998 resultados para Resistência nasal total
Resumo:
The rehabilitation process after total knee arthroplasty (TKA) relies more and more on the family doctor. Many factors contribute to this development: the constantly increasing number of TKA performed, the reduced length of stay at the hospital and the rehabilitation process after TKA requiring care for 3 to 4 months. After this time, it is also of major importance to encourage patients to take up physical activities in order to limit the negative effects of sedentarity. The goal of this paper is to give family doctors an overview of the current knowledge in the area of rehabilitation after TKA for physicians.
Resumo:
BACKGROUND AND PURPOSE: Electrical bioimpedance spectroscopy (BIS) allows the evaluation of limb extracellular fluid (R0) and total fluid (Rinf). BIS could facilitate post-surgical oedema evaluation after total knee arthroplasty (TKA), as it is easily performed and is non-invasive. However, neither its applicability in this context nor the influence of metallic implants on measurement has been evaluated. The aim of this study was to evaluate the influence of TKA implants on the BIS R0 and Rinf variables used for oedema evaluation. METHOD: This was a prospective non-randomized comparative clinical trial. One oedema-free group of patients with TKA was compared with a group presenting similar characteristics except for the arthroplasty, to assess the influence of the implant on BIS measurement in the absence of oedema. The TKA group included 15 patients who had undergone surgery more than a year previously, and the control group included 19 patients awaiting TKA surgery. Volume and perimeter measurements served as reference criterions. The lower limb percentage differences for BIS, knee perimeter and volume were calculated. The significance of differences between groups was calculated for all measurement methods, using the Mann-Whitney test. The setting was a Department of Orthopedic Surgery and Traumatology in a university hospital. RESULTS: The differences between groups were not significant for R0, Rinf, volume and perimeter. R0 showed the smallest mean difference in limb percentage difference between groups [means (SD): TKA 3.98 (8.09), controls 3.97 (5.16)]. CONCLUSIONS: The lower-leg percentage difference in the TKA group is comparable with that of healthy subjects. R0 can be used for oedema evaluation following TKA surgery, as there was no sign of alteration from the metallic implant. These findings indicate the potential for early oedema evaluation after TKA. More research is warranted to extensively validate the application of BIS for oedema evaluation after TKA. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
HYPOTHESIS: Supraspinatus deficiency associated with total shoulder arthroplasty (TSA) provokes eccentric loading and may induce loosening of the glenoid component. A downward inclination of the glenoid component has been proposed to balance supraspinatus deficiency. METHODS: This hypothesis was assessed by a numeric musculoskeletal model of the glenohumeral joint during active abduction. Three cases were compared: TSA with normal muscular function, TSA with supraspinatus deficiency, and TSA with supraspinatus deficiency and downward inclination of the glenoid. RESULTS: Supraspinatus deficiency increased humeral migration and eccentric loading. A downward inclination of the glenoid partly balanced the loss of stability, but this potential advantage was counterbalanced by an important stress increase within the glenoid cement. The additional subchondral bone reaming required to incline the glenoid component indeed reduced the bone support, increasing cement deformation and stress. CONCLUSION: Glenoid inclination should not be obtained at the expense of subchondral bone support.
Resumo:
Previous work on radius of gyration and average crossing number has demonstrated that polymers with fixed topology show a different scaling behavior with respect to these characteristics than polymers with unrestricted topology. Using numerical simulations, we show here that the difference in the scaling behavior between polymers with restricted and unrestricted topology also applies to the total curvature and total torsion. For each knot type, the equilibrium length with respect to a given spatial characteristic is the number of edges at which the value of the characteristic is the same as the average for all polygons. This number appears to be correlated to physical properties of macromolecules, for example gel mobility as measured by the separation between distinct knot types. We also find that, on average, closed polymers require slightly more total curvature and slightly less total torsion than open polymers with the corresponding number of monomers.
Resumo:
Analiza los efectos de El Niño sobre el peso total individual de la sardina y la caballa para lo cual se comparan los datos de una año normal con los obtenidos abordo del BIC
Resumo:
Estudia los requerimientos energéticos de la sardina juvenil en relación a su velocidad de natación
Resumo:
Presenta los resultados del análisis de la composición del contenido estomacal de 693 ejemplares de la merluza peruana. Determina el índice de importancia relativa (IIR) para cada una de sus presas, mostrando que, en número de individuos, las más importantes para esta especie son los crustáceos, seguidos por los teleósteos.
Resumo:
A variabilidade espacial das características cor do solo, conteúdo de argila, pH e resistência à penetração foi avaliada em sete glebas com solos fortemente intemperizados e intensamente cultivados, na região do Planalto Médio (RS), por meio da análise da variância pelo método de amostragem aninhada, com o objetivo de determinar sua homogeneidade e estimar o intervalo indicado para efetuar amostragens sistemáticas de solos. Perfis representativos foram caracterizados e classificados nessas glebas. O trabalho de campo foi realizado em agosto-novembro de 1989. Latossolos vermelho-escuro e amarelo distróficos e álicos ocorrem nas glebas estudadas. As características analisadas, exceto o valor da cor e o pH na camada de 60-80 cm, apresentaram grande variabilidade. A contribuição à variância total aumentou relativamente pouco nos intervalos de amostragem de 50 a 600 m. De 600 m à distância entre glebas (> 3000 m), ocorreu grande incremento na variância, indicando que intervalos de amostragem de 600 m ou maiores são suficientes para o estudo de características relacionadas à gênese do solo. Variâncias em características químicas e físicas, relacionadas ao manejo do solo, persistirão dentro de delineamentos produzidos nesse intervalo de amostragem. Os mesmos esquemas com intervalos de amostragem de 50 m não poderão resolver tais variâncias.
Resumo:
The unconfined compression strength is a geotechnical parameter frequently used to determine the bearing capacity of foundations on clayey soils. Its value can be obtained from the unconfined compression test and, among several in situ tests, the standard penetration test (SPT). However, a comparison between the values of such a strength determined by both tests in CL, CL-ML and CH soils shows that it does not exist an approximate relationship. In any case it is remarkable that values of the test conducted in the laboratory fit between the lower and the higher ones calculated from the standard penetration number. This is very important for those geotechnical reports in which the unconfined compression strength is only based on the SPT. In this way, if the lower value is taken to evaluate the ultimate soilbearing capacity the result will not be very accurate but it will probably be by the side of safety
Resumo:
Por el fondo de un valle de la provincia de Girona mana un conjunto de surgencias cuyo caudal total anual se acercaa medio centenar de hectómetros cúbicos. Controlando no solo la cantidad de agua de salida sino también su calidad desde el punto de vista de su contenido en tritio y a partir de un modelo conceptual de mezcla uniforme de las aguas de recarga, ya com probado en otros sistemas, se acota la cadencia de participación en las surgencias de las distintas recargas anuales, as como el tiempo de renovación del volumen de agua del sistema hidrogeológico
Resumo:
Foram avaliados os teores de boro total e solúvel, por meio de três extratores, usados como índices de disponibilidade para as plantas, e suas relações com as propriedades do solo em unidades de mapeamento representativas do estado do Ceará. Utilizaram-se 48 amostras compostas da camada superficial (0-20 cm) de solos classificados como: Areia Quartzosa (AQd), Aluvial (Ae), Planossolo (PL), Bruno Não-Cálcico (NC), Cambissolo (Ce), Podzólico Vermelho-Amarelo (PV), Latossolo Vermelho-Amarelo (LV) e Litossolo (Re). O boro total foi determinado após fusão com carbonato de sódio, e o boro solúvel por meio dos extratores: água quente, HCl 0,05 mol L-1 e Mehlich-1. O B total variou entre 8,3 e 52,2 mg kg-1, com média geral de 16,0 mg kg-1, verificando-se as menores médias nos solos NC, Re e AQd e as maiores nos solos LV, PL e PV. Os teores de B solúvel variaram entre 0,22 e 1,22 mg kg-1, com média de 0,60 mg kg-1, na água quente; entre 0,21 e 1,24 mg kg-1, com média de 0,53 mg kg-1, no HCl 0,05 mol L-1; e entre 0,50 e 1,81 mg kg-1, com média de 1,07 mg kg-1, no Mehlich-1, representando 3,76; 3,32 e 6,76% do B total, respectivamente. As menores médias foram apresentadas pelos solos AQd e LV, e as maiores pelo Ce. Os três extratores correlacionaram-se de forma positiva e altamente significativa. O B total e a matéria orgânica explicaram 28,8 e 38,3% do B extraído pela água quente, respectivamente. O conteúdo de argila, os óxidos de Mn e os sesquióxidos de Fe e Al amorfos e cristalinos influenciaram em menor proporção. A inclusão dessas características numa análise de regressão múltipla melhorou os coeficientes de correlação.
Resumo:
O estudo da distribuição de raízes no solo é um método adequado para se detectarem as condições adversas ou não ao seu desenvolvimento, bem como para avaliar o efeito das alterações introduzidas por sistemas de preparo do solo. Sendo assim, o objetivo deste trabalho foi avaliar o efeito de métodos de preparo sobre determinadas características do solo e, por conseguinte, sobre o desenvolvimento do sistema radicular do milho. Para tal, foi utilizado um experimento de campo, instalado em um solo Podzólico Vermelho-Escuro com cinco anos de utilização por preparo convencional, reduzido e semeadura direta, na sucessão aveia + trevo/milho. Para observar as modificações estruturais do solo, usou-se o método do perfil cultural adaptado, acompanhado por determinações de densidade do solo, porosidade total, macro e microporosidade e resistência ao penetrômetro. Os métodos da parede do perfil e do monolito (prancha com pregos) foram utilizados para determinar a distribuição e morfologia das raízes. Nos mapas estruturais descritos, observou-se que os modos de organização provocados pelos tratamentos explicaram parcialmente a presença das raízes no perfil. As plantas submetidas à semeadura direta, quando comparadas às do preparo convencional, tiveram o crescimento inicial das raízes diferindo do padrão diagonal normal e, ao final do ciclo, apresentaram raízes com maior raio médio nas profundidades de 10-15 e 25-35 cm e mostraram a densidade de comprimento (cm cm-3) maior na camada superficial (0-5 cm) e menor na camada de 10-15 cm. Os sistemas de preparo não afetaram a massa seca de raízes e o rendimento dos grãos de milho.
Resumo:
A compactação do solo é um problema comum que afeta diversas propriedades físicas do solo e o crescimento das plantas. Este trabalho foi desenvolvido em câmara de crescimento na Universidade Federal do Rio Grande do Sul, em Porto Alegre, em 1994, durante 35 dias (530 GD, 0ºC de temperatura base) e objetivou determinar os efeitos da resistência mecânica do solo no crescimento das raízes de trigo. Para tanto, foram utilizados vasos dispostos em delineamento completamente casualizado preenchidos com solo Podzólico Vermelho-Escuro álico. Os tratamentos constaram de compactação do solo que resultou em resistências de 1,0; 2,0; 3,5 e 5,5 MPa. A combinação de umidade gravimétrica e densidade do solo foi estabelecida para minimizar os possíveis efeitos de falta de água e oxigênio. Com o aumento da resistência do solo diminuíram o comprimento, a superfície e a matéria seca das raízes, aumentando, porém, seu raio. A menor exploração do solo pelas raízes causou o menor acúmulo de matéria seca na parte aérea e, especialmente, nas raízes. Os efeitos foram percebidos logo no início do desenvolvimento da planta. A resistência do solo, isoladamente, caracterizou-se como um fator de diminuição do crescimento radicular.