945 resultados para Silicone elastomers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Technological developments in biomedical microsystems are opening up new opportunities to improve healthcare procedures. Swallowable diagnostic capsules are an example of this. In this paper, a diagnostic capsule technology is described based on direct-access sensing of the Gastro Intestinal (GI) fluids throughout the GI tract. The objective of this paper is two-fold: i) develop a packaging method for a direct access sensor, ii) develop an encapsulation method to protect the system electronics. The integrity of the interconnection after sensor packaging and encapsulation is correlated to its reliability and thus of importance. The zero level packaging of the sensor was achieved by using a so called Flip Chip Over Hole (FCOH) method. This allowed the fluidic sensing media to interface with the sensor, while the rest of the chip including the electrical connections can be insulated effectively. Initial tests using Anisotropic Conductive Adhesive (ACA) interconnect for the FCOH demonstrated good electrical connections and functionality of the sensor chip. Also a preliminary encapsulation trial of the flip chipped sensor on a flexible test substrate has been carried out and showed that silicone encapsulation of the system is a viable option.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Technological developments in biomedical microsystems are opening up new opportunities to improve healthcare procedures. Swallowable diagnostic sensing capsules are an example of these. In none of the diagnostic sensing capsules, is the sensor’s first level packaging achieved via Flip Chip Over Hole (FCOH) method using Anisotropic Conductive Adhesive (ACA). In a capsule application with direct access sensor (DAS), ACA not only provides the electrical interconnection but simultaneously seals the interconnect area and the underlying electronics. The development showed that the ACA FCOH was a viable option for the DAS interconnection. Adequate adhesive formed a strong joint that withstood a shear stress of 120N/mm2 and a compressive stress of 6N required to secure the final sensor assembly in place before encapsulation. Electrical characterization of the ACA joint in a fluid environment showed that the ACA was saturated with moisture and that the ions in the solution actively contributed to the leakage current, characterized by the varying rate of change of conductance. Long term hygrothermal aging of the ACA joint showed that a thermal strain of 0.004 and a hygroscopic strain of 0.0052 were present and resulted in a fatigue like process. In-vitro tests showed that high temperature and acidity had a deleterious effect of the ACA and its joint. It also showed that the ACA contact joints positioned at around or over 1mm would survive the gastrointestinal (GI) fluids and would be able to provide a reliable contact during the entire 72hr of the GI transit time. A final capsule demonstrator was achieved by successfully integrating the DAS, the battery and the final foldable circuitry into a glycerine capsule. Final capsule soak tests suggested that the silicone encapsulated system could survive the 72hr gut transition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The coupling of mechanical stress fields in polymers to covalent chemistry (polymer mechanochemistry) has provided access to previously unattainable chemical reactions and polymer transformations. In the bulk, mechanochemical activation has been used as the basis for new classes of stress-responsive polymers that demonstrate stress/strain sensing, shear-induced intermolecular reactivity for molecular level remodeling and self-strengthening, and the release of acids and other small molecules that are potentially capable of triggering further chemical response. The potential utility of polymer mechanochemistry in functional materials is limited, however, by the fact that to date, all reported covalent activation in the bulk occurs in concert with plastic yield and deformation, so that the structure of the activated object is vastly different from its nascent form. Mechanochemically activated materials have thus been limited to “single use” demonstrations, rather than as multi-functional materials for structural and/or device applications. Here, we report that filled polydimethylsiloxane (PDMS) elastomers provide a robust elastic substrate into which mechanophores can be embedded and activated under conditions from which the sample regains its original shape and properties. Fabrication is straightforward and easily accessible, providing access for the first time to objects and devices that either release or reversibly activate chemical functionality over hundreds of loading cycles.

While the mechanically accelerated ring-opening reaction of spiropyran to merocyanine and associated color change provides a useful method by which to image the molecular scale stress/strain distribution within a polymer, the magnitude of the forces necessary for activation had yet to be quantified. Here, we report single molecule force spectroscopy studies of two spiropyran isomers. Ring opening on the timescale of tens of milliseconds is found to require forces of ~240 pN, well below that of previously characterized covalent mechanophores. The lower threshold force is a combination of a low force-free activation energy and the fact that the change in rate with force (activation length) of each isomer is greater than that inferred in other systems. Importantly, quantifying the magnitude of forces required to activate individual spiropyran-based force-probes enables the probe behave as a “scout” of molecular forces in materials; the observed behavior of which can be extrapolated to predict the reactivity of potential mechanophores within a given material and deformation.

We subsequently translated the design platform to existing dynamic soft technologies to fabricate the first mechanochemically responsive devices; first, by remotely inducing dielectric patterning of an elastic substrate to produce assorted fluorescent patterns in concert with topological changes; and second, by adopting a soft robotic platform to produce a color change from the strains inherent to pneumatically actuated robotic motion. Shown herein, covalent polymer mechanochemistry provides a viable mechanism to convert the same mechanical potential energy used for actuation into value-added, constructive covalent chemical responses. The color change associated with actuation suggests opportunities for not only new color changing or camouflaging strategies, but also the possibility for simultaneous activation of latent chemistry (e.g., release of small molecules, change in mechanical properties, activation of catalysts, etc.) in soft robots. In addition, mechanochromic stress mapping in a functional actuating device might provide a useful design and optimization tool, revealing spatial and temporal force evolution within the actuator in a way that might also be coupled to feedback loops that allow autonomous, self-regulation of activity.

In the future, both the specific material and the general approach should be useful in enriching the responsive functionality of soft elastomeric materials and devices. We anticipate the development of new mechanophores that, like the materials, are reversibly and repeatedly activated, expanding the capabilities of soft, active devices and further permitting dynamic control over chemical reactivity that is otherwise inaccessible, each in response to a single remote signal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pouvoir déterminer la provenance des sons est fondamental pour bien interagir avec notre environnement. La localisation auditive est une faculté importante et complexe du système auditif humain. Le cerveau doit décoder le signal acoustique pour en extraire les indices qui lui permettent de localiser une source sonore. Ces indices de localisation auditive dépendent en partie de propriétés morphologiques et environnementales qui ne peuvent être anticipées par l'encodage génétique. Le traitement de ces indices doit donc être ajusté par l'expérience durant la période de développement. À l’âge adulte, la plasticité en localisation auditive existe encore. Cette plasticité a été étudiée au niveau comportemental, mais on ne connaît que très peu ses corrélats et mécanismes neuronaux. La présente recherche avait pour objectif d'examiner cette plasticité, ainsi que les mécanismes d'encodage des indices de localisation auditive, tant sur le plan comportemental, qu'à travers les corrélats neuronaux du comportement observé. Dans les deux premières études, nous avons imposé un décalage perceptif de l’espace auditif horizontal à l’aide de bouchons d’oreille numériques. Nous avons montré que de jeunes adultes peuvent rapidement s’adapter à un décalage perceptif important. Au moyen de l’IRM fonctionnelle haute résolution, nous avons observé des changements de l’activité corticale auditive accompagnant cette adaptation, en termes de latéralisation hémisphérique. Nous avons également pu confirmer l’hypothèse de codage par hémichamp comme représentation de l'espace auditif horizontal. Dans une troisième étude, nous avons modifié l’indice auditif le plus important pour la perception de l’espace vertical à l’aide de moulages en silicone. Nous avons montré que l’adaptation à cette modification n’était suivie d’aucun effet consécutif au retrait des moulages, même lors de la toute première présentation d’un stimulus sonore. Ce résultat concorde avec l’hypothèse d’un mécanisme dit de many-to-one mapping, à travers lequel plusieurs profils spectraux peuvent être associés à une même position spatiale. Dans une quatrième étude, au moyen de l’IRM fonctionnelle et en tirant profit de l’adaptation aux moulages de silicone, nous avons révélé l’encodage de l’élévation sonore dans le cortex auditif humain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Travail créatif / Creative Work

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A matrix-type silicone elastomer vaginal ring providing 28-day continuous release of dapivirine (DPV) - a lead candidate human immunodeficiency virus type 1 (HIV-1) microbicide compound - has recently demonstrated moderate levels of protection in two Phase III clinical studies. Here, next-generation matrix and reservoir-type silicone elastomer vaginal rings are reported for the first time offering simultaneous and continuous in vitro release of DPV and the contraceptive progestin levonorgestrel (LNG) over a period of between 60 and 180days. For matrix-type vaginal rings comprising initial drug loadings of 100, 150 or 200mg DPV and 0, 16 or 32mg LNG, Day 1 daily DPV release values were between 4132 and 6113μg while Day 60 values ranged from 284 to 454μg. Daily LNG release ranged from 129 to 684μg on Day 1 and 2-91μg on Day 60. Core-type rings comprising one or two drug-loaded cores provided extended duration of in vitro release out to 180days, and maintained daily drug release rates within much narrower windows (either 75-131μg/day or 37-66μg/day for DPV, and either 96-150μg/day or 37-57μg/day for LNG, depending on core ring configuration and ignoring initial lag release effect for LNG) compared with matrix-type rings. The data support the continued development of these devices as multi-purpose prevention technologies (MPTs) for HIV prevention and long-acting contraception.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Human race of our century is in gluttonous search for novel engineering products which led to a skyrocketed progress in research and fabrication of filled polymers. Recently, a big window has been opened up for speciality polymers especially elastomers with promising properties. Among the many reasons why rubbers are widely used in the process industries, three are considered as important. Firstly, rubbers operate in a variety of environments and possess usable ranges of deformity and durability and can be exploited through suitable and more or less conventional equipment design principles. Secondly, rubber is an eminently suitable construction material for protection against corrosion in the chemical plant and equipment against various corrosive chemicals as, acids and alkalies and if property tailored, can shield ionising radiations as X-rays and gamma rays in medical industry, with minimum maintenance lower down time, negligible corrosion and a preferred choice for aggressive corroding and ionising environment. Thirdly, rubber can readily and hastily, and at a relatively lower cost, be converted into serviceable products, having intricate shapes and dimensions. In a century’s gap, large employment of flexible polymer materials in the different segments of industry has stimulated the development of new materials with special properties, which paved its way to the synthesis of various nanoscale materials. At nano scale, one makes an entry into a world where multidisciplinary sciences meet and utilises the previously unapproached infinitesimal length scale, having dimension which measure upto one billionth of a meter, to create novel properties. The nano fillers augment the elastomers properties in an astonishing fashion due to their multifunctional nature and unprecedented properties have been exhibited by these polymer-nanocomposites just to beat the shortcomings of traditional micro composites. The current research aims to investigate the possibility of using synthesised nano barium sulphate for fabricating elastomer-based nanocomposites and thereby imparting several properties to the rubber. In this thesis, nano materials, their synthesis, structure, properties and applications are studied. The properties of barium sulphate like chemical resistance and radiopacity have been utilized in the present study and is imparted to the elastomers by preparing composites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Avaliar o efeito da nicotina na cicatrização da camada musculoaponeurótica da parede abdominal. Métodos: Estudo experimental em que foram usados 16 ratos da raça Wistar pesando em média 210±8g, separados aleatoriamente em 2 grupos de 8. Nos animais do grupo A foi implantado disco de nicotina (Nicotinel Ò) na dose de 5mg/Kg de peso/dia no subcutâneo da região dorsal, trocado a cada dois dias, a partir do 5º dia antes da operação em que foi feita laparotomia mediana de 5 cm, até o 10o dia de observação. No grupo B (controle) foram usados discos de celulose com o mesmo diâmetro. Tubo de silicone multiperfurado foi implantado no subcutâneo a 1cm da lesão da parede abdominal. A camada musculoaponeurótica e a pele foram suturadas com fio de nylon 5-0. No 10º dia pós-operatório foi colhido 1ml de líquido seroso do tubo de silicone por punção percutânea para dosagem de pO2 e os animais receberam dose letal de anestésico. Foi ressecado um segmento da camada musculoaponeurótica com 2cm de largura para tensiometria, em seguida processado e corado em HE e tricrômico de Masson para análise quantitativa dos dados histopatológicos em sistema digitalizado. A análise estatística foi feita pelo ANOVA e teste Newman-Keuls, com significância 0,05. Resultados: No grupo A a pO2 do líquido tecidual atingiu o valor 17,75±3,4 mmHg e no grupo B (controle) a pO2 = 40,75±6,4 mmHg (p<0,01). A resistência à tensão apresentou o valor de 728,5±161,75gf no grupo A e 1241,6±232gf no grupo de controle (p<0,01), coincidindo com os achados da pO2. A densidade média dos elementos histopatológicos estudados foi de 105±17,1 nos animais do grupo A e 146,2±8,8 no grupo B (p<0,01). Conclusão: após avaliação da pO2 tecidual, tensiometria e histopatologia, concluiu-se que a nicotina por via subcutânea exerce efeito deletério sobre a cicatrização de lesões da parede abdominal de ratos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hallux rígidus (HR) affects the first metatarsophalangeal joint (MTPJ) between 35% and 60% of the population over 65 years and there are multiple ways of treatment. Depending on the radiological stage where you find the deformity determines the procedure to be performed; in the early stages cheilectomy techniques and corrective osteotomy is performed while the more advanced ratings, the surgeon chooses destructive techniques considered as arthrodesis and arthroplasty. This final of degree project aims to focus on 1 MTPJ destructive techniques to clarify which of the procedures generates better results by a number of parameters; outcomes of the American Orthopaedic Foot scale and Ankle Society Hallux metatarsophalangeal Interphalangeal-scale (AOFAS), range of motion (ROM) of the 1ºAMTF, radiological classification. As for the implant arthroplasty technique, this article offers information on material and design that generates better relating to patient characteristics such as age, inflammatory joint diseases, viability and durability of the implant results. The conclusion from this review is that the values obtained in the arthrodesis according AOFAS decrease due to loss of mobility, but both techniques have similar values of effectiveness and concludes with the decision that the technique used is determined taking into account various factors and patient characteristics. Keywords: Hallux rígidus; (Hallux Rígidus) and surgery treatment; Hallux Rígidus arthrodesis; Hallux Rígidus arthroplasty; Hallux Rígidus (arthroplasty and arthrodesis).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The engineering of liquid behavior on surfaces is important for infrastructure, transportation, manufacturing, and sensing. Surfaces can be rendered superhydrophobic by microstructuring, and superhydrophobic devices could lead to practical corrosion inhibition, self-cleaning, fluid flow control, and surface drag reduction. To more fully understand how liquid interacts with microstructured surfaces, this dissertation introduces a direct method for determining droplet solid-liquid-vapor interfacial geometry on microstructured surfaces. The technique performs metrology on molten metal droplets deposited onto microstructured surfaces and then frozen. Unlike other techniques, this visualization technique can be used on large areas of curved and opaque microstructured surfaces to determine contact line. This dissertation also presents measurements and models for how curvature and flexing of microstructured polymers affects hydrophobicity. Increasing curvature of microstructured surfaces leads to decreased slide angle for liquid droplets suspended on the surface asperities. For a surface with regularly spaced asperities, as curvature becomes more positive, droplets suspended on the tops of asperities are suspended on fewer asperities. Curvature affects superhydrophobicity because microscopic curvature changes solid-liquid interaction, pitch is altered, and curvature changes the shape of the three phase contact line. This dissertation presents a model of droplet interactions with curved microstructured surfaces that can be used to design microstructure geometries that maintain the suspension of a droplet when curved surfaces are covered with microstructured polymers. Controlling droplet dynamics could improve microfluidic devices and the shedding of liquids from expensive equipment, preventing corrosion and detrimental performance. This dissertation demonstrates redirection of dynamic droplet spray with anisotropic microstructures. Superhydrophobic microstructured surfaces can be economically fabricated using metal embossing masters, so this dissertation describes casting-based microfabrication of metal microstructures and nanostructures. Low melting temperature metal was cast into flexible silicone molds which were themselves cast from microfabricated silicon templates. The flexibility of the silicone mold permits casting of curved surfaces, which this dissertation demonstrates by fabricating a cylindrical metal roller with microstructures. The metal microstructures can be in turn used as a reusable molding tool. This dissertation also describes an industrial investment casting process to produce aluminum molds having integrated microstructures. Unlike conventional micromolding tools, the aluminum mold was large and had complex curved surfaces. The aluminum was cast into curved microstructured ceramic molds which were themselves cast from curved microstructured rubber. Many structures were successfully cast into the aluminum with excellent replication fidelity, including circular, square, and triangular holes. This dissertation demonstrates molding of large, curved surfaces having surface microstructures using the aluminum mold. This work contributes a more full understanding of the phenomenon of superhydrophobicity and techniques for the economic fabrication of superhydrophobic microstructures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The selective solar absorber surface is a fundamental part of a solar thermal collector, as it is responsible for the solar radiation absorption and for reduction of radiation heat losses. The surface’s optical properties, the solar absorption (á) and the emittance (å), have great impact on the solar thermal collector efficiency. In this work, two coatings types were studied: coatings obtained by physical vapor deposition (PVDs) and coatings obtained by projection with different paints (PCs) on aluminum substrates. The most common industrial high performing solar selective absorbers are nowadays produced by vacuum deposition methods, showing some disadvantages, such as lower durability, lower resistance to corrosion, adhesion and scratch, higher cost and complex production techniques. Currently, spectrally selective paints are a potential alternative for absorbing surfaces in low temperature applications, with attractive features such as ease of processing, durability and commercial availability with low cost. Solar absorber surfaces were submitted to accelerated ageing tests, specified in ISO 22975-3. This standard is applicable to the evaluation of the long term behavior and service life of selective solar absorbers for solar collectors working under typical domestic hot water system conditions. The studied coatings have, in the case of PVDs solar absorptions between 0.93 and 0.96 and emittance between 0.07 and 0.10, and in the case of PCs, solar absorptions between 0.91 and 0.93 and emittance between 0.40 and 0.60. In addition to evaluating long term behavior based on artificial ageing tests, it is also important to know the degradation mechanism of different coatings that are currently in the market. Electrochemical impedance spectroscopy (EIS) allows for the assessment of mechanistic information concerning the degradation processes, providing quantitative data as output, which can easily relate to the kinetic parameters of the system. EIS measures were carried out on Gamry FAS2 Femostat coupled with a PCL4 Controller. Two electrolytes were used, 0.5 M NaCl and 0.5 M Na2SO4, and the surfaces were tested at different immersion times up to 4 weeks. The following types of specimens have been tested: Aluminium with/without surface treatment, 3 selective paint coatings (one with a poly(urethane) binder and two with silicone binders) and 2 PVD coatings. Based on the behaviour of the specimens throughout the 4 weeks of immersion, it is possible to conclude that the coating showing the best protective properties corresponds to the selective paint coating with a polyurethane resin followed by the other paint coatings, whereas both the PVD coatings do not confer any protection to the substrate, having a deleterious effect as compared to the untreated aluminium reference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nonlinear thermo-mechanical properties of advanced polymers are crucial to accurate prediction of the process induced warpage and residual stress of electronics packages. The Fiber Bragg grating (FBG) sensor based method is advanced and implemented to determine temperature and time dependent nonlinear properties. The FBG sensor is embedded in the center of the cylindrical specimen, which deforms together with the specimen. The strains of the specimen at different loading conditions are monitored by the FBG sensor. Two main sources of the warpage are considered: curing induced warpage and coefficient of thermal expansion (CTE) mismatch induced warpage. The effective chemical shrinkage and the equilibrium modulus are needed for the curing induced warpage prediction. Considering various polymeric materials used in microelectronic packages, unique curing setups and procedures are developed for elastomers (extremely low modulus, medium viscosity, room temperature curing), underfill materials (medium modulus, low viscosity, high temperature curing), and epoxy molding compound (EMC: high modulus, high viscosity, high temperature pressure curing), most notably, (1) zero-constraint mold for elastomers; (2) a two-stage curing procedure for underfill materials and (3) an air-cylinder based novel setup for EMC. For the CTE mismatch induced warpage, the temperature dependent CTE and the comprehensive viscoelastic properties are measured. The cured cylindrical specimen with a FBG sensor embedded in the center is further used for viscoelastic property measurements. A uni-axial compressive loading is applied to the specimen to measure the time dependent Young’s modulus. The test is repeated from room temperature to the reflow temperature to capture the time-temperature dependent Young’s modulus. A separate high pressure system is developed for the bulk modulus measurement. The time temperature dependent bulk modulus is measured at the same temperatures as the Young’s modulus. The master curve of the Young’s modulus and bulk modulus of the EMC is created and a single set of the shift factors is determined from the time temperature superposition. The supplementary experiments are conducted to verify the validity of the assumptions associated with the linear viscoelasticity. The measured time-temperature dependent properties are further verified by a shadow moiré and Twyman/Green test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Avaliar o efeito da nicotina na cicatrização da camada musculoaponeurótica da parede abdominal. Métodos: Estudo experimental em que foram usados 16 ratos da raça Wistar pesando em média 210±8g, separados aleatoriamente em 2 grupos de 8. Nos animais do grupo A foi implantado disco de nicotina (Nicotinel Ò) na dose de 5mg/Kg de peso/dia no subcutâneo da região dorsal, trocado a cada dois dias, a partir do 5º dia antes da operação em que foi feita laparotomia mediana de 5 cm, até o 10o dia de observação. No grupo B (controle) foram usados discos de celulose com o mesmo diâmetro. Tubo de silicone multiperfurado foi implantado no subcutâneo a 1cm da lesão da parede abdominal. A camada musculoaponeurótica e a pele foram suturadas com fio de nylon 5-0. No 10º dia pós-operatório foi colhido 1ml de líquido seroso do tubo de silicone por punção percutânea para dosagem de pO2 e os animais receberam dose letal de anestésico. Foi ressecado um segmento da camada musculoaponeurótica com 2cm de largura para tensiometria, em seguida processado e corado em HE e tricrômico de Masson para análise quantitativa dos dados histopatológicos em sistema digitalizado. A análise estatística foi feita pelo ANOVA e teste Newman-Keuls, com significância 0,05. Resultados: No grupo A a pO2 do líquido tecidual atingiu o valor 17,75±3,4 mmHg e no grupo B (controle) a pO2 = 40,75±6,4 mmHg (p<0,01). A resistência à tensão apresentou o valor de 728,5±161,75gf no grupo A e 1241,6±232gf no grupo de controle (p<0,01), coincidindo com os achados da pO2. A densidade média dos elementos histopatológicos estudados foi de 105±17,1 nos animais do grupo A e 146,2±8,8 no grupo B (p<0,01). Conclusão: após avaliação da pO2 tecidual, tensiometria e histopatologia, concluiu-se que a nicotina por via subcutânea exerce efeito deletério sobre a cicatrização de lesões da parede abdominal de ratos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A artroplastia metacarpofalângica com implante de silicone é a cirurgia de substituição articular mais comum ao nível da mão nos doentes com Artrite Reumatoide. Outros procedimentos estão disponíveis, nomeadamente a artroplastia de recessão e a artroplastia com componentes metálico e/ou polietileno. No entanto, os implantes de Swanson mantêm-se o gold standard deste tipo de cirurgia conferindo um maior grau de estabilidade em relação a outros tipos de artroplastias. A ação que o tratamento fisiátrico exerce nas estruturas abarticulares, tanto pelo alívio álgico como pela flexibilização articular e fortalecimento dos músculos naturalmente amiotrofiados pelo processo crónico é essencial. Um programa de reabilitação adequado e individualizado terá implicações essenciais na funcionalidade atingida. Os autores efetuaram uma breve revisão dos diferentes procedimentos cirúrgicos e propõem para cada tipo de prótese usada um programa de reabilitação pré e pós cirúrgicos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A utilização de revestimentos poliméricos em rolhas de cortiça natural é uma prática recorrente na indústria de produção de rolhas. A sua aplicação tem como principal objetivo a melhoria da qualidade visual das rolhas. Contudo, este tratamento altera também as suas caraterísticas de molhabilidade, pelo que é importante otimizar os processos de revestimento de superfície. O presente trabalho teve como objetivo principal a averiguação da influência de um revestimento colorido e de diferentes tratamentos de superfície no comportamento da rolha em garrafa. Foram utilizadas amostras, cedidas pela Cork Supply Portugal, provenientes de quatro branqueamentos distintos (LVL, CSP, CPI e SIL). Foram estudadas amostras com e sem revestimento colorido e, todas elas, tratadas superficialmente com quatro tipos de tratamento (TS1, TS2, TS3 e TS4), sendo as quantidades de parafina e silicone administradas todas diferentes. Para observar o efeito do revestimento colorido e dos tratamentos de superfície nas rolhas de cortiça, procedeu-se a testes para determinação de capilaridade, inserções e forças de extração, simulando as condições de engarrafamento/extração do cliente, de forma a verificar a conformidade dos resultados. Todos estes testes procederam-se nas instalações da CSP. Foram também efetuados testes de molhabilidade pela determinação de ângulos de contacto para três diferentes solventes, nomeadamente água, formamida e diiodometano, e obtidos os Wetting Envelopes, pelo método de OWRK, de forma a prever a molhabilidade das várias amostras. Os procedimentos experimentais descritos efetuaram-se nos laboratórios da Universidade de Aveiro. Aliando as análises aos vários testes efetuados, concluiu-se que o revestimento colorido tem um possível efeito favorecedor nas propriedades mecânicas das rolhas de cortiça, possui maior recetividade aos agentes lubrificantes e maior molhabilidade. Relativamente aos tratamentos de superfície, o melhor, tendo em conta os fatores de molhabilidade, foi o TS4, proporcionando melhor vedação ao vinho. Já a respeito da lubrificação, verificou-se melhores resultados para os tratamentos TS1 e TS2. A lavação SIL apresenta menor afinidade aos agentes vedantes e a CSP possui maior recetibilidade aos agentes lubrificantes.