990 resultados para SEALED VESSELS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the photodynamic potential of a new hydrosoluble photosensitizer (WST-11, Stakel; Steba Biotech, Toussus-Le-Noble, France), for use in occlusion of normal choroidal vessels in the rabbit eye and CNV (choroidal neovascularization) in the rat eye. METHODS: Occlusive and nonocclusive parameters of Stakel and verteporfin photodynamic therapy (PDT) were investigated in pigmented rabbits. Eyes were followed by fluorescein angiography (FA) and histology at various intervals after PDT. RESULTS: When occlusive parameters (fluence of 50 J/cm(2), 5 mg/kg drug dose and DLI [distance to light illumination] of 1 minute) were used, Stakel PDT was efficient immediately after treatment without associated structural damage of the RPE and retina overlying the treated choroid in the rabbit eye. Two days later, total occlusion of the choriocapillaries was seen in 100% of the treated eyes, along with accompanying histologic structural changes in the overlying retina. When the occlusive parameters (fluence, 100 J/cm2; drug dose, 12 mg/m2; and DLI, 5 minutes) of verteporfin PDT were used, occlusion of the choriocapillaries was observed in 89% of the treated eyes. Histology performed immediately after treatment demonstrated structural damage of the overlying retina and RPE layer. Weaker, nonocclusive Stakel PDT parameters (25 J/cm2, 5 mg/kg, and DLI of 10 minutes) did not induce choriocapillary occlusion or retinal lesions on FA or histology. Weaker, nonocclusive verteporfin PDT parameters (10 J/cm2, 0.2 mg/kg, and DLI of 5 minutes) did not induce choriocapillary occlusion. However, histology of these eyes showed the presence of damage in the retinal and choroidal tissues. Moreover, preliminary results indicate that selective CNV occlusion can be achieved with Stakel PDT in the rat eye. CONCLUSIONS: Unlike verteporfin PDT, Stakel PDT does not cause direct damage to the RPE cell layer or retina. These observations indicate that Stakel PDT may have a high potential for beneficial therapeutic outcomes in treatment of AMD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To assess the specific risks of injury to neural and vascular structures inherent in two approaches to transobturator surgery for inserting a suburethral sling, i.e. the outside-in (standard technique) and inside-out approaches. MATERIALS AND METHODS The study comprised seven cadavers, providing 14 obturator regions. Five specimens had a tape inserted outside-in on one side, and inside-out on the other; of the remaining two cadavers, one had an inside-out tape and one an outside-in tape, bilaterally. After tape insertion, the cadavers were dissected. Particular attention was paid to the distances between the tape and the deep external pudendal vessels, and between the tape and the posterior branch of the obturator nerve. RESULTS With the inside-out technique, the safety margins were reduced, and the external pudendal vessels and the posterior branch of the obturator nerve were at greater risk of injury. CONCLUSION The two techniques are not equivalent, with a lower risk of injury to vascular and nerve structures with the outside-in technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: In the present study, the impact of the two different fat suppression techniques was investigated for free breathing 3D spiral coronary magnetic resonance angiography (MRA). As the coronary arteries are embedded in epicardial fat and are adjacent to myocardial tissue, magnetization preparation such as T(2)-preparation and fat suppression is essential for coronary discrimination. MATERIALS AND METHODS: Fat-signal suppression in three-dimensional (3D) thin- slab coronary MRA based on a spiral k-space data acquisition can either be achieved by signal pre-saturation using a spectrally selective inversion recovery pre-pulse or by spectral-spatial excitation. In the present study, the performance of the two different approaches was studied in healthy subjects. RESULTS: No significant objective or subjective difference was found between the two fat suppression approaches. CONCLUSION: Spectral pre-saturation seems preferred for coronary MRA applications due to the ease of implementation and the shorter cardiac acquisition window.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The objective of our study was to investigate the impact of radial k-space sampling and steady-state free precession (SSFP) imaging on image quality in MRI of coronary vessel walls. SUBJECTS AND METHODS: Eleven subjects were examined on a 1.5-T MR system using three high-resolution navigator-gated and cardiac-triggered 3D black blood sequences (cartesian gradient-echo [GRE], radial GRE, and radial SSFP) with identical spatial resolution (0.9 x 0.9 x 2.4 mm3). The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and motion artifacts were analyzed. RESULTS: The mean SNR and CNR of the coronary vessel wall were improved using radial imaging and were best using radial k-space sampling combined with SSFP imaging. Vessel border definition was similar for all three sequences. Radial k-space sampling was found to be less sensitive to motion. Consistently good image quality was seen with the radial GRE sequence. CONCLUSION: Radial k-space sampling in MRI of coronary vessel walls resulted in fewer motion artifacts and improved SNR and CNR. The use of SSFP imaging, however, did not result in improved coronary vessel wall visualization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The susceptibility of blood changes after administration of a paramagnetic contrast agent that shortens T(1). Concomitantly, the resonance frequency of the blood vessels shifts in a geometry-dependent way. This frequency change may be exploited for incremental contrast generation by applying a frequency-selective saturation prepulse prior to the imaging sequence. The dual origin of vascular enhancement depending first on off-resonance and second on T(1) lowering was investigated in vitro, together with the geometry dependence of the signal at 3T. First results obtained in an in vivo rabbit model are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The management of sarcoma metastasis by systemic chemotherapy is often unsatisfactory. This has paradoxally been attributed to the leakiness of tumor neovessels which induce high intratumor interstitial fluid pressure (IFP) and limit convection forces that are important for drug distribution. In a rodent model, we have recently shown that photodynamic (PDT) pre treatment of lung metastasis could enhance their uptake of chemotherapy. We hypothesized that PDT transiently decreases tumor IFP which enhances convection and promotes drug distribution.Methods: Sarcoma tumors were generated sub-pleurally in the lungs of 12 rats. Animals were randomized at 10 days into i. no pre-treatment (control) and ii. low dose PDT pre-treatment (0・0625 mg/kg Visudyne, 10J/cm2 and 35 mW/cm2) followed by intravenous Liposomal doxorubicin (LiporubicinTM) administration. Using the wick-in-needle technique, we determined tumor and normal tissue IFP before, during and after PDT. In parallel, the uptake of LiporubicinTM was determined by high performance liquid chromatography in tumor and lung tissues.Results: Tumor IFP was significantly higher than normal tissue IFP in all animals. PDT pre-treatment did not affect normal tissue IFP but caused a significant decrease in tumor IFP (mean decrease by 2+/− 1mmHg) which lasted an average of 30 minutes before reaching baseline values. Tumor but not normal lung tissue LiporubicinTM uptake was significantly increased by 67% with PDT pre-treatment when liporubicin was allowed to circulate for one hour.Conclusion: Photodynamic therapy pre-treatment enhances LiporubicinTM uptake in sarcoma lung metastasis by transiently decreasing tumor IFP. These PDT conditions seem to specifically modulate tumor neovessels but not normal lung vessels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Brain tumors, benign or malignant, are characterized by a very high degree of vascularization. Recent accumulating evidence suggests that during development the neuronal wiring follows the same routes as the vasculature and that these two systems may share some of the same factors for guidance. Thus, expression of dual angiogenic/neurogenic growth factors was evaluated by in situ hybridization in human primary brain tumors of three different types, i.e., astrocytomas, oligodendrogliomas, and ependymomas, of increasing grades, in relation with the grade and type of the tumor. For this evaluation we selected vascular endothelial growth factor (VEGF-A) and its receptors VEGF-R1 and VEGF-R2 and the neuropilins 1 and 2 (NRP-1 and NRP-2), which have proangiogenic properties, platelet-derived growth factor (PDGF) receptor-beta (PDGF-Rβ), which is required for the functional maturation of blood vessels, the ephrins and their Eph receptors, angiotensinogen (AGT) and thrombospondin-2 (TSP-2), which have potential antiangiogenic properties, and netrin-1 (Net-1), which regulates vascular architecture. We show that the expression of the VEGF-NRP system, PDGF-Rβ, TSP-2, AGT, and Net-1 are differentially regulated, either increased or decreased, in relation with the type and grade of the tumor, whereas regulation of the ephrinB system does not seem to be relevant in these human brain tumors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Yet another 'orphan' molecule that had to find its place in life after isolation and sequencing, neuropeptide Y appears to be an important cardiovascular neuroregulator and also links the sympathetic and renin-angiotensin systems. The peptide's physiologic and pathophysiologic roles, as well as its potential therapeutic value, are examined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND/AIMS: The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. METHODS: Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. RESULTS: Functional analysis showed a significant decrease in global left ventricular ejection fraction (24.5 +/- 1.6%) 3 weeks after implantation. There was a trend to increased left ventricular ejection fraction after low-dose dobutamine stress (36.0 +/- 6.6%) and a significant improvement of the impaired regional anterior wall motion. PET and SPECT imaging documented chronic hibernation. Myocardial fibrosis increased significantly in the ischemic area with a gradient from epi- to endocardial. The number of arterial vessels in the ischemic area increased and coronary angiography showed abundant collateral vessels of Rentrop class 1. CONCLUSION: The presented experimental model mimics the clinical situation of chronic myocardial ischemia secondary to 1-vessel coronary disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Angiogenesis is an important process in chronic inflammatory diseases. We observed that sera from patients with systemic vasculitis stimulated angiogenesis in an in vitro model using human umbilical vein endothelial cells cultured on a basement membrane (Matrigel) substrate. After 40% ammonium sulfate precipitation, angiogenic activity remained in the low molecular weight fraction and could be inactivated by heat. SDS-page of serum FPLC fractions exhibiting maximal angiogenic activity demonstrated two prominent species of 45 and 16-20 kD in patients' sera. These bands were much less apparent in sera obtained from control subjects. Amino-terminal sequencing of the 45-kD protein demonstrated that it was haptoglobin. Purified haptoglobin stimulated angiogenesis in a dose-dependent manner. The angiogenic activity of vasculitis patients' sera was partially inhibited by an antihaptoglobin antibody. Furthermore, serum haptoglobin levels in vasculitis patients correlated both with disease and angiogenic activity. Haptoglobin angiogenic activity was confirmed in two in vivo models using an implanted disc and a subcutaneous injection of basement membrane. Stimulation of angiogenesis is a newly recognized biological function of haptoglobin. The increased levels of haptoglobin found in chronic inflammatory conditions may play an important role in tissue repair. In systemic vasculitis, haptoglobin might also compensate for ischemia by promoting development of collateral vessels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Résumé de l'article : L'hyperplasie intimale est un processus de remodelage vasculaire ubiquitaire après une lésion, pouvant menacer la perméabilité de tout type de reconstruction vasculaire. Les mécanismes physiopathologiques impliqués dans le développement de l'hyperplasie intimale ne sont que partiellement élucidés. Il est par conséquent nécessaire d'effectuer des recherches complémentaires afin d'en améliorer la compréhension et ainsi permettre l'élaboration de nouvelles stratégies thérapeutiques médicamenteuses. La culture de veines en milieu statique permet le développement de l'hyperplasie intimale. Ce modèle maintient la viabilité tissulaire, comme décrit précédemment dans d'autres études, mais empêche l'analyse des paramètres hémodynamiques. La mise au point d'un modèle de perfusion in vitro permettant la perfusion de segments vasculaires représente une approche expérimentale intégrant les différents facteurs hémodynamiques. Le système de perfusion (Ex Vivo Vein Support System) que nous avons élaboré conserve l'intégrité pariétale ainsi que les propriétés vasomotrices des veines pour une durée de 14 jours. Cette étude démontre que les deux modèles permettent le développement de l'hyperplasie intimale. Toutefois, les propriétés vasomotrices ainsi que l'influence des paramètres hémodynamiques ne peuvent être analysées que par l'utilisation du système de perfusion. Ce dernier a permis de perfuser des vaisseaux humains sans contamination bactérienne tout en maintenant l'intégrité cellulaire. Ce modèle de perfusion se rapproche plus des conditions hémodynamiques rencontrées in vivo que le modèle statique. Abstract : Background. Intimal hyperplasia (IH) is a vascular remodeling process which often leads to failure of arterial bypass or hemodialysis access. Experimental and clinical work have provided insight in IH development; however, further studies under precise con-trolled conditions are required to improve therapeutic strategies to inhibit IH development. Ex vivo perfusion of human vessel segments under standardized hemodynamic conditions may provide an adequate experimental approach for this purpose. Therefore, chronically perfused venous segments were studied and compared to traditional static culture procedures with regard to functional and histomorphologic characteristics as well as gene expression. Materials and methods. Static vein culture allowing high tissue viability was performed as previously described. Ex vivo vein support system (EVVSS) was performed using a vein support system consisting of an incubator with a perfusion chamber and a pump. EVVSS allows vessel perfusion under continuous flow while maintaining controlled hemodynamic conditions. Each human saphenous vein was divided in two parts, one cultured in a Pyrex dish and the other part perfused in EVVSS for 14 days. Testing of vasomotion, histomorphometry, expression of CD 31, Factor VIII, MIB 1, α-actin, and PAI-1 were determined before and after 14 days of either experimental conditions. Results, Human venous segments cultured under traditional or perfused conditions exhibited similar IH after 14 days as shown by histomorphometry. Smooth-muscle cell ( SMC) was preserved after chronic perfusion. Although integrity of both endothelial and smooth-muscle cells appears to be maintained in both culture conditions as confirmed by CD31, factor VIII and α-actin expression, a few smooth-muscle cells in the media stained positive for factor VIII. Cell-proliferation marker MIB-1 was also detected in the two settings and PAI-1 mRNA expression and activity increased significantly after 14 days of culture and perfusion. Conclusion. This study demonstrates the feasibility to chronically perfuse human vessels under sterile conditions with preservation of cellular integrity and vascular contractility. To gain insights into the mechanisms leading to IH, it will now be possible to study vascular remodeling not only under static conditions but also in hemodynamic environment mimicking as closely as possible the flow conditions encountered in reconstructive vascular surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditionally, thoracic aortic rupture, suspected after blunt thoracic trauma, is characterized by a chest radiograph showing a widened mediastinum. The diagnostic machinery consecutively activated still depends heavily on the pressure as additional traumatic lesions. A patient with additional cranio-cerebral trauma would typically undergo contrast-enhanced computed tomography or magnetic resonance imaging of head, chest, and other regions. In a number of patients these analyses would confirm the presence of blood in the mediastinum without formal proof of an aortic disruption. This is because mediastinal hematomas may be caused not only by an aortic rupture, but also by numerous other blood sources including fractures of the spine and other macro- and microvascular lesions providing similar images. Therefore, aortic angiography became our preferred diagnostic tool to identify or rule out acute traumatic lesions of not only the aorta but with great vessels. However recently, a number of traumatic aortic transsections have been identified by transoesophageal echocardiography (TEE). TEE has the additional advantage of being a bed-side procedure providing additional information about cardiac function. The latter analysis allows for identification and quantification of cardiac contusions, post-traumatic myocardial infarctions, and valvar lesions which are of prime importance to develop an adequate surgical strategy and to assess the risk of the numerous emergency procedures required in patients with polytrauma. The standard approach for repair of isthmic aortic rupture is through a lateral thoracotomy. Distal and proximal control of the aorta can be achieved in a substantial number of cases before complete aortic rupture occurs and a higher proportion of direct suture repair can be achieved under such circumstances. Most proximal descending aortic procedures are performed without cardiopulmonary bypass (clamp and go) but paraplegia may occur before, during, or after the procedure. Ascending aortic lesions and disruption of the aortic arch, the supra-aortic vessels, the main pulmonary arteries, the great veins as well as cardiac lesions are best approached through a sternotomy, which may have to be extended. Cardiopulmonary bypass allowing for deep hypothermia and circulatory arrest is often required and carries its own complications. It is not clear whether the increasing proportion of ascending aortic and cardiac lesions which are observed nowadays are due to a change in trauma mechanics (i.e., speed limits, seat belts, air-bags), an improvement of the diagnostic tools or both.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO(TM) is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. OBJECTIVE: To evaluate the potential of VEO(TM) on diagnostic image quality and dose reduction in pediatric chest CT examinations. MATERIALS AND METHODS: Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDIvol 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. RESULTS: At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. CONCLUSIONS: At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The objective of our study was to establish optimal perfusion conditions for high-resolution postmortem angiography that would permit dynamic visualization of the arterial and venous systems. MATERIALS AND METHODS: Cadavers of two dogs and one cat were perfused with diesel oil through a peristaltic pump. The lipophilic contrast agent Lipiodol Ultra Fluide was then injected, and angiography was performed. The efficiency of perfusion was evaluated in the chick chorioallantoic membrane. RESULTS: Vessels could be seen up to the level of the smaller supplying and draining vessels. Hence, both the arterial and the venous sides of the vascular system could be distinguished. The chorioallantoic membrane assay revealed that diesel oil enters microvessels up to 50 microm in diameter and that it does not penetrate the capillary network. CONCLUSION: After establishing a postmortem circulation by diesel oil perfusion, angiography can be performed by injection of Lipiodol Ultra Fluide. The resolution of the images obtained up to 3 days after death is comparable to that achieved in clinical angiography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.