941 resultados para LIQUID-CHROMATOGRAPHY


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Xanthyletin is used as an inhibitor of the symbiotic fungus (Leucoagaricus gongylophorus) of the leaf-cutting ant (Atta sexdens rubropilosa), one of the most significant agricultural plague insects. The incorporation of this compound into nanoparticles is a promising approach to effectively control leaf-cutting ants. This study presents the development and validation of a specific analytical method using high-performance liquid chromatography (HPLC) for quantification of the xanthyletin content in biodegradable polymeric nanoparticles. The analytical methodology developed was specific, linear, accurate, precise, and robust. The absolute recovery of xanthyletin in colloidal suspensions was nearly 100%. The HPLC method proved reliable for the quantification of xanthyletin content in nanoparticle formulations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new method using the headspace solid phase microextraction (HS-SPME) technique was used to evaluate the infinite dilute activity coefficient (γ1∞) in an alcohol/water/salt system. The studied systems were ethanol and water with NaCl and NH4Cl at salt concentrations of 5, 10, 15, and 30% m/v and temperatures of 303.15 and 313.15 K. The method was used to investigate the salt effect on vapor/liquid equilibrium in an ethanol/water system, yielding satisfactory results. The study focused on the rich side in ethanol. The data were compared with the literature infinite dilution data determined by other methods such as differential ebulliometry (EBUL), differential static cell equilibrium (STAT), and gas-liquid chromatography with no gas phase correction (GC). In this study, NaCl showed better separation rates than NH4Cl.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A procedure was developed for determination of 5 sedatives and 14 β-blockers in swine kidney and subsequent analysis by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Three different procedures for extraction were tested, evaluated through recovery studies. The procedure using acetonitrile for extraction and cleanup with freezing at low temperature and dispersive solid phase extraction using 500 mg celite® 545 before the concentration step presented the better results. The dried samples were redissolved with methanol and analyzed using a LC-MS/MS system with electrospray ionization (ESI) operating in positive MRM mode. The recovery values for this procedure were in the 75-88% range. The robustness of the method was tested against small variations. The method was used to analyze carazolol, azaperone and azaperol in collaborative assay, obtaining results close to designed value.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The constant evolution of science and the growing demand for new technologies have led to new techniques in instrumentation that can improve detection, separation, resolution, and peak capacity. Comprehensive two-dimensional liquid chromatography (LC×LC) is presented as a powerful tool in complex sample analyses. During an analysis, a sample is subjected to two independent separation mechanisms that are combined, resulting in increased resolving power. For appropriate application of LC×LC, understanding the influence of parameters that require optimization is necessary. The main purpose of optimization is to predict the combination of stationary phases, separation conditions, and instrumental requirements to obtain the best separation performance. This review discusses theoretical, intrumental, and chemometric aspects of LC×LC and focuses on its applications in foods. It aims to provide a clear understanding of the aspects that can be used as strategies in the optimization of this analytical method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The filling of capillaries via the sol-gel process is growing. Therefore, this technical note focuses on disseminating knowledge acquired in the Group of Analytical Chemistry and Chemometrics over seven years working with monolithic stationary phase preparation in fused silica capillaries. We believe that the detailed information presented in this technical note concerning the construction of an alternative high pressurization device, used to fill capillary columns via the sol-gel process, which has promising potential for applications involving capillary electrochromatography and liquid chromatography in nano scale, may be enlightening and motivating for groups interested in developing research activities within this theme.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this study was to monitor 11 organophosphorus pesticides in samples of papaya, bell pepper, and banana, commercialized in the metropolitan area of Vitória (ES, Brazil). The pesticides were determined by an optimized and validated method using high performance liquid chromatography with tandem mass spectrometry (HPLC-MS/MS). All three samples exhibited a matrix effect for most of the pesticides, mainly with signal suppression, and therefore the calibration curves were produced in matrices. Linearity revealed coefficients of determination (r2) greater than 0.9895 for all pesticides and recovery results ranged from between 76% and 118% with standard deviation no greater than 16%. Precision showed relative standard deviation values lower than 19% and HorRat values lower than 0.7, considering all pesticides. Limits of quantification were less than 0.01 mg/kg for all pesticides. Regarding analysis of the samples (50 of each), none of the pesticides exceeded the maximum residue limit determined by Brazilian legislation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigated the reductive degradation of acetamiprid (5 mg L-1) in aqueous medium (at pH 2.0) induced by zero-valent iron (50 mg). The process was monitored using high-performance liquid chromatography (HPLC) to determine the degradation rate as a function of reaction time, and direct infusion electrospray ionization mass spectrometry (DI-ESI-MS) to search for (and potentially characterize) any possible byproducts formed during degradation. The results obtained via HPLC showed that after 60 min, the degradation of the substrate reached nearly 100% in an acidic medium, whereas the mineralization rate (as determined by total organic carbon measurements) was as low as 3%. Data obtained by DI-ESI-MS showed that byproducts were formed mainly by insertions of hydrogen atoms into the nitrile, imine, and pyridine ring moieties, in addition to the observation of chlorine substitution by hydrogen replacement (hydrodechlorination) reactions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Quetiapine is an atypical antipsychotic used to treat schizophrenia. However, despite great interest for its chronic therapeutic use, quetiapine has some important side effects such as weight gain induction. The development of a quetiapine nanocarrier can potentially target the drug into central nervous system, resulting in a reduction of systemic side effects and improved patient treatment. In the present work, a simple liquid chromatography/ultraviolet detection (LC/UV) analytical method was developed and validated for quantification of total quetiapine content in lipid core nanocapsules as well as for determination of incorporation efficiency. An algorithm proposed by Oliveira et al. (2012) was applied to characterize the distribution of quetiapine in the pseudo-phases of the nanocarrier, leading to a better understanding of the quetiapine nanoparticles produced. The analytical methodology developed was specific, linear in the range of 0.5 to 100 µg mL−1 (r2 > 0,99), and accurate and precise (R.S.D < ±5%). The absolute recovery of quetiapine from the nanoparticles was approximately 98% with an incorporation efficiency of approximately 96%. The results indicated that quetiapine was present in a type III distribution according to the algorithm, and was mainly located in the core of the nanoparticle because of its logD in the formulation pH (6.86 ± 0.4).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Liquid chromatography is often used for the determination of pesticide multiresidues in foods. In Brazil, the strawberry crop is an example of a food with high levels of irregularities because of the application of pesticides. This is a major concern from the perspective of food safety, environmental protection, and certification for food export. The purpose of this study is to evaluate and compare chromatographic separation and detection methods in relation to a newly developed and validated method using ultra high performance liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS) for the analytical determination of pesticides in strawberries. The comparisons were based on evaluations of the analysis time, consumption of the solvent in the mobile phase, injection volume, detectability, matrix effect, and recovery. The results showed that the LC–MS/MS and UHPLC–MS/MS techniques were both extremely efficient at analyzing pesticide residues with different physico-chemical parameters that were present at low concentrations in a complex matrix. The UHPLC separation method provided better chromatographic performance and productivity, which contributed favorably to routine analytical determinations. Detection by MS/MS had better detectability and selectivity compared with the diode array detector.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Specimens of Leonotis nepetiflolia were obtained from cultivated and wild environments to verify their influences in chemical composition. Phytochemical analyses were conducted for the ethyl acetate phase obtained by partitioning the crude ethanol extract from the cultivated leaves of L. nepetifolia. In doing so, flavonoid 3',4',5-trimethoxy-6,7-dihidroxyflavone (cirsiliol), a chemotaxonomic marker of the family Lamiaceae, was isolated. The results reveal that all phases and extracts tested exhibited weak to moderate antimicrobial activity against the strains of bacteria tested. The evaluation of in vitrocytotoxic and antitumor activity showed that the ethyl acetate phases obtained from both wild and cultivated leaves exhibit high potential cytotoxic and antitumor (> 78.0% of inhibition) activity. The major component of these phases was identified by high-performance liquid chromatography-diode array detector and nuclear magnetic resonance analyses using both 1D and 2D methods. The results further indicate that the flavonoid cirsiliol is the agent responsible for the activity observed in these phases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Since their original discovery in 1914, ionic liquids (IL) have been widely examined and explored in chemistry due to their unique physical and chemical properties. Ionic liquids are collectively known as organic salts and have melting points of 100 °C or under. The molten salts most employed in analytical chemistry, including gas chromatography (GC), consist of an organic cation paired with an organic or inorganic anion. This class of materials exhibits negligible vapor pressure and may have their properties (e.g.thermal stability and selectivity) structurally tuned by imparting different moieties to the cation/anion. Currently, there are an estimated 1018possible combinations of IL. In this context, the prospection of highly selective IL-based stationary phases for gas-liquid chromatography has enabled high peak capacity and efficient separations of many critical pairs in complex samples. In this review, we present and discuss fundamental characteristics of ionic liquids and introduce important solvation models for gas-liquid systems. In addition, recent advances and applications of IL in conventional and multidimensional gas chromatography are outlined.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electrodegradation of atrazine in water was performed using homemade (PA and PB) and purchased (PC) boron-doped diamond anodes. The degradation was monitored off-line by analyzing total organic carbon and high performance liquid chromatography with diode array detector (HPLC-DAD) and at-line by UV spectroscopy. The spectra were recorded every 2 min. The rank deficiency problem was resolved by assembling an augmented column-wise matrix. HPLC was employed to separate the original and byproducts degradation components. Aiming the same goal, multivariate curve resolution - alternating least squares (MCR-ALS) was applied to resolve the UV spectroscopic data. Comparison between HPLC and MCR-ALS separations is presented. By using MCR-ALS the spectra of atrazine and two byproducts were successfully resolved and the resulted concentration profiles properly represented the system studied. The ALS explained variance (R2) for PA, PB and PC was equal to 99.99% for all of them and the lack of fit for PA, PB and PC were 0.39, 0.34 and 0.54 respectively. The correlation (R) between the recovered and pure spectra were calculate for each electrodegradation, validating the MCR-ALS results. The average R was equal to 0.997. The spectral and concentration profiles described with this new approach are in agreement with HPLC-DAD results. The proposed method is an alternative to classical analyses for monitoring of the degradation process, mainly due to the simplicity, fast results and economy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hydrophilic interaction liquid chromatography (HILIC) has been gaining increased attention for its effective separation of highly polar compounds, which include carbohydrates, amino acids, pharmaceutical compounds, proteins, glycoproteins, nucleosides, etc. Polar compounds are usually poorly retained on reverse-phase liquid chromatography (RP-HPLC) columns or have poor solubility in the apolar mobile phase of normal-phase high performance liquid chromatography (NP-HPLC). Since HILIC uses organic solvents such as ACN or MeOH ( > 70%), also used in RP-HPLC and polar stationary phases similar to NP-HPLC (bare silica, diol, amino, amide, saccharide, zwitterionic stationary phases, etc.), it represents a hybrid of the two separation modes. The high organic content in the MP leads to good compatibility with mass spectrometry (MS), increasing the detectivity. This review describes the fundamentals of HILIC and highlights some interesting applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A L-ascorbic acid biosensor based on ascorbate oxidase has been developed. The enzyme was extracted from the mesocarp of cucumber (Cucumis sativus) by using 0.05 mol L-1 phosphate buffer, pH 5.8 containing 0.5 mol L-1 NaCl. After the dialysis versus phosphate buffer 0.05 mol L-1 pH 5.8, the enzyme was immobilized onto nylon net through glutaraldehyde covalent bond. The membrane was coupled to an O2 electrode and the yielding reaction monitored by oxygen depletion at -600 mV using flow injection analysis optimized to 0.1 mol L-1 phosphate buffer pH 5.8, as the carrier solution and flow-rate of 0.5 mL min-1. The ascorbic acid calibration curve was linear from 1.2x10-4 to 1.0x10-3 mol L-1. The evaluation of biosensor lifetime leads to 500 injections. Commercial pharmaceutical samples were analyzed with the proposed method and the results were compared with those obtained by high-performance liquid chromatography (HPLC).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The current study aims to verify the best method for a rapid and efficient extraction of flavonoids from Alpinia zerumbet. Dried leaves were extracted using distillated water and ethanol 70% by extraction methods of shaking maceration, ultrasonic, microwave and stirring. By the application of TLC and reversed-phase HPLC techniques the rutin and kaempferol-3-O-glucuronide were detected. Ethanol 70% was more efficient for flavonoids extraction than water. No significant yielding variation was verified for ultrasonic, microwave and stirring methods using ethanol 70% (11 to 14%). The relative concentration of rutin and kaempferol-3-O-glucuronide, respectively, was higher by ultrasonic (1.5 and 5.62 mg g-1 dried leaves, respectively) and by microwave (1.0 and 6.64 mg g-1 dried leaves) methods using ethanol. Rapid and simplified extraction proceeding optimize phytochemical work and acquisition of secondary metabolites.