967 resultados para MR tagging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Signatur des Originals: S 36/G01580

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Signatur des Originals: S 36/G02589

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Signatur des Originals: S 36/G02880

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Signatur des Originals: S 36/G04056

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Signatur des Originals: S 36/G04152

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Investigations into the shortcomings of current intracavitary brachytherapy (ICBT) technology has lead us to design an Anatomically Adaptive Applicator (A3). The goal of this work was to design and characterize the imaging and dosimetric capabilities of this device. The A3 design incorporates a single shield that can both rotate and translate within the colpostat. We hypothesized that this feature, coupled with specific A3 component construction materials and imaging techniques, would facilitate artifact-free CT and MR image acquisition. In addition, by shaping the delivered dose distribution via the A3 movable shield, dose delivered to the rectum will be less compared to equivalent treatments utilizing current state-of-the-art ICBT applicators. ^ Method and materials. A method was developed to facilitate an artifact-free CT imaging protocol that used a "step-and-shoot" technique: pausing the scanner midway through the scan and moving the A 3 shield out of the path of the beam. The A3 CT imaging capabilities were demonstrated acquiring images of a phantom that positioned the A3 and FW applicators in a clinically-applicable geometry. Artifact-free MRI imaging was achieved by utilizing MRI-compatible ovoid components and pulse-sequences that minimize susceptibility artifacts. Artifacts were qualitatively compared, in a clinical setup. For the dosimetric study, Monte-Carlo (MC) models of the A3 and FW (shielded and unshielded) applicators were validated. These models were incorporated into a MC model of one cervical cancer patient ICBT insertion, using 192Ir (mHDR v2 source). The A3 shield's rotation and translation was adjusted for each dwell position to minimize dose to the rectum. Superposition of dose to rectum for all A3 dwell sources (4 per ovoid) was applied to obtain a comparison of equivalent FW treatments. Rectal dose-volume histograms (absolute and HDR/PDR biologically effective dose (BED)) and BED to 2 cc (BED2cc ) were determined for all applicators and compared. ^ Results. Using a "step-and-shoot" CT scanning method and MR compliant materials and optimized pulse-sequences, images of the A 3 were nearly artifact-free for both modalities. The A3 reduced BED2cc by 18.5% and 7.2% for a PDR treatment and 22.4% and 8.7% for a HDR treatment compared to treatments delivered using an uFW and sFW applicator, respectively. ^ Conclusions. The novel design of the A3 facilitated nearly artifact-free image quality for both CT and MR clinical imaging protocols. The design also facilitated a reduction in BED to the rectum compared to equivalent ICBT treatments delivered using current, state-of-the-art applicators. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Working with subsistence whale hunters, we tagged 19 mostly immature bowhead whales (Balaena mysticetus) with satellite-linked transmitters between May 2006 and September 2008 and documented their movements in the Chukchi Sea from late August through December. From Point Barrow, Alaska, most whales moved west through the Chukchi Sea between 71° and 74° N latitude; nine whales crossed in six to nine days. Three whales returned to Point Barrow for 13 to 33 days, two after traveling 300 km west and one after traveling ~725 km west to Wrangel Island, Russia; two then crossed the Chukchi Sea again while the other was the only whale to travel south along the Alaskan side of the Chukchi Sea. Seven whales spent from one to 21 days near Wrangel Island before moving south to northern Chukotka. Whales spent an average of 59 days following the Chukotka coast southeastward. Kernel density analysis identified Point Barrow, Wrangel Island, and the northern coast of Chukotka as areas of greater use by bowhead whales that might be important for feeding. All whales traveled through a potential petroleum development area at least once. Most whales crossed the development area in less than a week; however, one whale remained there for 30 days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Barents cod spawn in the Motovsky Bay during the periods of warming in the Arctic when proportion of mature fish in the population is high enough. Cod spawning is most likely to occur in the Motovsky Bay when large cod forage in southeastern waters, and prespawning fish migrate close by the Murmansk coast. Under such conditions cod spawn in the Motovsky Bay, but low water temperature and slow egg drift toward Murmansk coastal waters delay development of cod eggs. As a result the eggs remain at the first stage for a long time; this causes high egg mortality before hatching. Larvae that survive and become pelagic and then bottom juveniles nevertheless have little chance to survive in winter because they are not biologically ready for overwintering. Thus, delay in egg development at the first stage delays subsequent stages of fish ontogeny, and strongly impairs survival of cod juveniles from the Motovsky Bay.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-invasive quantitative assessment of the right ventricular anatomical and functional parameters is a challenging task. We present a semi-automatic approach for right ventricle (RV) segmentation from 4D MR images in two variants, which differ in the amount of user interaction. The method consists of three main phases: First, foreground and background markers are generated from the user input. Next, an over-segmented region image is obtained applying a watershed transform. Finally, these regions are merged using 4D graph-cuts with an intensity based boundary term. For the first variant the user outlines the inside of the RV wall in a few end-diastole slices, for the second two marker pixels serve as starting point for a statistical atlas application. Results were obtained by blind evaluation on 16 testing 4D MR volumes. They prove our method to be robust against markers location and place it favourably in the ranks of existing approaches.