976 resultados para Preclinical drug testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The material included within this report is the result of a series of tests of concrete specimens taken during the construction of various buildings in the cities of Pasadena and Los Angeles over a period of eight months.

The object of the problem is to determine the effect of the water ratio on the ultimate strength of the concrete as obtained from data observed and recorded from specimens taken from actual building practice rather than that from laboratory specimens made under ideal, or at least more nearly standard conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new type of wave-front analysis method for the collimation testing of laser beams is proposed. A concept of wave-front height is defined, and, on this basis, the wave-front analysis method of circular aperture sampling is introduced. The wave-front height of the tested noncollimated wave can be estimated from the distance between two identical fiducial diffraction planes of the sampled wave, and then the divergence is determined. The design is detailed, and the experiment is demonstrated. The principle and experiment results of the method are presented. Owing to the simplicity of the method and its low cost, it is a promising method for checking the collimation of a laser beam with a large divergence. © 2005 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

I. It was not possible to produce anti-tetracycline antibody in laboratory animals by any of the methods tried. Tetracycline protein conjugates were prepared and characterized. It was shown that previous reports of the detection of anti-tetracycline antibody by in vitro-methods were in error. Tetracycline precipitates non-specifically with serum proteins. The anaphylactic reaction reported was the result of misinterpretation, since the observations were inconsistent with the known mechanism of anaphylaxis and the supposed antibody would not sensitize guinea pig skin. The hemagglutination reaction was not reproducible and was extremely sensitive to minute amounts of microbial contamination. Both free tetracyclines and the conjugates were found to be poor antigens.

II. Anti-aspiryl antibodies were produced in rabbits using 3 protein carriers. The method of inhibition of precipitation was used to determine the specificity of the antibody produced. ε-Aminocaproate was found to be the most effective inhibitor of the haptens tested, indicating that the combining hapten of the protein is ε-aspiryl-lysyl. Free aspirin and salicylates were poor inhibitors and did not combine with the antibody to a significant extent. The ortho group was found to participate in the binding to antibody. The average binding constants were measured.

Normal rabbit serum was acetylated by aspirin under in vitro conditions, which are similar to physiological conditions. The extent of acetylation was determined by immunochemical tests. The acetylated serum proteins were shown to be potent antigens in rabbits. It was also shown that aspiryl proteins were partially acetylated. The relation of these results to human aspirin intolerance is discussed.

III. Aspirin did not induce contact sensitivity in guinea pigs when they were immunized by techniques that induce sensitivity with other reactive compounds. The acetylation mechanism is not relevant to this type of hypersensitivity, since sensitivity is not produced by potent acetylating agents like acetyl chloride and acetic anhydride. Aspiryl chloride, a totally artificial system, is a good sensitizer. Its specificity was examined.

IV. Protein conjugates were prepared with p-aminosalicylic acid and various carriers using azo, carbodiimide and mixed anhydride coupling. These antigens were injected into rabbits and guinea pigs and no anti-hapten IgG or IgM response was obtained. Delayed hypersensitivity was produced in guinea pigs by immunization with the conjugates, and its specificity was determined. Guinea pigs were not sensitized by either injections or topical application of p-amino-salicylic acid or p-aminosalicylate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We proposed a new method of measuring the degree of collimation of laser beam using axial intensity information near paraxial focus. Preceding methods for collimation testing are mainly either based on self-imaging or interferometric techniques. The new method is to employ the diffraction behavior of noncollimated wave in circular aperture diaphragm. The principle of the proposed method and experiment results are presented. Due to simplicity of the method and its low cost, it is a promising method for checking the collimation of laser beam. (c) 2005 Published by Elsevier GmbH.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Neonatal trials remain difficult to conduct for several reasons: in particular the need for study sites to have an existing infrastructure in place, with trained investigators and validated quality procedures to ensure good clinical, laboratory practices and a respect for high ethical standards. The objective of this work was to identify the major criteria considered necessary for selecting neonatal intensive care units that are able to perform drug evaluations competently. Methodology and Main Findings: This Delphi process was conducted with an international multidisciplinary panel of 25 experts from 13 countries, selected to be part of two committees (a scientific committee and an expert committee), in order to validate criteria required to perform drug evaluation in neonates. Eighty six items were initially selected and classified under 7 headings: "NICUs description - Level of care'' (21), "Ability to perform drug trials: NICU organization and processes (15), "Research Experience'' (12), "Scientific competencies and area of expertise'' (8), "Quality Management'' (16), "Training and educational capacity'' (8) and "Public involvement'' (6). Sixty-one items were retained and headings were rearranged after the first round, 34 were selected after the second round. A third round was required to validate 13 additional items. The final set includes 47 items divided under 5 headings. Conclusion: A set of 47 relevant criteria will help to NICUs that want to implement, conduct or participate in drug trials within a neonatal network identify important issues to be aware of. Summary Points: 1) Neonatal trials remain difficult to conduct for several reasons: in particular the need for study sites to have an existing infrastructure in place, with trained investigators and validated quality procedures to ensure good clinical, laboratory practices and a respect for high ethical standards. 2) The present Delphi study was conducted with an international multidisciplinary panel of 25 experts from 13 countries and aims to identify the major criteria considered necessary for selecting neonatal intensive care units (NICUs) that are able to perform drug evaluations competently. 3) Of the 86 items initially selected and classified under 7 headings - "NICUs description - Level of care'' (21), "Ability to perform drug trials: NICU organization and processes (15), "Research Experience'' (12), "Scientific competencies and area of expertise'' (8), "Quality Management'' (16), "Training and educational capacity'' (8) and "Public involvement'' (6) - 47 items were selected following a three rounds Delphi process. 4) The present consensus will help NICUs to implement, conduct or participate in drug trials within a neonatal network.