981 resultados para MICRO-CT SCAN
Resumo:
Our goal was to evaluate the diagnostic utility of C-reactive protein (CRP) alone or combined with clinical probability assessment in patients with suspected pulmonary embolism (PE), and to compare its performance to a D-dimer assay. We conducted a prospective study in which we performed a common immuno-turbidimetric CRP test and a rapid enzyme-linked immunosorbent assay (ELISA) D-dimer test in 259 consecutive outpatients with suspected PE at the emergency department of a teaching hospital. We assessed clinical probability of PE by a validated prediction rule overridden by clinical judgment. Patients with D-dimer levels > or = 500 microg/l underwent a work-up consisting of lower-limb venous ultrasound, spiral computerized tomography, ventilation-perfusion scan, or pulmonary angiography. Patients were followed up for three months. Seventy-seven (30%) of the patients had PE. The CRP alone had a sensitivity of 84% (95% confidence interval [CI).: 74 to 92%) and a negative predictive value (NPV) of 87% (95% CI: 78 to 93%) at a cutpoint of 5 mg/l. Overall, 61 (24%) patients with a low clinical probability of PE had a CRP < 5 mg/l. Due to the low prevalence of PE (9%) in this subgroup, the NPV increased to 97% (95% CI: 89 to 100%). The D-dimer (cutpoint 500 micro g/l) showed a sensitivity of 100% (95% CI: 95 to 100%) and a NPV of 100% (95% CI: 94 to 100%) irrespective of clinical probability and accurately rule out PE in 56 (22%) patients. Standard CRP tests alone or combined with clinical probability assessment cannot safely exclude PE.
Resumo:
Positron emission computed tomography (PET) is a functional, noninvasive method for imaging regional metabolic processes that is nowadays most often combined to morphological imaging with computed tomography (CT). Its use is based on the well-founded assumption that metabolic changes occur earlier in tumors than morphologic changes, adding another dimension to imaging. This article will review the established and investigational indications and radiopharmaceuticals for PET/CT imaging for prostate cancer, bladder cancer and testicular cancer, before presenting upcoming applications in radiation therapy.
Resumo:
Purpose: 1. To review Ct features suggestive of saprophytic aspergillosis (aspergilloma) and to correlate them with the final pathological results. 2. To illustrate the wide range of differential diagnosis. Methods and materials: The electronic database of our department from 1995 to 2007 revealed CT reports of 48 patients that had been considered very suggestive of aspergilloma. Two radiologists with 6 and 12 years experience in thoracic radiology jointly reviewed the corresponding CT features including ancillary findings and the underlying lung diseases and correlated them with the final pathological diagnosis. Results: Forty patients could be included in the study (12 women, mean age 52), while in 8 patients there was no adequate clinical follow-up. In 17 patients the diagnosis "mycetoma" due to aspergillus fumigatus infection was confirmed, either by surgery, biopsy or bronchoscopy. In 23 patients, differential diagnoses were found, such as cavitating bronchial carcinoma (n = 7), bacterial abscess (n = 3), typical (n = 2) and atypical (n = 2) tuberculosis, as well as inflammatory changes due to mucoviscidosis (n = 1), Wegener's disease (n = 1) or chronic obstructive pulmonary disease (n = 3). Fibromyxoide hamartoma, lung infarction and bronchomucocele were responsible for the typical CT feature in one patient each. Conclusion: 1. The typical CT feature suggesting mycetoma is softtissue proliferation within a pre-existing wall-thickened lung cavity, oten even considered "pathognomonic". However, this diagnosis was finally confirmed by surgery or laboratory findings in less than 50% of patients only. 2. Since differential diagnoses are very large, not only including cavitating lung cancer and tuberculosis, the individual underlying lung disease needs strongly being taken into account often giving the best clue for the correct diagnosis.
Resumo:
Messages à retenir: Le scanner peut aider au diagnostic et la caractérisation des valvulopathies et des lésions associées (aorte, coronaires). Le scanner est un examen incontournable pour l'évaluation pré-thérapeutique des procédures TAVI (transfémorale ou transapicale). Le scanner peut être utile pour caractériser les insuffisances aortiques. Grâce aux développements récents dans les thérapies peu invasives et au progrès du CT, le rôle du radiologue est redevenu central dans la prise en charge de certaines valvulopathies aortiques. Résumé: Les valvulopathies aortiques sont des maladies fréquentes. Leur exploration repose largement sur l'échocardiographie et sur l'IRM. Les progrès technologiques en scanner cardiaque ont permis à ce dernier d'explorer la valve aortique et ses pathologies. Ce cours est principalement consacré aux méthodes d'acquisition et de traitement des images dédiées à l'exploration de la valve aortique (plan de coupes, planimétrie, scores...). Une attention particulière est réservée aux considérations anatomiques spécifiques à celle-ci (variantes anatomiques). Les indications du scanner cardiaque dans les valvulopathies seront résumées (sténoses, insuffisances, pathologie tumorale et pathologies inflammatoires). Dans la sténose de la valve, outre ses performances diagnostiques, le scanner plus ou moins couplé à l'exploration des vaisseaux périphériques, est devenu une méthode intournable dans le bilan pré-thérapeutique. La connaissance des paramètres à évaluer (taille de l'anneau, position des coronaires, orientation du plan de la valve...) et la standardisation des mesures sont un élément clé pour une prise en charge optimale. Dans les insuffisances aortiques, les méthodes de quantification (planimétrie) peuvent être utilisées pour les caractériser avec des performances comparables à celles obtenues par d'autres techniques.
Resumo:
PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.
Resumo:
Les ordinateurs de poche ont le potentiel de devenir un outil de travail indispensable pour le médecin praticien. De part une facilité d'utilisation toujours plus grande, un format ultra-portable, une grande capacité de stockage de l'information et de synchronisation à de multiples bases de données, ils permettent l'accès en tout temps et littéralement au lit du malade à une gamme complète de ressources médicales. Cet article se veut une lllustration des différentes possibilités d'utilisation de ces nouveaux outils, au travers de situations cliniques banales rencontrées par tout praticien.
Resumo:
An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.
Resumo:
The MIT Scan T2 device has been implemented in Iowa as a new method for determining PCC pavement thickness compliance. The T2 device utilizes a magnetic pulse induction technology to measure the distance from a sensor to a metal target. The objective of this project was to conduct an interlaboratory study (ASTM C802) to determine the precision of the test.Fifteen MIT Scan T2 gauges and fifteen operators performed testing on three reference platforms and nine pavement locations of varying thicknesses. The testing was conducted on October 29, 2014 at two sites near Ames, Iowa. Usable data was obtained from every operator at all locations.
Resumo:
Les collectivités d'enfants, comme les écoles, mettent en contact de nombreuses personnes dans un espace restreint. Cette proximité peut favoriser la transmission croisée de micro-organismes infectieux. Les épidémies de varicelle, conjonctivite virale, rougeole et gastro-entérite, et la transmission de parasites comme les poux sont fréquentes dans les établissements scolaires et affectent les enfants et le personnel encadrant dont les enseignants. Ce risque professionnel est souvent négligé car considéré comme inévitable. À côté des risques infectieux, d'autres risques liés à des micro-organismes environnementaux et à leurs constituants comme les endotoxines peuvent exister. Ainsi, des études ont montré que les concentrations aéroportées de particules à l'intérieur des classes d'école étaient plus élevées qu'à l'extérieur (1) et que leur composition chimique était différente (2). Plusieurs études épidémiologiques ont montré un lien clair entre l'exposition à des particules et différents problèmes de santé notamment des problèmes respiratoires et cardiaques. Cette exposition à des particules en suspension dans l'air peut avoir des effets toxiques sur les cellules épithéliales des voies respiratoires. Deux études récentes menées dans des écoles et portant sur les particules aéroportées sont analysées ci-dessous. La première étude a évalué les effets biologiques in vitro de particules collectées dans des classes d'écoles en Allemagne et la seconde étude a mesuré les concentrations aéroportées de différents indicateurs de la qualité de l'air dont les micro-organismes dans des écoles au Portugal.