940 resultados para Ultrasonic atomization
Resumo:
Here, we present a method for measuring barbiturates (butalbital, secobarbital, pentobarbital, and phenobarbital) in whole blood samples. To accomplish these measurements, analytes were extracted by means of hollow-fiber liquid-phase microextraction in the three-phase mode. Hollow-fiber pores were filled with decanol, and a solution of sodium hydroxide (pH 13) was introduced into the lumen of the fiber (acceptor phase). The fiber was submersed in the acidified blood sample, and the system was subjected to an ultrasonic bath. After a 5 min extraction, the acceptor phase was withdrawn from the fiber and dried under a nitrogen stream. The residue was reconstituted with ethyl acetate and trimethylanilinium hydroxide. An aliquot of 1.0 mu L of this solution was injected into the gas chromatograph/mass spectrometer, with the derivatization reaction occurring in the hot injector port (flash methylation). The method proved to be simple and rapid, and only a small amount of organic solvent (decanol) was needed for extraction. The detection limit was 0.5 mu g/mL for all the analyzed barbiturates. The calibration curves were linear over the specified range (1.0 to 10.0 mu g/mL). This method was successfully applied to postmortem samples (heart blood and femoral blood) collected from three deceased persons previously exposed to barbiturates.
Resumo:
This study sought to evaluate the efficacy of passive ultrasonic irrigation (PUI) on removing the smear layer and debris from root dentin using scanning electron microscopy (SEM). Twenty-five bovine incisors were manually prepared and divided into three groups according to the final irrigation protocol: EDTA, final irrigation with 12 mL of 17% EDTA for 3 minutes followed by 5 mL of 2.5% NaOCl; EDTA=PUI, final flush with 4 mL of 17% EDTA and PUI for 30 seconds. These procedures were repeated three times to standardize the volume of the irrigant. Control group, after preparation, the specimens were irrigated only with 17 mL of 2.5% NaOCl. The roots were fractured and analyzed using SEM. The intragroup analysis revealed that the EDTA=PUI protocol removed a higher amount of debris at the cervical third (P 5 0.03). The intergroup analysis revealed that EDTA=PUI presented the lowest amount of debris at the cervical third (P 5 0.007). Smear layer scores were higher in the control group compared with the EDTA and EDTA=PUI groups, but only at the cervical third (P 50.02). None of the final irrigant protocols completely removed the smear layer and debris. EDTA=PUI only improved the removal of debris at the cervical third.
Resumo:
Introduction / objectives The number of orthopedic surgery, especially surgery of total hip and knee, have been more frequent due to technological advances. This study aims to determine the microbial load in the instruments used in clean surgeries, quantifying and identifying the genus and species of microbial growth.Methods Orthopedic surgical instruments were immersed, after use, in sterile water, sonicated in ultrasonic washer and consecutively shaken. Then, the lavage was filtered through a 0.45micron membrane, the result was incubated in aerobic medium, anaerobic medium and medium for fungi and yeasts. Results In clean surgeries, results showed that 47% of used instruments had microbiological growth in the range of 1 to 100 CFU/instrument. The most prevalent organism was Staphylococcus coagulase negative (28%), followed by Bacillus subtilis (11%).This study refuted the hypothesis that clean surgeries happen in micro-organismsfree surgery field. Conclusion The microbiological findings reinforce the importance of antibiotic prophylaxis, practice already well established for this category of surgical procedure.
Resumo:
OBJETIVO: Avaliar a ação precoce do laser terapêutico e do ultrassom no processo de regeneração de uma lesão experimental em ratos. MÉTODO: Utilizou-se 24 ratos. Dezoito foram submetidos ao procedimento cirúrgico de lesão do nervo ciático por compressão, através de uma pinça hemostática acima da fossa poplítea. Os animais foram divididos em três grupos com seis animais em cada. Grupo controle normal. GI: controle lesado sem intervenção terapêutica. GII: intervenção terapêutica do laser ArGaAl. GIII: intervenção terapêutica do ultrassom Pulsado. Iniciamos as intervenções terapêuticas 24 horas após a lesão, com aplicações diárias, por um período de quatorze dias consecutivos. RESULTADOS: Ao avaliar a perimetria dos músculos da coxa direita obteve-se os seguintes valores médios de diminuição (mm), para cada grupo GI: 0,45; GII: 0,42; GIII: 0,40. Quanto ao tempo de deslocamento tanto o GII e GIII apresentaram diferença significativa, quando comparados ao GI. Na avaliação final do IFC o GII sobressaiu ao GIII. Quanto a cicatrização observou-se grande melhora no GII e GIII. CONCLUSÃO: Os resultados evidenciaram que a recuperação nervosa foi maior com a aplicação do laser. Nível de evidência II, Estudos terapêuticos - Investigação dos resultados do tratamento
Resumo:
This paper presents the new active absorption wave basin, named Hydrodynamic Calibrator (HC), constructed at the University of São Paulo (USP), in the Laboratory facilities of the Numerical Offshore Tank (TPN). The square (14 m 14 m) tank is able to generate and absorb waves from 0.5 Hz to 2.0 Hz, by means of 148 active hinged flap wave makers. An independent mechanical system drives each flap by means of a 1HP servo-motor and a ball-screw based transmission system. A customized ultrasonic wave probe is installed in each flap, and is responsible for measuring wave elevation in the flap. A complex automation architecture was implemented, with three Programmable Logic Computers (PLCs), and a low-level software is responsible for all the interlocks and maintenance functions of the tank. Furthermore, all the control algorithms for the generation and absorption are implemented using higher level software (MATLAB /Simulink block diagrams). These algorithms calculate the motions of the wave makers both to generate and absorb the required wave field by taking into account the layout of the flaps and the limits of wave generation. The experimental transfer function that relates the flap amplitude to the wave elevation amplitude is used for the calculation of the motion of each flap. This paper describes the main features of the tank, followed by a detailed presentation of the whole automation system. It includes the measuring devices, signal conditioning, PLC and network architecture, real-time and synchronizing software and motor control loop. Finally, a validation of the whole automation system is presented, by means of the experimental analysis of the transfer function of the waves generated and the calculation of all the delays introduced by the automation system.
Resumo:
INTRODUCTION – In human medicine, diabetes mellitus (DM), hypertension, proteinuria and nephropathy are often associated although it is still not clear whether hypertension is the consequence or the cause of nephropathy and albuminuria. Microalbuminuria, in humans, is an early and sensitive marker which permits timely and effective therapy in the early phase of renal damage. Conversely, in dogs, these relationships were not fully investigated, even though hypertension has been associated with many diseases (Bodey and Michell, 1996). In a previous study, 20% of diabetic dogs were found proteinuric based on a U:P/C > 1 and 46% were hypertensive; this latter finding is similar to the prevalence of hypertension in diabetic people (40-80%) (Struble et al., 1998). In the same canine study, hypertension was also positively correlated with the duration of the disease, as is the case in human beings. Hypertension was also found to be a common complication of hypercortisolism (HC) in dogs, with a prevalence which varies from 50 (Goy-Thollot et al., 2002) to 80% (Danese and Aron, 1994).The aim of our study was to evaluate the urinary albumin to creatinine ratio (U:A/C) in dogs affected by Diabetes Mellitus and HC in order to ascertain if, as in human beings, it could represent an early and more sensitive marker of renal damage than U:P/C. Furthermore, the relationship between proteinuria and hypertension in DM and HC was also investigated. MATERIALS AND METHODS – Twenty dogs with DM, 14 with HC and 21 healthy dogs (control group) were included in the prospective case-control study. Inclusion criteria were hyperglycaemia, glicosuria and serum fructosamine above the reference range for DM dogs and a positive ACTH stimulation test and/or low-dose dexamethasone test and consistent findings of HC on abdominal ultrasonography in HC dogs. Dogs were excluded if affected by urinary tract infections and if the serum creatinine or urea values were above the reference range. At the moment of inclusion, an appropriate therapy had already been instituted less than 1 month earlier in 12 diabetic dogs. The control dogs were considered healthy based on clinical exam and clinicopathological findings. All dogs underwent urine sample collection by cystocentesis and systemic blood pressure measurement by means of either an oscillometric device (BP-88 Next, Colin Corporation, Japan) or by Doppler ultrasonic traducer (Minidop ES-100VX, Hadeco, Japan). The choice of method depended on the dog’s body weight: Doppler ultrasonography was employed in dogs < 20 kg of body weight and the oscillometric method in the other subjects. Dogs were considered hypertensive whenever systemic blood pressure was found ≥ 160 mmHg. The urine was assayed for U:P/C and U:A/C (Gentilini et al., 2005). The data between groups were compared using the Mann-Whitney U test. The reference ranges for U:P/C and U:A/C had already been established by our laboratory as 0.6 and 0.05, respectively. U:P/C and U:A/C findings were correlated to systemic blood pressure and Spearman R correlation coefficients were calculated. In all cases, p < 0.05 was considered statistically significant. RESULTS – The mean ± sd urinary albumin concentration in the three groups was 1.79 mg/dl ± 2.18; 20.02 mg/dl ± 43.25; 52.02 mg/dl ± 98.27, in healthy, diabetic and hypercortisolemic dogs, respectively. The urine albumin concentration differed significantly between healthy and diabetic dogs (p = 0.008) and between healthy and HC dogs (p = 0.011). U:A/C values ranged from 0.00 to 0.34 (mean ± sd 0.02 ± 0.07), 0.00 to 6.72 (mean ± sd 0.62 ± 1.52) and 0.00 to 5.52 (mean ± sd 1.27 ± 1.70) in the control, DM and HC groups, respectively; U:P/C values ranged from 0.1 to 0.6 (mean ± sd 0.17 ± 0.15) 0.1 to 6.6 (mean ± sd 0.93 ± 1.15) and 0.2 to 7.1 (mean ± sd 1.90 ± 2.11) in the control, DM and HC groups, respectively. In diabetic dogs, U:A/C was above the reference range in 11 out of 20 dogs (55%). Among these, 5/20 (25%) showed an increase only in the U:A/C ratio while, in 6/20 (30%), both the U:P/C and the U:A/C were abnormal. Among the latter, 4 dogs had already undergone therapy. In subjects affected with HC, U:P/C and U:A/C were both increased in 10/14 (71%) while in 2/14 (14%) only U:A/C was above the reference range. Overall, by comparing U:P/C and U:A/C in the various groups, a significant increase in protein excretion in disease-affected animals compared to healthy dogs was found. Blood pressure (BP) in diabetic subjects ranged from 88 to 203 mmHg (mean ± sd 143 ± 33 mmHg) and 7/20 (35%) dogs were found to be hypertensive. In HC dogs, BP ranged from 116 to 200 mmHg (mean ± sd 167 ± 26 mmHg) and 9/14 (64%) dogs were hypertensive. Blood pressure and proteinuria were not significantly correlated. Furthermore, in the DM group, U:P/C and U:A/C were both increased in 3 hypertensive dogs and 2 normotensive dogs while the only increase of U:A/C was observed in 2 hypertensive and 3 normotensive dogs. In the HC group, the U:P/C and the U:A/C were both increased in 6 hypertensive and 2 normotensive dogs; the U:A/C was the sole increased parameter in 1 hypertensive dog and in 1 dog with normal pressure. DISCUSSION AND CONCLUSION- The findings of this study suggest that, in dogs affected by DM and HC, an increase in U:P/C, U:A/C and systemic hypertension is frequently present. Remarkably, some dogs affected by both DM and HC showed an U:A/C but not U:P/C above the reference range. In diabetic dogs, albuminuria was observed in 25% of the subjects, suggesting the possibility that this parameter could be employed for detecting renal damage at an early phase when common semiquantiative tests and even U:P/C fall inside the reference range. In HC dogs, a higher number of subjects with overt proteinuria was found while only 14% presented an increase only in the U:A/C. This fact, associated with a greater number of hypertensive dogs having HC rather than DM, could suggest a greater influence on renal function by the mechanisms involved in hypertension secondary to hypercortisolemia. Furthermore, it is possible that, in HC dogs, the diagnosis was more delayed than in DM dogs. However, the lack of a statistically significant correlation between hypertension and increased protein excretion as well as the apparently random distribution of proteinuric subjects in normotensive and hypertensive cases, imply that other factors besides hypertension are involved in causing proteinuria. Longitudinal studies are needed to further investigate the relationship between hypertension and proteinuria.
Resumo:
Statistical modelling and statistical learning theory are two powerful analytical frameworks for analyzing signals and developing efficient processing and classification algorithms. In this thesis, these frameworks are applied for modelling and processing biomedical signals in two different contexts: ultrasound medical imaging systems and primate neural activity analysis and modelling. In the context of ultrasound medical imaging, two main applications are explored: deconvolution of signals measured from a ultrasonic transducer and automatic image segmentation and classification of prostate ultrasound scans. In the former application a stochastic model of the radio frequency signal measured from a ultrasonic transducer is derived. This model is then employed for developing in a statistical framework a regularized deconvolution procedure, for enhancing signal resolution. In the latter application, different statistical models are used to characterize images of prostate tissues, extracting different features. These features are then uses to segment the images in region of interests by means of an automatic procedure based on a statistical model of the extracted features. Finally, machine learning techniques are used for automatic classification of the different region of interests. In the context of neural activity signals, an example of bio-inspired dynamical network was developed to help in studies of motor-related processes in the brain of primate monkeys. The presented model aims to mimic the abstract functionality of a cell population in 7a parietal region of primate monkeys, during the execution of learned behavioural tasks.
Resumo:
ABSTRACT: The dimension stone qualification through the use of non-destructive tests (NDT) is a relevant research topic for the industrial characterisation of finite products, because the competition of low-costs products can be sustained by an offer of highqualification and a top-guarantee products. The synthesis of potentialities offered by the NDT is the qualification and guarantee similar to the well known agro-industrial PDO, Protected Denomination of Origin. In fact it is possible to guarantee both, the origin and the quality of each stone product element, even through a Factory Production Control on line. A specific disciplinary is needed. A research developed at DICMA-Univ. Bologna in the frame of the “OSMATER” INTERREG project, allowed identifying good correlations between destructive and non-destructive tests for some types of materials from Verbano-Cusio-Ossola region. For example non conventional ultrasonic tests, image analysis parameters, water absorption and other measurements showed to be well correlated with the bending resistance, by relationships varying for each product. In conclusion it has been demonstrated that a nondestructive approach allows reaching several goals, among the most important: 1) the identification of materials; 2) the selection of products; 3) the substitution of DT by NDT. Now it is necessary to move from a research phase to the industrial implementation, as well as to develop new ND technologies focused on specific aims.
Resumo:
The Székesfehérvár Ruin Garden is a unique assemblage of monuments belonging to the cultural heritage of Hungary due to its important role in the Middle Ages as the coronation and burial church of the Kings of the Hungarian Christian Kingdom. It has been nominated for “National Monument” and as a consequence, its protection in the present and future is required. Moreover, it was reconstructed and expanded several times throughout Hungarian history. By a quick overview of the current state of the monument, the presence of several lithotypes can be found among the remained building and decorative stones. Therefore, the research related to the materials is crucial not only for the conservation of that specific monument but also for other historic structures in Central Europe. The current research is divided in three main parts: i) description of lithologies and their provenance, ii) physical properties testing of historic material and iii) durability tests of analogous stones obtained from active quarries. The survey of the National Monument of Székesfehérvár, focuses on the historical importance and the architecture of the monument, the different construction periods, the identification of the different building stones and their distribution in the remaining parts of the monument and it also included provenance analyses. The second one was the in situ and laboratory testing of physical properties of historic material. As a final phase samples were taken from local quarries with similar physical and mineralogical characteristics to the ones used in the monument. The three studied lithologies are: fine oolitic limestone, a coarse oolitic limestone and a red compact limestone. These stones were used for rock mechanical and durability tests under laboratory conditions. The following techniques were used: a) in-situ: Schmidt Hammer Values, moisture content measurements, DRMS, mapping (construction ages, lithotypes, weathering forms) b) laboratory: petrographic analysis, XRD, determination of real density by means of helium pycnometer and bulk density by means of mercury pycnometer, pore size distribution by mercury intrusion porosimetry and by nitrogen adsorption, water absorption, determination of open porosity, DRMS, frost resistance, ultrasonic pulse velocity test, uniaxial compressive strength test and dynamic modulus of elasticity. The results show that initial uniaxial compressive strength is not necessarily a clear indicator of the stone durability. Bedding and other lithological heterogeneities can influence the strength and durability of individual specimens. In addition, long-term behaviour is influenced by exposure conditions, fabric and, especially, the pore size distribution of each sample. Therefore, a statistic evaluation of the results is highly recommended and they should be evaluated in combination with other investigations on internal structure and micro-scale heterogeneities of the material, such as petrographic observation, ultrasound pulse velocity and porosimetry. Laboratory tests used to estimate the durability of natural stone may give a good guidance to its short-term performance but they should not be taken as an ultimate indication of the long-term behaviour of the stone. The interdisciplinary study of the results confirms that stones in the monument show deterioration in terms of mineralogy, fabric and physical properties in comparison with quarried stones. Moreover stone-testing proves compatibility between quarried and historical stones. Good correlation is observed between the non-destructive-techniques and laboratory tests results which allow us to minimize sampling and assessing the condition of the materials. Concluding, this research can contribute to the diagnostic knowledge for further studies that are needed in order to evaluate the effect of recent and future protective measures.
Resumo:
Aim of this thesis was the production of porosity-graded piezoelectric ceramics for ultrasonic applications by tape casting and screen printing. The study and optimization of each single step of the tape casting process allowed to produce flat and crack-free multilayers of Pb0.988(Zr0.52Ti0.48)0.976Nb0.024O3 (PZTN) of uniform and graded porosity. The multilayers of thickness ranging between 400 and 800 µm were produced stacking optimized green layers with different amount of pore former. The functionally graded materials showed porosity ranging between 10 and 30% with piezoelectric properties suitable for the specific ultrasonic applications. Screen printing inks of PZTN for deposition onto four different substrates were studied and optimized. Thick films with thickness ranging between 4 and 20 µm were produced tailoring the screen printing parameters and number of depositions.
Resumo:
In gasoline Port Fuel Injection (PFI) and Direct Injection (GDI) internal combustion engines, the liquid fuel might be injected into a gaseous ambient in a superheated state, resulting in flash boiling of the fuel. The importance to investigate and predict such a process is due to the influence it has on the liquid fuel atomization and vaporization and thus on combustion, with direct implications on engine performances and exhaust gas emissions. The topic of the present PhD research involves the numerical analysis of the behaviour of the superheated fuel during the injection process, in high pressure injection systems like the ones equipping GDI engines. Particular emphasis is on the investigation of the effects of the fuel superheating degree on atomization dynamics and spray characteristics. The present work is a look at the flash evaporation and flash boiling modeling, from an engineering point of view, addressed to keep the complex physics involved as simple as possible, however capturing the main characteristics of a superheated fuel injection.
Resumo:
Monitoring foetal health is a very important task in clinical practice to appropriately plan pregnancy management and delivery. In the third trimester of pregnancy, ultrasound cardiotocography is the most employed diagnostic technique: foetal heart rate and uterine contractions signals are simultaneously recorded and analysed in order to ascertain foetal health. Because ultrasound cardiotocography interpretation still lacks of complete reliability, new parameters and methods of interpretation, or alternative methodologies, are necessary to further support physicians’ decisions. To this aim, in this thesis, foetal phonocardiography and electrocardiography are considered as different techniques. Further, variability of foetal heart rate is thoroughly studied. Frequency components and their modifications can be analysed by applying a time-frequency approach, for a distinct understanding of the spectral components and their change over time related to foetal reactions to internal and external stimuli (such as uterine contractions). Such modifications of the power spectrum can be a sign of autonomic nervous system reactions and therefore represent additional, objective information about foetal reactivity and health. However, some limits of ultrasonic cardiotocography still remain, such as in long-term foetal surveillance, which is often recommendable mainly in risky pregnancies. In these cases, the fully non-invasive acoustic recording, foetal phonocardiography, through maternal abdomen, represents a valuable alternative to the ultrasonic cardiotocography. Unfortunately, the so recorded foetal heart sound signal is heavily loaded by noise, thus the determination of the foetal heart rate raises serious signal processing issues. A new algorithm for foetal heart rate estimation from foetal phonocardiographic recordings is presented in this thesis. Different filtering and enhancement techniques, to enhance the first foetal heart sounds, were applied, so that different signal processing techniques were implemented, evaluated and compared, by identifying the strategy characterized on average by the best results. In particular, phonocardiographic signals were recorded simultaneously to ultrasonic cardiotocographic signals in order to compare the two foetal heart rate series (the one estimated by the developed algorithm and the other provided by cardiotocographic device). The algorithm performances were tested on phonocardiographic signals recorded on pregnant women, showing reliable foetal heart rate signals, very close to the ultrasound cardiotocographic recordings, considered as reference. The algorithm was also tested by using a foetal phonocardiographic recording simulator developed and presented in this research thesis. The target was to provide a software for simulating recordings relative to different foetal conditions and recordings situations and to use it as a test tool for comparing and assessing different foetal heart rate extraction algorithms. Since there are few studies about foetal heart sounds time characteristics and frequency content and the available literature is poor and not rigorous in this area, a data collection pilot study was also conducted with the purpose of specifically characterising both foetal and maternal heart sounds. Finally, in this thesis, the use of foetal phonocardiographic and electrocardiographic methodology and their combination, are presented in order to detect foetal heart rate and other functioning anomalies. The developed methodologies, suitable for longer-term assessment, were able to detect heart beat events correctly, such as first and second heart sounds and QRS waves. The detection of such events provides reliable measures of foetal heart rate, potentially information about measurement of the systolic time intervals and foetus circulatory impedance.
Resumo:
Sekundäres organisches Aerosol (SOA) ist ein wichtiger Bestandteil von atmosphärischen Aerosolpartikeln. Atmosphärische Aerosole sind bedeutsam, da sie das Klima über direkte (Streuung und Absorption von Strahlung) und indirekte (Wolken-Kondensationskeime) Effekte beeinflussen. Nach bisherigen Schätzungen ist die SOA-Bildung aus biogenen Kohlenwasserstoffen global weit wichtiger als die SOA-Bildung aus anthropogenen Kohlenwasserstoffen. Reaktive Kohlenwasserstoffe, die in großen Mengen von der Vegetation emittiert werden und als die wichtigsten Vorläufersubstanzen für biogenes SOA gelten, sind die Terpene. In der vorliegenden Arbeit wurde eine Methode entwickelt, welche die Quantifizierung von aciden Produkten der Terpen-Oxidation ermöglicht. Die Abscheidung des größenselektierten Aerosols (PM 2.5) erfolgte auf Quarzfilter, die unter Zuhilfenahme von Ultraschall mittels Methanol extrahiert wurden. Nach Aufkonzentrierung und Lösungsmittelwechsel auf Wasser sowie Standardaddition wurden die Proben mit einer Kapillar-HPLC-ESI-MSn-Methode analysiert. Das verwendete Ionenfallen-Massenspektrometer (LCQ-DECA) bietet die Möglichkeit, Strukturaufklärung durch selektive Fragmentierung der Qasimolekülionen zu betreiben. Die Quantifizierung erfolgte teilweise im MS/MS-Modus, wodurch Selektivität und Nachweisgrenze verbessert werden konnten. Um Produkte der Terpen-Oxidation zu identifizieren, die nicht als Standards erhältlich waren, wurden Ozonolysexperimente durchgeführt. Dadurch gelang die Identifizierung einer Reihe von Oxidationsprodukten in Realproben. Neben schon bekannten Produkten der Terpen-Oxidation konnten einige Produkte erstmals in Realproben eindeutig als Produkte des α Pinens nachgewiesen werden. In den Proben der Ozonolyseexperimente konnten auch Produkte mit hohem Molekulargewicht (>300 u) nachgewiesen werden, die Ähnlichkeit zeigen zu den als Dimeren oder Polymeren in der Literatur bezeichneten Substanzen. Sie konnten jedoch nicht in Feldproben gefunden werden. Im Rahmen von 5 Messkampagnen in Deutschland und Finnland wurden Proben der atmosphärischen Partikelphase genommen. Die Quantifizierung von Produkten der Oxidation von α-Pinen, β-Pinen, 3-Caren, Sabinen und Limonen in diesen Proben ergab eine große zeitliche und örtliche Variationsbreite der Konzentrationen. Die Konzentration von Pinsäure bewegte sich beispielsweise zwischen etwa 0,4 und 21 ng/m³ während aller Messkampagnen. Es konnten stets Produkte verschiedener Terpene nachgewiesen werden. Produkte einiger Terpene eignen sich sogar als Markersubstanzen für verschiedene Pflanzenarten. Sabinen-Produkte wie Sabinsäure können als Marker für die Emissionen von Laubbäumen wie Buchen oder Birken verwendet werden, während Caren-Produkte wie Caronsäure als Marker für Nadelbäume, speziell Kiefern, verwendet werden können. Mit den quantifizierten Substanzen als Marker wurde unter zu Hilfenahme von Messungen des Gehaltes an organischem und elementarem Kohlenstoff im Aerosol der Anteil des sekundären organischen Aerosols (SOA) errechnet, der von der Ozonolyse der Terpene stammt. Erstaunlicherweise konnten nur 1% bis 8% des SOA auf die Ozonolyse der Terpene zurückgeführt werden. Dies steht im Gegensatz zu der bisherigen Meinung, dass die Ozonolyse der Terpene die wichtigste Quelle für biogenes SOA darstellt. Gründe für diese Diskrepanz werden in der Arbeit diskutiert. Um die atmosphärischen Prozesse der Bildung von SOA vollständig zu verstehen, müssen jedoch noch weitere Anstrengungen unternommen werden.
Resumo:
Die vorliegende Dissertation beschreibt die Entwicklung, den Aufbau und die Erprobung eines neuartigen lasermassenspektrometrischen Nachweises des Ultraspurenisotops 236U. Das Nuklid 236U wird vorwiegend in Kernreaktoren durch Neutroneneinfang aus 235U gebildet und dient damit als Schlüsselisotop zur Unterscheidung anthropogenen Urans von natürlichem Uran-Vorkommen. Mit seinem Nachweis wird die Untersuchung der Migration von Kernbrennstoff in der Umwelt und die Beantwortung kritischer Fragen in der nuklearen Forensik ermöglicht. Im Rahmen dieser Arbeit wurde das Verfahren der hochauflösenden Resonanzionisations-Massenspektrometrie auf die Anforderungen des selektiven Nachweises von Uran-Isotopen angepasst. Wesentliche Schritte waren hierbei die Untersuchung einer effizienten Atomisation von Uran-Proben, die Identifikation atomarer und autoionisierender Zustände für eine resonante Anregungsleiter, die vollständige Spezifikation der Anregungsleiter für alle Uran-Isotope und schließlich die Umsetzung der Erkenntnisse in ein analytisches Messverfahren. Die optische Selektivität des Verfahrens konnte durch Dichtematrixrechnungen zu ca. 14 Größenordnungen abgeschätzt werden; die Nachweisgrenze des Verfahrens für das Isotopenverhältnis 236U / 238U ist dabei gegenwärtig durch Untergrund begrenzt und beträgt ca. 3 · 10−8. Mit diesen Spezifikationen konnte die Linearität und Präzision des Nachweisverfahrens über einen dynamischen Bereich von vier Größenordnungen nachgewiesen werden.
Resumo:
Introduction Lower pole kidney stones represent at time a challenge for the urologist. The gold standard treatment for intrarenal stones <2 cm is Extracorporeal Shock Wave Lithotripsy (ESWL) while for those >2 cm is Percutaneous Nephrolithotomy (PCNL). The success rate of ESWL, however, decreases when it is employed for lower pole stones, and this is particularly true in the presence of narrow calices or acute infundibular angles. Studies have proved that ureteroscopy (URS) is an efficacious alternative to ESWL for lower pole stones <2 cm, but this is not reflected by either the European or the American guidelines. The aim of this study is to present the results of a large series of flexible ureteroscopies and PCNLs for lower pole kidney stones from high-volume centers, in order to provide more evidences on the potential indications of the flexible ureteroscopy for the treatment of kidney stones. Materials and Methods A database was created and the participating centres retrospectively entered their data relating to the percutaneous and flexible ureteroscopic management of lower pole kidney stones. Patients included were treated between January 2005 and January 2010. Variables analyzed included case load number, preoperative and postoperative imaging, stone burden, anaesthesia (general vs. spinal), type of lithotripter, access location and size, access dilation type, ureteral access sheath use, visual clarity, operative time, stone-free rate, complication rate, hospital stay, analgesic requirement and follow-up time. Stone-free rate was defined as absence of residual fragments or presence of a single fragment <2 mm in size at follow-up imaging. Primary end-point was to test the efficacy and safety of flexible URS for the treatment of lower pole stones; the same descriptive analysis was conducted for the PCNL approach, as considered the gold standard for the treatment of lower pole kidney stones. In this setting, no statistical analysis was conducted owing to the different selection criteria of the patients. Secondary end-point consisted in matching the results of stone-free rates, operative time and complications rate of flexible URS and PCNL in the subgroup of patients harbouring lower pole kidney stones between 1 and 2 cm in the higher diameter. Results A total 246 patients met the criteria for inclusion. There were 117 PCNLs (group 1) and 129 flexible URS (group 2). Ninety-six percent of cases were diagnosed by CT KUB scan. Mean stone burden was 175±160 and 50±62 mm2 for groups 1 and 2, respectively. General anaesthesia was induced in 100 % and 80% of groups 1 and 2, respectively. Pneumo-ultrasonic energy was used in 84% of cases in the PCNL group, and holmium laser in 95% of the cases in the flexible URS group. The mean operative time was 76.9±44 and 63±37 minutes for groups 1 and 2 respectively. There were 12 major complications (11%) in group 1 (mainly Grade II complications according to Clavidien classification) and no major complications in group 2. Mean hospital stay was 5.7 and 2.6 days for groups 1 and 2, respectively. Ninety-five percent of group 1 and 52% of group 2 required analgesia for a period longer than 24 hours. Intraoperative stone-free rate after a single treatment was 88.9% for group 1 and 79.1% for group 2. Overall, 6% of group 1 and 14.7% of group 2 required a second look procedure. At 3 months, stone-free rates were 90.6% and 92.2% for groups 1 and 2, respectively, as documented by follow-up CT KUB (22%) or combination of intra-venous pyelogram, regular KUB and/or kidney ultrasound (78%). In the subanalysis conducted comparing 82 vs 65 patients who underwent PCNL and flexible URS for lower pole stones between 1 and 2 cm, intreoperative stone-free rates were 88% vs 68% (p= 0.03), respectively; anyway, after an auxiliary procedure which was necessary in 6% of the cases in group 1 and 23% in group 2 (p=0.03), stone-free rates at 3 months were not statistically significant (91.5% vs 89.2%; p=0.6). Conversely, the patients undergoing PCNL maintained a higher risk of complications during the procedure, with 9 cases observed in this group versus 0 in the group of patients treated with URS (p=0.01) Conclusions These data highlight the value of flexible URS as a very effective and safe option for the treatment of kidney stones; thanks to the latest generation of flexible devices, this new technical approach seems to be a valid alternative in particular for the treatment of lower pole kidney stones less than 2 cm. In high-volume centres and in the hands of skilled surgeons, this technique can approach the stone-free rates achievable through PCNL in lower pole stones between 1 and 2 cm, with a very low risk of complications. Furthermore, the results confirm the high success rate and relatively low morbidity of modern PCNL for lower pole stones, with no difference detectable between the prone and supine position.