986 resultados para Vocal quartets with piano, 4 hands


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Patients and method Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. Results In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. Conclusion With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of coronal leakage on concentration of hydrogen ions (pH) and calcium release of several calcium hydroxide pastes, over different periods of time. Material and Methods: Fifty extracted human mandibular central incisors (n=10) were instrumented up to the F2 instrument and assigned to the following intracanal dressing: G1- Calen, G2- Calen with 0.4% chlorhexidine (CHX), G3- Calcium hydroxide with camphorated paramonochlorophenol (CPMC) and glycerin, G4- Calen, but temporary filling material maintained during all test (positive control) and G5- Root canal without intracanal dressing (negative control). All groups were immersed in distilled water for 7 days. In sequence, the temporary filling materials were removed, except in controls groups. All specimens were individually mounted on a specific device and only its root again immersed in distilled water. Concentration of hydrogen ions and calcium release by calcium hydroxide pastes in distilled water were evaluated in 24h, 7, 14 and 28 days. The results were submitted to ANOVA test (p = 0.05). After 28 days, root canals from experimental groups were examined in SEM. Results: G1, G2, G3 and G4 presented similar pH values and calcium release and did not differ from each other (p>0.05), up to 7 days. After this time G1, G2 and G3 presented values lower values than G4 (p<0.05). In SEM analysis, calcium hydroxide residues were observed in all experimental groups. Conclusions: After 7 days, coronal leakage decreased the concentration of hydrogen ions and calcium ion release provided by all calcium hydroxide pastes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven. Objective: The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket. Material and Methods: Thirty-two bovine incisors crown blocks of 8 mm x 8 mm height lengths were used. Staining of tooth blocks with black tea was performed for six days. They were distributed randomly into 4 groups (1-home bleaching with bracket, 2- home bleaching without bracket, 3- office bleaching with bracket, 4 office bleaching without bracket). The color evaluation was performed (CIE L * a * b *) using color reflectance spectrophotometer. Metal brackets were bonded in groups 1 and 3. The groups 1 and 2 samples were subjected to the carbamide peroxide at 15%, 4 hours daily for 21 days. Groups 3 and 4 were subjected to 3 in-office bleaching treatment sessions, hydrogen peroxide 38%. After removal of the brackets, the second color evaluation was performed in tooth block, difference between the area under the bracket and around it, and after 7 days to verified color stability. Data analysis was performed using the paired t-test and two-way variance analysis and Tukey’s. Results: The home bleaching technique proved to be more effective compared to the office bleaching. There was a significant difference between the margin and center color values of the specimens that were subjected to bracket bonding. Conclusions: The bracket bond presence affected the effectiveness of both the home and office bleaching treatments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia Animal - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Ideal training methods that could ensure best peritoneal dialysis (PD) outcome have not been defined in previous reports. The aim of the present study was to evaluate the impact of training characteristics on peritonitis rates in a large Brazilian cohort.Methods. Incident patients with valid data on training recruited in the Brazilian Peritoneal Dialysis Multicenter Study (BRAZPD II) from January 2008 to January 2011 were included. Peritonitis was diagnosed according to International Society for Peritoneal Dialysis guidelines; incidence rate of peritonitis (episodes/patient-months) and time to the first peritonitis were used as end points.Results. Two thousand two hundred and forty-three adult patients were included in the analysis: 59 +/- 16 years old, 51.8% female, 64.7% with <= 4 years of education. The median training time was 15 h (IQI 10-20 h). Patients were followed for a median of 11.2 months (range 3-36.5). The overall peritonitis rate was 0.29 per year at risk (1 episode/41 patient-months). The mean number of hours of training per day was 1.8 +/- 2.4. Less than 1 h of training/day was associated with higher incidence rate when compared with the intervals of 1-2 h/day (P = 0.03) and > 2 h/day (P = 0.02). Patients who received a cumulative training of > 15 h had significantly lower incidence of peritonitis compared with < 15 h (0.26 per year at risk versus 0.32 per year at risk, P = 0.01). The presence of a caregiver and the number of people trained were not significantly associated with peritonitis incidence rate. Training in the immediate 10 days after implantation of the catheter was associated with the highest peritonitis rate (0.32 per year), compared with training prior to catheter implantation (0.28 per year) or > 10 days after implantation (0.23 per year). More experienced centers had a lower risk for the first peritonitis (P = 0.003).Conclusions. This is the first study to analyze the association between training characteristics and outcomes in a large cohort of PD patients. Low training time (particularly < 15 h), smaller center size and the timing of training in relation to catheter implantation were associated with a higher incidence of peritonitis. These results support the recommendation of a minimum amount of training hours to reduce peritonitis incidence regardless of the number of hours trained per day.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of inulin and/or okara flour on Lactobacillus acidophilus La-5 and Bifidobacterium animalis Bb-12 viability in a fermented soy product (FSP) and on probiotic survival under in vitro simulated gastrointestinal conditions were investigated throughout 28 days of storage at 4 °C. Employing a 22 design, four FSP trials were produced from soymilk fermented with ABT-4 culture (La-5, Bb-12, and Streptococcus thermophilus): FSP (control); FSP-I (with inulin, 3 g/100 mL of soymilk); FSP-O (with okara, 5 g/100 mL); FSP-IO (with inulin + okara, ratio 3:5 g/100 mL). Probiotic viabilities ranged from 8 to 9 log cfu/g during the 28 days of storage, and inulin and/or okara flour did not affect the viability of La-5 and Bb-12. Bb-12 resistance to the artificial gastrointestinal juices was higher than for La-5, since the Bb-12 and La-5 populations decreased approximately 0.6 log cfu/g and 3.8 log cfu/g, respectively, throughout storage period. Even though the protective effect of inulin and/or okara flour on probiotic microorganisms was not significant, when compared to a fresh culture, the FSP matrix improved Bb-12 survival on day 1 of storage and may be considered a good vehicle for Bb-12 and could play an important role in probiotic protection against gastrointestinal juices. © 2013 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Biopatologia Bucal - ICT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the association among periodontal disease, diabetes mellitus and arterial hypertension in pregnant women users of the Brazilian Health System (SUS). Methods: The sample consisted of 86 women, with pregnant age between the 4th and 7 th month, submitted to pre-natal attendance in Health Basic Unities (HBUs). Periodontal condition was evaluated by 2 calibrated researchers (Kappa = 0.91) through the Community Periodontal Index (CPI). A sphygmomanometer was used to check the arterial pressure, what was accomplished by the professionals from the HBUs; glycemia test was accomplished through a blood sample collected from the middle finger with a disposable lancet adapted to a lance device (Accu-Chek Softclix Pro; Roche, USA), and for checking the glycemia level, a glycemia monitor was used (Accu-Chek Advantage II, Roche, USA). Data were written on a numbered register form, avoiding patient identification. After, the same data were statistically analyzed through the Fisher Exact Test, in order to evaluate the existence of association between the variables blood glucose and periodontal disease. In this test, a significance level of 0,05 was adopted. Results – Most of the pregnant woman presented periodontal health (58,1%); 41,9% of the research subjects showed at least one sign of periodontal disease, with 31,4% presenting gingivitis and 10,5% periodontitis. Hyperglycemia was detected in 51,2% and it was not found a value of arterial pressure higher than what is considered to be normal. Conclusion: it was not verified a significant association among the presence of periodontal disease, glycemia alteration and arterial hypertension in pregnant women who comprised this research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main aim of this paper was to use the REZZ software to calculate the tank volume rainwater harvesting system. For this purpose, rain data of Ponta Grossa-PR-Brazil were used considering different statistical treatment (average, 75%, 85%, 95% and 99% of confidence) and different roof areas (50, 80, 120 and 200 m2). The harvesting system was considered only for toilet flush in households with 3, 4 and 5 inhabitants. There were applied the following methods/concepts: Flow equalization (Rippl); Brazilian method as well the English and German practical methods. Further, the mass-balance was simulated for some conditions. All considered methods are described in NBR15527/07, the Brazilian standard for rainwater harvesting. As expected, the results pointed out for huge differences depending on the choice method and the statistical treatment of the rain data. The REZZ appliance showed to be useful thus permitting to set different conditions and to obtain rapid results in order to assist designers to adopt the best cistern volume for each particular case.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia e Ciência de Alimentos - IBILCE