965 resultados para Z-SCAN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical investigations of superheavy elements in the gas-phase, i.e. elements with Z≥104Z≥104, allow assessing the influence of relativistic effects on their chemical properties. Furthermore, for some superheavy elements and their compounds quite unique gas-phase chemical properties were predicted. The experimental verification of these properties yields supporting evidence for a firm assignment of the atomic number. Prominent examples are the high volatility observed for HsO4 or the very weak interaction of Cn with gold surfaces. The unique properties of HsO4 were exploited to discover the doubly-magic even–even nucleus 270Hs and the new isotope 271Hs. The combination of kinematic pre-separation and gas-phase chemistry allowed gaining access to a new class of relatively fragile compounds, the carbonyl complexes of elements Sg through Mt. A not yet resolved issue concerns the interaction of Fl with gold surfaces. While competing experiments agree on the fact that Fl is a volatile element, there are discrepancies concerning its adsorption on gold surfaces with respect to its daughter Cn. The elucidation of these and other questions amounts to the fascination that gas-phase chemical investigations exert on current research at the extreme limits of chemistry today.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Welsch (Projektbearbeiter): Bewilligung der böhmischen Märzforderungen: Gleichberechtigung der tschechischen mit der deutschen Sprache in Verwaltung und Unterricht, Einberufung einer Volksvertretung auf breiter Grundlage (aktives Wahlrecht 25, passives 30 Jahre), Einrichtung einer verantwortlichen Zentralbehörde in Prag. Des weiteren: Völlige, jedoch nicht entschädigungslose Aufhebung des Robots (Frondienst), Gewährung der Judenemanzipation, der Presse- und persönlichen Freiheit sowie des Petitionsrechts, Besetzung der Ämter und Gerichte nur mit zweisprachigen Beamten, Bewilligung einer böhmischen Nationalgarde. Inaussichtstellung der Aufhebung der Patrimonialgerichtsbarkeit; die geforderte Vereinigung der Länder Böhmen, Mähren und Österreichisch-Schlesien soll auf dem kommenden Reichstag erörtert werden

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Welsch (Projektbearbeiter): Bekräftigung der Kundmachung vom Vortag, daß Arbeiter, die das 24. Lebensjahr vollendet haben zu den Wahlen der Abgeordneten zum konstituierenden Reichstag berechtigt sind

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Welsch (Projektbearbeiter): Die Urwähler sind auch zur Wahl solcher Wahlmänner berechtigt, die in einem anderen als dem eigenen Distrikt aufgestellt wurden

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Welsch (Projektbearbeiter): Dementierung von Gerüchten über die Verwendung von Frauen als Krankenpflegerinnen oder Wäscherinnen in den oberitalienischen Spitälern der österreichischen Armee

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Welsch (Projektbearbeiter): Zurückstellungen vom Dienst sind im Falle eines Alarms aufgehoben, bedürftige Gardisten, die länger als 12 Stunden in einem fremden Bezirk Dienst tun, haben Anspruch auf einen Verpflegungsbeitrag und solche, die während des Dienstes verunglücken auf Versorgung. Zuwiderhandelnde riskieren ein Verbot, ihre Waffen weiterhin zu tragen

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Welsch (Projektbearbeiter): Verbot der Ausfuhr von Uniformteilen, Waffen und Munition in das aufständische Ungarn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the role of an ultra-low-dose dual-source CT coronary angiography (CTCA) scan with high pitch for delimiting the range of the subsequent standard CTCA scan. METHODS 30 patients with an indication for CTCA were prospectively examined using a two-scan dual-source CTCA protocol (2.0 × 64.0 × 0.6 mm; pitch, 3.4; rotation time of 280 ms; 100 kV): Scan 1 was acquired with one-fifth of the tube current suggested by the automatic exposure control software [CareDose 4D™ (Siemens Healthcare, Erlangen, Germany) using 100 kV and 370 mAs as a reference] with the scan length from the tracheal bifurcation to the diaphragmatic border. Scan 2 was acquired with standard tube current extending with reduced scan length based on Scan 1. Nine central coronary artery segments were analysed qualitatively on both scans. RESULTS Scan 2 (105.1 ± 10.1 mm) was significantly shorter than Scan 1 (127.0 ± 8.7 mm). Image quality scores were significantly better for Scan 2. However, in 5 of 6 (83%) patients with stenotic coronary artery disease, a stenosis was already detected in Scan 1 and in 13 of 24 (54%) patients with non-stenotic coronary arteries, a stenosis was already excluded by Scan 1. Using Scan 2 as reference, the positive- and negative-predictive value of Scan 1 was 83% (5 of 6 patients) and 100% (13 of 13 patients), respectively. CONCLUSION An ultra-low-dose CTCA planning scan enables a reliable scan length reduction of the following standard CTCA scan and allows for correct diagnosis in a substantial proportion of patients. ADVANCES IN KNOWLEDGE Further dose reductions are possible owing to a change in the individual patient's imaging strategy as a prior ultra-low-dose CTCA scan may already rule out the presence of a stenosis or may lead to a direct transferal to an invasive catheter procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Book review of Dif-Pradalier, M., & Zarka, Z. (2014). Redonner ses chances à l’apprentissage. Une comparaison France, Suisse, Italie. Pantin: CFTC

Relevância:

20.00% 20.00%

Publicador: