994 resultados para Surgical mask


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To describe and present the results of a new surgical technique for patients with floppy eyelid syndrome, based on the medial upper eyelid stretching encountered in this condition. Methods: A case series of 24 patients with floppy eyelid syndrome who where found to have symptomatic predominately medial upper eyelid laxity was analyzed. The history, clinical features, histopathology, and outcome were reviewed after patients underwent medial upper eyelid shortening with or without upper eyelid skin reduction as the first surgical procedure. Results: Of the 24 patients, 18 were men (75%) with a mean age at referral of 56 years, having ocular discomfort and conjunctival irritation/papillary conjunctivitis as the main complaints at presentation. Obesity was present in 96% of cases, with lower eyelid laxityl/ectropion (50%) and upper eyelid eyelash ptosis (29%) in conjunction with the upper eyelid laxity. The affected side was related to sleeping habits or recurrent mechanical eyelid trauma. Histologic studies showed a nonspecific inflammatory cell infiltrate and loss of elastin with loose dermal connective tissue. After surgery, complete relief of ocular symptoms and good functional and cosmetic results were present in all cases after 18 months of follow-up. Conclusions: This new surgical approach is based on the presence of predominately medial upper laxity in patients with floppy eyelid syndrome. The excision of this stretched area stabilized the upper eyelid in an anatomic fashion, providing a good and stable long-term result. The possible mechanisms involved in the medial upper eyelid stretching are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Intravenous (IV) fluid administration is an integral component of clinical care. Errors in administration can cause detrimental patient outcomes and increase healthcare costs, although little is known about medication administration errors associated with continuous IV infusions. Objectives: ( 1) To ascertain the prevalence of medication administration errors for continuous IV infusions and identify the variables that caused them. ( 2) To quantify the probability of errors by fitting a logistic regression model to the data. Methods: A prospective study was conducted on three surgical wards at a teaching hospital in Australia. All study participants received continuous infusions of IV fluids. Parenteral nutrition and non-electrolyte containing intermittent drug infusions ( such as antibiotics) were excluded. Medication administration errors and contributing variables were documented using a direct observational approach. Results: Six hundred and eighty seven observations were made, with 124 (18.0%) having at least one medication administration error. The most common error observed was wrong administration rate. The median deviation from the prescribed rate was 247 ml/h (interquartile range 275 to + 33.8 ml/ h). Errors were more likely to occur if an IV infusion control device was not used and as the duration of the infusion increased. Conclusions: Administration errors involving continuous IV infusions occur frequently. They could be reduced by more common use of IV infusion control devices and regular checking of administration rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fred Hollows and his work to reduce blindness in Indigenous communities is an obvious example of benevolence of doctors and nurses towards patients while the role of the staff of burns units around Australia in treating the victims of the Bali bombing is another. Some different stories about benevolence in medicine, concerning the benevolence of patients towards trainee clinical staff are suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To study the biocompatibility of surgical meshes for use in pelvic reconstructive surgery using an animal model. Eight different types of mesh: Atrium, Dexon, Gynemesh, IVS tape, Prolene, SPARC tape, TVT tape and Vypro II, were implanted into the abdominal walls of rats for 3 months' duration. Explanted meshes were assessed, using light microscopy, for parameters of rejection and incorporation. Type 1 (Atrium, Gynemesh, Prolene, SPARC and TVT) and type 3 (Vypro II, Dexon and IVS) meshes demonstrated different biocompatible properties. Inflammatory cellular response and fibrosis at the interface of mesh and host tissue was most marked with Vypro II and IVS. All type 1 meshes displayed similar cellular responses despite markedly different mesh architecture. The inflammatory response and fibrous reaction in the non-absorbable type 3 meshes tested (IVS and Vypro II) was more marked than the type 1 meshes. The increased inflammatory and fibrotic response may be because of the multifilamentous polypropylene components of these meshes. Material and filament composition of mesh is the main factor in determining cellular response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Laryngeal Mask Airway is a reusable device for maintaining the patency of a patient's airway during general anaesthesia. The device can be reused after it has been cleaned and sterilized. Protein contamination of medical instruments is a concern and has been found to occur despite standard sterilization techniques. The reason for the concern relates to the possibility of the transmission of prions and the risk of developing a neurodegenerative disorder such as Creutzveldt-Jacob disease. The purpose of this study was to quantify the amount of protein contamination that occurs, and to relate this to the number of times the Laryngeal Mask Airway has been used. Fifty previously used Classic Laryngeal Masks were collected after routine sterilization and packaging. The devices were immersed in protein detecting stain and then visual inspection performed to assess the degree and distribution of the staining. The researcher was blinded to the number of times the Laryngeal Mask Airway had been used. Linear regression analysis of the degrees of staining of the airway revealed that protein contamination occurs after the first use of the device and this increases with each subsequent use. This finding highlights the concern that the currently used cleaning and sterilization methods do not prevent the accumulation of proteinaceous material on Laryngeal Mask Airways. Consideration should be given to the search for more efficient cleaning and sterilization techniques or the use of disposable devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data were collected from surgical patients in the hospital and on 4 occasions postdischarge. The incidence of postdischarge surgical site infection was 8.46%. Strong evidence showed that these infections caused minor additional costs, which contradicts existing literature. We discuss why previous studies might have overstated costs.