989 resultados para Operational conditions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We face the problem of characterizing the periodic cases in parametric families of (real or complex) rational diffeomorphisms having a fixed point. Our approach relies on the Normal Form Theory, to obtain necessary conditions for the existence of a formal linearization of the map, and on the introduction of a suitable rational parametrization of the parameters of the family. Using these tools we can find a finite set of values p for which the map can be p-periodic, reducing the problem of finding the parameters for which the periodic cases appear to simple computations. We apply our results to several two and three dimensional classes of polynomial or rational maps. In particular we find the global periodic cases for several Lyness type recurrences

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When colonizing a new habitat, populations must adapt their sexual behaviour to new ecological constraints. Because caves display drastically different conditions from surface habitats and cave animals are deprived from visual information, hypogean populations are expected to have modified their mate preference and signalling behaviour after cave colonization. Here, we experimentally examined the female preference and the sexual behaviour of brook newts Calotriton asper from different cave and river populations, either in light or in darkness. Our results suggest that females prefer large individuals in both hypogean and epigean populations, but that this preference is only expressed in the light conditions of their native habitat. Hence, some mate choice criteria would be maintained across genetically divergent populations and throughout dissimilar habitats. However, this sexual behaviour is likely to be expressed via a different sensory pathway in the different habitats, suggesting that a sensory shift has occurred in cave populations, enabling animals to communicate through a non-visual channel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Active personal dosemeters (APD) have been found to be very efficient tools to reduce occupational doses in many applications of ionizing radiation. In order to be used in interventional radiology and cardiology (IR/IC), APDs should be able to measure low energy photons and pulsed radiation with relatively high instantaneous personal dose equivalent rates. A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. In particular, eight commercial APDs were tested in continuous and pulsed X-ray fields delivered by calibration laboratories in order to evaluate their performances. Most of APDs provide a response in pulsed mode more or less affected by the personal dose equivalent rate, which means they could be used in routine monitoring provided that correction factors are introduced. These results emphasize the importance of adding tests in pulsed mode in type-test procedures for APDs. Some general recommendations are proposed in the end of this paper for the selection and use of APDs at IR/IC workplaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research reported in this series of article aimed at (1) automating the search of questioned ink specimens in ink reference collections and (2) at evaluating the strength of ink evidence in a transparent and balanced manner. These aims require that ink samples are analysed in an accurate and reproducible way and that they are compared in an objective and automated way. This latter requirement is due to the large number of comparisons that are necessary in both scenarios. A research programme was designed to (a) develop a standard methodology for analysing ink samples in a reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in forensic contexts. This report focuses on the last of the three stages of the research programme. The calibration and acquisition process and the mathematical comparison algorithms were described in previous papers [C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part I: Development of a quality assurance process for forensic ink analysis by HPTLC, Forensic Sci. Int. 185 (2009) 29-37; C. Neumann, P. Margot, New perspectives in the use of ink evidence in forensic science-Part II: Development and testing of mathematical algorithms for the automatic comparison of ink samples analysed by HPTLC, Forensic Sci. Int. 185 (2009) 38-50]. In this paper, the benefits and challenges of the proposed concepts are tested in two forensic contexts: (1) ink identification and (2) ink evidential value assessment. The results show that different algorithms are better suited for different tasks. This research shows that it is possible to build digital ink libraries using the most commonly used ink analytical technique, i.e. high-performance thin layer chromatography, despite its reputation of lacking reproducibility. More importantly, it is possible to assign evidential value to ink evidence in a transparent way using a probabilistic model. It is therefore possible to move away from the traditional subjective approach, which is entirely based on experts' opinion, and which is usually not very informative. While there is room for the improvement, this report demonstrates the significant gains obtained over the traditional subjective approach for the search of ink specimens in ink databases, and the interpretation of their evidential value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stage-discharge relations constitute a viable, alternative technique for estimating accurately flow for ungaged sites. In this research, we have utilized pressure transducers and Large Scale Particle Image Velocimetry techniques to develop stage-discharge relations at eleven sites in the Hungry Canyon Area (HCA) of southwestern Iowa under different hydrologic conditions. We have employed these data to calibrate and verify an established hydrologic model and then we have used this model to provide a stage discharge relation for different hydrologic conditions (i.e. rating curves). The benefits of the project are numerous including that the discharge data will be used for a number of purposes, including operational decision making in the HCA about the design of water-control and conveyance structures, input for hydraulic and hydrologic models, and calculation of sediment and other water quality constituents transport and “loads”, and for decision making. This project has also pointed out the difficulties in measuring flows in ungaged streams with ice jams, steep banks, erodible beds, and floating debris.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two portable Radio Frequency IDentification (RFID) systems (made by Texas Instruments and HiTAG) were developed and tested for bridge scour monitoring by the Department of Civil and Environmental Engineering at the University of Iowa (UI). Both systems consist of three similar components: 1) a passive cylindrical transponder of 2.2 cm in length (derived from transmitter/responder); 2) a low frequency reader (~134.2 kHz frequency); and 3) an antenna (of rectangular or hexagonal loop). The Texas Instruments system can only read one smart particle per time, while the HiTAG system was successfully modified here at UI by adding the anti-collision feature. The HiTAG system was equipped with four antennas and could simultaneously detect 1,000s of smart particles located in a close proximity. A computer code was written in C++ at the UI for the HiTAG system to allow simultaneous, multiple readouts of smart particles under different flow conditions. The code is written for the Windows XP operational system which has a user-friendly windows interface that provides detailed information regarding the smart particle that includes: identification number, location (orientation in x,y,z), and the instance the particle was detected.. These systems were examined within the context of this innovative research in order to identify the best suited RFID system for performing autonomous bridge scour monitoring. A comprehensive laboratory study that included 142 experimental runs and limited field testing was performed to test the code and determine the performance of each system in terms of transponder orientation, transponder housing material, maximum antenna-transponder detection distance, minimum inter-particle distance and antenna sweep angle. The two RFID systems capabilities to predict scour depth were also examined using pier models. The findings can be summarized as follows: 1) The first system (Texas Instruments) read one smart particle per time, and its effective read range was about 3ft (~1m). The second system (HiTAG) had similar detection ranges but permitted the addition of an anti-collision system to facilitate the simultaneous identification of multiple smart particles (transponders placed into marbles). Therefore, it was sought that the HiTAG system, with the anti-collision feature (or a system with similar features), would be preferable when compared to a single-read-out system for bridge scour monitoring, as the former could provide repetitive readings at multiple locations, which could help in predicting the scour-hole bathymetry along with maximum scour depth. 2) The HiTAG system provided reliable measures of the scour depth (z-direction) and the locations of the smart particles on the x-y plane within a distance of about 3ft (~1m) from the 4 antennas. A Multiplexer HTM4-I allowed the simultaneous use of four antennas for the HiTAG system. The four Hexagonal Loop antennas permitted the complete identification of the smart particles in an x, y, z orthogonal system as function of time. The HiTAG system can be also used to measure the rate of sediment movement (in kg/s or tones/hr). 3) The maximum detection distance of the antenna did not change significantly for the buried particles compared to the particles tested in the air. Thus, the low frequency RFID systems (~134.2 kHz) are appropriate for monitoring bridge scour because their waves can penetrate water and sand bodies without significant loss of their signal strength. 4) The pier model experiments in a flume with first RFID system showed that the system was able to successfully predict the maximum scour depth when the system was used with a single particle in the vicinity of pier model where scour-hole was expected. The pier model experiments with the second RFID system, performed in a sandbox, showed that system was able to successfully predict the maximum scour depth when two scour balls were used in the vicinity of the pier model where scour-hole was developed. 5) The preliminary field experiments with the second RFID system, at the Raccoon River, IA near the Railroad Bridge (located upstream of 360th street Bridge, near Booneville), showed that the RFID technology is transferable to the field. A practical method would be developed for facilitating the placement of the smart particles within the river bed. This method needs to be straightforward for the Department of Transportation (DOT) and county road working crews so it can be easily implemented at different locations. 6) Since the inception of this project, further research showed that there is significant progress in RFID technology. This includes the availability of waterproof RFID systems with passive or active transponders of detection ranges up to 60 ft (~20 m) within the water–sediment column. These systems do have anti-collision and can facilitate up to 8 powerful antennas which can significantly increase the detection range. Such systems need to be further considered and modified for performing automatic bridge scour monitoring. The knowledge gained from the two systems, including the software, needs to be adapted to the new systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Therapeutic drug monitoring (TDM) of imatinib has been increasingly proposed for chronic myeloid leukaemia (CML) patients, as several studies have found a correlation between trough concentrations (Cmin) >=1000ng/ml and improved response. The pharmacological monitoring project of EUTOS (European Treatment and Outcome Study) was launched to increase the availability of imatinib TDM, standardize labs, and validate proposed Cmin thresholds. Using the collected data, the objective of this analysis was to characterize imatinib Population pharmacokinetics (Pop-PK) in a large cohort of European patients, to quantify its variability and the influence of demographic factors and comedications, and to derive individual exposure variables suitable for further concentration-effect analyses.¦Methods: 4095 PK samples from 2478 adult patients were analyzed between 2006 and 2010 by LC-MS-MS and considered for Pop-PK analysis by NONMEM®. Model building used data from 973 patients with >=2 samples available (2590 samples). A sensitivity analysis was performed using all data. Available comedications (27%) were classified into inducers or inhibitors of P-glycoprotein, CYP3A4/5 and organic-cation-transporter-1 (hOCT-1).¦Results: A one-compartment model with linear elimination, zero-order absorption fitted the data best. Estimated Pop-PK parameters (interindividual variability, IIV %CV) for a 40-year old male patient were: clearance CL = 17.3 L/h (37.7%), volume V = 429L (51.1%), duration of absorption D1 = 3.2h. Outliers, reflecting potential compliance and time recording errors, were taken into account by estimating an IIV on the residual error (35.4%). Intra-individual residuals were 29.1% (proportional) plus ± 84.6 ng/mL (additive). Female patients had a 15.2% lower CL (14.6 L/h). A piece-wise linear effect of age estimated a CL of 18.7 L/h at 20 years, 17.3 L/h at 40 and 13.8 L/h at 60 years. These covariates explained 2% (CL) and 4.5% (V) of IIV variability. No effect of comedication was found. The sensitivity analysis expectedly estimated increased IIV, but similar fixed effect parameters.¦Conclusion: Imatinib PK was well described in a large cohort of CML patients under field conditions and results were concordant with previous studies. Patient characteristics explain only little IIV, confirming limited utility of prior dosage adjustment. As intra-variability is smaller than inter-patient variability, dose adjustment guided by TDM could however be beneficial in order to bring Cmin into a given therapeutic target.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this work were to evaluate two greenhouse screening methods for sudden death syndrome (SDS) and to determine which one is best correlated with field resistance of soybean genotypes. The evaluations were done with three sets of genotypes that were classified as partially resistant, intermediate, and susceptible to SDS based on previous field evaluations. These three sets were independently evaluated for greenhouse SDS reactions using cone and tray inoculation methods. Plants were infected using grains of white sorghum [Sorghum bicolor (L.) Moench] infested with Fusarium solani f. sp. glycines. Foliar symptom severity was rated 21 days after emergence. The cone and field SDS ratings were significantly correlated and ranged from 0.69 for set 1 to 0.51 for set 3. Correlations of SDS ratings of genotypes between field and greenhouse tray ratings were significant for set 1 and not significant for set 2. The cone method showed the highest correlation with field results and is recommended to screen soybean genotypes for SDS resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interferon-gamma release assays for the diagnosis of tuberculosis (TB) can give indeterminate results. The prevalence of indeterminate test results (ITRs) among T-SPOT.TB tests was assessed. A retrospective analysis of samples processed in 2005 was performed. ITRs were assessed by age, sex, immunosuppression, distance to the laboratory and season. A subgroup of tests performed for specific indications (contact tracing, migrants with positive tuberculin skin test, TB suspects and immunosuppression) were analysed separately. Of a total of 1,429 tests, 49 (3.4%) were indeterminate. ITRs were significantly associated with old age (>75 versus 5-75 yrs; odds ratio (OR) 7.97, 95% confidence interval (CI) 3.968-15.438) and the season during which samples were transported (autumn and winter versus spring and summer; OR 3.47, 95% CI 1.753-7.514). The incidence of ITR was 302 (2.0%) among TB contacts, 75 (1.6%) among immigrants, 156 (3.0%) in TB suspects and 32 (3.0%) among immunosuppressed patients. Sex, young age and distance to the laboratory were not associated with the rate of ITR. Of the 13 tests with ITR that were repeated, 10 gave a clear positive or negative result. Indeterminate test results with T-SPOT.TB under routine conditions were infrequent and more common in individuals aged >75 yrs than in children and younger adults. The incidence of indeterminate test results was low and similar among healthy tuberculosis contacts, immigrants with a positive tuberculin skin test, tuberculosis suspects and the immunosuppressed. The conditions of transportation may influence the incidence of indeterminate test results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hysteresis cycles are very important features of energy conversion and harvesting devices, such as batteries. The efficiency of these may be strongly affected by the physical size of the system. Here, we show that in systems which are small enough, the existence of physical boundaries which produce nonhomogeneities of the interaction potential gives rise to inflections and barriers in the associated free energy. This in turn brings on irreversible processes which can be triggered under suitable external conditions imposed by a heat bath. As an example, by controlling the temperature, the state of a small system may be impelled to oscillate between two different structural configurations or aggregation states avoiding equilibrium coexistence and therefore dissipating energy. This cyclical behavior associated with a hysteresis cycle may be prototypical of energy conversion, storage, or generating nanodevices, as exemplified by Li-ion insertion batteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro, macro and mesofauna in the soil often respond to fluctuating environmental conditions, resulting in changes of abundance and community structure. Effects of changing soil parameters are normally determined with samples taken in the field and brought to the laboratory, i.e. where natural environmental conditions may not apply. We devised a method (STAFD - soil tubes for artificial flood and drought), which simulates the hydrological state of soil in situ using implanted cores. Control tubes were compared with treatment tubes in which floods of 15, 30, 60 and 90 days, and droughts of 60, 90 and 120 days were simulated in the field. Flooding and drought were found to reduce number of individuals in all soil faunal groups, but the response to drought was slower and not in proportion to the expected decrease of the water content. The results of the simulated floods in particular show the value of the STAFD method for the investigation of such extreme events in natural habitats.