926 resultados para Nucleic acid detection tests


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Global Program for the Elimination of Lymphatic Filariasis (GPELF) aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR)-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2) and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2), which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To compare the results of rapid PCR screening for MRSA using the GeneXpert system with those of cultures in an outbreak setting. Methods: GeneXpert was used for screening MRSA in nose, throat, groin, and other clinical samples during a 6-month period. Samples were performed using a double-swab transystem. When >1 sample was found positive in a screening set, all second swabs of the set were analysed by culture. Results: From June to October 2009, 7568 rapid tests were performed, among which 432 (5.7%) were positive (nose: 149/2090, 7.1%; throat: 98/2078, 4.7%; groin: 152/2080, 7.3%; urine: 14/1090, 1.3%; wounds: 18/150, 12%; and others:1/27, 3.7%), and 84 (1.1%) were invalid. A total of 1517 samples were analyzed by both rapid PCR and culture. Rapid tests had a sensitivity of 0.896 compared to cultures, a specificity of 0.769, a PPV of 0.763, and a NPV of 0.899. The rapid test was found to be less sensitive in throat samples (0.81) than in nose or inguinal samples (0.93 for both). In 32/192 (16%) patients a positive rapid PCR result was not confirmed by culture, despite several subsequent screening samples in some patients. Cycle threshold (Ct) for SCCmec of these PCR positive reactions were all >30. Conclusions: GeneXpert MRSA was found to be suitable for the rapid detection in nose, inguinal, and throat samples, however with a lower sensitivity in the later. Negative cultures in 16% of our PCR-positive patients raised the question of false positivity or higher sensitivity of GeneXpert. Further work is needed to investigate these cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to standardise an in-house real-time polymerase chain reaction (rtPCR) to allow quantification of hepatitis B virus (HBV) DNA in serum or plasma samples, and to compare this method with two commercial assays, the Cobas Amplicor HBV monitor and the Cobas AmpliPrep/Cobas TaqMan HBV test. Samples from 397 patients from the state of São Paulo were analysed by all three methods. Fifty-two samples were from patients who were human immunodeficiency virus and hepatitis C virus positive, but HBV negative. Genotypes were characterised, and the viral load was measure in each sample. The in-house rtPCR showed an excellent success rate compared with commercial tests; inter-assay and intra-assay coefficients correlated with commercial tests (r = 0.96 and r = 0.913, p < 0.001) and the in-house test showed no genotype-dependent differences in detection and quantification rates. The in-house assay tested in this study could be used for screening and quantifying HBV DNA in order to monitor patients during therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Brazil, human and canine visceral leishmaniasis (CVL) caused byLeishmania infantum has undergone urbanisation since 1980, constituting a public health problem, and serological tests are tools of choice for identifying infected dogs. Until recently, the Brazilian zoonoses control program recommended enzyme-linked immunosorbent assays (ELISA) and indirect immunofluorescence assays (IFA) as the screening and confirmatory methods, respectively, for the detection of canine infection. The purpose of this study was to estimate the accuracy of ELISA and IFA in parallel or serial combinations. The reference standard comprised the results of direct visualisation of parasites in histological sections, immunohistochemical test, or isolation of the parasite in culture. Samples from 98 cases and 1,327 noncases were included. Individually, both tests presented sensitivity of 91.8% and 90.8%, and specificity of 83.4 and 53.4%, for the ELISA and IFA, respectively. When tests were used in parallel combination, sensitivity attained 99.2%, while specificity dropped to 44.8%. When used in serial combination (ELISA followed by IFA), decreased sensitivity (83.3%) and increased specificity (92.5%) were observed. Serial testing approach improved specificity with moderate loss in sensitivity. This strategy could partially fulfill the needs of public health and dog owners for a more accurate diagnosis of CVL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The role of lysophosphatidic acid (LPA) in the control of emotional behavior remains to be determined. We analyzed the effects of the central administration of 1-oleoyl-LPA (LPA 18∶1) in rats tested for food consumption and anxiety-like and depression-like behaviors. For this purpose, the elevated plus-maze, open field, Y maze, forced swimming and food intake tests were performed. In addition, c-Fos expression in the dorsal periaqueductal gray matter (DPAG) was also determined. The results revealed that the administration of LPA 18∶1 reduced the time in the open arms of the elevated plus-maze and induced hypolocomotion in the open field, suggesting an anxiogenic-like phenotype. Interestingly, these effects were present following LPA 18∶1 infusion under conditions of novelty but not under habituation conditions. In the forced swimming test, the administration of LPA 18∶1 dose-dependently increased depression-like behavior, as evaluated according to immobility time. LPA treatment induced no effects on feeding. However, the immunohistochemical analysis revealed that LPA 18∶1 increased c-Fos expression in the DPAG. The abundant expression of the LPA1 receptor, one of the main targets for LPA 18∶1, was detected in this brain area, which participates in the control of emotional behavior, using immunocytochemistry. These findings indicate that LPA is a relevant transmitter potentially involved in normal and pathological emotional responses, including anxiety and depression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Fragile X syndrome (FXS) is an inherited neurodevelopmental condition characterised by behavioural, learning disabilities, physical and neurological symptoms. In addition, an important degree of comorbidity with autism is also present. Considered a rare disorder affecting both genders, it first becomes apparent during childhood with displays of language delay and behavioural symptoms.Main aim: To show whether the combination of 10 mg/kg/day of ascorbic acid (vitamin C) and 10 mg/kg/day of α-tocopherol (vitamin E) reduces FXS symptoms among male patients ages 6 to 18 years compared to placebo treatment, as measured on the standardized rating scales at baseline, and after 12 and 24 weeks of treatment.Secondary aims: To assess the safety of the treatment. To describe behavioural and cognitive changes revealed by the Developmental Behaviour Checklist Short Form (DBC-P24) and the Wechsler Intelligence Scale for Children-Revised. To describe metabolic changes revealed by blood analysis. To measure treatment impact at home and in an academic environment. METHODS/DESIGN A phase II randomized, double-blind pilot clinical trial. SCOPE male children and adolescents diagnosed with FXS, in accordance with a standardized molecular biology test, who met all the inclusion criteria and none of the exclusion criteria. INSTRUMENTATION clinical data, blood analysis, Wechsler Intelligence Scale for Children-Revised, Conners parent and teacher rating scale scores and the DBC-P24 results will be obtained at the baseline (t0). Follow up examinations will take place at 12 weeks (t1) and 24 weeks (t2) of treatment. DISCUSSION A limited number of clinical trials have been carried out on children with FXS, but more are necessary as current treatment possibilities are insufficient and often provoke side effects. In the present study, we sought to overcome possible methodological problems by conducting a phase II pilot study in order to calculate the relevant statistical parameters and determine the safety of the proposed treatment. The results will provide evidence to improve hyperactivity control and reduce behavioural and learning problems using ascorbic acid (vitamin C) and α-tocopherol (vitamin E). The study protocol was approved by the Regional Government Committee for Clinical Trials in Andalusia and the Spanish agency for drugs and health products. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT01329770 (29 March 2011).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: An accurate, noninvasive technique for the diagnosis of coronary disease would be an important advance. We investigated the accuracy of coronary magnetic resonance angiography among patients with suspected coronary disease in a prospective, multicenter study. METHODS: Coronary magnetic resonance angiography was performed during free breathing in 109 patients before elective x-ray coronary angiography, and the results of the two diagnostic procedures were compared. RESULTS: A total of 636 of 759 proximal and middle segments of coronary arteries (84 percent) were interpretable on magnetic resonance angiography. In these segments, 78 (83 percent) of 94 clinically significant lesions (those with a > or = 50 percent reduction in diameter on x-ray angiography) were also detected by magnetic resonance angiography. Overall, coronary magnetic resonance angiography had an accuracy of 72 percent (95 percent confidence interval, 63 to 81 percent) in diagnosing coronary artery disease. The sensitivity, specificity, and accuracy for patients with disease of the left main coronary artery or three-vessel disease were 100 percent (95 percent confidence interval, 97 to 100 percent), 85 percent (95 percent confidence interval, 78 to 92 percent), and 87 percent (95 percent confidence interval, 81 to 93 percent), respectively. The negative predictive values for any coronary artery disease and for left main artery or three-vessel disease were 81 percent (95 percent confidence interval, 73 to 89 percent) and 100 percent (95 percent confidence interval, 97 to 100 percent), respectively. CONCLUSIONS: Among patients referred for their first x-ray coronary angiogram, three-dimensional coronary magnetic resonance angiography allows for the accurate detection of coronary artery disease of the proximal and middle segments. This noninvasive approach reliably identifies (or rules out) left main coronary artery or three-vessel disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The glycosylated hemoglobin (HbA1c) is used to help monitor the degree of a diabetic’s hyperglycemia. Security and accuracy of the methods used in its detection are affected by variants forms of Hb or elevations in levels of Fetal Hb (HbF). These interference are the result of a change in the haemoglobin total net charge of the variant due of a substitution of one amino acid in the remaining amino terminal of the beta chain. International Standardization for HbA1c values (NGSP) not include interference assessment as part of the certification program. Therefore, the effect of each variant or the lifting of the HbF on HbA1c result should be examined in each sample depending on the detected variant and the method used for the detection of the same. The objectives were: to describe the possible variants of Hb and their interference in HbA1c measurement by our method, after the implementation of a computer program for their detection. To identify some variants detected by chromatography liquid ion exchange high resolution (HPLC) with DNA molecular sequencing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A methotrexate-containing medium for the detection of beta-hemolytic group B streptococci from clinical specimens on the basis of detection of pigment is described. The medium contained peptone, starch, serum, MgSO4, glucose, pyruvate, methotrexate (as pigment enhancer), phosphate-morpholine-propanesulfonic acid buffer, and selective agents. The recovery of beta-hemolytic group B streptococci was comparable to that obtained with selective broth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: We evaluated the prenatal detection of gastrointestinal obstruction (GIO, including atresia, stenosis, absence or fistula) by routine ultrasonographic examination in an unselected population all over Europe. METHODS: Data from 18 congenital malformation registries in 11 European countries were analysed. These multisource registries used the same methodology. All fetuses/neonates with GIO confirmed within 1 week after birth who had prenatal sonography and were born during the study period (1 July 1996 to 31 December 1998) were included. RESULTS: There were 670 793 births in the area covered and 349 fetuses/neonates had GIO. The prenatal detection rate of GIO was 34%; of these 40% were detected < or = 24 weeks of gestation (WG). A total of 31% (60/192) of the isolated GIO were detected prenatally, as were 38% (59/157) of the associated GIO (p=0.26). The detection rate was 25% for esophageal obstruction (31/122), 52% for duodenal obstruction (33/64), 40% for small intestine obstruction (27/68) and 29% for large intestine obstruction (28/95) (p=0.002). The detection rate was higher in countries with a policy of routine obstetric ultrasound. Fifteen percent of pregnancies were terminated (51/349). Eleven of these had chromosomal anomalies, 31 multiple malformations, eight non-chromosomal recognized syndromes, and one isolated GIO. The participating registries reflect the various national policies for termination of pregnancy (TOP), but TOPs after 24 WG (11/51) do not appear to be performed more frequently in countries with a liberal TOP policy. CONCLUSION: This European study shows that the detection rate of GIO depends on the screening policy and on the sonographic detectability of GIO subgroups.