923 resultados para Metallic-dye Nanocluster
Resumo:
Working with low voltage microscope (R.C.A., EMC-2, of 30KV.) the authors verified that parlodion and Formvar films are quickly destroyed by intense heating under the electron beam. They have tried to employ oxide films, as Al2O3 and SiO, more resistant to heat. Al2O3 films are prepared by anodic oxidation of thin aluminium sheets, under 8 to 10 volts in a 3% ammonium citrate solution and subsequent aluminium dissolution in a O.25% HgCl2 solution. These films are very suitable when prepared with highly pure aluminium of extremely homogeneous surface. Best results were obtained with SiO films, evaporated in high vacuum over Parlodion films mounted on metallic grids. Employing 1 or 1.5 mg of SiOm highly homogeneous and resistant films are obtained, having little inferior transparence than the Parlodion ones. Pure SiO films (1.5 mg) are obtained by elimination of the Parlodion under slow heating until 250°C; they are greatly transparent but little resistant to water, thus beeing indicated in dry preparations. For particles which deposite in a chain-like form around thin fibers, the authors employ the mounting on Parlodion fibers, obtained by heating Parlodion films on microscope grids about 190°C.
Resumo:
Estudio elaborado a partir de una estancia en la Universidad de Rochester, Estados Unidos, de octubre del 2006 a enero del 2007. La estancia realizada en la Universidad de Rochester estuvo orientada al aprendizaje en profundidad del oftalmoscopio láser de barrido. El oftalmoscopio láser de barrido emplea una técnica confocal con la finalidad de visualizar diferentes estructuras retinianas en seres vivos. El instrumento diseñado y desarrollado en el Centro de Ciencias de la Visión incorpora un sistema de óptica adaptativa y fluorescencia. La óptica adaptativa aplicada en este oftalmoscopio tiene como objetivo corregir las aberraciones existentes en el ojo y así permitir observar detalles de la retina que de otra forma se verían emborronados. De esta forma se consigue alcanzar valores de resolución muy cercanos a los impuestos por difracción. Por otro lado el uso de fluorescencia tiene por objetivo el permitir la visualización de células y estructuras que, de no ser teñidas, son transparentes a la luz y visible. Esta técnica se ha estado utilizando principalmente en primates y ratas, aunque actualmente también se están llevando a cabo medidas de células de epitelio pigmentario en seres humanos ya que el pigmento contenido en estas células permite la aplicación de la fluorescencia sin necesidad de utilizar tinción.
Resumo:
Raman spectroscopy has been applied to characterize fiber dyes and determine the discriminating ability of the method. Black, blue, and red acrylic, cotton, and wool samples were analyzed. Four excitation sources were used to obtain complementary responses in the case of fluorescent samples. Fibers that did not provide informative spectra using a given laser were usually detected using another wavelength. For any colored acrylic, the 633-nm laser did not provide Raman information. The 514-nm laser provided the highest discrimination for blue and black cotton, but half of the blue cottons produced noninformative spectra. The 830-nm laser exhibited the highest discrimination for red cotton. Both visible lasers provided the highest discrimination for black and blue wool, and NIR lasers produced remarkable separation for red and black wool. This study shows that the discriminating ability of Raman spectroscopy depends on the fiber type, color, and the laser wavelength.
Resumo:
Pizgrischite, (Cu,Fe)Cu14PbBi17S35, is a new mineral species named after the type locality, Piz Grisch Mountain, Val Ferrera, Graubunden, Switzerland. This sulfosalt occurs as thin, striated, metallic lead-grey blades measuring up to I cm in length, embedded in quartz and associated with tetrahedrite, chalcopyrite, pyrite, sphalerite, emplectite and derivatives of the aikinite-bismuthinite series. In plane-polarized light, the new species is brownish grey with no perceptible pleochroism; under crossed nicols in oil immersion, it presents a weak anisotropy with dark brown tints. Minimum and maximum reflectance values (in %) in air are: 40.7-42.15 (470 nm), 41.2-43.1 (546 nm), 41.2-43.35 (589 nm) and 40.7-43.3 (650 nm). Cleavage is perfect along 001 I and well developed on {010}. Abundant polysynthetic twinning is observed on (010). The mean micro-indentation hardness is 190 kg/mm(2) (Mohs hardness 3.3), and the calculated density is 6.58 g/cm(3). Electron-microprobe analyses yield (wt%; mean result of seven analyses): Cu 16.48, Pb 2.10, Fe 0.77, Bi 60.70, Sb 0.35, S 19.16, Se 0.04, total 99.60. The resulting empirical chemical formula is (Cu15.24Fe0.80Pb0.60)(Sigma 16.64)(Bi17.07Sb0.17)(Sigma 17.24)(S35.09Se0.03)(Sigma 35.12), in accordance with the formula derived from the single-crystal refinement of the structure, (Cu,Fe)Cu14PbBi17S35. Pizgrischite is monoclinic, space group C2/m, with the following unit-cell parameters: a 35.054(2), b3.91123(I), c43.192(2) angstrom, beta 96.713(4)degrees, V5881.24 angstrom(3), Z=4. The strongest seven X-ray powder-diffraction lines [d in angstrom (I)(hkl)] are: 5.364(40)((6) over bar 04), 4.080(50)((8) over bar 05), 3.120(40)(118), 3.104(68)((3) over bar 18), 2.759(53) ((9) over bar 11),2.752(44)(910) and 1.956(100)(020). The crystal structure is an expanded monoclinic derivative of kupcikite. Pizgrischite belongs to the cuprobismutite series of bismuth sulfosalts but, sensu stricto, it is not a homologue of cuprobismutite. At the type locality. pizarischite is the result of the Alpine metamorphism under greenschist-facies conditions of pre-Tertiary hydrothermal Cu-Bi mineralization.
Resumo:
A generic optical biosensing strategy was developed that relies on the absorbance enhancement phenomenon occurring in a multiple scattering matrix. Experimentally, inserts made of glass fiber membrane were placed into microplate wells in order to significantly lengthen the trajectory of the incident light through the sample and therefore increase the corresponding absorbance. Enhancement factor was calculated by comparing the absorbance values measured for a given amount of dye with and without the absorbance-enhancing inserts in the wells. Moreover, the dilution of dye in solutions with different refractive indices (RI) clearly revealed that the enhancement factor increased with the ΔRI between the membrane and the surrounding medium, reaching a maximum value (EF>25) when the membranes were dried. On this basis, two H2O2-biosensing systems were developed based on the biofunctionalization of the glass fiber inserts either with cytochrome c or horseradish peroxidase (HRP) and the analytical performances were systematically compared with the corresponding bioassay in solution. The efficiency of the absorbance-enhancement approach was particularly clear in the case of the cytochrome c-based biosensor with a sensitivity gain of 40 folds and wider dynamic range. Therefore, the developed strategy represents a promising way to convert standard colorimetric bioassays into optical biosensors with improved sensitivity.
Resumo:
AIM: To confirm the accuracy of sentinel node biopsy (SNB) procedure and its morbidity, and to investigate predictive factors for SN status and prognostic factors for disease-free survival (DFS) and disease-specific survival (DSS). MATERIALS AND METHODS: Between October 1997 and December 2004, 327 consecutive patients in one centre with clinically node-negative primary skin melanoma underwent an SNB by the triple technique, i.e. lymphoscintigraphy, blue-dye and gamma-probe. Multivariate logistic regression analyses as well as the Kaplan-Meier were performed. RESULTS: Twenty-three percent of the patients had at least one metastatic SN, which was significantly associated with Breslow thickness (p<0.001). The success rate of SNB was 99.1% and its morbidity was 7.6%. With a median follow-up of 33 months, the 5-year DFS/DSS were 43%/49% for patients with positive SN and 83.5%/87.4% for patients with negative SN, respectively. The false-negative rate of SNB was 8.6% and sensitivity 91.4%. On multivariate analysis, DFS was significantly worsened by Breslow thickness (RR=5.6, p<0.001), positive SN (RR=5.0, p<0.001) and male sex (RR=2.9, p=0.001). The presence of a metastatic SN (RR=8.4, p<0.001), male sex (RR=6.1, p<0.001), Breslow thickness (RR=3.2, p=0.013) and ulceration (RR=2.6, p=0.015) were significantly associated with a poorer DSS. CONCLUSION: SNB is a reliable procedure with high sensitivity (91.4%) and low morbidity. Breslow thickness was the only statistically significant parameter predictive of SN status. DFS was worsened in decreasing order by Breslow thickness, metastatic SN and male gender. Similarly DSS was significantly worsened by a metastatic SN, male gender, Breslow thickness and ulceration. These data reinforce the SN status as a powerful staging procedure
Resumo:
The level of information provided by ink evidence to the criminal and civil justice system is limited. The limitations arise from the weakness of the interpretative framework currently used, as proposed in the ASTM 1422-05 and 1789-04 on ink analysis. It is proposed to use the likelihood ratio from the Bayes theorem to interpret ink evidence. Unfortunately, when considering the analytical practices, as defined in the ASTM standards on ink analysis, it appears that current ink analytical practices do not allow for the level of reproducibility and accuracy required by a probabilistic framework. Such framework relies on the evaluation of the statistics of the ink characteristics using an ink reference database and the objective measurement of similarities between ink samples. A complete research programme was designed to (a) develop a standard methodology for analysing ink samples in a more reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in a forensic context. This report focuses on the first of the three stages. A calibration process, based on a standard dye ladder, is proposed to improve the reproducibility of ink analysis by HPTLC, when these inks are analysed at different times and/or by different examiners. The impact of this process on the variability between the repetitive analyses of ink samples in various conditions is studied. The results show significant improvements in the reproducibility of ink analysis compared to traditional calibration methods.