983 resultados para PL-100


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and Methods:Two models were made of photoelastic resin PL-2, with an internal hexagon implant of 4.00 x 13 mm and another with an external hexagon implant of 4.00 x 13 mm. Three denture designs were fabricated for each implant model, incorporating one type of connection in each one to connect implants and teeth: 1) welded rigid connection; 2) semirigid connection; and 3) rigid connection with occlusal screw. The models were placed in the polariscope, and 100-N axial forces were applied on fixed points on the occlusal surface of the dentures.Results:There was a trend toward less intensity in the stresses on the semirigid connection and solid rigid connection in the model with the external hexagon; among the three types of connections in the model with the internal hexagon implant, the semirigid connection was the most unfavorable one; in the tooth-implant association, it is preferable to use the external hexagon implant.Conclusions:The internal hexagon implant establishes a greater depth of hexagon retention and an increase in the level of denture stability in comparison with the implant with the external hexagon. However, this greater stability of the internal hexagon generated greater stresses in the abutment structures. Therefore, when this association is necessary, it is preferable to use the external hexagon implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to perform a photoelastic analysis of stress distribution on straight and angulated implants with different crowns (screwed and cemented). Three models were made of photoelastic resin PL-2: model 1: external hexagon implant 3.75 x 10.00 mm at 0 degrees; model 2: external hexagon implant 3.75 x 10.00 mm at 17 degrees; model 3: external hexagon implant 3.75 x 10.00 mm at 30 degrees. Axial and oblique (45 degrees) load (100 N) was applied with a universal testing machine. The photoelastic fringes on the models were recorded with a digital camera and visualized in a graphic software for qualitative analysis. The axial loading generated the same pattern of stress distribution. The highest stresses were concentrated between medium and apical thirds. The oblique loading generated a similar pattern of stress distribution in the models with similar implant angulation; the highest stress was located on the cervical region opposite to implant angulation and on the apical third. It was concluded that the higher the implant angulation, the higher the stress value, independent of crown type. The screwed prostheses exhibited the highest stress concentration. The oblique load generated higher stress value and concentration than the axial load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the stress distribution of platform switching implants using a photoelastic method. Three models were constructed of the photoelastic resin PL-2, with a single implant and a screw-retained implant-supported prosthesis. These models were Model A, platform 5.0 mm/abutment 4.1 mm; Model B, platform 4.1 mm/abutment 4.1 mm; and Model C, platform 5.00 mm/abutment 5.00 mm. Axial and oblique (45 degrees) loads of 100 N were applied using a Universal Testing Machine (EMIC DL 3000). Images were photographed with a digital camera and visualized with software (AdobePhotoshop) to facilitate the qualitative analysis. The highest stress concentrations were observed at the apical third of the 3 models. With the oblique load, the highest stress concentrations were located at the implant apex, opposite the load application. Stress concentrations decreased in the cervical region of Model A (platform switching), and Models A (platform switching) and C (conventional/wide-diameter) displayed similar stress magnitudes. Finally, Model B (conventional/regular diameter) displayed the highest stress concentrations of the models tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endo-polygalacturonase (endo-PG), exo-polygalacturonase (exo-PG) and pectin liase (PL) were produced by solid-state fermentation of a mixture of orange bagasse and wheat bran (1:1) with the filamentous fungus Penicillium viridicatum RFC3. This substrate was prepared with two moisture contents, 70% and 80%, and each was fermented in two types of container, Erlenmeyer flask and polypropylene pack. When Erlenmeyer flasks were used, the medium containing 80% of initial moisture afforded higher PL production while neither exo- nor endo-PG production was influenced by substrate moisture. The highest enzyme activities obtained were 0.70 U mL(-1) for endo-PG, 8.90 U mL(-1) for exo-PG, and 41.30 U mL(-1) for PL. However, when the fermentation was done in polypropylene packs, higher production of all three enzymes was obtained at 70% moisture (0.7 and 8.33 U mL(-1) for endo- and exo-PG and 100 U mL(-1) for PL). An increase in the pH and decrease in the reducing sugar content of the medium was observed. The fungus was able to produce pectin esterase and other depolymerizing enzymes such as xylanase, CMCase, protease and amylase. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Analisar retrospectivamente o resultado do estudo anatomopatológico de polipectomias colonoscópicas realizadas no Setor de Endoscopia da Faculdade de Medicina de Botucatu - UNESP durante os anos de 2002 e 2003. Material e Métodos: Estudamos retrospectivamente, a partir de procedimentos colonoscópicos realizados em nosso serviço, as características dos pólipos retirados: tamanho, localização e distribuição, bem como o motivo da indicação do mesmo e o resultado do estudo anatomopatológico. RESULTADOS: Num total de 100 polipectomias colonoscópicas realizadas em 75 pacientes, observamos que 63% dos pólipos localizava-se em reto e sigmóide e 15,8% no cólon descendente; o estudo anátomopatologico evidenciou que a grande maioria tinha características adenomatosas (54%). A idade dos pacientes variou entre 6 e 92 anos, não havendo predominância quanto ao sexo; a principal indicação para a realização de colonoscopia foi sangramento. CONCLUSÃO: Constatamos o importante papel diagnóstico e terapêutico das colonoscopias no que diz respeito ao câncer colorretal; os achados demonstram que, em nossa casuística, a maioria os pólipos colônicos são adenomatosos, pequenos e de localização distal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com o objetivo de analisar a aplicação de ácido giberélico (GA3) na germinação de sementes de Actinidia chinensis Pl, sementes foram extraídas de frutos maduros, lavadas e secas à sombra, recebendo os seguintes tratamentos: T1 - estratificação (5oC por 2 semanas); T2 - testemunha; T3 - GA3 à 50 mg.L-1 ; T4 - GA3 à 100 mg.L-1 e T5 - GA3 à 150 mg.L-1. Durante a primeira semana o substrato dos tratamentos T3, T4 e T5 foi umedecido com GA3. O tratamento mais efetivo para aumentar a porcentagem de germinação e diminuir o tempo médio de germinação foi com 150 mg.L-1 de GA3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to determine the technical viability of amniocentesis in sheep and to observe biochemical changes in the amniotic fluid components. Amniotic fluid samples were collected by puncture in the greatest curvature of the uterine hum at days 70, 100, and 145 of pregnancy. The surgical procedure for collection of amniotic fluid samples was safe and efficient. For three stages of pregnancy, the following results were obtained: pH values 8.36, 7.34 and 7.37; glucose concentrations, 16.06. 8.58, and 3.79 g/dl; urea values, 42.68, 33.53, and 25.49 mg/dl; creatinine, 0.85, 5.04, and 11.25 g/dl; Gama-GT enzyme, 12.58, 14.20, and 12.30 UI/l; sodium concentrations, 146.60, 129.42, and 103.8 mmol/l: potassium concentrations, 9.79, 6.15, and 8.65 mmol/l; chloride, 96.59, 85.28, and 65.35 mmol/l; total protein, 0.14, 0.23, and 0.24 g/dl, respectively. (C) 2001 Elsevier B.V. B.V. All rights reserved.