988 resultados para diagnostic imaging
Resumo:
The determination of characteristic cardiac parameters, such as displacement, stress and strain distribution are essential for an understanding of the mechanics of the heart. The calculation of these parameters has been limited until recently by the use of idealised mathematical representations of biventricular geometries and by applying simple material laws. On the basis of 20 short axis heart slices and in consideration of linear and nonlinear material behaviour we have developed a FE model with about 100,000 degrees of freedom. Marching Cubes and Phong's incremental shading technique were used to visualise the three dimensional geometry. In a quasistatic FE analysis continuous distribution of regional stress and strain corresponding to the endsystolic state were calculated. Substantial regional variation of the Von Mises stress and the total strain energy were observed at all levels of the heart model. The results of both the linear elastic model and the model with a nonlinear material description (Mooney-Rivlin) were compared. While the stress distribution and peak stress values were found to be comparable, the displacement vectors obtained with the nonlinear model were generally higher in comparison with the linear elastic case indicating the need to include nonlinear effects.
Resumo:
INTRODUCTION: Although long-term video-EEG monitoring (LVEM) is routinely used to investigate paroxysmal events, short-term video-EEG monitoring (SVEM) lasting <24 h is increasingly recognized as a cost-effective tool. Since, however, relatively few studies addressed the yield of SVEM among different diagnostic groups, we undertook the present study to investigate this aspect. METHODS: We retrospectively analyzed 226 consecutive SVEM recordings over 6 years. All patients were referred because routine EEGs were inconclusive. Patients were classified into 3 suspected diagnostic groups: (1) group with epileptic seizures, (2) group with psychogenic nonepileptic seizures (PNESs), and (3) group with other or undetermined diagnoses. We assessed recording lengths, interictal epileptiform discharges, epileptic seizures, PNESs, and the definitive diagnoses obtained after SVEM. RESULTS: The mean age was 34 (±18.7) years, and the median recording length was 18.6 h. Among the 226 patients, 127 referred for suspected epilepsy - 73 had a diagnosis of epilepsy, none had a diagnosis of PNESs, and 54 had other or undetermined diagnoses post-SVEM. Of the 24 patients with pre-SVEM suspected PNESs, 1 had epilepsy, 12 had PNESs, and 11 had other or undetermined diagnoses. Of the 75 patients with other diagnoses pre-SVEM, 17 had epilepsy, 11 had PNESs, and 47 had other or undetermined diagnoses. After SVEM, 15 patients had definite diagnoses other than epilepsy or PNESs, while in 96 patients, diagnosis remained unclear. Overall, a definitive diagnosis could be reached in 129/226 (57%) patients. CONCLUSIONS: This study demonstrates that in nearly 3/5 patients without a definitive diagnosis after routine EEG, SVEM allowed us to reach a diagnosis. This procedure should be encouraged in this setting, given its time-effectiveness compared with LVEM.
Resumo:
Neural stem cells have been proposed as a new and promising treatment modality in various pathologies of the central nervous system, including malignant brain tumors. However, the underlying mechanism by which neural stem cells target tumor areas remains elusive. Monitoring of these cells is currently done by use of various modes of molecular imaging, such as optical imaging, magnetic resonance imaging and positron emission tomography, which is a novel technology for visualizing metabolism and signal transduction to gene expression. In this new context, the microenvironment of (malignant) brain tumors and the blood-brain barrier gains increased interest. The authors of this review give a unique overview of the current molecular-imaging techniques used in different therapeutic experimental brain tumor models in relation to neural stem cells. Such methods for molecular imaging of gene-engineered neural stem/progenitor cells are currently used to trace the location and temporal level of expression of therapeutic and endogenous genes in malignant brain tumors, closing the gap between in vitro and in vivo integrative biology of disease in neural stem cell transplantation.
Resumo:
Although not specific, an increased in peripheral blood eosinophils may contribute substantially to the diagnosis of numerous infectious, allergic and inflammatory diseases. The scope of this article is to detail pathologies associated with peripheral eosinophilia by order of frequency and to guide further investigations.
Resumo:
BACKGROUND AND PURPOSE: Neuromyelitis optica (NMO) or Devic's disease is a rare inflammatory and demyelinating autoimmune disorder of the central nervous system (CNS) characterized by recurrent attacks of optic neuritis (ON) and longitudinally extensive transverse myelitis (LETM), which is distinct from multiple sclerosis (MS). The guidelines are designed to provide guidance for best clinical practice based on the current state of clinical and scientific knowledge. SEARCH STRATEGY: Evidence for this guideline was collected by searches for original articles, case reports and meta-analyses in the MEDLINE and Cochrane databases. In addition, clinical practice guidelines of professional neurological and rheumatological organizations were studied. RESULTS: Different diagnostic criteria for NMO diagnosis [Wingerchuk et al. Revised NMO criteria, 2006 and Miller et al. National Multiple Sclerosis Society (NMSS) task force criteria, 2008] and features potentially indicative of NMO facilitate the diagnosis. In addition, guidance for the work-up and diagnosis of spatially limited NMO spectrum disorders is provided by the task force. Due to lack of studies fulfilling requirement for the highest levels of evidence, the task force suggests concepts for treatment of acute exacerbations and attack prevention based on expert opinion. CONCLUSIONS: Studies on diagnosis and management of NMO fulfilling requirements for the highest levels of evidence (class I-III rating) are limited, and diagnostic and therapeutic concepts based on expert opinion and consensus of the task force members were assembled for this guideline.
Resumo:
The 1st chapter of this work presents the different experiments and collaborations in which I am involved during my PhD studies of Physics. Following those descriptions, the 2nd chapter is dedicated to how the radiation affects the silicon sensors, as well as some experimental measurements carried out at CERN (Geneve, Schwitzerland) and IFIC (Valencia, Spain) laboratories. Besides the previous investigation results, this chapter includes the most recent scientific papers appeared in the latest RD50 (Research & Development #50) Status Report, published in January 2007, as well as some others published this year. The 3rd and 4th are dedicated to the simulation of the electrical behavior of solid state detectors. In chapter 3 are reported the results obtained for the illumination of edgeless detectors irradiated at different fluences, in the framework of the TOSTER Collaboration. The 4th chapter reports about simulation design, simulation and fabrication of a novel 3D detector developed at CNM for ions detection in the future ITER fusion reactor. This chapter will be extended with irradiation simulations and experimental measurements in my PhD Thesis.
Resumo:
Workers performing preparation and administration of radiopharmaceuticals in NM departments are likely to receive high local skin doses to the hands which may even surpass the dose limit of 500 mSv whenever radiation protection standards are insufficient. A large measurement campaign was organised within the framework of the ORAMED project to determine the dose distribution across the hands received during preparation and administration of 18F- and 99mTc-labelled radiopharmaceuticals. The final data, collected over almost 3 years, include 641 measurements from 96 workers in 30 NM departments from 6 European countries. Results have provided levels of reference doses for the considered standard NM diagnostic procedures (mean maximum normalised skin dose of 230 μSv/GBq, 430 μSv/GBq, 930 μSv/GBq and 1200 μSv/GBq for the administration of 99mTc, preparation of 99mTc, administration of 18F and preparation of 18F, respectively). Finger dose was analysed as a function of the potential parameters of influence showing that shielding is the most efficient means of radiation protection to reduce skin dose. An appropriate method for routine monitoring of the extremities is also proposed: the base of the index finger of the non-dominant hand is a suitable position to place the ring dosemeter, with its sensitive part oriented towards the palm side; its reading may be multiplied by a factor of 6 to estimate the maximum local skin dose. Finally, results were compared to earlier published data, which correspond mostly to individual works with a reduced number of workers and measurements.
Resumo:
PURPOSE: To introduce a new k-space traversal strategy for segmented three-dimensional echo planar imaging (3D EPI) that encodes two partitions per radiofrequency excitation, effectively reducing the number excitations used to acquire a 3D EPI dataset by half. METHODS: The strategy was evaluated in the context of functional MRI applications for: image quality compared with segmented 3D EPI, temporal signal-to-noise ratio (tSNR) (the ability to detect resting state networks compared with multislice two-dimensional (2D) EPI and segmented 3D EPI, and temporal resolution (the ability to separate cardiac- and respiration-related fluctuations from the desired blood oxygen level-dependent signal of interest). RESULTS: Whole brain images with a nominal voxel size of 2 mm isotropic could be acquired with a temporal resolution under half a second using traditional parallel imaging acceleration up to 4× in the partition-encode direction and using novel data acquisition speed-up of 2× with a 32-channel coil. With 8× data acquisition speed-up in the partition-encode direction, 3D reduced excitations (RE)-EPI produced acceptable image quality without introduction of noticeable additional artifacts. Due to increased tSNR and better characterization of physiological fluctuations, the new strategy allowed detection of more resting state networks compared with multislice 2D-EPI and segmented 3D EPI. CONCLUSION: 3D RE-EPI resulted in significant increases in temporal resolution for whole brain acquisitions and in improved physiological noise characterization compared with 2D-EPI and segmented 3D EPI. Magn Reson Med 72:786-792, 2014. © 2013 Wiley Periodicals, Inc.
Resumo:
Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat limited due to fluorescence false-positive sites. Consequently, magnification cystoscopy has been investigated in order to discriminate false from true fluorescence positive findings. Both white-light and fluorescence modes are possible with the magnification cystoscope, allowing observation of the bladder wall with magnification ranging between 30× for standard observation and 650×. The optical zooming setup allows adjusting the magnification continuously in situ. In the high-magnification (HM) regime, the smallest diameter of the field of view is 600 microns and the resolution is 2.5 microns when in contact with the bladder wall. With this cystoscope, we characterized the superficial vascularization of the fluorescing sites in order to discriminate cancerous from noncancerous tissues. This procedure allowed us to establish a classification based on observed vascular patterns. Seventy-two patients subject to Hexvix® fluorescence cystoscopy were included in the study. Comparison of HM cystoscopy classification with histopathology results confirmed 32?33 (97%) cancerous biopsies and rejected 17?20 (85%) noncancerous lesions.
Resumo:
AIM: The first pathogenetic step in multiple myeloma is the emergence of a limited number of clonal plasma cells, clinically known as monoclonal gammopathy of undetermined significance (MGUS). Patients with MGUS do not have symptoms or end-organ damage but they do have a 1% annual risk of progression to multiple myeloma or related malignant disorders. With progression of MGUS to multiple myeloma, complex genetic events occur in the neoplastic plasma cell. Karyotyping and fluorescence in-situ hybridization (FISH) were shown to be of prognostic value in patients with multiple myeloma. Tc-sestamibi imaging reflects myeloma disease activity in bone marrow with very high sensitivity and specificity predicting disease evolution. This study was undertaken to evaluate the role of Tc-sestamibi imaging and cytogenetic analysis in prognosis prediction of MGUS and multiple myeloma. METHODS: We enrolled 30 consecutive patients with a confirmed diagnosis of multiple myeloma or MGUS. Bone marrow biopsy and biochemical staging according to the International Staging System (ISS) were performed in all cases. Karyotype analysis and FISH were performed in 11 of 12 patients with MGUS and in 17 of 18 patients with multiple myeloma having adequate metaphases. RESULTS: The karyotype was abnormal in four of 11 MGUS and in six of 17 multiple myeloma. Abnormalities of chromosome 13 were present in one case of MGUS and in six cases of multiple myeloma whereas the involvement of immunoglobulin was observed in one case of multiple myeloma. An abnormal FISH panel was found in four MGUS and nine multiple myeloma patients. All patients with MGUS showed a normal MIBI scan (score 0). Among patients with multiple myeloma only three, all with ISS stage I, showed a normal scan while a positive scan was obtained in others (score range, 1-7). The MIBI uptake was strongly related to the bone marrow plasma cell infiltration and to cytogenetic abnormalities. Particularly, a MIBI uptake score above 5 identified patients with poor prognosis encompassing all stage III multiple myeloma and three of seven stage II multiple myeloma. On the other hand all stage I and II patients having a MIBI score less than 5 showed a good prognosis. CONCLUSION: Both cytogenetic analysis and a MIBI scan add no relevant prognostic information to the ISS in patients with stage I and III multiple myeloma. The MIBI scan was of prognostic value in stage II multiple myeloma patients. Additionally, MIBI imaging may be useful to guide bone marrow biopsy in order to obtain adequate samples for cytogenetic analysis.
Resumo:
Electroencephalography is mandatory to determine the epilepsy syndrome. However, for the precise localization of the irritative zone in patients with focal epilepsy, costly and sometimes cumbersome imaging techniques are used. Recent small studies using electric source imaging suggest that electroencephalography itself could be used to localize the focus. However, a large prospective validation study is missing. This study presents a cohort of 152 operated patients where electric source imaging was applied as part of the pre-surgical work-up allowing a comparison with the results from other methods. Patients (n = 152) with >1 year postoperative follow-up were studied prospectively. The sensitivity and specificity of each imaging method was defined by comparing the localization of the source maximum with the resected zone and surgical outcome. Electric source imaging had a sensitivity of 84% and a specificity of 88% if the electroencephalogram was recorded with a large number of electrodes (128-256 channels) and the individual magnetic resonance image was used as head model. These values compared favourably with those of structural magnetic resonance imaging (76% sensitivity, 53% specificity), positron emission tomography (69% sensitivity, 44% specificity) and ictal/interictal single-photon emission-computed tomography (58% sensitivity, 47% specificity). The sensitivity and specificity of electric source imaging decreased to 57% and 59%, respectively, with low number of electrodes (<32 channels) and a template head model. This study demonstrated the validity and clinical utility of electric source imaging in a large prospective study. Given the low cost and high flexibility of electroencephalographic systems even with high channel counts, we conclude that electric source imaging is a highly valuable tool in pre-surgical epilepsy evaluation.