998 resultados para OPTIC RADIATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review considers the effects of ionizing radiation on the retina and examines the relationship between the natural course of radiation retinopathy and the radiobiology of the retinal vascular endothelial cell (RVEC). Radiation retinopathy presents clinically as a progressive pattern of degenerative and proliferative vascular changes, chiefly affecting the macula, and ranging from capillary occlusion, dilation, and microaneurysm formation, to telangiectasia, intraretinal microvascular abnormalities, and neovascularization. The total-radiation dose and fractionation schedule are the major determinants for the time of onset, rate of progression, and severity of retinopathy, although other factors such as concomitant chemotherapy and preexisting diabetes may exaggerate the vasculopathy by intensifying the oxygen-derived free-radical assault on the vascular cells. The differential radiosensitivity of RVECs is attributed to their nuclear chromatin conformation, their antioxidant status, and their environment. We propose pathogenetic mechanisms for radiation retinopathy and suggest that the peculiar latency and unique clinical pattern is related to the life cycle of the RVEC. A rationale is also proposed for the use of radiotherapy in the treatment of subneovascularization and age-related macular degeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combined effect of STZ-diabetes and ionising radiation on the rat retina was investigated. Wistar rats, which had been diabetic for 6 months, were irradiated with a single dose of x-rays (1500 cGy) and the ultrastructural effects evaluated at 4-10 mths post-irradiation. At 4 months post-irradiation, the outer nuclear layer of the retina was greatly reduced in thickness and the photoreceptor outer segments were disorganised and reduced in length. In addition, the nerve fibre layer contained many cytoid bodies and there were many redundant basement membrane tubes throughout the inner retina. By 6 months post-irradiation, the photoreceptor cells were virtually absent, bringing the external limiting membrane into close apposition to the RPE. Throughout large areas of the outer retina, RPE cells were hypertrophic and some had proliferated into the inner retina. In many regions, proliferating retinal capillaries were observed within the RPE layer, and at 8 months post-irradiation, some vessels extended into the inner retina accompanied by RPE cells. At 10 months post-irradiation, the RPE was atrophic and degenerative with retinal glial cells coming into contact with Bruch's membrane. In some areas, the glia which had breached Bruch's membrane had invaded the underlying choroid. Where glial cells contacted the choriocapillaries, the vessels assumed the appearance of retinal vessels with plump endothelia and no fenestrations. This study has described a progressive inner retinal ischemia, with cytoid bodies, capillary non-perfusion and general atrophy of the inner retina intensifying markedly with increasing post-irradiation time.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical impression that pre-existing diabetes exacerbates radiation injury to the retinal vasculature was studied in STZ diabetic rats. Half of 2 groups of streptozotocin (STZ)-induced diabetic rats and 1 group of normal animals had their right eyes irradiated with 1000 cGy of 90 KVP x-rays. The prevalence of acellular capillaries in trypsin digests of the retinal vasculature was quantified for each of the 6 groups of animals at 6.5 months post-irradiation. The prevalence of acellular capillaries in both non-irradiated diabetic groups was significantly higher than in controls while the irradiated animals in each of the three main categories showed a statistically significant increase compared to their non-irradiated equivalents. However, the net increase in acellular capillaries following irradiation was much greater in rats with an 8 month term of pre-existing diabetes (180%) than in those which had only been diabetic for 3 months (36%). The results of this study suggest a synergistic relationship between pre-existing diabetes and ionising radiation in the development of retinal vasculopathy, and that the potentiation of the vascular damage is dependent on the duration of diabetes prior to radiation exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical, pathological and experimental studies of radiation retinopathy confirm that the primary vascular event is endothelial cell loss and capillary closure. Pericytes are less susceptible, but typically atrophy as the capillaries become non-functional. The immediate effects of radiation reflect interphase and early mitotic death of injured endothelial cells, whereas later changes may be attributed to delayed mitotic death of compromised endothelial cells as they attempt division in the ordinary course of repair and replacement. Capillary occlusion leads to the formation of dilated capillary collaterals which may remain serviceable and competent for years. Microaneurysms develop in acellular and poorly supported capillaries, predominantly on the arterial side of the circulation and adjacent to regions of poorly perfused retina. Alterations in haemodynamics produce large telangiectatic-like channels which, typically develop a thick collagenous adventitia and may become fenestrated. Limited capillary regeneration occurs, usually evident as recanalisation of arterioles or venules by new capillaries. Vitreo-retinal neovascularisation may occur where retinal ischaemia is widespread. Radiation produces an exaggerated vasculopathy in patients with diabetes mellitus, and five month streptozotocin-induced diabetic rats develop a severe ischaemic retinopathy with vitreoretinal neovascularisation when exposed to 1500 cGy of radiation. Later photocoagulation is useful in containing or reversing microvascular incompetence and vasoproliferation in some patients with advanced radiation retinopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the clinical and histological side effects of a prototype stereotactic radiotherapy system delivering microcollimated external beam radiation through pars plana in porcine eyes.

Methods: Five Yucatan mini-swine (10 eyes) were randomized to five treatment groups. Eight eyes were dosed with X-ray radiation on Day 1, and two eyes served as untreated controls. Treated eyes received doses up to 60 Gy to the retina and up to 130 Gy to the sclera using single or overlapping beams. The treatment beams were highly collimated such that the diameter was approximately 2.5 mm on the sclera and 3 mm on the retinal surface. Fundus photography, fluorescein angiography (FA), and spectral domain optical coherence tomography (SD-OCT) were obtained on days 7, 30, 60, and 110. Images were examined by a masked grader and evaluated for abnormalities. Animals were sacrificed on day 111 and gross and histopathological analysis was conducted.

Results: Histological and gross changes to eye structures including conjunctiva and lens were minimal at all doses. Fundus, FA, and SD-OCT of the targeted region failed to disclose any abnormality in the control or 21 Gy treated animals. In the 42 and 60 Gy animals, hypopigmented spots were noted after treatment on clinical exam, and corresponding hyperfluorescent staining was seen in late frames. No evidence of choroidal hypoperfusion was seen. The histological specimens from the 60 Gy animals showed photoreceptor loss and displacement of cone nuclei.

Conclusion: Transcleral stereotactic radiation dosing in porcine eyes can be accomplished with no significant adverse events as doses less than 42 Gy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract
PURPOSE:
The optimal duration over which lung SBRT should be delivered is unknown. We conducted a randomized pilot study in patients treated with four fractions of lung SBRT delivered over 4 or over 11days.
METHODS:
Patients with a peripheral solitary lung tumor (NSCLC or pulmonary metastasis) ?5cm were eligible. For NSCLC lung tumors ?3cm, a dose of 48Gy in 4 fractions was used, otherwise 52Gy in 4 fractions was delivered. Patients were randomized to receive treatment over 4 consecutive days or over 11days. The primary end-point was acute grade ?2 toxicity. Secondary end-points included quality of life (QOL) assessed using the EORTC QLQ-C30 and QLQ-LC13 questionnaires.
RESULTS:
Fifty four patients were enrolled. More patients in the 11day group had respiratory symptoms at baseline. 55.6% patients treated over 4days and 33.3% of patients treated over 11days experienced acute grade ?2 toxicity (p=0.085). Dyspnea, fatigue and coughing domains were worse in the 11day group at baseline. At 1 and 4months, more patients in the 4day group experienced a clinically meaningful worsening in the dyspnea QOL domain compared to the 11day group (44.5% vs 15.4%, p=0.02; 38.5% vs 12.0%, p=0.03, respectively). However, raw QOL scores were not different at these time-points between treatment groups.
CONCLUSIONS:
Grade 2 or higher acute toxicity was more common in the 4day group, approaching statistical significance. More patients treated on 4 consecutive days reported a clinically meaningful increase in dyspnea, although interpretation of these results is challenging due to baseline imbalance between treatment groups. Larger studies are required to validate these results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the design, commissioning, and evaluation of a ?ber-optic strain sensor system for the structural health monitoring of a prestressed concrete posttensioned box girder railway bridge in Mumbai, India, which shows a number of well-documented structural problems. Preliminary laboratory trials to design the most appropriate sensor system that could be readily transported and used on site are described, followed by a description of load tests on the actual bridge undertaken in collaboration with Indian Railways and using locomotives of known weight. Results from the load tests using the optical system are compared with similar results obtained using electrical resistance strain gages. Conclusions are summarized concerning the integrity of the structure and for the future use of the sensor system for monitoring bridges of this type. Crack width measurements obtained during the load tests are also described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose
Recent in vitro results have shown significant contributions to cell killing from signaling effects at doses that are typically used in radiation therapy. This study investigates whether these in vitro observations can be reconciled with in vivo knowledge and how signaling may have an impact on future developments in radiation therapy.
Methods and Materials
Prostate cancer treatment plans were generated for a series of 10 patients using 3-dimensional conformal therapy, intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy techniques. These plans were evaluated using mathematical models of survival following modulated radiation exposures that were developed from in vitro observations and incorporate the effects of intercellular signaling. The impact on dose-volume histograms and mean doses were evaluated by converting these survival levels into "signaling-adjusted doses" for comparison.
Results
Inclusion of intercellular communication leads to significant differences between the signalling-adjusted and physical doses across a large volume. Organs in low-dose regions near target volumes see the largest increases, with mean signaling-adjusted bladder doses increasing from 23 to 33 Gy in IMRT plans. By contrast, in high-dose regions, there is a small decrease in signaling-adjusted dose due to reduced contributions from neighboring cells, with planning target volume mean doses falling from 74 to 71 Gy in IMRT. Overall, however, the dose distributions remain broadly similar, and comparisons between the treatment modalities are largely unchanged whether physical or signaling-adjusted dose is compared. Conclusions Although incorporating cellular signaling significantly affects cell killing in low-dose regions and suggests a different interpretation for many phenomena, their effect in high-dose regions for typical planning techniques is comparatively small. This indicates that the significant signaling effects observed in vitro are not contradicted by comparison with clinical observations. Future investigations are needed to validate these effects in vivo and to quantify their ranges and potential impact on more advanced radiation therapy techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Respiratory motion introduces complex spatio-temporal variations in the dosimetry of radiotherapy and may contribute towards uncertainties in radiotherapy planning. This study investigates the potential radiobiological implications occurring due to tumour motion in areas of geometric miss in lung cancer radiotherapy. A bespoke phantom and motor-driven platform to replicate respiratory motion and study the consequences on tumour cell survival in vitro was constructed. Human non-small-cell lung cancer cell lines H460 and H1299 were irradiated in modulated radiotherapy configurations in the presence and absence of respiratory motion. Clonogenic survival was calculated for irradiated and shielded regions. Direction of motion, replication of dosimetry by multi-leaf collimator (MLC) manipulation and oscillating lead shielding were investigated to confirm differences in cell survival. Respiratory motion was shown to significantly increase survival for out-of-field regions for H460/H1299 cell lines when compared with static irradiation (p <0.001). Significantly higher survival was found in the in-field region for the H460 cell line (p <0.030). Oscillating lead shielding also produced these significant differences. Respiratory motion and oscillatory delivery of radiation dose to human tumour cells has a significant impact on in- and out-of-field survival in the presence of non-uniform irradiation in this in vitro set-up. This may have important radiobiological consequences for modulated radiotherapy in lung cancer. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac.

Methods and Materials: Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dose measurements, 2-dimensional planar ionization chamber array measurements, and the corresponding Varian dynamic log files. Absolute point dose measurements, fluence delivery accuracy, leaf position accuracy, and the overshoot effect were assessed for each plan.

Results: Absolute point dose delivery accuracy increased by 1.5% on the Truebeam compared with the 2100CD linac. No improvement in fluence delivery accuracy between the linacs, at a gamma criterion of 3%/3 mm was measured using the 2-dimensional ionization chamber array, with median (interquartile range) gamma passing rates of 98.99% (97.70%-99.72%) and 99.28% (98.26%-99.75%) for the Truebeam and 2100CD linacs, respectively. Varian log files also showed no improvement in fluence delivery between the linacs at 3%/3 mm, with median gamma passing rates of 99.97% (99.93%-99.99%) and 99.98% (99.94%-100%) for the Truebeam and 2100CD linacs, respectively. However, log files revealed improved leaf position accuracy and fluence delivery at 1%/1 mm criterion on the Truebeam (99.87%; 99.78%-99.94%) compared with the 2100CD linac (97.87%; 91.93%-99.49%). The overshoot effect, characterized on the 2100CD linac, was not observed on the Truebeam.

Conclusions: The integrated multileaf collimator controller on the Varian Truebeam improves clinical treatment delivery accuracy of step and shoot intensity modulated radiation therapy fields compared with delivery on a Varian C-series linac. © 2014.