998 resultados para Mesh size


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An understanding of seed germination ecology of weeds can assist in predicting their potential distribution and developing effective management strategies. Influence of environmental factors and seed size on germination and seedling emergence of Convolvulus arvensis (field bindweed) was studied in laboratory and greenhouse conditions. Germination occurred over a wide range of constant temperatures, between 15 and 40 ºC, with optimum germination between 20 and 25 ºC. Time to start germination, time to 50% germination and mean germination time increased while germination percentage and germination index decreased with an increase in temperature from 20 ºC, salinity and osmotic stress. However, germination was tolerant to low salt (25 mM) or osmotic stress (0.2 MPa), but as salinity and osmotic stress increased, germination percentage and germination index decreased. Seeds of C. arvensis placed at soil surface showed maximum emergence and decreased as seeding depth increased. Seeds of C. arvensis germinated over a wide range of pH (4 to 9) but optimum germination occurred at pH 6 to 8. Under highly alkaline and acidic pH, time to start germination, time to 50% germination and mean germination time increased while germination percentage and germination index decreased. Increase in field capacity caused decreased time to start germination, time to 50% germination and mean germination time but increased germination percentage and germination index. Bigger seeds had low time to start germination, time to 50% germination and mean germination time but high germination percentage and germination index. Smaller seeds were more sensitive to environmental factors as compared to larger or medium seeds. It can be concluded that except for pH, all environmental factors and seed sizes adversely affect C. arvensis as regards seed germination or emergence and germination or emergence traits, and larger seeds result in improved stand establishment and faster germination than small seeds, regardless of moisture stress or deeper seeding depth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to evaluate baby corn yield, green corn yield, and grain yield in corn cultivar BM 3061, with weed control achieved via a combination of hoeing and intercropping with gliricidia, and determine how sample size influences weed growth evaluation accuracy. A randomized block design with ten replicates was used. The cultivar was submitted to the following treatments: A = hoeings at 20 and 40 days after corn sowing (DACS), B = hoeing at 20 DACS + gliricidia sowing after hoeing, C = gliricidia sowing together with corn sowing + hoeing at 40 DACS, D = gliricidia sowing together with corn sowing, and E = no hoeing. Gliricidia was sown at a density of 30 viable seeds m-2. After harvesting the mature ears, the area of each plot was divided into eight sampling units measuring 1.2 m² each to evaluate weed growth (above-ground dry biomass). Treatment A provided the highest baby corn, green corn, and grain yields. Treatment B did not differ from treatment A with respect to the yield values for the three products, and was equivalent to treatment C for green corn yield, but was superior to C with regard to baby corn weight and grain yield. Treatments D and E provided similar yields and were inferior to the other treatments. Therefore, treatment B is a promising one. The relation between coefficient of experimental variation (CV) and sample size (S) to evaluate growth of the above-ground part of the weeds was given by the equation CV = 37.57 S-0.15, i.e., CV decreased as S increased. The optimal sample size indicated by this equation was 4.3 m².

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variations in egg length were observed for two populations of cryptic species of Anastrepha fraterculus (Wiedemann). The eggs of type I flies were smaller than those of type II individuals. For both types, in regard to yolk mass extrusion, four classes of embryos were detected. Class 1: embryos that extrude masses at both extremities; class 2: embryos in which extrusion occurs only at the anterior pole; class 3: embryos that eliminate mass only at the posterior pole, and class 4: embryos that do not extrude any mass. Embryo class frequencies were similar for populations belonging to the same type, but different between types. Individual females may produce eggs from different embryo classes, but for any given female the pattern remains constant during a long period of oviposition. Variation in size of the extruded masses was similar for both populations. Individual females produced embryos with a small range of mass diameters, and different females produced masses of different mean size. However, individual mass size remained constant during oviposition. The results suggest the existence of genetic components involved in the control of this unusual process. Larvae of both types presented, just before eclosion, similar unusual behaviors: they ingest the anterior extruded mass, rotate 180°, absorb the posterior mass and eclose near the posterior pole. Data show that cryptic A. fraterculus type I and type II differs in regard to egg size as well as to the phenomenon of yolk mass extrusion

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although gap junction channels are still widely viewed as large, non-specific pores connecting cells, the diversity in the connexin family has led more attention to be focused on their permeability characteristics. We summarize here the current status of these investigations, both published and on-going, that reveal both charge and size selectivity between gap junction channels composed of different connexins. In particular, this review will focus on quantitative approaches that monitor the expression level of the connexins, so that it is clear that differences that are seen can be attributed to channel properties. The degree of selectivity that is observed is modest compared to other channels, but is likely to be significant for biological molecules that are labile within the cell. Of particular relevance to the in vivo function of gap junctions, recent studies are summarized that demonstrate that the connexin phenotype can control the nature of the endogenous traffic between cells, with consequent effects on biological effects of gap junctions such as tumor suppression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the equivalent light hypothesis, molecular defects in the photoreceptor lead to a continuous activation of the photoreceptor cascade in a manner equivalent to real light. The consequences in diseases such as retinitis pigmentosa (RP) are as disruptive to the cells as real light. Two forms of the equivalent light hypothesis can be distinguished: strong - mutations in rhodopsin or other cascade proteins in some forms of RP continuously excite the visual phototransduction cascade; weak - disruption of outer segments in all patients with RP eliminates circulating dark current and blocks neurotransmitter release in a manner similar to real light. Both forms of the equivalent light hypothesis predict that pupils of patients with RP will be constricted like those of normal subjects in the light. The purpose of this study was to test the equivalent light hypothesis by determining whether steady-state pupil diameter following full dark adaptation is abnormally small in any of a sample of patients with RP. Thirty-five patients with RP and 15 normal subjects were tested. Direct steady-state pupillometric measures were obtained from one eye in a full-field dome after 45 min of dark adaptation by videotaping the pupil with an infrared camera. Mean pupil diameter in the dark was comparable (t = -0.15, P = 0.88) between patients with RP (6.85 ± 0.58 mm) and normal subjects (6.82 ± 0.76 mm). The results of the present study are clearly counter to the prediction of the second (weaker) form of the equivalent light hypothesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An alternative device for the immobilization of the hind limb of the rat was developed to study the effects of chronic disuse on the soleus and tibialis anterior muscles, maintained for 3 weeks in the shortening and the stretching positions, respectively. The proposed device is made of steel mesh and cotton materials, and has some advantages when compared to cast or plaster cast: it is cheaper, lighter (12 g or 4% of the body weight of the rat) and the same unit can be easily adjusted and used several times in the same animal or in animals of similar size. Immobilization is also useful to restrain the movements of the hip, knee, and ankle joints. Male rats (291 ± 35 g and aged 14 ± 2 weeks) were used to develop and test the model. The soleus muscle of 18 rats was maintained in a shortened position for 21 consecutive days and lost 19 ± 7% of its length (P = 0.008) and 44 ± 6% of its weight (P = 0.002) compared to the contralateral intact muscle. No difference (P = 0.67) was found in the stretched tibialis anterior of the same hind limb when compared to the contralateral muscle. No ulcer, sore or foot swelling was observed in the animals. Immobilization was effective in producing chronic muscle disuse in the hind limbs of rats and is an acceptable alternative to the traditional methods of immobilization such as cast or plaster cast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Panic disorder is thought to involve dysfunction in the septohippocampal system, and the presence of a cavum septum pellucidum might indicate the aberrant development of this system. We compared the prevalence and size of cavum septum pellucidum in 21 patients with panic disorder and in 21 healthy controls by magnetic resonance imaging. The length of the cavum septum pellucidum was measured by counting the number of consecutive 1-mm coronal slices in which it appeared. A cavum septum pellucidum of >6 mm in length was rated as large. There was no significant difference in the proportion of patients (16 of 21 or 76.2%) and controls (18 of 21 or 85.7%) with a cavum septum pellucidum (P = 0.35, Fisher's exact test, one-tailed), and no members of either group had a large cavum septum pellucidum. The mean cavum septum pellucidum rating in the patient and control groups was 1.81 (SD = 1.50) and 2.09 (SD = 1.51), respectively. There were also no significant differences between groups when we analyzed cavum septum pellucidum ratings as a continuous variable (U = 196.5; P = 0.54). Across all subjects there was a trend towards a higher prevalence of cavum septum pellucidum in males (100%, 10 of 10) than females (75%, 24 of 32; P = 0.09, Fisher's exact test, one-tailed). Thus, we conclude that, while panic disorder may involve septo-hippocampal dysfunction, it is not associated with an increased prevalence or size of the cavum septum pellucidum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pelvic floor disorders, such as urinary incontinence (UI) and pelvic organ prolapse (POP), are common disorders in women. Because of the prolonged life expectancy the prevalence of UI and POP and the probability of ending up in surgery are increasing. However, the pathophysiology behind these disorders is still unsolved. The aim of this thesis is to study possible alterations in the connective tissue in the vaginal wall in patients with and without POP. The long-term outcome and complications of mid-urethral slings (MUS) and mesh-augmented POP surgery were studied in heterogenic patient populations. More elastin and a slight increase in immunostaining of type III and V collagens in tissue samples were obtained from patients with POP compared to controls in whom type I collagen was more prominent. The studies assessing the mesh-augmented procedures revealed good efficacy and high patient satisfaction after a long-term follow-up. Patients operated on because of mixed incontinence and with BMI >30 kg/m² reported significantly more urinary symptoms and a lower quality of life than the patients operated on because of stress urinary incontinence and the ones with BMI ≤30 kg/m². The objective outcome was equal between the groups. Mesh exposure through vaginal mucosa occurred in 23 % of the patients after POP surgery, most of these being asymptomatic. There are alterations in connective tissues in patients with POP. Mid-urethral sling procedures produced good long-term cure rates and patient satisfaction. As to the prolapse surgery, in spite of relatively high exposure rate, mesh-augmented procedure proved to be safe and effective method for the correction of POP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Size changes in muscle fibers of subjects with chronic heart disease (CHD) have been reported, although a consensus has not been achieved. The aims of the present study were to investigate a possible association between CHD and fiber size changes in the brachial biceps compared to subjects without heart disease. Forty-six muscle samples were obtained in autopsies of individuals (13 to 84 years) without neuromuscular disorders, 19 (10 males and 9 females) with, and 27 (14 males and 13 females) without CHD. In all cases muscle sections were stained with hematoxylin and eosin and processed for the visualization of myofibrillar ATPase activity. The lesser diameter of type 1 and type 2 fibers was obtained tracing their outlines (at least 150 fibers of each type per sample) onto an image analyzer connected to a computer. The results were analyzed statistically comparing males and females with and without CHD. Type 1 fiber mean lesser diameters were 51.51 and 54.52 µm in males (normal range 34-71 µm) and 45.65 and 55.42 µm in females (normal range 34-65 µm) without and with CHD, respectively; type 2 fibers measured 54.31, 58.23, 41.15, and 49.57 µm, respectively (normal range 36-79 µm for males and 32-59 µm for females). No significant difference in fiber size was detected in 24 males with and without CHD, while in 22 females there was a significant increase in size in those with cardiomyopathy. We concluded that CHD does not determine significant changes in fiber size. However, in females, there is some hypertrophy which, despite within normal range, may reflect morphologic heterogeneity of the sample, or the daily life activities in the upper limbs as a compensatory mechanism to fatigability that affect predominantly the lower limbs in subjects with CHD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nine lead electrocardiograms of non-infarcted (N = 61) and infarcted (N = 71) female Wistar rats (200-250 g) were analyzed in order to distinguish left ventricle myocardial infarction (MI) larger than 40% (LMI) from MI smaller than 40% (SMI). MI larger than 40% clearly caused a deviation of ÂQRS and ÂT from normal values of 270-360 degrees to 90-270 degrees. Infarcted rats showed Q wave in D1 larger than 1 mm with 94% sensitivity and 100% specificity. The sum of QRS positivity in V1, V2 and V6 lower than 10 mm identified MI with 82% sensitivity and 100% specificity. The data showed that MI can be easily and reliably diagnosed by electrocardiogram in the rat. However, contradicting what is frequently believed, when specificity and sensitivity were analyzed focusing on MI size, none of these current electrocardiographic indices of MI size adequately discriminates LMI from SMI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pressure-induced dissociation of a turbid solution of casein micelles was studied in situ in static and dynamic light scattering experiments. We show that at high pressure casein micelles decompose into small fragments comparable in size to casein monomers. At intermediate pressure we observe particles measuring 15 to 20 nm in diameter. The stability against pressure dissociation increased with temperature, suggesting enhanced hydrophobic contacts. The pressure transition curves are biphasic, compatible with a temperature (but not pressure)-dependent conformational equilibrium of two micelle species. Our thermodynamic model predicts an increase in structural entropy with temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although echocardiography has been used in rats, few studies have determined its efficacy for estimating myocardial infarct size. Our objective was to estimate the myocardial infarct size, and to evaluate anatomic and functional variables of the left ventricle. Myocardial infarction was produced in 43 female Wistar rats by ligature of the left coronary artery. Echocardiography was performed 5 weeks later to measure left ventricular diameter and transverse area (mean of 3 transverse planes), infarct size (percentage of the arc with infarct on 3 transverse planes), systolic function by the change in fractional area, and diastolic function by mitral inflow parameters. The histologic measurement of myocardial infarction size was similar to the echocardiographic method. Myocardial infarct size ranged from 4.8 to 66.6% when determined by histology and from 5 to 69.8% when determined by echocardiography, with good correlation (r = 0.88; P < 0.05; Pearson correlation coefficient). Left ventricular diameter and mean diastolic transverse area correlated with myocardial infarct size by histology (r = 0.57 and r = 0.78; P < 0.0005). The fractional area change ranged from 28.5 ± 5.6 (large-size myocardial infarction) to 53.1 ± 1.5% (control) and correlated with myocardial infarct size by echocardiography (r = -0.87; P < 0.00001) and histology (r = -0.78; P < 00001). The E/A wave ratio of mitral inflow velocity for animals with large-size myocardial infarction (5.6 ± 2.7) was significantly higher than for all others (control: 1.9 ± 0.1; small-size myocardial infarction: 1.9 ± 0.4; moderate-size myocardial infarction: 2.8 ± 2.3). There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Triphenyltetrazolium chloride (TTC) staining and echocardiography (ECHO) are methods used to determine experimental myocardial infarction (MI) size, whose practical applicability should be expanded. Our objectives were to analyze the accuracy of ECHO in determining infarction size in rats during the first days following coronary occlusion and to test whether a simplified single measurement by TTC correctly indicates MI size, as determined by the average value for multiple slices. Infarction was induced in female Wistar rats by coronary artery occlusion and MI size analysis was performed after the acute (7th day) and chronic periods (after 4 weeks) by ECHO matched with TTC. ECHO and TTC showed similar values of MI size (% of left ventricle perimeter) in acute (ECHO: 33 ± 11, TTC: 35 ± 14) and chronic (ECHO: 38 ± 14, TTC: 39 ± 13 periods), and also presented an excellent correlation (r = 0.92, P < 0.001). Although measurements from different heart planes showed discrepancies, a single measurement acquired from the mid-ventricular level by TTC was a good estimate of MI size calculated by the average of multiple planes, with minimal disagreement (Bland-Altman test with mean ratio bias of 0.99 ± 0.07) and close to an ideal correlation (r = 0.99, P < 0.001). In the present study, ECHO was confirmed as a useful method for the determination of MI size even in the acute phase. Also, the single measure of a mid-ventricular section proposed as a simplification of the TTC method is a satisfactory prediction of average MI extension.