997 resultados para Oral Surgery
Resumo:
Objective. The aim was to evaluate the bleaching efficacy of sodium perborate/37% carbamide peroxide paste and traditional sodium perborate/distilled water for intracoronal bleaching. Study design. Thirty patients with dark anterior teeth were divided into 2 groups (n = 15): group A: sodium perborate/ distilled water; and group B: sodium perborate/37% carbamide peroxide paste. The bleaching treatment limited each patient to the maximum of 4 changes of the bleaching agent. Initial and final color shades were measured using the Vita Lumin shade guide. Results. Data was analyzed with Wilcoxon test for initial and final comparison according to the bleaching agent, demonstrating efficacy of the bleaching treatment with both agents. Mann-Whitney test was used for comparison of the efficacy of the bleaching agents, showing that there was no significant difference between them. Conclusion. The sodium perborate/37% carbamide peroxide association for intracoronal bleaching has proven to be as effective as sodium perborate/distilled water. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: e43-e47)
Resumo:
Among the factors that contribute to the papilla formation and crestal bone preservation between contiguous implants, this animal study clinically and radiographically evaluated the interimplant distances (IDs) of 2 and 3 mm and the placement depths of Morse cone connection implants restored with platform switch. Bilateral mandibular premolars of 6 dogs were extracted, and after 12 weeks, the implants were placed. Four experimental groups were constituted: subcrestally with ID of 2 mm (2 SCL) and 3 mm (3 SCL) and crestally with ID of 2 mm (2 CL) and 3 mm (3 CL). Metallic crowns were immediately installed with a distance of 3 mm between the contact point and the bone crest. Eight weeks later, clinical measurements were performed to evaluate papilla formation, and radiographic images were taken to analyze the crestal bone remodeling. The subcrestal groups achieved better levels of papillae formation when compared with the crestal groups, with a significant difference between the 3 SCL and 3 CL groups (P = .026). Radiographically, the crestal bone preservation was also better in the subcrestal groups, with statistically significant differences between the 2SCL and 2CL groups (P = .002) and between the 3SCL and 3CL groups (P = .008). With the present conditions, it could be concluded that subcrestal implant placement had a positive impact on papilla formation and crestal bone preservation, which could favor the esthetic of anterior regions. However, the IDs of 2 and 3 mm did not show significantly different results.
Resumo:
The regular use of mouthrinses, particularly when combined with the use of air-powder polishing, could affect the appearance of tooth-colored restorations. The current study sought to evaluate the effect of NaHCO(3) powder on translucency of a microfilled composite resin immersed in different mouthrinses, at distinct evaluation periods. Eighty disk-shaped specimens of composite resin (Durafill VS, Heraeus Kulzer GmbH & Co. KG, Hanau, Germany) were prepared. The composite specimens were then randomly allocated into two groups according to the surface treatment: exposure to NaHCO(3) powder (10 seconds) or nonexposure, and they were randomly assigned into four subgroups, according to the mouthrinses employed (N = 10): Periogard (Colgate/Palmolive, Sao Bernardo do Campo, SP, Brazil), Cepacol (Aventis Pharma, Sao Paulo, SP, Brazil), Plax (Colgate/Palmolive), and distilled water (control group). The samples were immersed for 2 minutes daily, 5 days per week, over a 4-month test period. Translucency was measured with a transmission densitometer at seven evaluation periods. Statistical analyses (analysis of variance and Tukey`s test) revealed that: distilled water presented higher translucency values (86.72%); Periogard demonstrated the lowest translucency values (72.70%); and Plax (74.05%) and Cepacol (73.32%) showed intermediate translucency values, which were statistically similar between them (p > 0.01). NaHCO(3) air-powder polishing increased the changes in translucency associated with the mouthrinses. Air-powder polishing alone had no effect on material translucency. Translucency percent was gradually decreased from 1 week of immersion up to 4 months. It may be concluded that the NaHCO(3) powder and the tested mouthrinses have affected the translucency of microfilled composite resin, according to the tested time. CLINICAL SIGNIFICANCE During the last decade, the demand for composite resin restorations has grown considerably, however, controversy persists regarding the effect of surface roughness on color stability.
Resumo:
Statement of problem. Color stability is an important factor to ensure the long-term clinical success of ceramic restorations. There is a lack of information on how color is affected by fabrication procedures, such as the number of firings. Purpose. The purpose of this study was to evaluate the effects that the number of firings and type of substrate have on the color stability of dental ceramic submitted to artificial accelerated aging. Material and methods. Sixty specimens were fabricated: 30 metal ceramic (Verabond II + IPS d.SIGN) and 30 all-ceramic (IPS d.SIGN). Specimens were divided into 3 groups (n=10), and submitted to 2, 3, or 4 firings (+/- 900 degrees C), respectively, according to the manufacturer`s instructions. Color readings were obtained with a spectro photometer before and after artificial accelerated aging, and L*, a*, and b* coordinates and total color variation (Delta E) were analyzed (2-way ANOVA, Bonferroni, (alpha=05). Results. For metal ceramic specimens, differences for the L* coordinates were significant (P<.05) only for the group submitted to 3 firings. With respect to the all-ceramic specimens, smaller L* coordinates were obtained for greater a* and b* coordinates, indicating that the greater the number of firings, the darker and more reddish/yellowish the specimen. All Delta E values, for all groups, were below 1.0. All-ceramic specimens submitted to 3 and 4 firings presented Delta E means differing statistically (P<.05) from those of the metal ceramic group. Conclusions. The type of substrate and number of firings affected the color stability of the ceramic material tested. Artificial accelerated aging did not produce perceptible color stability changes (Delta E<1.0). (J Prosthet Dent 2009-101:13-18)
Resumo:
Studying joint noise is an important parameter for diagnosing temporomandibular dysfunction. In this study, eight groups (n=9) were formed according to joint dysfunction classification, provided by employing vibration analysis equipment. Parameters for analyzing joint noise were: total vibration energy, peak amplitude, and peak frequency. Mouth opening range was also analyzed. Statistical analysis results for each parameter were significant at 1 %. Each analyzed group presented different noise characteristics. This allowed for inclusion of the groups within a determined value category. The patient group with normal condyle/disk relationship always presented the lowest values. The type of joint noise was characterized by analyzing total integral noise, peak amplitude, peak frequency, and mouth opening. Analyzing joint noise using electrovibratography suggests the type of joint dysfunction and may help to establish a diagnosis, as well as a treatment plan.
Resumo:
Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.
Resumo:
Purpose: To evaluate in vitro the influence of water flow rate on shear bond strength of a resin composite to enamel and dentin after Er:YAG cavity preparation. Methods: Ten bovine incisors were selected and roots removed. Crowns were sectioned in four pieces, resulting in 40 samples that were individually embedded in polyester resin (n=10), and ground to plane the enamel and expose the dentin. The bonding site was delimited and samples were randomly assigned according to cavity preparation: (1) Er:YAG/1.0 mL/minute; (2) Er:YAG/1.5 mL/minute; (3) Er:YAG/2.0 mL/minute and (4) High speed handpiece/bur (control group). Samples were fixed to a metallic device, where composite resin cylinders were prepared. Subsequently, they were stored for 24 hours and subjected to a shear bond strength test (500N at 0.5 mm/minute). Results: Means (MPa) were: enamel: 1: 12.8; 2: 16.8; 3: 17.5; 4: 36.0 and Dentin: 1: 13.6; 2: 18.7; 3: 12.1; 4: 21.3. Data were submitted to ANOVA and Tukey`s test. Adhesion to enamel was more efficient than for dentin. The cavities prepared with conventional bur (control) presented higher statistically significant bond strength values (P<0.05) than for Er:YAG laser for both enamel and dentin. No significant differences were observed between water flow rates employed during enamel ablation. For dentin, the shear bond strength of 2.0 mL/minute water flow rate was lower than for 1.5 mL/minute and 1.0 mL/minute rates. The Er:YAG laser adversely affected shear bond strength of resin composite to both enamel and dentin, regardless of the water flow rate used.
Resumo:
The information concerning the molecular events taking place in onlay bone grafts are still incipient. The objective of the present study is to correlate the effects of perforation of resident bone bed on (1) the timing of onlay autogenous graft revascularization; (2) the maintenance of volume/density of the graft (assessed through tomography); and (3) the occurrence of bone remodeling proteins (using immunohistochemistry technique) delivered in the graft. Thirty-six New Zealand White rabbits were subjected to iliac crest onlay bone grafting on both sides of the mandible. The bone bed was drill-perforated on one side aiming at accelerating revascularization, whereas on the other side it was kept intact. After grafts fixation and flaps suture all animals were submitted to tomography on both mandible sites. Six animals were sacrificed, respectively, at 3, 5, 7, 10, 20 and 60 days after surgery. A second tomography was taken just before sacrifice. Histological slides were prepared from each grafted site for both immunohistochemistry analysis [osteopontin, osteocalcin, type I collagen and vascular endothelial growth factor (VEGF) anti-bodies] and histometric analysis. The values on bone volume measured on tomography showed no statistic significance (P >= 0.05) between perforated and intact sites. Grafts placed on perforated beds showed higher bone density values compared with non-perforated ones at 3 days (P <= 0.05). This correlation was inverted at 60 days postoperatively. The findings from VEGF labeling revealed a tendency for earlier revascularization in the perforated group. The early revascularization of bone grafts accelerated the bone remodeling process (osteocalcin, type I collagen and osteopontin) that led to an increased bone deposition at 10 days. The extended osteoblast differentiation process at intermediate stages in the perforated group cooperated for a denser bone at 60 days.
Resumo:
In recent clinical studies, contamination of the inner parts of dental implants through bacterial penetration along the implant components has been observed. The aim of the present in-vitro study was to investigate leakage of Fusobacterium. nucleatum through the interface between implants and premachined or cast abutments. Both premachined (n = 10) and cast (n = 10) implant abutment assemblies were inoculated with 3.0 mu L of microbial inoculum. The assemblies were completely immersed in 5.0 mL of tryptic soy broth culture medium to observe leakage at the implant-abutment interface after 14 days of anaerobic incubation. Bacterial growth in the medium, indicative of microbial leakage, was found only in 1 out of 9 samples (11.1%) in each group. Both premachined and cast abutments connected to external hexagonal implants provide low percentages of bacterial leakage through the interface in in vitro unloaded conditions if the manufacturer`s instructions and casting procedures are properly followed.
Resumo:
Purpose: The aim of the study was to assess the in vitro bond strength (BS) of glass fiber posts (GF) and carbon fiber posts (CF) in the cervical, middle, and apical thirds of root canals cemented with RelyX-Unicem (RX) and Cement-Post (CP). Materials and Methods: Forty maxillary canines were divided into 4 groups (n = 10) according to the cement and post used: group 1: GF and RX; group 2: CF and RX; group 3: GF and CP; group 4: CF and CP. The push-out test was applied in the cervical, middle and apical thirds of each specimen to assess bond strength of the cement/post complex to the root canal wall. The data obtained were submitted to ANOVA (Bonferroni test, p < 0.05), and fracture analysis was done with SEM. Results: The GF posts presented the best results when cemented with RX and with CF (p < 0.05). RX presented the highest BS values for both GF and CF (p < 0.05). For all the groups, BS was higher in the cervical third, followed by the middle and apical thirds. Fracture analysis showed a predominance of cohesive fracture of posts for RX, and a predominance of adhesive fracture between dentin/cement, and mixed failure mode for CP. Conclusion: GF posts cemented with RX presented the highest BS values in all root thirds.
Resumo:
A favorable prognosis after tooth avulsion depends on some variables, such as the extra-alveolar period and storage medium. Vitality of the periodontal ligament cells is considered a critical factor for a successful outcome without root resorption. The dental surgeon is provided with clinical information and radiographic findings to establish a diagnosis and may rely on current available guidelines. Once trauma has occurred, treatment must be quick and effective, and periodic follow-up must be performed. Clinical, radiographic, and histologic characteristics for each type of root resorption due to tooth replantation are presented, with the aim to provide information for the diagnosis and treatment of healing complications.
Resumo:
This in vitro study evaluated the microtensile bond strength of a resin composite to Er:YAG-prepared dentin after long-term storage and thermocycling. Eighty bovine incisors were selected and their roots removed. The crowns were ground to expose superficial dentin. The samples were randomly divided according to cavity preparation method (I-Er:YAG laser and II-carbide bur). Subsequently, an etch & rinse adhesive system was applied and the samples were restored with a resin composite. The samples were subdivided according to time of water storage (WS)/number of thermocycles (TC) performed: A) 24 hours WS/no TC; B) 7 days WS/500 TC; C) 1 month WS/2,000 TC; D) 6 months WS/12,000 TC. The teeth were sectioned in sticks with a cross-sectional area of 1.0-mm(2), which were loaded in tension in a universal testing machine. The data were subjected to two-way ANOVA, Scheffe and Fisher`s tests at a 5% level. In general, the bur-prepared group displayed higher microtensile bond strength values than the laser-treated group. Based on one-month water storage and 2,000 thermocycles, the performance of the tested adhesive system to Er:YAG-laser irradiated dentin was negatively affected (Group IC), while adhesion of the bur-prepared group decreased only within six months of water storage combined with 12,000 thermocycles (Group IID). It may be concluded that adhesion to the Er:YAG laser cavity preparation was more affected by the methods used for simulating degradation of the adhesive interface.
Resumo:
P>Aim To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth. Methodology One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption. Conclusions In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.
Resumo:
The purpose of this study was to compare, by mechanical in vitro testing, a 2.0-mm system made with poly-L-DL-lactide acid with an analogue titanium-based system. Mandible replicas were used as a substrate and uniformly sectioned on the left mandibular angle. The 4-hole plates were adapted and stabilized passively in the same site in both groups using four screws, 6.0 mm long. During the resistance-to-load test, the force was applied perpendicular to the occlusal plane at three different points: first molar at the plated side; first molar at the contralateral side; and between the central incisors. At 1 mm of displacement, no statistically significant difference was found. At 2 mm displacement, a statistically significant difference was observed when an unfavourable fracture was simulated and the load was applied in the contralateral first molar and when a favourable fracture was simulated and the load was applied between the central incisors. At the failure displacement, a statistically significant difference was observed only when the favourable fracture was simulated and the load was applied on the first molar at the plated side. In conclusion, despite more failure, the poly-L-DL-lactic acid-based system was effective.
Resumo:
P>The use of seven domains for the Oral Health Impact Profile (OHIP)-EDENT was not supported for its Brazilian version, making data interpretation in clinical settings difficult. Thus, the aim of this study was to assess patients` responses for the translated OHIP-EDENT in a group of edentulous subjects and to develop factor scales for application in future studies. Data from 103 conventional and implant-retained complete denture wearers (36 men, mean age of 69 center dot 1 +/- 10 center dot 3 years) were assessed using the Brazilian version of the OHIP-EDENT. Oral health-related quality of life domains were identified by factor analysis using principal component analysis as the extraction method, followed by varimax rotation. Factor analysis identified four factors that accounted for 63% of the 19 items total variance, named masticatory discomfort and disability (four items), psychological discomfort and disability (five items), social disability (five items) and oral pain and discomfort (five items). Four factors/domains of the Brazilian OHIP-EDENT version represent patient-important aspects of oral health-related quality of life.