987 resultados para Spreading center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The arene-ruthenium complex [Ru(eta(6)-C10H14)(dppf)Cl]PF6 (1) was used as a precursor for the syntheses of the [Ru(eta(6)-C10H14)(dppf)Br]PF6 (2), [Ru(eta(6)-C10H14)(dppf)I]PF6 (3). [Ru(eta(6)-C10H14)(dppf)SnF3]PF6 (4) and [Ru(eta(6)-C10H14)(dppf)Cl][SnCl3]center dot 0.45CH(2)Cl(2) (5) complexes by its reactions with KBr, Kl, SnF2 and SnCl2. respectively. All of the compounds were characterized by NMR, IR, Fe-57 and Sn-119-Mossbauer spectroscopy, and cyclic voltammetry. The single-crystal X-ray structure analysis of the [Ru(eta(6)-C10H14)(dppf)Cl] [SnCl3]center dot 0.45CH(2)Cl(2) complex revealed the expected piano-stool geometry. Cyclic voltammograms of the complexes showed only one quasi-reversible electrochemical process, involving the oxidation of Fe(II) and Ru(II) at the same potential, which was confirmed by exhaustive electrolysis experiments. Fe-57-Mossbauer parameters obtained for the complexes (1-5) were fitted with one doublet corresponding to a site of one iron(II). The Sn-119-Mossbauer parameters of the complex (4) indicate that tin is tetra covalent. (c) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Liver metastases are a common event in the clinical outcome of patients with colorectal cancer and account for 2/3 of deaths from this disease. There is considerable controversy among the data in the literature regarding the results of surgical treatment and prognostic factors of survival, and no analysis have been done in a large cohort of patients in Brazil. OBJECTIVES: To characterize the results of surgical treatment of patients with colorectal liver metastases, and to establish prognostic factors of survival in a Brazilian population. METHOD: This was a retrospective study of patients undergoing liver resection for colorectal metastases in a tertiary cancer hospital from 1998 to 2009. We analyzed epidemiologic variables and the clinical characteristics of primary tumors, metastatic disease and its treatment, surgical procedures and follow-up, and survival results. Survival analyzes were done by the Kaplan-Meier method and the log-rank test was applied to determine the influence of variables on overall and disease-free survival. All variables associated with survival with P<0.20 in univariate analysis, were included in multivariate analysis using a Cox proportional hazard regression model. RESULTS: During the period analyzed, 209 procedures were performed on 170 patients. Postope-rative mortality in 90 days was 2.9% and 5-year overall survival was 64.9%. Its independent prognostic factors were the presence of extrahepatic disease at diagnosis of liver metastases, bilateral nodules and the occurrence of major complications after liver surgery. The estimated 5-year disease-free survival was 39.1% and its prognostic factors included R1 resection, extrahepatic disease, bilateral nodules, lymph node involvement in the primary tumor and primary tumors located in the rectum. CONCLUSION: Liver resection for colorectal metastases is safe and effective and the analysis of prognostic factors of survival in a large cohort of Brazilian patients showed similar results to those pointed in international series. The occurrence of major postoperative complications appears to be able to compromise overall survival and further investigation in needed in this topic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although several studies have been conducted to evaluate the uniformity of water application under center pivot irrigation systems, there are few studies concerning the economic perspective of such coefficient. The aim of this study is to present a methodology to accomplish an economic analysis as support for the decision-making to retrofit emitters in center pivot irrigation systems, and to attribute an economic meaning to the uniformity coefficient of water application taking into account the response function productivity to the amount of water applied and the sale price of the crops. In the hypothetic calculation example considering the variation of revenue of potato crop under center pivot irrigation system, it was verified that the area with uniformity coefficient of water application of 90% brought an income increase of BR$ 1,992.00, considering an area about 1,0 ha. Thus, it can be concluded that the methodology presented has met the objectives proposed in the study and made it possible to attribute an economical meaning to the coefficient of water uniformity application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: In this study, we aimed to determine the complications of standard surgical treatments among patients over 75 years in a high-volume urologic center. METHODS: We analyzed 100 consecutive patients older than 75 years who had undergone transurethral prostatic resection of the prostate or open prostatectomy for treatment of benign prostatic hyperplasia from January 2008 to March 2010. We analyzed patient age, prostate volume, prostate-specific antigen level, international prostatic symptom score, quality of life score, urinary retention, co-morbidities, surgical technique and satisfaction with treatment. RESULTS: Median age was 79 years. Forty-eight patients had undergone transurethral prostatic resection of the prostate, and 52 had undergone open prostatectomy. The median International Prostatic Symptom Score was 20, the median prostate volume was 83 g, 51% were using an indwelling bladder catheter, and the median prostatespecific antigen level was 5.0 ng/ml. The most common comorbidities were hypertension, diabetes and coronary disease. After a median follow-up period of 17 months, most patients were satisfied. Complications were present in 20% of cases. The most common urological complication was urethral stenosis, followed by bladder neck sclerosis, urinary fistula, late macroscopic hematuria and persistent urinary incontinence. The most common clinical complication was myocardial infarction, followed by acute renal failure requiring dialysis. Incidental carcinoma of the prostate was present in 6% of cases. One case had urothelial bladder cancer. CONCLUSIONS: Standard surgical treatments for benign prostatic hyperplasia are safe and satisfactory among the elderly. Complications are infrequent, and urethral stenosis is the most common. No clinical variable is associated with the occurrence of complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most cases of sporadic primary hyperparathyroidism present disturbances in a single parathyroid gland and the surgery of choice is adenomectomy. Conversely, hyperparathyroidism associated with multiple endocrine neoplasia type 1 (hyperparathyroidism/multiple endocrine neoplasia type 1) is an asynchronic, asymmetrical multiglandular disease and it is surgically approached by either subtotal parathyroidectomy or total parathyroidectomy followed by parathyroid auto-implant to the forearm. In skilful hands, the efficacy of both approaches is similar and both should be complemented by prophylactic thymectomy. In a single academic center, 83 cases of hyperparathyroidism/ multiple endocrine neoplasia type 1 were operated on from 1987 to 2010 and our first surgical choice was total parathyroidectomy followed by parathyroid auto-implant to the non-dominant forearm and, since 1997, associated transcervical thymectomy to prevent thymic carcinoid. Overall, 40% of patients were given calcium replacement (mean intake 1.6 g/day) during the first months after surgery, and this fell to 28% in patients with longer follow-up. These findings indicate that several months may be needed in order to achieve a proper secretion by the parathyroid auto-implant. Hyperparathyroidism recurrence was observed in up to 15% of cases several years after the initial surgery. Thus, long-term follow-up is recommended for such cases. We conclude that, despite a tendency to subtotal parathyroidectomy worldwide, total parathyroidectomy followed by parathyroid auto-implant is a valid surgical option to treat hyperparathyroidism/multiple endocrine neoplasia type 1. Larger comparative systematic studies are needed to define the best surgical approach to hyperparathyroidism/multiple endocrine neoplasia type 1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulmonary surfactant is a very important product in the medical treatment of the syndrome of insufficiency respiratory in neonates. The synthesis of this surfactant in labs need to optimize the rate of spreading in the alveolar interstitial liquid obtaining a monolayer of the phospholipids membrane base capable to maintains several of the dynamical properties of the respiratory system during breathing. The recover of theses mechanical properties has to be archived using the minimal quantities of product and with the optimal proteins composition (SP-B in special). In this paper we show our results of obtaining and process speckle pattern images of the spreading of phospholipids membrane composed the matrix of this product (DPPC) when physiologic interstitial liquid are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis we focussed on the characterization of the reaction center (RC) protein purified from the photosynthetic bacterium Rhodobacter sphaeroides. In particular, we discussed the effects of native and artificial environment on the light-induced electron transfer processes. The native environment consist of the inner antenna LH1 complex that copurifies with the RC forming the so called core complex, and the lipid phase tightly associated with it. In parallel, we analyzed the role of saccharidic glassy matrices on the interplay between electron transfer processes and internal protein dynamics. As a different artificial matrix, we incorporated the RC protein in a layer-by-layer structure with a twofold aim: to check the behaviour of the protein in such an unusual environment and to test the response of the system to herbicides. By examining the RC in its native environment, we found that the light-induced charge separated state P+QB - is markedly stabilized (by about 40 meV) in the core complex as compared to the RC-only system over a physiological pH range. We also verified that, as compared to the average composition of the membrane, the core complex copurifies with a tightly bound lipid complement of about 90 phospholipid molecules per RC, which is strongly enriched in cardiolipin. In parallel, a large ubiquinone pool was found in association with the core complex, giving rise to a quinone concentration about ten times larger than the average one in the membrane. Moreover, this quinone pool is fully functional, i.e. it is promptly available at the QB site during multiple turnover excitation of the RC. The latter two observations suggest important heterogeneities and anisotropies in the native membranes which can in principle account for the stabilization of the charge separated state in the core complex. The thermodynamic and kinetic parameters obtained in the RC-LH1 complex are very close to those measured in intact membranes, indicating that the electron transfer properties of the RC in vivo are essentially determined by its local environment. The studies performed by incorporating the RC into saccharidic matrices evidenced the relevance of solvent-protein interactions and dynamical coupling in determining the kinetics of electron transfer processes. The usual approach when studying the interplay between internal motions and protein function consists in freezing the degrees of freedom of the protein at cryogenic temperature. We proved that the “trehalose approach” offers distinct advantages with respect to this traditional methodology. We showed, in fact, that the RC conformational dynamics, coupled to specific electron transfer processes, can be modulated by varying the hydration level of the trehalose matrix at room temperature, thus allowing to disentangle solvent from temperature effects. The comparison between different saccharidic matrices has revealed that the structural and dynamical protein-matrix coupling depends strongly upon the sugar. The analyses performed in RCs embedded in polyelectrolyte multilayers (PEM) structures have shown that the electron transfer from QA - to QB, a conformationally gated process extremely sensitive to the RC environment, can be strongly modulated by the hydration level of the matrix, confirming analogous results obtained for this electron transfer reaction in sugar matrices. We found that PEM-RCs are a very stable system, particularly suitable to study the thermodynamics and kinetics of herbicide binding to the QB site. These features make PEM-RC structures quite promising in the development of herbicide biosensors. The studies discussed in the present thesis have shown that, although the effects on electron transfer induced by the native and artificial environments tested are markedly different, they can be described on the basis of a common kinetic model which takes into account the static conformational heterogeneity of the RC and the interconversion between conformational substates. Interestingly, the same distribution of rate constants (i.e. a Gamma distribution function) can describe charge recombination processes in solutions of purified RC, in RC-LH1 complexes, in wet and dry RC-PEM structures and in glassy saccharidic matrices over a wide range of hydration levels. In conclusion, the results obtained for RCs in different physico-chemical environments emphasize the relevance of the structure/dynamics solvent/protein coupling in determining the energetics and the kinetics of electron transfer processes in a membrane protein complex.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the first underground nuclear explosion, carried out in 1958, the analysis of seismic signals generated by these sources has allowed seismologists to refine the travel times of seismic waves through the Earth and to verify the accuracy of the location algorithms (the ground truth for these sources was often known). Long international negotiates have been devoted to limit the proliferation and testing of nuclear weapons. In particular the Treaty for the comprehensive nuclear test ban (CTBT), was opened to signatures in 1996, though, even if it has been signed by 178 States, has not yet entered into force, The Treaty underlines the fundamental role of the seismological observations to verify its compliance, by detecting and locating seismic events, and identifying the nature of their sources. A precise definition of the hypocentral parameters represents the first step to discriminate whether a given seismic event is natural or not. In case that a specific event is retained suspicious by the majority of the State Parties, the Treaty contains provisions for conducting an on-site inspection (OSI) in the area surrounding the epicenter of the event, located through the International Monitoring System (IMS) of the CTBT Organization. An OSI is supposed to include the use of passive seismic techniques in the area of the suspected clandestine underground nuclear test. In fact, high quality seismological systems are thought to be capable to detect and locate very weak aftershocks triggered by underground nuclear explosions in the first days or weeks following the test. This PhD thesis deals with the development of two different seismic location techniques: the first one, known as the double difference joint hypocenter determination (DDJHD) technique, is aimed at locating closely spaced events at a global scale. The locations obtained by this method are characterized by a high relative accuracy, although the absolute location of the whole cluster remains uncertain. We eliminate this problem introducing a priori information: the known location of a selected event. The second technique concerns the reliable estimates of back azimuth and apparent velocity of seismic waves from local events of very low magnitude recorded by a trypartite array at a very local scale. For the two above-mentioned techniques, we have used the crosscorrelation technique among digital waveforms in order to minimize the errors linked with incorrect phase picking. The cross-correlation method relies on the similarity between waveforms of a pair of events at the same station, at the global scale, and on the similarity between waveforms of the same event at two different sensors of the try-partite array, at the local scale. After preliminary tests on the reliability of our location techniques based on simulations, we have applied both methodologies to real seismic events. The DDJHD technique has been applied to a seismic sequence occurred in the Turkey-Iran border region, using the data recorded by the IMS. At the beginning, the algorithm was applied to the differences among the original arrival times of the P phases, so the cross-correlation was not used. We have obtained that the relevant geometrical spreading, noticeable in the standard locations (namely the locations produced by the analysts of the International Data Center (IDC) of the CTBT Organization, assumed as our reference), has been considerably reduced by the application of our technique. This is what we expected, since the methodology has been applied to a sequence of events for which we can suppose a real closeness among the hypocenters, belonging to the same seismic structure. Our results point out the main advantage of this methodology: the systematic errors affecting the arrival times have been removed or at least reduced. The introduction of the cross-correlation has not brought evident improvements to our results: the two sets of locations (without and with the application of the cross-correlation technique) are very similar to each other. This can be commented saying that the use of the crosscorrelation has not substantially improved the precision of the manual pickings. Probably the pickings reported by the IDC are good enough to make the random picking error less important than the systematic error on travel times. As a further justification for the scarce quality of the results given by the cross-correlation, it should be remarked that the events included in our data set don’t have generally a good signal to noise ratio (SNR): the selected sequence is composed of weak events ( magnitude 4 or smaller) and the signals are strongly attenuated because of the large distance between the stations and the hypocentral area. In the local scale, in addition to the cross-correlation, we have performed a signal interpolation in order to improve the time resolution. The algorithm so developed has been applied to the data collected during an experiment carried out in Israel between 1998 and 1999. The results pointed out the following relevant conclusions: a) it is necessary to correlate waveform segments corresponding to the same seismic phases; b) it is not essential to select the exact first arrivals; and c) relevant information can be also obtained from the maximum amplitude wavelet of the waveforms (particularly in bad SNR conditions). Another remarkable point of our procedure is that its application doesn’t demand a long time to process the data, and therefore the user can immediately check the results. During a field survey, such feature will make possible a quasi real-time check allowing the immediate optimization of the array geometry, if so suggested by the results at an early stage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liver transplantation is the only definitive treatment for transthyretin amyloidosis, with an excellent 5-year survival in endemic countries where the Met30 mutation is predominant. We report our experience of liver transplantation for transthyretin amyloidosis. We reviewed the clinical records of 17 transplanted patients (11 males, 6 females; age at liver transplant: 45.7±11.7 years). We had a wide spectrum of non-Met30 mutations (52.9%), with a predominance of Gln89 (23.5%). Five-year survival after transplantation was 43.8%; at multivariate analysis, both non-Met30 mutations (HR 17.3, 95% CI 1.03-291.7) and modified BMI (HR 0.50, 95% CI 0.29-0.87) showed significant and independent prognostic roles (P=0.048 and P=0.015, respectively). Five out of the 9 non-Met30 carriers received combined heart transplantation because of severe cardiomyopathy; they showed a trend towards a better prognosis vs. the 4 patients who did not receive combined heart transplantation (although not statistically significant; P=0.095). At follow-up, no significant improvement of transthyretin amyloidosis manifestations was observed. The results of liver transplantation for transthyretin amyloidosis in our population are poorer than those reported in the literature probably because of the high prevalence of non-Met30 mutations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Con la crescente diffusione del web e dei servizi informatici offerti via internet, è aumentato in questi anni l’utilizzo dei data center e conseguentemente, il consumo di energia elettrica degli stessi. Il problema ambientale che comporta l’alto fabbisogno energetico, porta gli operatori di data center ad utilizzare tecniche a basso consumo e sistemi efficienti. Organizzazioni ambientali hanno rilevato che nel 2011 i consumi derivanti dai data center raggiungeranno i 100 milioni di kWh, con un costo complessivo di 7,4 milioni di dollari nei soli Stati Uniti, con una proiezione simile anche a livello globale. La seguente tesi intende valutare le tecniche in uso per diminuire il consumo energetico nei data center, e quali tecniche vengono maggiormente utilizzate per questo scopo. Innanzitutto si comincerà da una panoramica sui data center, per capire il loro funzionamento e per mostrare quali sono i componenti fondamentali che lo costituiscono; successivamente si mostrerà quali sono le parti che incidono maggiormente nei consumi, e come si devono effettuare le misurazioni per avere dei valori affidabili attraverso la rilevazione del PUE, unità di misura che valuta l’efficienza di un data center. Dal terzo capitolo si elencheranno le varie tecniche esistenti e in uso per risolvere il problema dell’efficienza energetica, mostrando alla fine una breve analisi sui metodi che hanno utilizzato le maggiori imprese del settore per risolvere il problema dei consumi nei loro data center. Lo scopo di questo elaborato è quello di capire quali sono le tecniche e le strategie per poter ridurre i consumi e aumentare l’efficienza energetica dei data center.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Transjugular intrahepatic porto-systemic shunt (TIPS) is an accepted indication for treating refractory ascites. Different models have been proposed for the prediction of survival after TIPS; aim of present study was to evaluate the factors associated with mortality after TIPS for refractory ascites. Methods: Seventy-three consecutive patients undergoing a TIPS for refractory ascites in our centre between 2003 and 2008, were prospectively recorded in a database ad were the subject of the study. Mean follow-up was 17±2 months. Forty patients were awaiting liver transplantation (LT) and 12 (16.4%) underwent LT during follow-up. Results: Mean MELD at the moment of TIPS was 15.7±5.3. Overall mortality was 23.3% (n=17) with a mean survival after TIPS of 17±14 months. MELD score (B=0.161, p=0.042), AST (B= 0.020, p=0.090) and pre-TIPS HVPG (B=0.016, p=0.093) were independent predictors of overall mortality. On multivariate analysis MELD (B=0.419, p=0.018) and pre-TIPS HVPG (B=0.223, p=0.060) independently predicted 1 year survival. Patients were stratified into categories of death risk, using ROC curves for the variables MELD and HVPG. Patients with MELD<10 had a low probability of death after TIPS (n=6, 16% mortality); patients with HVPG <16 mmHg (n=6) had no mortality. Maximum risk of death was found in patients with MELD score 19 (n=16, 31% mortality) and in those with HVPG 25 mmHg (n=27, 26% mortality). Conclusions: TIPS increases overall survival in patients with refractory ascites. Liver function (assessed by MELD), necroinflammation (AST) and portal hypertension (HVPG) are independent predictors of survival; patients with MELD>19 and HVPG>25 mmHg are at highest risk of death after TIPS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Questa tesi tratta lo sviluppo di un software in grado di simulare le dinamiche tra fluidi e oggetti considerando la propagazione del calore in vista di possibili applicazioni rivolte ad ambienti in cui lo stato termico del sistema e' critico (data center).