974 resultados para Relative disturbance sensitivity
CE coupling with end-column electrochemiluminescence detection for chiral separation of disopyramide
Resumo:
CE with electrochemiluminescence, (ECL) detection technique was successfully applied for the chiral separation of a kind of class IA antiarrhythmic racemic drug. To the best of our knowledge, this is the first report of ECL detection used in chiral CE. To get better detection sensitivity and good enantioresolution at the same time, the conditions of capillary inlet and outlet buffer were systematically optimized. Unlike the traditional chiral separation method, the buffers we used in the capillary inlet and outlet differed from each other in terms of buffer pH, ionic strength, type of BGE as well as buffer composition. Under the optimum conditions, baseline enantioseparation and highly sensitive detection of the enantiomers were achieved. Wide linear relationship of each enantiomer was achieved in the range of 5 x 10(-7) to 2 x 10(-5) mol/L with relative coefficients of 0.996 and 0.997, respectively. The detection limits were estimated to be 8 x 10(-8) and 1.0 X 10(-7) mol/L (S/N = 3) for the enantiomers, respectively. In addition, a successful application of this new method to the chiral separation of the racemic drug in spiked plasma samples confirmed the validity and applicability of the chiral CE-ECL method.
Resumo:
Thiol-terminated oligonucleotide was immobilized to gold surface by self-assembly method. A novel amplification strategy was introduced for improving the sensitivity of DNA. hybridization using biotin labeled protein-streptavidin network complex. This complex can be formed in a cross-linking network of molecules so that the amplification of the response signal will be realized due to the big molecular size of the complex. It could be proved from the impedance technique that this amplification strategy caused dramatic improvement of the detection sensitivity. These results give significant advances in the generality and sensitivity as it is applied to biosensing.
Resumo:
Sodium dodecyl sulfate(SDS) is a powerful solubilizing detergent which is often used during the separation of highly complex protein mixtures by one- or two-dimensional (2D) gel electrophoresis. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a widely used technique for mass spectrometric analysis of some protein molecules compared to other techniques. But the presence of SDS or some salts usually leads to signal deterioration when using MALDI-MS. A method for using nitrocellulose membrane as the solid-phase carrier combined with n-octyl-beta-D-glucopyranoside in the matrix highly enhances the sensitivity of the molecular mass determination of lysozyme. This technique has the advantage that the signal-to-noise of the molecular weight profile is improved compared with the mass spectrum and the profile is relatively easy to interpret.
Resumo:
We report capillary electrophoresis coupling to a solid-state electrochemiluminescence (ECL) detector for the first time. The solid-state ECL detector was fabricated by immobilizing the ECL reagent tris(2,2'-bipyridyf)ruthenium (TBR) in poly-(p-styrenesulfonate)-silica-poly(vinyl alcohol) grafting 4-vinylpyridine copolymer films. The excellent stability of the solid-state ECL detector in the phosphate solution satisfied application in CE. The CE with solid-state ECL detector system was characterized using tripropylamine (TPA) and proline. The influences of detection potential, the concentration of TBR in the film, and pH value of ECL buffer were investigated. The linear range for TPA and proline was 0.005-10 muM and 5-10 mM with correlation coefficients of 0.997 and 0.998, respectively. The detection limit (signal-to-noise ratio S/N = 3) was estimated to be 0.002 and 2.0 muM for TPA and proline, respectively. The relative standard deviations for 1.0 pm TPA and 1.0 mm proline were 8.7% and 7.5% with theoretical plate numbers of 70 000 and 16 000, respectively. Compared with the CE-ECL of TBR in aqueous solution, the CE coupling with solid-state ECL detector system gave the same sensitivity of analysis.
Resumo:
The formation process of monolayer of octa-n-butoxy-2,3-naphthalocyanine copper ( I), [CuNc(OBu)(8)], on water subphase was studied. Its multilayers were successifully deposited on the hydrophilic substrates by Z-type deposition mode using LB technique. Stable solid film with a limiting molecular area of 0.74 nm(2) and a collapse pressure of 55 mN/m were formed. The LB film structure was characterized by IR and electronic absorption spectra. Macrocycle of CuNc (OBu)(8) molecules have a face-to-face arrangement in the multilayers. These films have good sensitivities to vapor of alcohols, with the following sequence of sensitivities: i-PrOH>EtOH>MeOH. The response time and recovery time of the LB films to vapor of MeOH, EtOH and i-PrOH[volume fraction (1-5) X 10(-5)] were within 2 and 5 seconds respectively, while those of the LB films to ammonia(1 X 10(-4)) were 30-60 seconds and 4-5 minutes respectively.
Resumo:
Nanoparticulate ferric oxide - tris - (2,4-di-t-amylphenoxy) - (8-quinolinolyl) copper phthalocyanine Langmuir-Blodgett Z-type multilayers were obtained by using monodisperse nanoparticle ferric oxide hydrosol as the subphase. XPS data reveal that the nanoparticle ferric oxide exist as alpha -Fe2O3 phase in the films. Transition electron microscopic (TEM) image of the alternating monolayer shows that the film was highly covered by the copper phthalocyanine derivative and the nanoparticles were arranged rather closely. IR and visible spectra all give the results that the nanoparticles were deposited onto the substrate with the copper phthalocyanine derivative. The gas-sensing measurements show that the alternating LB film had very fast response-recovery characteristic to 2 ppm C2H5OH gas, and also sensitive to larger than 200 ppm NH3.
Resumo:
The Langmuir-Blodgett (LB) composite films, ferric oxide nanoparticle composite with tris-(2,3-di-t-amylphenoxy)-(8-quinolinolinolyl) copper phthalocyanine (CuPcA(2)), were obtained by capped type and alternated type and characterized by X-ray photoelectron spectroscopy (XPS) and visible spectra. The gas sensitivity of the composite films and the pure ferric oxide and pure CuPcA(2) LB films to ammonia and ethanol were measured at room temperature. The composite films could be used as the C2H5OH sensors in the range of 2-8 or 100-200 ppm. The XPS data suggested that the adduct complex NH3-CuPcA(2) was formed after the capped film was exposed to the detected gas of ammonia. (C) 2000 Elsevier Science B.V. All rights reserved.
Resumo:
Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of barbituric acid (BA) and 2-thiobarbituric acid (TA) has been described. Under optimum condition, BA and TA were separated satisfactorily, and a response of high sensitivity and stability was obtained at a detection potential of 1.25 V versus Ag/AgCl. Optimized end-column detection provides detection limit as low as 0.5 and 0.1 mu M for BA and TA, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 10) of peak currents and migration times obtained for both BA and TA were 3.4, 3.7, and 1.7, 1.2%, respectively. The proposed method has been applied to analyze water sample with satisfactory results. (C) 2000 Elsevier Science B.V. All rights reserved.
Resumo:
The A(m) index and molecular connectivity index were used for studying the photoionization sensitivity of some organic compounds in gas chromatography. The analysis of structure-property relationship between the photoionization sensitivity of the compounds and the A(m) indices or molecular connectivity indices has been carried out. The genetic algorighm was used to build the correlation model in this field. The results demonstrate that the property of compounds can be described by both A(m) indices and molecular connectivity indices, and the mathematical model obtained by the genetic algorithm was better than that by multivariate regression analysis.
Resumo:
Determination of aesculin (AL) and aesculetin (AT) by capillary electrophoresis with end-column amperometric detection using a 33 mu m microdisk carbon fiber electrode is described. The HDVs, the effect of pH, buffer concentration, injection voltage, injection time and separation voltage on the peak current response (i(p)) of the analytes and the number of theoretical plates (N) were studied. The method has high sensitivity and good reproducibility. Under the optimum condition - 10 mM, pH 9.00 phosphate buffer, 4 s at 9 kV injection, separation at 15 kV and +1.0 V as the detection potential - low detection limits (S/N = 3) of 0.06 and 0.3 mu M were obtained for AL and AT, respectively. The calibration curve was linear over three orders of magnitude. The relative standard deviations (n = 15) of peak current and migration time were 3.9% and 4.6%, and 0.96% and 0.75% for 15 consecutive injections of 5 mu M AL and AT, respectively. The use of this method for the separation and detection of the two compounds present in the traditional Chinese medicine and human urine samples is also reported. (C) 1999 Elsevier Science B.V. All rights reserved.
Application of the Sanchez-Lacombe lattice fluid theory to the system pvme/ps and model calculations
Resumo:
Cloud point curves reported in the literature for five representatives of the system poly(vinyl methyl ether)/polystyrene were evaluated theoretically by means of the Sanchez-Lacombe lattice fluid theory. The measured phase separation behavior can be described within experimental error using only one adjustable parameter (quantifying the interaction between the unlike mers). The Flory-Huggins interaction parameters calculated from this theoretical description depend in good approximation linearly on composition (volume fractions) and on the inverse temperature. An evaluation of these data yields a maximum heat effect which is almost one order of magnitude less (ca. -0.25 J/cm(3)) than obtained via Hess's cycle (dissolution of the components and of the blend) from calorimetric measurements. Model calculations on the basis of the present theory demonstrate that the critical points shift to a different extent upon a certain relative change in the molar mass of the blend components. The sensitivity of the calculated phase diagrams against changes in the scaling parameter decreases in the following order: interaction energies between unlike mers, differences in the scaling temperatures, pressures and densities.
Resumo:
In this paper, three topological indices, Am-1, Am-2, and Am-3, multivariate analysis in structure-property studies. The topological indices of twenty asymmetrical phosphosphono bisazo derivatives of chromotropic acid have been calculated. The structure-property relationships between color reagents and molar absorptivity of color reactions with yttrium have been studied by A(m) indices and structure selective factors. Good results have been obtained by using correlation equation to predict the molar absorptivity of new color reagents.
Resumo:
In this paper A, topological indices and molecular connectivity inidces have been applied to multivariate analysis in structure-property studies. The topological indices of twenty asymmetrical phosphone bisazo derivatives of chromotropic acid have been calculated. The structure-property relationships between color reagents and molar absorptivity of color reactions with ytterbium have been studied by A(m) indices and molecular connectivity indices. Good results have been obtained.
Resumo:
We propose a laser induced sensitized fluorescence spectrometry for measuring the spontaneous emission branching ratios o?the transitions from the ten levels 5f36d7s7p-7M7, 5f36d7s7p-7L6, 5f37s27p-5K6, 5f26d27s2 - 5L7, 5f46d7s - 7L6, (17,070cm-1)-5L6, 5f26d27s2-5K6, 6d7s7p-7L5, 5f36d7s7p-7K5 and 5f26d27s2-5I5 to the ground state of atomic uranium (UI) for the first time. Their relative oscillator strengths have been measured by means of hollow cathode discharge (HCD) emission spectrometry. The radiative...
Resumo:
Our rock magnetic analysis of core Ph05 from the West Philippine Sea demonstrates that the core preserves a strong, stable remanent magnetization and meets the magnetic mineral criteria for relative paleointensity (RPI) analyses. The magnetic minerals in the sequence are dominated by pseudosingle-domain magnetite, and the concentration of magnetic minerals is at the same scale. Both the conventional normalizing method and the pseudo-Thellier method were used in conjunction with the examination of the rock magnetic properties and natural remanent magnetization. Susceptibility (chi), anhysteretic remnant magnetization (ARM) and saturation isothermal remnant magnetization (SIRM) were used as the natural remanent magnetization normalizer. However, coherence analysis indicated that only ARM is more suitable for paleointensity reconstruction. The age model of core is established based on oxygen isotope data and AMS(14)C data, which is consistent with the age model estimated from RPI records. The relative paleointensity data provide a continuous record of the intensity variation during the last 200 ka, which correlates well with the global references RPI stacks. Several prominent low paleointensity values are identified and are correlated to the main RPI minima in the SINT-200 record, suggesting that the sediments have recorded the real changes of geomagnetic field.