940 resultados para correlation coefficient analysis
Resumo:
A simple and reproducible method was developed for the assay of lomefloxacin in tablets. The excipients in the commercial tablet preparation did not interfere with the assay. Beer's law is obeyed in the range 2.0-9.0 μg.mL-1 at λmax 280 nm. The molar absorptivity was calculated. Six triplicate analyses of solutions containing six different concentrations of the examined drug were carried out and gave a mean correlation coefficient 0.9997. The proposed method was applied to the determination of the examined drug in coated tablet and the results demonstrated that the method is equally accurate, precise and reproducible as the official methods.
Resumo:
This paper describes a very simple and rapid quantitative reflectance spot test procedure for the determination of methyldopa in pharmaceutical formulations. This method is based on the complexation reaction of methyldopa with molybdate ions yielding a yellow stable complex on filter paper. Reflectance measurements were carried out at 410 nm. Under optimal conditions, the calibration graphs obtained for methyldopa by plotting the optical density of the reflectance signal (A R) vs. the log of the concentration were linear from 6.30 × 10 -3 to 1.89 × 10 -2 mol L -1, with a correlation coefficient of 0.998. The detection limit was 2.74 × 10 -3 mol L -1 (R.S.D. = 1.02%) for methyldopa. The common excipients used as additives in pharmaceuticals do not interfere in the proposed method. The method was applied to determine metyldopa in commercial pharmaceutical formulations. The results obtained by the proposed method compare favorably with those obtained by an official procedure at 95% confidence level. ©2006 Sociedade Brasileira de Química.
Resumo:
Purpose: Selecting artificial teeth for edentulous patients is difficult when pre-extraction records are not available. Various guidelines have been suggested for determining the width of the maxillary anterior denture teeth. This study was undertaken to evaluate the use of the nasal width as a guide for the selection of proper width maxillary anterior denture teeth in four racial groups of the Brazilian population. Materials and Methods: One hundred and sixty subjects (40 Whites, 40 Mulattos, 40 Blacks, and 40 Asians) were selected. Using a sliding caliper, the nasal width and the intercanine distance were measured. The Pearson product-moment correlation coefficient was used to determine the relationship between the above measurements. A prediction was made of the percentage of subjects of the White, Mulatto, Black, and Asian populations in which the selection error due to the clinical application of the method of the nasal width would be within 0 to 2 mm, within 2 to 4 mm, and greater than 4 mm. Results: The four racial groups showed a weak correlation between the intercanine distance and the nasal width. In 39.7% of the White, 55.7% of the Mulatto, 81.9% of the Black, and 48.2% of the Asian populations, errors greater than 4 mm would be present with the use of the nasal width. Conclusions: The correlation found between the intercanine distance and the nasal width was not high enough to be used as a predictive factor. The relationship between natural tooth width and artificial tooth width as predicted by the nasal width showed that the nasal width method is not accurate for all the studied groups. Copyright © 2006 by The American College of Prosthodontists.
Resumo:
As arterial hypertension can be diagnosed by different methods, among which are the traditional auscultatory instrument and the automated oscillometric monitor, the aim of this study was to compare the performance of these instruments, to evaluate the reliability of the digital oscillometer. The sample consisted of 40 patients under dental treatment, whose blood pressure measurements were recorded. The measurements of systolic and diastolic blood pressures were evaluated in terms of their intraclass correlation coefficients (r). For systolic blood pressure, an excellent level of agreement was found between the instruments, with r=0.93, and for diastolic blood pressure, there was a good level of agreement (r=0.75). It was concluded, from the excellent agreement for systolic blood pressure, that the oscillometric monitor can be recommended for the monitoring of the variations of that pressure in the same individual, while the good agreement obtained in the determination of the diastolic blood pressure indicates that the oscillometric method is reliable. However, new studies need to be carried out for a better understanding of the disagreements that can occur in the diastolic pressure results.
Resumo:
PURPOSE: to evaluate the loco-regional response to primary chemotherapy in patients with breast cancer at stages II and III. METHODS: a retrospective and analytical clinical study carried out in 97 patients with an average age of 52.2 years old, with breast cancer at stages II and III, attended from January 1993 to December 2004, and submitted to 3 to 4 cycles of primary chemotherapy with 5-fl uorouracil - 500 mg/m2, epirubicin - 50 mg/m2 and cyclophosphamide - 500 mg/m2 or doxorubicin - 50 mg/m2 e cyclophosphamide - 500 mg/m2, and then to loco-regional surgical conservative or radical surgical treatment. Chi-square and Fisher's exact tests were used to study the association among the variables (age, menopausal state, pre-chemotherapy tumoral volume, axillary condition, stage, therapeutic scheme and number of cycles), while Pearson's correlation coefficient was used for the quantitative variables (tumoral volume according to the anatomo-pathological study and the post-chemotherapy clinical tumoral volume. The significance level was 5%. RESULTS: there were 56.8% of cases at stage II and 43.2% at stage III. Approximately 50% of the patients received FEC50 and 50% AC. Objective clinical response with primary chemotherapy was obtained in 64.9% of the cases. Full clinical response occurred in 12.3% of patients, while full pathological response occurred in 10.3% of the cases. CONCLUSIONS: there was a statistically significant correlation between the number of cycles and the response to primary chemotherapy. Patients who received 4 cycles had better response than those who received 3 cycles. There was also a statistically significant concordance between the evaluation through clinical examination of the response to primary chemotherapy and the pathological findings. No statistically significant correlation was observed concerning age, menopausal status, tumoral volume, and pretreatment of axillary damage.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Puberty is the fundamental period for bone mass (BM) acquisition. In this period mineralization is found to increase with levels of high bone formation. The critical years of intense bone anabolism deserve special attention, as adequate gain could minimize fracture risk in later years. The objective of this work was to study bone mineral content (BMC) and bone mineral density (BMD) in male adolescents with age bracket and maturation level. Sixty-one healthy male 10 to 19 year-olds were evaluated for calcium intake, weight, stature, BMI, puberty stage and BMC and BMD in the lumbar spine and femur. BM was measured by bone densitometry (DXA). Calcium intake was calculated by recording 3 days diet. Puberty stage was defined as per Tanner. Descriptive statistics was used with means and standard deviations, linear correlation, and analysis of variance for comparison between age groups, and the Tukey test (p<0.05). Linear correlation was positive and indicated body weight as the main correlation variable with BMD in both studied locations (p<0.01). BMC and BMD increased with age, differences were significant from 14 to 15 years, and when adolescents reached Tanner stage G4. These results showed a pronounced increase in bone mineralization, with the years after 14 to 15 being critical for BM acquisition in Brazilian adolescents.
Resumo:
This paper describes a simple, portable and environmentally friendly method for the rapid determination of dipyrone in pharmaceuticals by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound produced from the spot test reaction between dipyrone and p-dimethylaminocinnamaldehyde (p-DAC), in acid medium, using a filter paper as solid support. Experimental design methodologies were used to optimize the measurement conditions. All reflectance measurements were carried out at 510 nm and the linear range was from 1.42 × 10-4-2.85 × 10-3 mol L-1, with a correlation coefficient of 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 1.20 × 10-5 mol L-1 and 4.00 × 10-5 mol L-1, respectively. The intraday precision and interday precision were studied for 10 replicate analyses of 7.90 × 10-4 mol L-1 dipyrone solution. The coefficients of variation were 1.1 and 0.9%, respectively. The proposed method was applied successfully to the determination of dipyrone in commercial brands of pharmaceuticals. No interferences were observed from the common excipients in formulations. The results obtained by the proposed method were favorably compared with those given by the Brazilian Pharmacopoeia procedure at 95% confidence level. ©2007 Sociedade Brasileira de Química.
Resumo:
The advances in digital imaging technology in dentistry have provided an alternative to film-based radiography and have given new options to detect periodontal bone loss. The purpose of this study was to compare inverted and unprocessed digitized radiographic imaging in periodontal bone loss measurements. Thirty-five film-based periapical radiographs of patients suffering from moderate to advanced untreated periodontal bone loss associated to lower premolar and molars was selected from the department files, with 40 bone loss areas. The film-based radiographs were digitized with a flatbed scanner with a transparency and radiograph adapter used for transilluminating the radiograph imaging. Digitization was performed at 600 dpi and in gray scale. The images were digitized using Image Tool software by applying image inversion, that is, transformation of radiopaque structures into radiolucent structures and vice-versa. The digital data were saved as JPEG files. The images were displayed on a 15-inch and 24-bit video monitor under reduced room lighting. One calibrated examiner performed all radiographic measurements, three times, from the cementoenamel junction to the most apical extension of the bone loss, in both types of image (inverted and unprocessed). Brightness and contrast were adjusted according to the examiner's individual demand. Intraclass correlation coefficient was used to compare the measurements from both types of images. The means of radiographic measurements, in mm, for inverted and unprocessed digitized imaging were 6.4485 and 6.3790, respectively. The intraclass correlation coefficient was significant (0.99) The inverted and unprocessed digitized radiographic images were reliable and there was no difference in the diagnostic accuracy between these images regarding periodontal bone loss measurements.
Resumo:
The study evaluated the efficiency of diagnostic laboratory methods to detect anti-Toxoplasma gondii antibodies in paired serum and aqueous humour samples from experimentally infected pigs. 18-mixed breed pigs were used during the experiment; these were divided into two groups, G1 (infected group, n = 10) and G2 (uninfected group, n = 8). Infection was performed with 4 × 10 4 VEG strain oocysts at day 0 by the oral route in G1 animals. All pigs were euthanized at day 60, when retina, aqueous humour, and blood samples were collected. Anti-T. gondii antibody levels were assessed in serum (s) and aqueous humour (ah) by indirect immunofluorescence assay (IFA), modified agglutination test (MAT), m-ELISA (using crude membranes from T. gondii tachyzoites as antigen) and r-ELISA (using rhoptries from T. gondii tachyzoites as antigen). Polymerase chain reactions (PCR) of samples from the retina were performed by using Tox4 and Tox5 primers. Antibody titers of G1 animals ranged from 128 to 1024 and from 16 to 256 in serum and aqueous humour, respectively. There were differences in the correlation coefficients between IFA(s) × IFA (ah) (r = 0.62, P = 0.05), MAT(s) × MAT (ah) (r = 0.97, P < 0.0001); however, there was no significant difference between r-ELISA(s) × r-ELISA (ah) (r = 0.14, P = 0.7). Antibodies present in serum and aqueous humour recognized similar antigens. Samples of retina were positive by PCR in 30% (3/10) of infected pigs. G2 animals remained without antibody levels and were PCR negative throughout the experiment. These results suggest that the use of a combination of tests and immunoblotting for paired aqueous humour and serum samples could improve the sensitivity and specificity for the diagnosis of ocular toxoplasmosis. © 2007 Elsevier Ltd. All rights reserved.
Resumo:
Aim: This in vitro study evaluated the accuracy of primary incisor lengths determined by digital and conventional radiography compared to the actual tooth length. Methods: Twenty extracted primary maxillary incisors were mounted in acrylic blocks. Tooth length was estimated by using a straight-line measurement provided by the distance measurement tool of a digital dental imaging system (Computed Dental Radiography, Schick Technologies Inc.) and conventional E-speed film radiographs by using a digital caliper. Two operators familiar with both radiographic methods performed the estimates. The estimated tooth lengths were compared to the actual tooth lengths measured with the digital caliper. Data were statistically analyzed by Dahlberg's equation, paired t test, Pearson's correlation coefficient and ANOVA at 5% significance level. Results: There were no statistically significant differences (p = 0.85) between tooth length estimated on digital and conventional radiographs. Admitting as clinically acceptable a 0.5-mm discrepancy between the actual tooth lengths and the radiographically estimated lengths, 60% of the radiographic measurements were considered as accurate. When the acceptable difference range was 1.0 mm, the accuracy of the radiographic measurements increased to 100%. Conclusions: Digital and conventional radiography provided similar tooth length measurements and were equivalent to the actual tooth lengths.
Resumo:
The equations and extrapolation use to localities whose characteristics of soil and climate, even if partial, distinguish the town to which they were generated, still permeate in studies to estimate the rainfall erosivity (EI 30). This work has objective to propose and validate mathematical equations to estimate the rainfall erosivity of two cities of Sao Paulo State's. The adjusted to estimate obtaining and validate data of equations of erosivity (EI 30) according to values of coefficient of rain (Rc) were obtained from pluviographic and pluviometric rainfall data, respectively, using of distinct historical rainfall series. Mutiple comparisions test and confidence intervals were performed to compare absolute average of EI 30, pluviometric data (Pp), and Rc. The correlation between EI 30 and Rc was verified by of Pearson correlation coefficient. Test of the hypothesis of equality between population variance was used to compare the equations. Pluviometrics data of historical series rainfall data different than those that the models were generated were used to validate and to assess the performance of the equations, proposed of this study and compare them with another equation already consolidated in literature. The results show that for the conditions under which the study was conducted, the simple linear equations, shown to be the most appropriate to estimate the rainfall erosivity these two cities. According to the test of the hypothesis of equality variances between populations, the equations adjusted for each city differ statistically so that the rainfall erosivity of each city must be estimated by their respective equation.
Resumo:
Objective: To evaluate the intraexaminer reproducibility of static anthropometric measurements of undergraduate dental students as well as the characteristics and regulating measurements of the dental stools used by them. Methods: Forty volunteers and 6 types of dental stools were evaluated. For the anthropometric measurements the employed equipments were: an adapted office chair, aflexible measuring tape with two adapted rods, a metallic device with a 90 degree central angle, string, a 35 x 24 cm rectangular wooden board, isolating tape and crepe tape. In order to standardize the position of the adapted office chair and the volunteers' feet, the floor was marked with the isolating and crepe tapes. A string was attached to the waist of each volunteer to mark the area corresponding to the kidney region making it possible to measure the seat-renal region area. The examined anthropometric measurements were height, trunkcephalic heigh, sacral-popliteal distance (OK?), hip width, popliteal height and the seat-renal region height. The evaluated characteristics of the dental stools relative to the seat were depth, horizontal width and minimum/maximum height. The back of the dental stool was evaluated as for the minimum/ maximum height adjustment. The anthropometric and dental stool measurements were obtained by a single examiner at two moments with a 1-week interval between the evaluations. Intra-class correlation coefficient (ρ) was used to estimate the intraexaminer reproducibility. Results: Excellent reproducibility was observed for all anthropometric measurements obtained (ρ=0.99) as well as for all dental stools evaluated (ρ=0.99). Conclusion: The method used to obtain the anthropometric and dental stools measurements was reproducible and can be used reliably.
Resumo:
Background and aims. Disease is influenced by the nutritional status of the individual. We have assessed the relationship between nutritional status and food intake among recently hospitalised older people. Methods. A cross-sectional study was undertaken with 240 older people in a hospital that provides care for the public and private healthcare systems. Nutritional status was classified by the MNA (Mini Nutritional Assessment) into: malnourished, risk of malnutrition and without malnutrition. Food intake was estimated by the reported food intake during a typical day. The Kruskal-Wallis test was used to compare the medians and the correlation coefficient of Spearman to verify the relationship between the consumption of energy, protein and vitamin C and MNA scores. Results. 33.8% were classified as adequate regarding nutritional status; 37.1% were classified as being at risk of malnutrition and 29.1% were classified as malnourished. The malnourished individuals reported significantly less energy and nutrient intake than those at risk of malnutrition or those without malnutrition (P=0.001). Not all nutrient intake, just some (iron, cholesterol and fibre), were lower in malnourished people. Conclusions and implications for practice. Deterioration of the nutritional status of older people is accompanied by a reduction in energy and some nutrient intake. The investigation of food intake in older people could provide important information about nutritional risk. © 2010 Blackwell Publishing Ltd.
Resumo:
Albumin concentrations in female Bronze turkeys were compared using agarose gel electrophoresis (AGE) and the bromocresol green (BCG) dye-binding method. The correlation coefficient observed for albumin in the BCG and AGE methods was low, and statistical differences were observed at paired t test (p < 0. 0001). Compared with electrophoresis, the BCG-binding method yielded significantly lower albumin values for female turkeys during laying season. © 2011 Springer-Verlag London Limited.