941 resultados para METAL-ION IMPLANTATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate immediate transcatheter aortic valve implantation (TAVI) results and medium-term follow-up in very elderly patients with severe and symptomatic aortic stenosis (AS). METHODS This multicenter, observational and prospective study was carried out in three hospitals. We included consecutive very elderly (> 85 years) patients with severe AS treated by TAVI. The primary endpoint was to evaluate death rates from any cause at two years. RESULTS The study included 160 consecutive patients with a mean age of 87 ± 2.1 years (range from 85 to 94 years) and a mean logistic EuroSCORE of 18.8% ± 11.2% with 57 (35.6%) patients scoring ≥ 20%. Procedural success rate was 97.5%, with 25 (15.6%) patients experiencing acute complications with major bleeding (the most frequent). Global mortality rate during hospitalization was 8.8% (n = 14) and 30-day mortality rate was 10% (n = 16). Median follow up period was 252.24 ± 232.17 days. During the follow-up period, 28 (17.5%) patients died (17 of them due to cardiac causes). The estimated two year overall and cardiac survival rates using the Kaplan-Meier method were 71% and 86.4%, respectively. Cox proportional hazard regression showed that the variable EuroSCORE ≥ 20 was the unique variable associated with overall mortality. CONCLUSIONS TAVI is safe and effective in a selected population of very elderly patients. Our findings support the adoption of this new procedure in this complex group of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El SPION (Super Paramagnetic Iron Oxide Nanoparticles) ha estat estudiat com un nou adsorbent per eliminar l’arsènic d’aigües contaminades. Les condicions òptimes de treball es van assolir per un pH de 3,6 i per concentracions inferiors als 100ppm. No es van trobar interferències significatives produïdes pels cations Cu, Ni i Zn en l’adsorció de l’As, sent el fosfat l’anió que més interfereix. Una esponja de cel·lulosa s’ha utilitzat com a suport del SPION, per disminuir les agregacions de les nanopartícules en suspensió i per proporcionar una material adequat per l’adsorció en continu, experiment amb columnes. Així, es va obtenir un augment de la capacitat d’adsorció del SPION per l’As(V), mentre que per l’As(III) continua sent baixa, per tant s’augmenta la selectivitat per l’As(V). Les interferències aniòniques afecten d’igual manera a l’adsorció de l’As(III) i l’As(V) quan l’adsorció és en continu o en discontinu. Els cations metàl·lics no interfereixen en l’adsorció de l’arsènic, a excepció del coure que és adsorbit i porta a la disminució de l’adsorció d’arsènic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a detailed investigation of the exohedral reactivity of the most important and abundant endohedral metallofullerene (EMF) is provided, that is, Sc3N@Ih-C80 and its D5h counterpart Sc3N@D5h-C80, and the (bio)chemically relevant lutetium- and gadolinium-based M3N@Ih/D5h-C80 EMFs (M=Sc, Lu, Gd). In particular, we analyze the thermodynamics and kinetics of the Diels–Alder cycloaddition of s-cis-1,3-butadiene on all the different bonds of the Ih-C80 and D5h-C80 cages and their endohedral derivatives. First, we discuss the thermodynamic and kinetic aspects of the cycloaddition reaction on the hollow fullerenes and the two isomers of Sc3N@C80. Afterwards, the effect of the nature of the metal nitride is analyzed in detail. In general, our BP86/TZP//BP86/DZP calculations indicate that [5,6] bonds are more reactive than [6,6] bonds for the two isomers. The [5,6] bond D5h-b, which is the most similar to the unique [5,6] bond type in the icosahedral cage, Ih-a, is the most reactive bond in M3N@D5h-C80 regardless of M. Sc3N@C80 and Lu3N@C80 give similar results; the regioselectivity is, however, significantly reduced for the larger and more electropositive M=Gd, as previously found in similar metallofullerenes. Calculations also show that the D5h isomer is more reactive from the kinetic point of view than the Ih one in all cases which is in good agreement with experiments

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sawhorse-type diruthenium tetracarbonyl complexes incorporating carboxyphenyl porphyrin bridges and pyridine axial ligands have been prepared, characterized and evaluated as potential photosensitizing and chemotherapeutic agents in several human cancer cells (A2780, A549, Me300, HeLa). The mono carboxyphenyl porphyrin derivatives, 5-(4-carboxyphenyl)-10,15,20-triphenyl-21,23H-porphyrin (HOOCR1-H2) and 5-(4-carboxyphenyl)-10,15,20-triphenylporphyrin-Zn (HOOCR1-Zn), after reaction with Ru-3(CO)(12) and pyridine, give the dinuclear complexes [Ru-2(CO)(4)(OOCR1-H2)(2)(NC5H5)(2)] (1) and [Ru-2(CO)(4)-(OOCR1-Zn)(2)(NC5H5)(2)] (2), respectively. Under the same reaction conditions, the di-carboxyphenyl porphyrin derivatives, 5,10-di(4-carboxyphenyl)-15,20-diphenyl-21,23H-porphyrin (HOOCR2-H2COOH) and 5,10-di(4-carboxyphenyl)-15,20-diphenylporphyrin-Zn (HOOCR2-ZnCOOH), give rise to the tetranuclear complexes, [{Ru-2(CO)(4)(NC5H5)(2)}(2)(OOCR2-H2COO)(2)] (3) and [{Ru-2(CO)(4)(NC5H5)(2! )}(2)(OOCR2-ZnCOO)(2)] (4), in which two sawhorse diruthenium tetracarbonyl units are linked by the di-carboxyphenyl porphyrin ligands. When tested in human cancer cell lines, both Zn(II) metallo-porphyrin derivatives 2 and 4 and the tetranuclear derivative 3 show some degree of cytotoxicity in the dark, but seem to present no phototoxicity upon irradiation at 652 nm. These results demonstrate the effect of the Zn(II) ion insertion into the porphyrin core, resulting in increased cytotoxicity and decreased phototoxicity. On the other hand, complex 1, the less cytotoxic derivative with IC50 > 170 mu M in HeLa cervix and A2780 ovarian cancer cell lines, shows an excellent phototoxicity toward these cancer cell lines with LD50 comprised between 4.5 and 7.5 J/cm(2) (irradiance 30 mW/cm(2)) at 5 mu M concentration (incubation time: 24 h). Overall, an excellent ratio between photo-and cytotoxicity has been found for the metal-free porphyrin derivative [Ru-2(CO)(4)(OOCR1-H2)(2)(! NC5H5)(2)] (1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Methods: Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Results: Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 mu g/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 mu g/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Conclusions: Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report confirms that this procedure is feasible and safe, and provides good results with low incidence of postoperative renal disorders. (Ann Thorac Surg 2010; 89: 1925-33) (C) 2010 by The Society of Thoracic Surgeons

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acid-sensing ion channels (ASICs) are neuronal Na(+) channels that belong to the epithelial Na(+) channel/degenerin family. ASICs are transiently activated by a rapid drop in extracellular pH. Conditions of low extracellular pH, such as ischemia and inflammation in which ASICs are thought to be active, are accompanied by increased protease activity. We show here that serine proteases modulate the function of ASIC1a and ASIC1b but not of ASIC2a and ASIC3. We show that protease exposure shifts the pH dependence of ASIC1a activation and steady-state inactivation to more acidic pH. As a consequence, protease exposure leads to a decrease in current response if ASIC1a is activated by a pH drop from pH 7.4. If, however, acidification occurs from a basal pH of approximately 7, protease-exposed ASIC1a shows higher activity than untreated ASIC1a. We provide evidence that this bi-directional regulation of ASIC1a function also occurs in neurons. Thus, we have identified a mechanism that modulates ASIC function and may allow ASIC1a to adapt its gating to situations of persistent extracellular acidification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèseObjectif: le remplacement valvulaire aortique par voie transcathétère est, actuellement, une méthode fiable indiquée pour des patients à haut risque porteurs d'une sténose valvulaire aortique. La voie transfémorale est utilisable seulement en cas d'absence de maladie vasculaire et la voie transapicale est contrindiquée en cas de dysfonction pulmonaire chronique sévère. Une alternative pour ne pas passer a travers l'espace pleural serait par voie sous- xiphoïdienne et trans-septale à travers le ventricule droit.Méthode: une expérience animale a été amené au laboratoire de recherche du CHUV. Cinq cochons (poids : 52.3±10.9 kg) ont été endormi et, sous anesthésie générale, le ventricule droit a été préparé a travers un accès sous- xiphoïdien. Ensuite, sous guide fluoroscopique et avec l'utilisation d'une échocardiographie intracardiaque, un accès trans-septal a été crée entre le ventricule droit et le ventricule gauche en utilisant des dilatateur de diamètre croissant (de 8F à 26F). Par la suite, une valve stentée crée dans le laboratoire en utilisant un stent en nitinol et du péricarde a été chargé dans une cartouche et introduite dans le ventricule gauche à travers un introducteur trans-septal. Enfin, la valve a été amené dans la chambre de chasse du ventricule gauche et ensuite dans la racine aortique et puis déployé au bon endroit. Quand le système a été retiré, le septum ventriculaire a pu être réparé par mise en place d'un système d'occlusion septal Amplazer. Trente minutes après la procédure, les animaux ont été sacrifié et le coeur a été analysé pour étudier le positionnement da la valve stentée, l'efficacité de la fermeture du septum inter-ventriculaire et la fermeture de la paroi du ventricule droit.Résultat : les cinq cochon ont tous eu un parfait positionnement et pose de la prothèse en position aortique au premier essai (efficacité 100%). Les procédures ont duré, moyennement, 49±4 minutes et la progressive dilatation de l'accès trans-septale à donné lieu à une communication inter-ventriculaire mesurable après dilatation avec du 18F et plus. Toutes les valves stentées ont été déployées au bon endroit avec un bon résultat du fonctionnement des valves prothétiques et absence d'insuffisance para prothétique. Pendant les procédures, des battement prématurés ainsi que des épisodes isolées de tachycardie supra ventriculaire ont été détectés. Par contre, il n'y a pas eu de bloc atrio-ventriculaire. Les pertes sanguines pendant les procédures étaient de 280±10mL, et les systèmes d'occlusion Amplatzer étaient tous bien déployés sans shunts inter-ventriculaires résiduels.Conclusion: la technique d'introduction de valve stentées par voie extrapleural (trans-ventriculaire et trans-septale) est techniquement possible et elle jette les bases pour le remplacement valvulaire aortique trans-ventriculaire sous anesthésie locale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the vascularization of the endometrium via hysteroscopy and to assess its correlation with angiogenic factor gene expression and embryo implantation rate.Design: Cross-sectional study.Setting: Public university hospital.Patient(s): Patients undergoing hysteroscopy for supposed infertility.Intervention(s): Endometrial quality assessment according to Sakumoto-Masamoto, performed in the early secretory phase of the cycle. Collection of an endometrial tissue biopsy.Main Outcome Measure(s): RNA extraction, reverse transcription, and determination of gene expression of angiogenesis- and implantation-relevant factors using quantitative polymerase chain reaction. Retrieval of pregnancy information from the medical records.Result(s): Good quantity/quality RNA with infertility history was obtained from 63 participating women. Those with a "good" endometrium and subsequent pregnancy showed increased gene expression for placenta growth factor when compared with patients with a "bad" endometrium and who did not succeed with pregnancy to date. Nonpregnant women with a "good" endometrium presented an intermediate result. No significant differences were observed for several other genes tested, but trends in the same direction were observed.Conclusion(s): This study demonstrates for the first time that endometrial PLGF expression corresponds to the hysteroscopic appearance of the endometrium, and therefore has potential as a clinically relevant prognosticator for infertility treatment success. (Fertil Steril (R) 2011;96:663-8. (C)2011 by American Society for Reproductive Medicine.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Échelle(s) : [ca 1:365 000], échelle de 4 lieues de poste de France [= 4,7 cm]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acid-sensing ion channels (ASICs) are neuronal Na(+)-selective channels that are transiently activated by extracellular acidification. ASICs are involved in fear and anxiety, learning, neurodegeneration after ischemic stroke, and pain sensation. The small molecule 2-guanidine-4-methylquinazoline (GMQ) was recently shown to open ASIC3 at physiological pH. We have investigated the mechanisms underlying this effect and the possibility that GMQ may alter the function of other ASICs besides ASIC3. GMQ shifts the pH dependence of activation to more acidic pH in ASIC1a and ASIC1b, whereas in ASIC3 this shift goes in the opposite direction and is accompanied by a decrease in its steepness. GMQ also induces an acidic shift of the pH dependence of inactivation of ASIC1a, -1b, -2a, and -3. As a consequence, the activation and inactivation curves of ASIC3 but not other ASICs overlap in the presence of GMQ at pH 7.4, thereby creating a window current. At concentrations >1 mm, GMQ decreases maximal peak currents by reducing the unitary current amplitude. Mutation of residue Glu-79 in the palm domain of ASIC3, previously shown to be critical for channel opening by GMQ, disrupted the GMQ effects on inactivation but not activation. This suggests that this residue is involved in the consequences of GMQ binding rather than in the binding interaction itself. This study describes the mechanisms underlying the effects of a novel class of ligands that modulate the function of all ASICs as well as activate ASIC3 at physiological pH.