966 resultados para Liquid chromatography-diode array detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method has been developed for extraction and determination of carbofuran in milk. The method involved direct injection of raw milk on to a human serum albumin dimethyloctyl-silica gel (HSA-Cs) column and the use of 80:20 (v/v) 0.01 M phosphate buffer pH 5.5 - acetonitrile as mobile phase. UV spectrophotometric detection was performed at 220 nm. Identification was based on retention time. Quantification was performed by automatic peak-area determination and was calibrated by use of an external standard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid and efficient analytical method is presented for the quantitative analysis of 10 organochlorine pesticides in corn meal. The extraction and clean up steps are combined into one step by transferring the sample to a chromatographic column prepacked with alumina and silica gel. The pesticides are eluted with n-hexane-dichloromethane 9:1 (v/v) and the extracts analized by gas-liquid chromatography with electron capture detection, the average recoveries were between 78% and 98% and the detection limits were between 1 and 5 ng/g.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The acidic ninhydrin spectrophotometric method (ANSM) for quantitative determination of free and bound sialic acid of milk glycoprotein has been proved to be fast and efficient for routine detection of fraudulent addition of rennet whey to fluid milk. In this research the ANSM was compared with the high performance liquid chromatography (HPLC) method, internationally recommended for caseinomacropeptide (CMP) determination, which besides its high accuracy is more sophisticated and requires trained personnel. For several sample conditions (raw milk and milk with variable added amounts of rennet cheese whey), the methods showed an excellent linear correlation, with r = 0.981 when milk was deproteinized with a 120 g.L-1 final concentration of trichloroacetic acid (TCA) concentration. The best correlations could be seen with final concentrations of 100 g.L-1 and 80 g.L-1 TCA; respectively, r = 0.992 and 0.993.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An amperometric biosensor based on cholinesterase (ChE) has been used for the determination of selected carbamate insecticides in vegetable samples. The linear range of the biosensor for the N-methylcarbamates (aldicarb, carbaryl, carbofuran, methomyl and propoxur) varied from 5 x 10(-5) to 50 mg kg(-1). Limits of detection were calculated on the basis that the ChE enzymes were 10% inhibited and varied, depending of the combination ChE (as acetyl- or butyrylcholinesterase) vs. inhibitor (pesticide), from 1 x 10(-4) to 3.5 mg kg(-1). The biosensor-based carbamate determination was compared to liquid chromatography/UV methods. Three vegetable samples were spiked with carbofuran and propoxur at 125 mu g kg(-1) followed by conventional procedures. Good correlations were observed for carbofuran in the vegetable extracts (79, 96 and 91% recoveries for potato, carrot and sweet pepper, respectively), whereas for propoxur unsatisfactory results were obtained. Potato and carrot samples were spiked with 10, 50 and 125 mu g kg(-1) carbofuran, followed by direct determination by the amperometric biosensor. The fortified sampler; resulted in very high inhibition values, and recoveries were: 28, 34 and 99% for potato, and 140, 90 and 101% for carrot, respectively, at these three fortification levels. (C) 1998 Elsevier B.V. B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method has been developed for the determination of the cocaine levels in samples of hair, using a chromatographic column internal surface reverse phase (ISRP)-C-18, for direct injection of the extracts of hair, without purification or derivation of the sample. The method allows monitoring an individual stopped for using or making cocaine. This method allowed the determination of levels of cocaine concentration in 75% of the analyzed samples of chemical dependents' hair, with cocaine detected at levels of 0.37-16.85 mug g(-1). In the other analyzed samples (25%), the drug was not detected, because the corresponding individuals told us that they consumed cocaine infrequently and in small amounts. The detection

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A small-scale method was developed for the simultaneous determination of γ-HCH, heptachlor, aldrin, dicofol, mirex, endosulfan I, endosulfan II and endosulfan sulphate in soil. The extraction and clean-up steps were combined into one step by transferring soil samples to chromatographic columns prepacked with neutral alumina. The pesticides elution was processed with n-hexane : dichloromethane (7:3) and the concentrated eluate was analysed using gas-liquid chromatography with electron capture detection. Analyses of the in vitro fortified samples with the selected pesticides were performed at three different levels. Mean recoveries for aldrin, γ-HCH and heptachlor, at levels of 2, 10 and 20 ng/g, ranged from 71 to 87%; for dicofol, at levels of 8, 40 and 80 ng/g, ranged from 97 to 103%; for endosulfan I and II, at levels of 5, 25 and 50 ng/g, ranged from 88 to 96%; for mirex, at levels of 6, 30 and 60 ng/g, ranged from 86 to 110%; and for endosulfan sulphate, at levels of 15, 75 and 150 ng/g, ranged from 93 to 104%. The method can be used for rapid determination of these pesticides in soil. © Springer-Verlag 1996.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, an in situ derivatization and extraction method for the determination of pentachlorophenol (PCP) has been applied successfully in the analysis of water samples. The PCP derivative analysis was performed by gas-liquid chromatography with electron capture detection. The limit of detection of the method is 1 μg/L and recoveries averaged 78-108% for PCP acetate at levels of 2, 10 and 20 μg/L.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of on-line C30-reversed-phase high-pressure liquid chromatography-nuclear magnetic resonance spectroscopy is described for the analysis of tetraglycosylated flavonoids in aqueous and hydroalcoholic extracts of the leaves of Maytenus aquifolium (Celastraceae). Triacontyl stationary phases showed adequate separation for on-line 1H-NMR measurements at 600 MHz and allowed the characterisation of these flavonoids by detection of both aromatic and anomeric proton signals. Copyright (C) 2000 John Wiley and Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The microbiological bioassay, the UV-spectrophotometry and the high performance liquid chromatography (HPLC) methods for assaying sparfloxacin in tablets were compared. The accuracy, repeatability, and precision of each method was assessed and precise. All methods were reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate and precise. The microbiological bioassay and HPLC are more specific than UV-spectrophotometric analysis. However, the microbiological bioassay requires 20 h to get results, and HPLC is the most expensive analysis. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The natural naphthopyranones paepalantine (1), paepalantine-9O-β-D-glucopyranoside (2) and paepalantine-9-O-β-D-allopyranosyl-(1→6)-O-β-D-glucopyranoside (3) were separated in a preparative scale from the ethanolic extract of the capitula of Paepalanthus bromelioides by high-speed counter-current chromatography (HSCCC). The solvent system used was composed of water-ethanol-ethyl acetate-hexane (10:4:10:4, v/v/v/v). This technique led to the separation of the three different naphthopyranone glycosides in pure form in approximately 7 hours. Paepalantine showed a good antioxidant activity when assayed by the DPPH radical spectrophotometric assay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two highly sensitive and selective methods based on gas chromatography coupled to mass spectrometry (GC-MS) in the selected ion monitoring (SIM) mode have been developed for the quantification of 2,6-dichlorophenol (2,6-DCP), a sex pheromone of the tick females of Anocentor nitens. Standard addition method and calibration curve techniques using 5-bromine-4-hydroxy-3- methoxybenzaldehyde (5-BrV) as internal standard (IS) afforded detection limit of 0.1ngml-1. The calibration curve was linear over the concentration range from 0.5 to 500ngml-1 for 2,6-DCP. Results show that the concentration range of sex pheromone in the extracts samples was 1.08-10.35ngml-1. The methods developed provided reliable procedures to determine amounts of 2,6-DCP present in ticks. © 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, rapid, and sensitive spectrophotometric method for routine analysis of saccharin in commercial noncaloric sweeteners is proposed. This method is based on the reaction of saccharin with tetrachloro-p-benzoquinone (p-chloranil) accelerated by hydrogen peroxide and conducted in an ethanol:acetone (4:1) medium, producing a violet-red compound (γ max = 550 nm). Beer's law is obeyed in a concentration range of 2.05 × 10 -4 to 3.00 × 10 -3 M with an excellent correlation coefficient (r = 0.9998). The detection limit was 1.55 × 10 -5 M, and the effect of interferences on the spectrophotometric measurements was evaluated. The proposed procedure was applied successfully to the determination of saccharin in noncaloric sweeteners. Recoveries were within 99.2-104.3% with standard deviations ranging from to 0.5-1.6%. Results of the proposed method compare very favorably with those given by the high-performance liquid chromatography method recommended by the Food and Drug Administration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hb Hasharon has an electrophoretic mobility similar to that of Hb S in cellulose acetate and a mobility between Hb S and C at acid pH. In high-performance liquid chromatography, Hb Hasharon shows a distinct chromatographic profile and retention time. The origin of this variant is a mutation in codon 47 (GAC → CAC) of the α2-globin gene, resulting in the replacement of asparagine by histidine during the translation process. Ten blood samples from individuals suspected of being Hb Hasharon carriers were analyzed. In addition to classic laboratory tests and high-performance liquid chromatography, molecular analysis by polymerase chain reaction with restriction fragment length polymorphism designed in the laboratory was performed to confirm this mutation. The study of these cases showed that a combination of classical and molecular methodologies is necessary in the diagnosis of hemoglobinopathies for a correct hemoglobin mutant identification. The accurate identification of hemoglobin variants is essential for genetic counseling and choice of therapy. ©FUNPEC-RP.