983 resultados para Thoracic Extradural Analgesia
Resumo:
The health status of previously premature neonates after closure of a patent ductus arteriosus (PDA) was analyzed in childhood and adolescence. Physician questionnaires were used to study 180 hospital survivors among 210 consecutive premature neonates who underwent PDA closure between 1985 and 2005. Complete follow-up data were obtained for 129 patients (72%). During a median follow-up period of 7 years (range, 2-22 years), three late deaths (2.3%) had occurred. Only 45% of the patients were considered healthy. Morbidity included developmental delay (41.1%), pulmonary illness (12.4%), neurologic impairment (14.7%), hearing impairment (3.9%), gastrointestinal disease (3.1%), and thoracic deformity (1.2%). None of the adverse variables during the neonatal period (intraventricular hemorrhage, bradycardia apnea syndrome, bronchopulmonary dysplasia, pulmonary bleeding, hyaline membrane disease, artificial respiration time [continuous positive airway pressure + intubation], or necrotizing enterocolitis) statistically predicted respective system morbidity at the follow-up evaluation. Hyaline membrane disease (odds ratio, 2.5; p = 0.026) and longer hospitalization time (odds ratio, 1.2 days per 10 hospitalization days; p = 0.032) in the newborn period were significant predictors of an unhealthy outcome at the last follow-up evaluation. Survival until childhood after closure of a hemodynamically significant PDA in premature neonates is satisfactory. However, physical and neurodevelopmental co-morbidity persist for half of the patients, perhaps as a sequela of prematurity unrelated to ductus closure.
Resumo:
A 41-year-old woman who worked in a furniture plant was admitted to hospital for acute dyspnea that had developed a few hours she marked pieces of "Alcantara" material with a heated metallic blade. The chest x-ray showed a restrictive syndrome. The lymphocyte count was high in the bronchioalveolar lavage fluid with a CD4/CD8 ratio of 0.11, leading to the diagnosis of alveolitis. Investigations at the work place allowed identification and evaluation of the causal agent. Alcantara is a synthetic fabric composed of 70% polyurethane fibers, which when burned produces isocyanate monomers. After eliminating exposure and institution of corticosteroid therapy, the outcome was good with complete recovery. The risk was eliminated by changing the work procedure. This risk has not been reported earlier for furniture manufacture.
Resumo:
Standard surgical aortic valve replacement with a biological prosthesis remains the treatment of choice for low- and mid-risk elderly patients (traditionally >65 years of age) suffering from severe symptomatic aortic valve stenosis or insufficiency, and for young patients with formal contraindications to long-lasting anticoagulation. Unfortunately, despite the fact that several technical improvements have noticeably improved the resistance of pericardial and bovine bioprostheses to leaflet calcifications and ruptures, the risk of early valve failure with rapid degeneration still exists, especially for patients under haemodialysis and for patients <60 years of age at the time of surgery. Until now, redo open heart surgery under cardiopulmonary bypass and on cardioplegic arrest was the only available therapeutic option in case of bioprosthesis degeneration, but it carried a higher surgical risk when elderly patients with severe concomitant comorbidities were concerned. Since a few years, the advent of new transcatheter aortic valve procedures has opened new horizons in cardiac surgery and, in particular, the possibility of implanting stented valves within the degenerated stented bioprosthesis, the so-called 'valve-in-valve' (VinV) concept, has become a clinical practice in experienced cardiac centres. The VinV procedure represents a minimally invasive approach dedicated to high-risk redo patients, and published preliminary reports have shown a success rate of 100% with absence of significant valvular leaks, acceptable transvalvular gradients and low complication rate. However, this procedure is not riskless and the most important concerns are about the size mismatch and the right positioning within the degenerated bioprosthesis. In this article, we review the limited available literature about VinV procedures, underline important technical details for the positioning and provide guidelines to prevent valve-prosthesis mismatch comparing the three sizes of the only commercially available transapical device, the Edwards Sapien, with the inner diameter of three of the most commonly used stented bioprostheses.
Resumo:
Drosophila pauliceia sp. nov., a spot-thoraxed species closely related to Drosophila boraceia Vilela & Val, 2004, is described from flies collected in an urban remnant of the montane Atlantic Forest located at the Cidade Universitária "Armando de Salles Oliveira", São Paulo city, state of São Paulo, Brazil. The two forest-dwelling species can be externally distinguished mainly by having a different pattern of thoracic spots. A new group of spotted flies (peruensis group) is proposed to include them, in addition to Drosophila peruensis Wheeler, 1959, from Urubamba River, Peru, and Drosophila atalaia Vilela & Sene, 1982, from Brazil and Argentina. To facilitate comparisons, illustrations of the male and female terminalia of the new species and of some unpublished views of those of D. atalaia are included. Additionally, a new group of unspotted species (named caponei group) is proposed to include Drosophila caponei Pavan & Cunha, 1947 and D. neochracea Wheeler, 1959, both previously considered to be related to D. atalaia.
Resumo:
BACKGROUND AND PURPOSE: Multi-phase postmortem CT angiography (MPMCTA) is increasingly being recognized as a valuable adjunct medicolegal tool to explore the vascular system. Adequate interpretation, however, requires knowledge about the most common technique-related artefacts. The purpose of this study was to identify and index the possible artefacts related to MPMCTA. MATERIAL AND METHODS: An experienced radiologist blinded to all clinical and forensic data retrospectively reviewed 49 MPMCTAs. Each angiographic phase, i.e. arterial, venous and dynamic, was analysed separately to identify phase-specific artefacts based on location and aspect. RESULTS: Incomplete contrast filling of the cerebral venous system was the most commonly encountered artefact, followed by contrast agent layering in the lumen of the thoracic aorta. Enhancement or so-called oedematization of the digestive system mucosa was also frequently observed. CONCLUSION: All MPMCTA artefacts observed and described here are reproducible and easily identifiable. Knowledge about these artefacts is important to avoid misinterpreting them as pathological findings.
Resumo:
OBJECTIVE: To determine the means and the reference intervals of the quantitative morphometric parameters of femoroacetabular impingement (FAI) in normal hips with high-resolution computed tomography (CT). METHODS: We prospectively included 94 adult individuals who underwent CT for thoracic, abdominal or urologic pathologies. Patients with a clinical history of hip pathology and/or with osteoarthritis on CT were excluded. We calculated means and 95 % reference intervals for imaging signs of cam-type (alpha angle at 90° and 45° and femoral head-neck offset) and pincer-type impingement (acetabular version angle, lateral centre-edge angle and acetabular index). RESULTS: The 95 % reference interval limits were all far beyond the abnormal thresholds found in the literature for cam-type and to a lesser extent for pincer-type FAI. The upper limits of the reference intervals for the alpha angles (at 90°/45°) were 68°/83° (men) and 69°/84° (women), compared to thresholds from the literature (50°, 55° or 60°). Reference intervals were similar between genders for cam-type parameters, and slightly differed for pincer-type. CONCLUSION: The 95 % reference intervals of morphometric measurements of FAI in asymptomatic hips were beyond the abnormal thresholds, which was especially true for cam-type FAI. Our results suggest the need for redefining the current morphometric parameters used in the diagnosis of FAI. KEY POINTS: ? 95 % reference intervals limits of FAI morphotype were beyond currently defined thresholds. ? Reference intervals of pincer-type morphotype measurements were close to current definitions. ? Reference intervals of cam-type morphotype measurements were far beyond the current definitions. ? Current morphometric definitions of cam-type morphotype should be used with care.
Resumo:
BACKGROUND: Clinical studies suggest that transmyocardial laser revascularization may improve regional blood flow of the subendocardial layer. The vascular growth pattern of laser channels was analyzed. METHODS: Twenty pigs were randomized to undergo ligation of left marginal arteries (n = 5), to undergo transmyocardial laser revascularization of the left lateral wall (n = 5), to undergo both procedures (n = 5) or to a control group (n = 5). All the animals were sacrificed after 1 month. Computed morphometric analysis of vascular density of the involved area was expressed as number of vascular structures per square millimeter (+/-1 standard deviation). RESULTS: The vascular density of the scar tissue of the laser channel was significantly increased in comparison with myocardial infarction alone: 49.6+/-12.8/mm2 versus 25.5+/-8.6/mm2 (p < 0.0001). The vascular densities of subendocardial and subepicardial channel areas were similar: 52.9+/-16.8/mm2 versus 46.3+/-13.6/mm2 (p = 0.41). The area immediately adjacent to the channels showed a vascular density similar to that of normal tissue: 6.02+/-1.7/mm2 versus 5.2+/-1.9/mm2 (p = 0.08). In the infarction + transmyocardial laser revascularization group, the channels were indistinguishable from infarction scar. CONCLUSIONS: Scars of transmyocardial laser revascularization channels exhibit an increased vascular density in comparison with scar tissue of myocardial infarction, which does not extend into their immediate vicinity. There was no vascular density gradient along the longitudinal axis of the channels.
Resumo:
Abstract Purpose: To test the hypothesis that simultaneous closure of at least 2 independent vascular territories supplying the spinal cord and/or prolonged hypotension may be associated with symptomatic spinal cord ischemia (SCI) after thoracic endovascular aortic repair (TEVAR). Methods: A pattern matching algorithm was used to develop a risk model for symptomatic SCI using a prospective 63-patient single-center cohort to test the positive predictive value (PPV) of prolonged intraoperative hypotension and/or simultaneous closure of at least 2 of 4 the vascular territories supplying the spinal cord (left subclavian, intercostal, lumbar, and hypogastric arteries). This risk model was then applied to data extracted from the multicenter European Registry on Endovascular Aortic Repair Complications (EuREC). Between 2002 and 2010, the 19 centers participating in EuREC reported 38 (1.7%) cases of symptomatic spinal cord ischemia among the 2235 patients in the database. Results: In the single-center cohort, direct correlations were seen between the occurrence of symptomatic SCI and both prolonged intraoperative hypotension (PPV 1.00, 95% CI 0.22 to 1.00, p = 0.04) and simultaneous closure of at least 2 independent spinal cord vascular territories (PPV 0.67, 95% CI 0.24 to 0.91, p = 0.005). Previous closure of a single vascular territory was not associated with an increased risk of symptomatic spinal cord ischemia (PPV 0.07, 95% CI 0.01 to 0.16, p = 0.56). The combination of prolonged hypotension and simultaneous closure of at least 2 territories exhibited the strongest association (PPV 0.75, 95% CI 0.38 to 0.75, p<0.0001). Applying the model to the entire EuREC cohort found an almost perfect agreement between the predicted and observed risk factors (kappa 0.77, 95% CI 0.65 to 0.90). Conclusion: Extensive coverage of intercostal arteries alone by a thoracic stent-graft is not associated with symptomatic SCI; however, simultaneous closure of at least 2 vascular territories supplying the spinal cord is highly relevant, especially in combination with prolonged intraoperative hypotension. As such, these results further emphasize the need to preserve the left subclavian artery during TEVAR.
Resumo:
OBJECTIVE: We sought to describe our experience in the management of complex glotto-subglottic stenosis in the pediatric age group. METHODS: Between 1978 and 2008, 33 children with glotto-subglottic stenosis underwent partial cricotracheal resection, and they form the focus of this study. They were compared with 67 children with isolated subglottic stenosis (no glottic involvement). The outcomes measured were need for revision open surgical intervention, delayed decannulation (>6 months), and operation-specific and overall decannulation rates. Fisher's exact test was used for comparison of outcomes. RESULTS: Results of preoperative evaluation showed Myer-Cotton grade III or IV stenosis in 32 (97%) patients and grade II stenosis in 1 patient. All patients with glotto-subglottic stenosis were treated with partial cricotracheal resection and simultaneous repair of the glottic pathology. Bilateral fixed vocal cords were seen in 19 (58%) of 33 patients, bilateral restricted abduction was seen in 7 (21%) of 33 patients, and unilateral fixed vocal cord was seen in 7 (21%) of 33 patients. Ten patients underwent single-stage partial cricotracheal resection with excision of interarytenoid scar tissue. The endotracheal tube was kept for a mean period of 7 days as a stent. Twenty-three patients underwent extended partial cricotracheal resection with LT-Mold (Bredam S.A., St. Sulpice, Switzerland) or T-tube stenting. The overall decannulation rate included 26 (79%) patients, and the operation-specific decannulation rate included 20 (61%) patients. CONCLUSIONS: Glotto-subglottic stenosis is a complex laryngeal injury associated with delayed decannulation and decreased overall and operation-specific decannulation rates when compared with those after subglottic stenosis without glottic involvement after partial cricotracheal resection.
Resumo:
The jointly voluntary and involuntary control of respiration, unique among essential physiological processes, the interconnection of breathing with and its influence on the autonomic nervous system, and disease states associated with the interface between psychology and respiration (e.g., anxiety disorders, hyperventilation syndrome, asthma) make the study of the relationship between respiration and emotion both theoretically and clinically of great relevance. However, the respiratory behavior during affective states is not yet completely understood. We studied breathing pattern responses to 13 picture series varying widely in their affective tone in 37 adults (18 men, 19 women, mean age 26). Time and volume parameters were recorded with the LifeShirt system (VivoMetrics Inc., Ventura, California, USA, see image). We also measured end-tidal pCO2 (EtCO2) with a Microcap Handheld Capnograph (Oridion Medical 1987 Ltd., Jerusalem, Israel) to determine if ventilation is in balance with metabolic demands and spontaneous eye-blinking to investigate the link between respiration and attention. At the end of each picture series, the participants reported their subjective feeling in the affective dimensions of pleasantness and arousal. Increasing self-rated arousal was associated with increasing minute ventilation but not with decreases in EtCO2, suggesting that ventilatory changes during picture viewing paralleled variations in metabolic activity. EtCO2 correlated with pleasantness, and eye-blink rate decreased with increasing unpleasantness in line with a negativity bias in attention. Like MV, inspiratory drive (i.e., mean inspiratory flow) increased with arousal. This relationship reflected increases in inspiratory volume rather than shortening of the time parameters. This study confirms that respiratory responses to affective stimuli are organized to a certain degree along the dimensions of pleasantness and arousal. It shows, for the first time, that during picture viewing, ventilatory increases with increasing arousal are in balance with metabolic activity and that inspiratory volume is modulated by arousal. MV emerges as the most reliable respiratory index of self-perceived arousal. Finally, end-tidal pCO2 is slightly lower during processing of negative as compared to positive picture contents, which is proposed to enhance sensory perception and reflect a negativity bias in attention.
Resumo:
Aortic access problems due to diseased or small peripheral vessels are a major issue in endovascular aneurysm repair (EVAR). In the emergency setting, like aortic rupture after blunt trauma, or in patients with a hostile abdomen, a more proximal access to the aorta is not a pleasant perspective. We developed in situ introducer sheath dilatation as a bail-out technique for patients with difficult aortic access under various circumstances including EVAR, intra-aortic balloon pump insertion and cannulation for perfusion. The method described allows to increase the access vessel diameter by 50% (from 6 to 9 mm) or the luminal circumference from 18 to 27 F. We have used this technique in five patients without complication, very much in contrast to the traditionally practiced 'forced device insertion'.
Resumo:
Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.