967 resultados para Odd third order intensity parameters


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). Material and methods: Filtek (TM) Z350 nanofilled composite resins and Amelogen (R) Plus, Vit-l-escence (TM) and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free Light (TM) 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm(-1)) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). Results: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey's test showed that the nanofilled resin (Filtek (TM) Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (Filtek (TM) Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free Light (TM) 2). Conclusions: The nanofilled resin showed the lowest DC, and the Vit-l-escence (TM) microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4748519]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare two modalities of exercise training (i.e., Endurance Training [ET] and High-Intensity Interval Training [HIT]) on health-related parameters in obese children aged between 8 and 12 years. Methods: Thirty obese children were randomly allocated into either the ET or HIT group. The ET group performed a 30 to 60-minute continuous exercise at 80% of the peak heart rate (HR). The HIT group training performed 3 to 6 sets of 60-s sprint at 100% of the peak velocity interspersed by a 3-min active recovery period at 50% of the exercise velocity. HIT sessions last similar to 70% less than ET sessions. At baseline and after 12 weeks of intervention, aerobic fitness, body composition and metabolic parameters were assessed. Results: Both the absolute (ET: 26.0%; HIT: 19.0%) and the relative VO2 peak (ET: 13.1%; HIT: 14.6%) were significantly increased in both groups after the intervention. Additionally, the total time of exercise (ET: 19.5%; HIT: 16.4%) and the peak velocity during the maximal graded cardiorespiratory test (ET: 16.9%; HIT: 13.4%) were significantly improved across interventions. Insulinemia (ET: 29.4%; HIT: 30.5%) and HOMA-index (ET: 42.8%; HIT: 37.0%) were significantly lower for both groups at POST when compared to PRE. Body mass was significantly reduced in the HIT (2.6%), but not in the ET group (1.2%). A significant reduction in BMI was observed for both groups after the intervention (ET: 3.0%; HIT: 5.0%). The responsiveness analysis revealed a very similar pattern of the most responsive variables among groups. Conclusion: HIT and ET were equally effective in improving important health related parameters in obese youth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To compare individuals with and without hyperhidrosis in terms of the intensity of palmar and plantar sweating. Methods: We selected 50 patients clinically diagnosed with palmoplantar hyperhidrosis and 25 normal individuals as controls. We quantified sweating using a portable noninvasive electronic device that has relative humidity and temperature sensors to measure transepidermal water loss. All of the individuals had a body mass index of 20-25 kg/cm(2). Subjects remained at rest for 20-30 min before the measurements in order to reduce external interference. The measurements were carried out in a climate-controlled environment (21-24 degrees C). Measurements were carried out on the hypothenar region on both hands and on the medial plantar region on both feet. Results: In the palmoplantar hyperhidrosis group, the mean transepidermal water loss on the hands and feet was 133.6 +/- 51.0 g/m(2)/h and 71.8 +/- 40.3 g/m(2)/h, respectively, compared with 37.9 +/- 18.4 g/m(2)/h and 27.6 +/- 14.3 g/m(2)/h, respectively, in the control group. The differences between the groups were statistically significant (p < 0.001 for hands and feet). Conclusions: This method proved to be an accurate and reliable tool to quantify palmar and plantar sweating when performed by a trained and qualified professional.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Forensic age estimation is an important element of anthropological research, as it produces one of the primary sources of data that researchers use to establish the identity of a person living or the identity of unknown bodily remains. The aim of this study was to determine if the chronology of third molar mineralization could be an accurate indicator of estimated age in a sample Brazilian population. If so, mineralization could determine the probability of an individual being 18 years or older. The study evaluated 407 panoramic radiographs of males and females from the past 5 years in order to assess the mineralization status of the mandibular third molars. The evaluation was carried out using an adaptation of Demirjian's system. The results indicated a strong correlation between chronological age and the mineralization of the mandibular third molars. The results indicated that modern Brazilian generation tends to demonstrate an earlier mandibular third molar mineralization than older Brazilian generation and people of other nationalities. Males reached developmental stages slightly earlier than females, but statistically significant differences between the sex were not found. The probability that an individual with third molar mineralization stage H had reached an age of 18 years or older was 96.8-98.6% for males and females, respectively. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims were both to determine lactate and ventilatory threshold during incremental resistance training and to analyze the acute cardiorespiratory and metabolic responses during constant-load resistance exercise at lactate threshold (LT) intensity. Ten healthy men performed 2 protocols on leg press machine. The incremental test was performed to determine the lactate and ventilatory thresholds through an algorithmic adjustment method. After 48 h, a constant-load exercise at LT intensity was executed. The intensity of LT and ventilatory threshold was 27.1 +/- 3.7 and 30.3 +/- 7.9% of 1RM, respectively (P=0.142). During the constant-load resistance exercise, no significant variation was observed between set 9 and set 15 for blood lactate concentration (3.3 +/- 0.9 and 4.1 +/- 1.4 mmol.L-1, respectively. P=0.166) and BORG scale (11.5 +/- 2.9 and 13.0 +/- 3.5, respectively. P=0.783). No significant variation was observed between set 6 and set 15 for minute ventilation (19.4 +/- 4.9 and 22.4 +/- 5.5L. min(-1), respectively. P=0.091) and between S3 and S15 for VO2 (0.77 +/- 0.18 and 0.83 +/- 0.16L. min(-1), respectively. P=1.0). Constant-load resistance exercise at LT intensity corresponds to a steady state of ventilatory, cardio-metabolic parameters and ratings of perceived exertion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper evaluates the photopolymerization kinetics and degree of conversion of different commercial dental composites when photoactivated by a LED curing unit using two different modes (standard and soft-start mode). The investigation was performed on with RelyX ARC (dual-cured), Filtek Z-350 (Nanocomposite), Filtek Z-250 (Hybrid), and Filtek Z-350flow (Flowable) resin composites. The analysis used was attenuated total reflection with a Fourier transform infrared (ATR-FTIR). The RelyX ARC resin demonstrated the highest degree of conversion with both LED photoactivation modes. For this resin a 28% decrease in maximum rate was observed and the time to reach its highest rate was almost 2.3 times higher than when the soft-start photoactivation light curing was used. Z-350flow resin recorder a higher maximum rate using the soft-start mode rather than the standard mode. In contrast, the Z-250 showed a higher value using the standard mode. Although Z-250 and Z-350 showed a higher total degree of conversion effectiveness using the soft-start mode, RelyX and Z-350flow achieved a higher value using the standard mode.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nitrogen removal coupled with sulfide oxidation has potential for the treatment of effluents from anaerobic reactors because they contain sulfide, which can be used as an endogenous electron donor for denitrification. This work evaluated the intrinsic kinetics of sulfide-oxidizing autotrophic denitrification via nitrate and nitrite in systems containing attached cells. Differential reactors were fed with nitrified synthetic domestic sewage and different sulfide concentrations. The intrinsic kinetic parameters of nitrogen removal were determined when the mass transfer resistance was negligible. This bioprocess could be described by a half-order kinetic model for biofilms. The half-order kinetic coefficients ranged from 0.425 to 0.658 mg N-1/2 L-1/2 h(-1) for denitrification via nitrite and from 0.190 to 0.609 mg N-1/2 L-1/2 h(-1) for denitrification via nitrate. In this latter, the lower value was due to the use of electrons donated from intermediary sulfur compounds whose formation and subsequent consumption were detected. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. Patients (n = 110) free of antibiotics, operated on by 3 surgeons ranging in clinical experiences, were evaluated for infection. Study Design. In the preoperative period and during the second and seventh postoperative days, the following parameters were analyzed: pain, infection, swelling, trismus, body temperature, C-reactive protein levels (CRP), and salivary neutrophil counts (SNC). During surgery, the following parameters were analyzed: systolic, diastolic, and mean arterial pressure; oximetry; heart rate; anesthesia quality; local anesthetic amount; bleeding; surgery difficulty; and surgery duration. Results. There were some differences in the surgery duration, local anesthetic amount, anesthesia quality, bleeding, pain experienced, trismus, CRP, and SNC, and no changes in hemodynamic parameters, rescue analgesic medication, wound healing, swelling, body temperature, confirmed case of dry socket, or any other type of local infection. Particularly, no systemic infections were found after lower third molar removal (LTMR). Conclusions. This study suggests that antibiotic prescriptions are unnecessary after LTMR when preoperative infections are absent. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114(suppl 5):S199-S208)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. Lower third molar removal provides a clinical model for studying analgesic drugs. The present study's aim was to compare the clinical efficacy of sublingual ketorolac and sublingual piroxicam in managing pain, trismus and swelling after lower third molar extraction in adult volunteers. Study Design. In this double-blinded, randomized, crossover investigation, 47 volunteers received for 4 days ketorolac sublingually (10 mg 4 times daily) and piroxicam sublingually (20 mg once daily) during 2 separate appointments after lower third molar extraction of symmetrically positioned lower third molars. A surgeon evaluated objective parameters (surgery duration, mouth opening, rescue analgesic medication, and facial swelling) and volunteers documented subjective parameters (postoperative pain and global evaluation), comparing postoperative results for a total of 7 days after surgery. The means of the objective and subjective parameters were compared for statistical significance (P < .05). Results. Volunteers reported low pain scores during the postoperative period when treated with either sublingual ketorolac or piroxicam. Also, volunteers ingested similar amounts of analgesic rescue medication (paracetamol) when they received either drug sublingually (P > .05). Additionally, values for mouth openings measured just before surgery and immediately after suture removal 7 days later were similar among volunteers (P > .05), and the type of nonsteroidal antiinflammatory drug (NSAID) used in this study showed no significant differences between swellings on the second or seventh days after surgery (P > .05). Conclusions. Pain, trismus, and swelling after lower third molar extraction, independent of surgical difficulty, were successfully controlled by sublingual ketorolac (10 mg 4 times daily) or sublingual piroxicam (20 mg once daily), and no significant differences were observed between the NSAIDs evaluated. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:27-34)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently high spectral resolution sensors have been developed, which allow new and more advanced applications in agriculture. Motivated by the increasing importance of hyperspectral remote sensing data, the need for research is important to define optimal wavebands to estimate biophysical parameters of crop. The use of narrow band vegetation indices (VI) derived from hyperspectral measurements acquired by a field spectrometer was evaluated to estimate bean (Phaseolus vulgaris L.) grain yield, plant height and leaf area index (LAI). Field canopy reflectance measurements were acquired at six bean growth stages over 48 plots with four water levels (179.5; 256.5; 357.5 and 406.2 mm) and tree nitrogen rates (0; 80 and 160 kg ha-1) and four replicates. The following VI was analyzed: OSNBR (optimum simple narrow-band reflectivity); NB_NDVI (narrow-band normalized difference vegetation index) and NDVI (normalized difference index). The vegetation indices investigated (OSNBR, NB_NDVI and NDVI) were efficient to estimate LAI, plant height and grain yield. During all crop development, the best correlations between biophysical variables and spectral variables were observed on V4 (the third trifoliolate leaves were unfolded in 50 % of plants) and R6 (plants developed first flowers in 50 % of plants) stages, according to the variable analyzed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of numerical simulation in the design and evaluation of products performance is ever increasing. To a greater extent, such estimates are needed in a early design stage, when physical prototypes are not available. When dealing with vibro-acoustic models, known to be computationally expensive, a question remains, which is related to the accuracy of such models in view of the well-know variability inherent to the mass manufacturing production techniques. In addition, both academia and industry have recently realized the importance of actually listening to a products sound, either by measurements or by virtual sound synthesis, in order to assess its performance. In this work, the scatter of significant parameter variations on a simplified vehicle vibro-acoustic model is calculated on loudness metrics using Monte Carlo analysis. The mapping from the system parameters to sound quality metric is performed by a fully-coupled vibro-acoustic finite element model. Different loudness metrics are used, including overall sound pressure level expressed in dB and Specific Loudness in Sones. Sound quality equivalent sources are used to excite this model and the sound pressure level at the driver's head position is acquired to be evaluated according to sound quality metrics. No significant variation has been perceived when evaluating the system using regular sound pressure level expressed in in dB and dB(A). This happens because of the third-octave filters that averages the results under some frequency bands. On the other hand, Zwicker Loudness presents important variations, arguably, due to the masking effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The two main tools to determine the dynamical and physical parameters of exoplanet systems are the radial velocity (RV) measurements and, when available, transit timings. The two techniques are complementary: The RV's allow us to know some of the orbital elements while the transit timings allow us to obtain the orbital inclination and planetary radius, impossible of obtain from the RV, and to resolve the indetermination in the determination of the planet mass from the RV's. The space observation of transiting planets is however not limited to transit times. They extend to long periods of time and are precise enough to provide information on variations along the orbit. Besides the effects of stellar rotation, deserve mention the Doppler shift in the radiation flux, as consequence of stellar movement around the center of mass, or Beaming Effect (BE); the Ellipsoidal Variability (EV) due to the tidal deformation of the star due to the gravitation of its close companion; and the Reflection (ER) of the stellar radiation incident on the planet and re-emitted to the observer. In the case of large hot Jupiters, these effects are enhanced by the strong gravitational interaction and the analysis of the light variation allows us independent estimates of the mass and radius of planet. The planetary system CoRoT 3 is favorable for such analysis. In this case, the secondary is a brown dwarf whose mass is of the order of 22Mj. We show results obtained from the analysis of 35 RV measurements, 236999 photometric observations and 11 additional RV observations made during a transit to determine the star rotation via the Rossiter-McLaughlin effect. The results obtained from this determination are presented in this communication. The results are compared to those resulting from other determinations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Structural properties of model membranes, such as lipid vesicles, may be investigated through the addition of fluorescent probes. After incorporation, the fluorescent molecules are excited with linearly polarized light and the fluorescence emission is depolarized due to translational as well as rotational diffusion during the lifetime of the excited state. The monitoring of emitted light is undertaken through the technique of time-resolved fluorescence: the intensity of the emitted light informs on fluorescence decay times, and the decay of the components of the emitted light yield rotational correlation times which inform on the fluidity of the medium. The fluorescent molecule DPH, of uniaxial symmetry, is rather hydrophobic and has collinear transition and emission moments. It has been used frequently as a probe for the monitoring of the fluidity of the lipid bilayer along the phase transition of the chains. The interpretation of experimental data requires models for localization of fluorescent molecules as well as for possible restrictions on their movement. In this study, we develop calculations for two models for uniaxial diffusion of fluorescent molecules, such as DPH, suggested in several articles in the literature. A zeroth order test model consists of a free randomly rotating dipole in a homogeneous solution, and serves as the basis for the study of the diffusion of models in anisotropic media. In the second model, we consider random rotations of emitting dipoles distributed within cones with their axes perpendicular to the vesicle spherical geometry. In the third model, the dipole rotates in the plane of the of bilayer spherical geometry, within a movement that might occur between the monolayers forming the bilayer. For each of the models analysed, two methods are used by us in order to analyse the rotational diffusion: (I) solution of the corresponding rotational diffusion equation for a single molecule, taking into account the boundary conditions imposed by the models, for the probability of the fluorescent molecule to be found with a given configuration at time t. Considering the distribution of molecules in the geometry proposed, we obtain the analytical expression for the fluorescence anisotropy, except for the cone geometry, for which the solution is obtained numerically; (II) numerical simulations of a restricted rotational random walk in the two geometries corresponding to the two models. The latter method may be very useful in the cases of low-symmetry geometries or of composed geometries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

LLong-chain fatty acids are capable of inducing alterations in the homoeostasis of glucose-stimulated insulin secretion (GSIS), but the effect of medium-chain fatty acids (MCFA) is poorly elucidated. In the present study, we fed a normoenergetic MCFA diet to male rats from the age of 1 month to the age of 4 months in order to analyse the effect of MCFA on body growth, insulin sensitivity and GSIS. The 45% MCFA substitution of whole fatty acids in the normoenergetic diet impaired whole body growth and resulted in increased body adiposity and hyperinsulinaemia, and reduced insulin-mediated glucose uptake in skeletal muscle. In addition, the isolated pancreatic islets from the MCFA-fed rats showed impaired GSIS and reduced protein kinase Ba (AKT1) protein expression and extracellular signal-related kinase isoforms 1 and 2 (ERK(1/2)) phosphorylation, which were accompanied by increased cellular death. Furthermore, there was a mildly increased cholinergic sensitivity to GSIS. We discuss these findings in further detail, and advocate that they might have a role in the mechanistic pathway leading to the compensatory hyperinsulinaemic status found in this animal model.