940 resultados para Keyboard instrument music (Keyboard instruments (2))


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Self-absorption of the Eu2+ emission is an important aspect in SrI2:Eu that affects its scintillation performance. To calculate the probability of self-absorption, we measured the light yield and the decay time of 1–15 mm thick SrI2:2%Eu samples at temperatures between 78 K and 600 K. The obtained properties of SrI2:2%Eu crystals were then compared to those of SrI2:5%Eu. The decay times of SrI2:5%Eu crystals were the same or somewhat longer compared to those of twice as thickSrI2:2%Eu crystals. Accordingly, doubling the thickness has the same effect on the probability of self-absorption as doubling the Eu concentration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Seven rib-eye rolls, lip on (112A), were each cut into eight 2.54 centimeter thick steaks starting from the blade end. Steaks were randomly assigned to one of four treatment groups; 1) round versus square cores using Instron [inst1], 2) round versus square cores using Warner- Bratzler [inst2], 3) Instron versus Warner-Bratzler using round cores [rdsq1], and 4) Instron versus Warner- Bratzler using square cores [rdsq2]. Subsequently, steaks from each group were broiled in a General Electric industrial broiler grill to an internal temperature of 63 §C. Steaks were held overnight at 2 §C. Two steaks from each rib were placed into each instrument/core treatment group. Steaks were then divided into three sections identified as: a) lateral, b) medial, and c) central. Three 1.27 centimeter cores from each section were taken from each steak for a total of nine cores per steak and sheared once through the center. The results indicated that there was a significant difference ( p> .05) between round and square cores for both Warner- Bratzler and Instron. In all mean groups tested, square cores had higher shear values than did round cores. There was no indication of differences between instruments, and no significant interactions between instruments and core types.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Systematic reviews and meta-analyses of randomized trials that include patient-reported outcomes (PROs) often provide crucial information for patients, clinicians and policy-makers facing challenging health care decisions. Based on emerging methods, guidance on improving the interpretability of meta-analysis of patient-reported outcomes, typically continuous in nature, is likely to enhance decision-making. The objective of this paper is to summarize approaches to enhancing the interpretability of pooled estimates of PROs in meta-analyses. When differences in PROs between groups are statistically significant, decision-makers must be able to interpret the magnitude of effect. This is challenging when, as is often the case, clinical trial investigators use different measurement instruments for the same construct within and between individual randomized trials. For such cases, in addition to pooling results as a standardized mean difference, we recommend that systematic review authors use other methods to present results such as relative (relative risk, odds ratio) or absolute (risk difference) dichotomized treatment effects, complimented by presentation in either: natural units (e.g. overall depression reduced by 2.4 points when measured on a 50-point Hamilton Rating Scale for Depression); minimal important difference units (e.g. where 1.0 unit represents the smallest difference in depression that patients, on average, perceive as important the depression score was 0.38 (95%CI 0.30 to 0.47) units less than the control group); or a ratio of means (e.g. where the mean in the treatment group is divided by the mean in the control group, the ratio of means is 1.27, representing a 27%relative reduction in the mean depression score).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The spectacular images of Comet 103P/Hartley 2 recorded by the Medium Resolution Instrument (MRI) and High Resolution Instrument (HRI) on board of the Extrasolar Planet Observation and Deep Impact Extended Investigation (EPOXI) spacecraft, as the Deep Impact extended mission, revealed that its bi-lobed very active nucleus outgasses volatiles heterogeneously. Indeed, CO2 is the primary driver of activity by dragging out chunks of pure ice out of the nucleus from the sub-solar lobe that appear to be the main source of water in Hartley 2's coma by sublimating slowly as they go away from the nucleus. However, water vapor is released by direct sublimation of the nucleus at the waist without any significant amount of either CO2 or icy grains. The coma structure for a comet with such areas of diverse chemistry differs from the usual models where gases are produced in a homogeneous way from the surface. We use the fully kinetic Direct Simulation Monte Carlo model of Tenishev et al. (Tenishev, V.M., Combi, M.R., Davidsson, B. [2008]. Astrophys. J. 685, 659-677; Tenishev, V.M., Combi, M.R., Rubin, M. [2011]. Astrophys. J. 732, 104-120) applied to Comet 103P/Hartley 2 including sublimating icy grains to reproduce the observations made by EPOXI and ground-based measurements. A realistic bi-lobed nucleus with a succession of active areas with different chemistry was included in the model enabling us to study in details the coma of Hartley 2. The different gas production rates from each area were found by fitting the spectra computed using a line-by-line non-LTE radiative transfer model to the HRI observations. The presence of icy grains with long lifetimes, which are pushed anti-sunward by radiation pressure, explains the observed OH asymmetry with enhancement on the night side of the coma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hintergrund: Im Rahmen des neuen nationalen Medizinalberufegesetzes [http://www.admin.ch/ch/d/as/2007/4031.pdf], [http://www.bag.admin.ch/themen/berufe/07918/07919/index.html], der Entwicklung hin zu Kompetenz-basierten Curricula [1] und der Einführung der Bologna-Reform in den medizinischen Studiengängen [2] wurde in der Schweiz eine neue eidgenössische Schlussprüfung Humanmedizin unter Aufsicht des Bundes und in Zusammenarbeit mit den medizinischen Fakultäten in zwei Sprachen (D/F) entwickelt und 2011 erstmals durchgeführt. Projektbeschreibung: Im vorliegenden Beitrag werden die Rahmenbedingungen für die Implementierung aufgezeigt und die Entwicklung der Gesamtprüfung als Pass/Fail-Prüfung einschliesslich ihrer 2 Einzelprüfungen beschrieben. Die 1. Einzelprüfung besteht aus einer schriftlichen Prüfung (MCQ) an 2 Prüfungstagen zu je 4.5 h mit je 150 interdisziplinären, taxonomisch auf Anwendungswissen ausgerichteten Fragen. Die 2. Einzelprüfung umfasst eine strukturierte, klinisch-praktische CS-Prüfung (OSCE) mit insgesamt 12 Rotationsposten über je 13 min Dauer und je 2 min Rotationszeit zwischen den Posten. Zur Qualitätssicherung wurden zahlreiche Massnahmen ergriffen wie z.B. die Schulung der standardisierten Patienten anhand zentraler Standardisierungsvorlagen. Der Gesamtblueprint ist abgestimmt auf den Schweizer Lernzielkatalog Humanmedizin [http://sclo.smifk.ch] und beinhaltet die 2 Hauptdimensionen „General Objectives/CanMed Roles“ und „Problems as Starting Points“. Ergebnisse: Die Prüfung wurde an allen 5 Standorten 2011 und 2012 erfolgreich durchgeführt. Die Prüfungsresultate der ersten 2 Kohorten differenziert nach Gesamtprüfung und Einzelprüfungen zeigen in etwa die erwarteten Werte hinsichtlich der Bestehensquote. Die Metadaten zur Prüfungsqualität zeigen für beide Jahre, dass die angestrebte Messzuverlässigkeit der Prüfung mit einem Cronbach Alpha als Mass für die Reliabilität von im Mittel α=0.9 für die MCQ Einzelprüfung und von im Mittel α>0.8 für die CS-Einzelprüfung erreicht wurde. Diskussion und Schlussfolgerungen: Basierend auf den Erfahrungen und Daten der ersten 2 Prüfungskohorten kann gesagt werden, dass die Implementierung einer neuen nationalen Prüfung, die neben der neu ausgerichteten MCQ-Einzelprüfung erstmals mit einem strukturierten, objektivierbaren und national standardisierten Instrument klinische Fähigkeiten und Fertigkeiten misst, grundsätzlich gelungen ist. In diesem Kontext muss die Relevanz der intensiven Koordination und Abstimmung von der Gesetzgebung und den Verordnungsvorgaben bis hin zum Lernzielkatalog und dem korrespondierenden Gesamtblueprint der Prüfung hervorgehoben werden. Bezüglich der zukünftigen Entwicklung werden Aspekte der Qualitätssicherung und der Weiterentwicklung der Gesamtprüfung auch im Sinne von ergänzenden Prüfungsformaten diskutiert werden.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The design of Virtual Patients (VPs) is essential. So far there are no validated evaluation instruments for VP design published. Summary of work: We examined three sources of validity evidence of an instrument to be filled out by students aimed at measuring the quality of VPs with a special emphasis on fostering clinical reasoning: (1) Content was examined based on theory of clinical reasoning and an international VP expert team. (2) Response process was explored in think aloud pilot studies with students and content analysis of free text questions accompanying each item of the instrument. (3) Internal structure was assessed by confirmatory factor analysis (CFA) using 2547 student evaluations and reliability was examined utilizing generalizability analysis. Summary of results: Content analysis was supported by theory underlying Gruppen and Frohna’s clinical reasoning model on which the instrument is based and an international VP expert team. The pilot study and analysis of free text comments supported the validity of the instrument. The CFA indicated that a three factor model comprising 6 items showed a good fit with the data. Alpha coefficients per factor were 0,74 - 0,82. The findings of the generalizability studies indicated that 40-200 student responses are needed in order to obtain reliable data on one VP. Conclusions: The described instrument has the potential to provide faculty with reliable and valid information about VP design. Take-home messages: We present a short instrument which can be of help in evaluating the design of VPs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Stereotactic navigation technology can enhance guidance during surgery and enable the precise reproduction of planned surgical strategies. Currently, specific systems (such as the CAS-One system) are available for instrument guidance in open liver surgery. This study aims to evaluate the implementation of such a system for the targeting of hepatic tumors during robotic liver surgery. MATERIAL AND METHODS Optical tracking references were attached to one of the robotic instruments and to the robotic endoscopic camera. After instrument and video calibration and patient-to-image registration, a virtual model of the tracked instrument and the available three-dimensional images of the liver were displayed directly within the robotic console, superimposed onto the endoscopic video image. An additional superimposed targeting viewer allowed for the visualization of the target tumor, relative to the tip of the instrument, for an assessment of the distance between the tumor and the tool for the realization of safe resection margins. RESULTS Two cirrhotic patients underwent robotic navigated atypical hepatic resections for hepatocellular carcinoma. The augmented endoscopic view allowed for the definition of an accurate resection margin around the tumor. The overlay of reconstructed three-dimensional models was also used during parenchymal transection for the identification of vascular and biliary structures. Operative times were 240 min in the first case and 300 min in the second. There were no intraoperative complications. CONCLUSIONS The da Vinci Surgical System provided an excellent platform for image-guided liver surgery with a stable optic and instrumentation. Robotic image guidance might improve the surgeon's orientation during the operation and increase accuracy in tumor resection. Further developments of this technological combination are needed to deal with organ deformation during surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Effective visual exploration is required for many activities of daily living and instruments to assess visual exploration are important for the evaluation of the visual and the oculomotor system. In this article, the development of a new instrument to measure central and peripheral target recognition is described. The measurement setup consists of a hemispherical projection which allows presenting images over a large area of ±90° horizontal and vertical angle. In a feasibility study with 14 younger (21–49 years) and 12 older (50–78 years) test persons, 132 targets and 24 distractors were presented within naturalistic color photographs of everyday scenes at 10°, 30°, and 50° eccentricity. After the experiment, both younger and older participants reported in a questionnaire that the task is easy to understand, fun and that it measures a competence that is relevant for activities of daily living. A main result of the pilot study was that younger participants recognized more targets with smaller reaction times than older participants. The group differences were most pronounced for peripheral target detection. This test is feasible and appropriate to assess the functional field of view in younger and older adults.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measuring consumer satisfaction in the social services has become an important source of feedback for the improvement of service delivery. Consumer satisfaction has recently been incorporated into family preservation evaluation. This article reviews instruments used to measure consumer satisfaction in family preservation services and other related areas. Trends in current practice are examined and instrument dimensions are identified. Finally, some recommendations are made about the application of consumer satisfaction measurement in family preservation services.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Entire issue (large pdf file) Articles include: Behavior Problems of Maltreated Children Receiving In-Home Child Welfare Services. Ferol Mennen, William Meezan, Gino Aisenberg, and Jacquelyn McCroskey Measuring Consumer Satisfaction in Family Preservation Services: Identifying Instrument Domains. Stephen A. Kapp and Rebecca H Vela Intensive In-Home Family-Based Services: Reactions from Consumers and Providers Elaine Walton, and Alfred C. Dodini Coordination of Family Preservation Services in a Rural Community: A Case Study. Richard Freer and Kathleen Wells The Effectiveness of Court Mandated Intervention Versus Voluntary Services in Child Protective Services: Abbreviated Version. Loring Jones, Irene Becker, and Krista F alk

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Middle atmospheric water vapour can be used as a tracer for dynamical processes. It is mainly measured by satellite instruments and ground-based microwave radiometers. Ground-based instruments capable of measuring middle-atmospheric water vapour are sparse but valuable as they complement satellite measurements, are relatively easy to maintain and have a long lifetime. MIAWARA-C is a ground-based microwave radiometer for middle-atmospheric water vapour designed for use on measurement campaigns for both atmospheric case studies and instrument intercomparisons. MIAWARA-C's retrieval version 1.1 (v1.1) is set up in a such way as to provide a consistent data set even if the instrument is operated from different locations on a campaign basis. The sensitive altitude range for v1.1 extends from 4 hPa (37 km) to 0.017 hPa (75 km). For v1.1 the estimated systematic error is approximately 10% for all altitudes. At lower altitudes it is dominated by uncertainties in the calibration, with altitude the influence of spectroscopic and temperature uncertainties increases. The estimated random error increases with altitude from 5 to 25%. MIAWARA-C measures two polarisations of the incident radiation in separate receiver channels, and can therefore provide two measurements of the same air mass with independent instrumental noise. The standard deviation of the difference between the profiles obtained from the two polarisations is in excellent agreement with the estimated random measurement error of v1.1. In this paper, the quality of v1.1 data is assessed for measurements obtained at two different locations: (1) a total of 25 months of measurements in the Arctic (Sodankylä, 67.37° N, 26.63° E) and (2) nine months of measurements at mid-latitudes (Zimmerwald, 46.88° N, 7.46° E). For both locations MIAWARA-C's profiles are compared to measurements from the satellite experiments Aura MLS and MIPAS. In addition, comparisons to ACE-FTS and SOFIE are presented for the Arctic and to the ground-based radiometer MIAWARA for the mid-latitude campaigns. In general, all intercomparisons show high correlation coefficients, confirming the ability of MIAWARA-C to monitor temporal variations of the order of days. The biases are generally below 13% and within the estimated systematic uncertainty of MIAWARA-C. No consistent wet or dry bias is identified for MIAWARA-C. In addition, comparisons to the reference instruments indicate the estimated random error of v1.1 to be a realistic measure of the random variation on the retrieved profile between 45 and 70 km.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using stress and coping as a unifying theoretical concept, a series of five models was developed in order to synthesize the survey questions and to classify information. These models identified the question, listed the research study, described measurements, listed workplace data, and listed industry and national reference data.^ A set of 38 instrument questions was developed within the five coping correlate categories. In addition, a set of 22 stress symptoms was also developed. The study was conducted within two groups, police and professors, on a large university campus. The groups were selected because their occupations were diverse, but they were a part of the same macroenvironment. The premise was that police officers would be more highly stressed than professors.^ Of a total study group of 80, there were 37 respondents. The difference in the mean stress responses was observable between the two groups. Not only were the responses similar within each group, but the stress level of response was also similar within each group. While the response to the survey instrument was good, only 3 respondents answered the stress symptom survey properly. It was determined that none of the 37 respondents believed that they were ill. This perception of being well was also evidenced by the grand mean of the stress scores of 2.76 (3.0 = moderate stress). This also caused fewer independent variables to be entered in the multiple regression model.^ The survey instrument was carefully designed to be universal. Universality is the ability to transcend occupational or regional definitions as applied to stress. It is the ability to measure responses within broad categories such as physiological, emotional, behavioral, social, and cognitive functions without losing the ability to measure the detail within the individual questions, or the relationships between questions and categories.^ Replication is much easier to achieve with standardized categories, questions, and measurement procedures such as those developed for the universal survey instrument. Because the survey instrument is universal it can be used as an analytical device, an assessment device, a basic tool for planning and a follow-up instrument to measure individual response to planned reductions in occupational stress. (Abstract shortened with permission of author.) ^