922 resultados para Interpretation of History


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper looks at the emergence of what is described here as the QWERTY family of standards (QWERTY and its international adaptations QZERTY, AZERTY, and QWERTZ). QWERTY has been described as an inferior solution and an accident of history. However, the analysis here finds that each member of the family represented highly efficient adaptations to specific user needs and technical challenges encountered in their own environments. These findings may be seen to have wider implications given QWERTY’s role as paradigm case in the literature on increasing returns and path dependence, and these are pursued in the paper

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Colistin is a last resort's antibacterial treatment in critically ill patients with multi-drug resistant Gram-negative infections. As appropriate colistin exposure is the key for maximizing efficacy while minimizing toxicity, individualized dosing optimization guided by therapeutic drug monitoring is a top clinical priority. Objective of the present work was to develop a rapid and robust HPLC-MS/MS assay for quantification of colistin plasma concentrations. This novel methodology validated according to international standards simultaneously quantifies the microbiologically active compounds colistin A and B, plus the pro-drug colistin methanesulfonate (colistimethate, CMS). 96-well micro-Elution SPE on Oasis Hydrophilic-Lipophilic-Balanced (HLB) followed by direct analysis by Hydrophilic Interaction Liquid Chromatography (HILIC) with Ethylene Bridged Hybrid - BEH - Amide phase column coupled to tandem mass spectrometry allows a high-throughput with no significant matrix effect. The technique is highly sensitive (limit of quantification 0.014 and 0.006μg/mL for colistin A and B), precise (intra-/inter-assay CV 0.6-8.4%) and accurate (intra-/inter-assay deviation from nominal concentrations -4.4 to +6.3%) over the clinically relevant analytical range 0.05-20μg/mL. Colistin A and B in plasma and whole blood samples are reliably quantified over 48h at room temperature and at +4°C (<6% deviation from nominal values) and after three freeze-thaw cycles. Colistimethate acidic hydrolysis (1M H2SO4) to colistin A and B in plasma was completed in vitro after 15min of sonication while the pro-drug hydrolyzed spontaneously in plasma ex vivo after 4h at room temperature: this information is of utmost importance for interpretation of analytical results. Quantification is precise and accurate when using serum, citrated or EDTA plasma as biological matrix, while use of heparin plasma is not appropriate. This new analytical technique providing optimized quantification in real-life conditions of the microbiologically active compounds colistin A and B offers a highly efficient tool for routine therapeutic drug monitoring aimed at individualizing drug dosing against life-threatening infections.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Participation is a key indicator of the potential effectiveness of any population-based intervention. Defining, measuring and reporting participation in cancer screening programmes has become more heterogeneous as the number and diversity of interventions have increased, and the purposes of this benchmarking parameter have broadened. This study, centred on colorectal cancer, addresses current issues that affect the increasingly complex task of comparing screening participation across settings. Reports from programmes with a defined target population and active invitation scheme, published between 2005 and 2012, were reviewed. Differences in defining and measuring participation were identified and quantified, and participation indicators were grouped by aims of measure and temporal dimensions. We found that consistent terminology, clear and complete reporting of participation definition and systematic documentation of coverage by invitation were lacking. Further, adherence to definitions proposed in the 2010 European Guidelines for Quality Assurance in Colorectal Cancer Screening was suboptimal. Ineligible individuals represented 1% to 15% of invitations, and variable criteria for ineligibility yielded differences in participation estimates that could obscure the interpretation of colorectal cancer screening participation internationally. Excluding ineligible individuals from the reference population enhances comparability of participation measures. Standardised measures of cumulative participation to compare screening protocols with different intervals and inclusion of time since invitation in definitions are urgently needed to improve international comparability of colorectal cancer screening participation. Recommendations to improve comparability of participation indicators in cancer screening interventions are made.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Distinguishing postmortem gas accumulations in the body due to natural decomposition and other phenomena such as gas embolism can prove a difficult task using purely Multi-Detector Computed Tomography (MDCT). The Radiological Alteration Index (RAI) was created with the intention to be able to identify bodies undergoing the putrefaction process based on the quantity of gas detected within the body. The flaw in this approach is the inability to absolutely determine putrefaction as the origin of gas volumes in cases of moderate alteration. The aim of the current study is to identify percentage compositions of O2, N2, CO2 and the presence of gases such as H2 and H2S within these sampling sites in order to resolve this complication. Materials and methods: All cases investigated in our University Center of Legal Medicine are undergoing a Post-Mortem Computed Tomography (PMCT)-scan before external examination or autopsy as a routine investigation. In the obtained images, areas of gas were characterized as 0, I, II or III based on the amount of gas present according to the RAI (1). The criteria for these characterizations were dependent of the site of gas, for example thoracic and abdominal cavities were graded as I (1 - 3cm gas), II (3 - 5cm gas) and III (>5cm gas). Cases showing gaseous sites with grade II or III were selected for this study. The sampling was performed under CT-guidance to target the regions to be punctured. Luer-lock PTFE syringes equipped with a three-way valve and needles were used to sample the gas directly (2). Gaseous samples were then analysed using gas chromatography coupled to a thermal conductivity detector (GC-TCD). The components present in the samples were expressed as a percentage of the overall gas present. Results: Up to now, we have investigated more than 40 cases using our standardized procedure for sampling and analysis of gas. O2, N2 and CO2 were present in most samples. The following distributions were found to correlate to gas origins of gas embolism/scuba diving accidents, trauma and putrefaction: ? Putrefaction → O2 = 1 - 5%; CO2 > 15%; N2 = 10 - 70%; H2 / H2S / CH4 variable presence ? Gas embolism/Scuba diving accidents → O2 and N2= varying percentages; CO2 > 20% ? Trauma → O2 = small percentage; CO2 < 15%; N2 > 65% H2 and H2S indicated levels of putrefaction along with methane which can also gauge environmental conditions or conditions of body storage/burial. Many cases showing large RAI values (advanced alteration) did reveal a radiological diagnosis which was in concordance with the interpretation of the gas composition. However, in certain cases (gas embolism, scuba divers) radiological interpretation was not possible and only chemical gas analysis was found to lead to the correct diagnosis, meaning that it provided complementary information to the radiological diagnosis. Conclusion: Investigation of postmortem gases is a useful tool to determine origin of gas generation which can aid the diagnosis of the cause of death. Levels of gas can provide information on stage of putrefaction and help to perform essential medico-legal diagnosis such as vital gas embolism.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Retrospective analyses suggest that personalized PK-based dosage might be useful for imatinib, as treatment response correlates with trough concentrations (Cmin) in cancer patients. Our objectives were to improve the interpretation of randomly measured concentrations and to confirm its efficiency before evaluating the clinical usefulness of systematic PK-based dosage in chronic myeloid leukemia patients. Methods and Results: A Bayesian method was validated for the prediction of individual Cmin on the basis of a single random observation, and was applied in a prospective multicenter randomized controlled clinical trial. 28 out of 56 patients were enrolled in the systematic dosage individualization arm and had 44 follow-up visits (their clinical follow-up is ongoing). PK-dose-adjustments were proposed in 39% having predicted Cmin significantly away from the target (1000 ng/ml). Recommendations were taken up by physicians in 57%, patients were considered non-compliant in 27%. Median Cmin at study inclusion was 754 ng/ml and differed significantly from the target (p=0.02, Wilcoxon test). On follow-up, Cmin was 984 ng/ml (p=0.82) in the compliant group. CV decreased from 46% to 27% (p=0.02, F-test). Conclusion: PK-based (Bayesian) dosage adjustment is able to bring individual drug exposure closer to a given therapeutic target. Its influence on therapeutic response remains to be evaluated.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives: Several population pharmacokinetic (PPK) and pharmacokinetic-pharmacodynamic (PK-PD) analyses have been performed with the anticancer drug imatinib. Inspired by the approach of meta-analysis, we aimed to compare and combine results from published studies in a useful way - in particular for improving the clinical interpretation of imatinib concentration measurements in the scope of therapeutic drug monitoring (TDM). Methods: Original PPK analyses and PK-PD studies (PK surrogate: trough concentration Cmin; PD outcomes: optimal early response and specific adverse events) were searched systematically on MEDLINE. From each identified PPK model, a predicted concentration distribution under standard dosage was derived through 1000 simulations (NONMEM), after standardizing model parameters to common covariates. A "reference range" was calculated from pooled simulated concentrations in a semi-quantitative approach (without specific weighting) over the whole dosing interval. Meta-regression summarized relationships between Cmin and optimal/suboptimal early treatment response. Results: 9 PPK models and 6 relevant PK-PD reports in CML patients were identified. Model-based predicted median Cmin ranged from 555 to 1388 ng/ml (grand median: 870 ng/ml and inter-quartile range: 520-1390 ng/ml). The probability to achieve optimal early response was predicted to increase from 60 to 85% from 520 to 1390 ng/ml across PK-PD studies (odds ratio for doubling Cmin: 2.7). Reporting of specific adverse events was too heterogeneous to perform a regression analysis. The general frequency of anemia, rash and fluid retention increased however consistently with Cmin, but less than response probability. Conclusions: Predicted drug exposure may differ substantially between various PPK analyses. In this review, heterogeneity was mainly attributed to 2 "outlying" models. The established reference range seems to cover the range where both good efficacy and acceptable tolerance are expected for most patients. TDM guided dose adjustment appears therefore justified for imatinib in CML patients. Its usefulness remains now to be prospectively validated in a randomized trial.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Forensic scientists have long detected the presence of drugs and their metabolites in biological materials using body fluids such as urine, blood and/or other biological liquids or tissues. For doping analysis, only urine has so far been collected. In recent years, remarkable advances in sensitive analytical techniques have encouraged the analysis of drugs in unconventional biological samples such as hair, saliva and sweat. These samples are easily collected, although drug levels are often lower than the corresponding levels in urine or blood. This chapter reviews recent studies in the detection of doping agents in hair, saliva and sweat. Sampling, analytical procedures and interpretation of the results are discussed in comparison with those obtained from urine and blood samples.