic potential (total HCN).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current knowledge of the bioavailability of lycopene in humans is limited due to the inability to distinguish newly administered lycopene from the body reserves of lycopene. A quantitative method to assess the absorption and relative bioavailability of newly absorbed synthetic or natural lycopene was developed using two deuterated lycopene sources, in conjunction with an advanced LC/APCI-MS (liquid chromatography/atmospheric pressure chemical ionization-mass spectrometry) to analyze newly absorbed lycopene in blood samples of study subjects. Two subjects (1 male and 1 female) consumed hydroponically grown tomatoes containing deuterium-enriched lycopene (8084 g wet weight tomato containing 16.3 and 17.4 mu mol lycopene, respectively) and two subjects (1 male, and 1 female) consumed 11 mu mol synthetic H-2(10) lycopene in 6 g of corn oil. Tomatoes were steamed and pureed. The doses were given together with a liquid formulated drink with 25% energy from fat. Our results showed that up to 34 days after taking an oral 2 1110 lycopene dose (synthetic or from tomato) with a liquid formula drink, the area under the curve of the average serum percent enrichment response of synthetic lycopene reached 33.9 (+/- 1.7) nmol-day/mu mol lycopene in the dose, whereas that of lycopene from the tomato dose was 11.8 (+/- 0.3) nmol-day/mu mol lycopene in the dose. Our study provides evidence that the absorption of physiological levels of lycopene in intrinsically labeled tomatoes can be studied in humans. From these preliminary investigations, we find that the bioavailability of synthetic lycopene in oil appears to be about three times higher than that of lycopene from steamed and pureed tomatoes. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow-injection (FI) system to match concentrations was used as an auto-diluter in multielement determination by inductively coupled plasma-mass spectrometry (ICP-MS). The flow system comprised loop-based injection or a timed valve that introduced a variable sample volume info a spray chamber through a standard Meinhard nebulizer of an ICP-MS. Routinely analyzed samples such as water, plant, and steel were selected. The accuracy of multielement determination was checked against water standard reference material from the National Institute of Standards and Technology (1643d), plant standard reference material from the National Bureau of Standards (1572 citrus leaves), and steel standard reference material from the National Bureau of Standards (AISI 4340). The measuring system was calibrated with a multielement solution, yielding a linear plot with good precision [relative standard deviation (RSD) < 3%, n = 12]. The results were in agreement at a 95% confidence level with the certified values for the reference materials and also with those obtained by continuous aspiration and by (FI) with a discrete volume. (C) 1999 John Wiley & Sons, Inc.