973 resultados para Installation of equipment
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Geografia - IGCE
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work approaches the analysis of industrial refrigeration systems applied to a chemical processing industry that, in this case, consists of refrigeration machines, cooling tower system, cold water system and brine system. In this study it is highlighted the function and characteristics of different systems, including the main components, the most important features, their functionality and best practices. The motivation for this work is the fact that refrigeration systems are essential in many industrial processes, presenting a high energy consumption that is related to a significant parcel of production costs. It has aimed to understand the case studied in order to evaluate the energy efficiency of systems and to compare with Carnot efficiency and best available technologies. The assessment aims to identify irregularities, find opportunities and propose solutions that increases the performance of equipment and the overall system efficiency. Therefore, the studies intend to reduce the operation costs and generate gains for the company
Resumo:
The purpose of the ergonomics is to generate adequate working conditions, by the correct use of equipment and appropriate anatomic positions. Ergonomics has become essential in the dentist's life while in the dental practice. The misuse of equipment in performing tasks or the wrong choice of equipment can initiate various problems like back pain, bursitis, repetitive strain injury (RSI), limitation of movement, and stress. Using a survey that was implemented with professional dentists linked to Paulista Association of Dental Surgeons (APCD) and graduate students at the Universidade Estadual Paulista (UNESP) in the São José dos Campos (SP) region, this study intends to propose an adequate research instrument to identify ergonomic critical factors of dental stools and their relation to productivity and satisfaction of dentists. The survey was developed with Google Docs Forms tool and was designed by analysis of other studies, existing surveys and other papers in this area. Relevant content were discussed and developed questions about the stool used by dentists in their activities, the occurrence of any problems arising from the exercise of their profession and the views of respondents about the influence of using the dental stool in these cited problems as well as their productivity. Due to obstacles encountered during the project, particularly bureaucratic issues, the survey cannot be implemented as needed, resulting in a test with reduced number of answers. The users' opinion varies according to the stool used, bringing some difficulty to generalizing the answers, but if treated properly, it is possible to obtain relevant conclusions about the main aspects perceived by users in relation to the stool and the needs pointed as most important
Resumo:
Pós-graduação em Geografia - IGCE
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work approaches the analysis of industrial refrigeration systems applied to a chemical processing industry that, in this case, consists of refrigeration machines, cooling tower system, cold water system and brine system. In this study it is highlighted the function and characteristics of different systems, including the main components, the most important features, their functionality and best practices. The motivation for this work is the fact that refrigeration systems are essential in many industrial processes, presenting a high energy consumption that is related to a significant parcel of production costs. It has aimed to understand the case studied in order to evaluate the energy efficiency of systems and to compare with Carnot efficiency and best available technologies. The assessment aims to identify irregularities, find opportunities and propose solutions that increases the performance of equipment and the overall system efficiency. Therefore, the studies intend to reduce the operation costs and generate gains for the company
Resumo:
The purpose of the ergonomics is to generate adequate working conditions, by the correct use of equipment and appropriate anatomic positions. Ergonomics has become essential in the dentist's life while in the dental practice. The misuse of equipment in performing tasks or the wrong choice of equipment can initiate various problems like back pain, bursitis, repetitive strain injury (RSI), limitation of movement, and stress. Using a survey that was implemented with professional dentists linked to Paulista Association of Dental Surgeons (APCD) and graduate students at the Universidade Estadual Paulista (UNESP) in the São José dos Campos (SP) region, this study intends to propose an adequate research instrument to identify ergonomic critical factors of dental stools and their relation to productivity and satisfaction of dentists. The survey was developed with Google Docs Forms tool and was designed by analysis of other studies, existing surveys and other papers in this area. Relevant content were discussed and developed questions about the stool used by dentists in their activities, the occurrence of any problems arising from the exercise of their profession and the views of respondents about the influence of using the dental stool in these cited problems as well as their productivity. Due to obstacles encountered during the project, particularly bureaucratic issues, the survey cannot be implemented as needed, resulting in a test with reduced number of answers. The users' opinion varies according to the stool used, bringing some difficulty to generalizing the answers, but if treated properly, it is possible to obtain relevant conclusions about the main aspects perceived by users in relation to the stool and the needs pointed as most important
Resumo:
Pós-graduação em Geografia - IGCE
Resumo:
A power transformer needs continuous monitoring and fast protection as it is a very expensive piece of equipment and an essential element in an electrical power system. The most common protection technique used is the percentage differential logic, which provides discrimination between an internal fault and different operating conditions. Unfortunately, there are some operating conditions of power transformers that can mislead the conventional protection affecting the power system stability negatively. This study proposes the development of a new algorithm to improve the protection performance by using fuzzy logic, artificial neural networks and genetic algorithms. An electrical power system was modelled using Alternative Transients Program software to obtain the operational conditions and fault situations needed to test the algorithm developed, as well as a commercial differential relay. Results show improved reliability, as well as a fast response of the proposed technique when compared with conventional ones.
Resumo:
Recent studies in animals have shown pronounced resorption of the buccal bone plate after immediate implantation. The use of flapless surgical procedures prior to the installation of immediate implants, as well as the use of synthetic bone graft in the gaps represent viable alternatives to minimize buccal bone resorption and to favor osseointegration. The aim of this study was to evaluate the healing of the buccal bone plate following immediate implantation using the flapless approach, and to compare this process with sites in which a synthetic bone graft was or was not inserted into the gap between the implant and the buccal bone plate. Lower bicuspids from 8 dogs were bilaterally extracted without the use of flaps, and 4 implants were installed in the alveoli in each side of the mandible and were positioned 2.0 mm from the buccal bone plate (gap). Four groups were devised: 2.0-mm subcrestal implants (3.3 x 8 mm) using bone grafts (SCTG), 2.0-mm subcrestal implants without bone grafts (SCCG), equicrestal implants (3.3 x 10 mm) with bone grafts (EGG), and equicrestal implants without bone grafts (ECCG). One week following the surgical procedures, metallic prostheses were installed, and within 12 weeks the dogs were sacrificed. The blocks containing the individual implants were turned sideways, and radiographic imaging was obtained to analyze the remodeling of the buccal bone plate. In the analysis of the resulting distance between the implant shoulder and the bone crest, statistically significant differences were found in the SCTG when compared to the ECTG (P = .02) and ECCG (P = .03). For mean value comparison of the resulting linear distance between the implant surface and the buccal plate, no statistically significant difference was found among all groups (P > .05). The same result was observed in the parameter for presence or absence of tissue formation between the implant surface and buccal plate. Equicrestally placed implants, in this methodology, presented little or no loss of the buccal bone. The subcrestally positioned implants presented loss of buccal bone, even though synthetic bone graft was used. The buccal bone, however, was always coronal to the implant shoulder.
Resumo:
O objetivo deste estudo foi analisar a reprodutibilidade de parâmetros no domínio da frequência do sinal eletromiográfico (EMG) utilizados na caracterização da fadiga muscular localizada. Quinze sujeitos do sexo masculino foram submetidos a um teste de fadiga baseado na extensão isométrica de joelho, sendo realizados em três momentos distintos com intervalos de sete dias. Para avaliar a reprodutibilidade dos dados entres os testes calculou-se o coeficiente de correlação intraclasse (CCI) para a frequência mediana (Fmed) no tempo total de exercício (FmedT), para a Fmed obtida a cada 10% do tempo de exercício (Fmed10%) e para as potências das bandas de frequência, obtidas da divisão do espectro de potência a cada 20 Hz. Os resultados demonstraram: (1) boa reprodutibilidade para a FmedT; (2) boa reprodutibilidade para a Fmed10%; e (3) maior variação no sinal EMG nas bandas de 20 a 120 Hz, no qual se destacam as bandas de 20-40 Hz e de 40-60 Hz, demonstrando maior sensibilidade ao processo de fadiga muscular. Conclui-se que a Fmed é uma variável que apresenta boa reprodutibilidade e que a análise fragmentada do espectro de potência, por meio das bandas de frequência, demonstrou-se sensível as variações que ocorrem no sinal EMG durante a instalação do processo de fadiga, tendo potencial para se tornar um novo método para a caracterização da fadiga muscular localizada.
Resumo:
O presente relato tem por objetivo descrever o primeiro caso alóctone de leishmaniose visceral (LV) no município de Campo Mourão, Paraná, Brasil, em um canino, da raça Boxer, apresentando lesões oculares e cutâneas, linfoadenomegalia e esplenomegalia, atendido no Hospital Veterinário da Faculdade Integrado de Campo Mourão, após ter residido na cidade de Campo Grande, Mato Grosso do Sul. O diagnóstico da enfermidade baseou-se na observação direta de formas amastigotas de Leishmania spp., em linfonodos poplíteos, sugerindo ser um caso de LV, uma vez que o animal era proveniente de área endêmica para a enfermidade. A migração de cães infectados de regiões endêmicas para áreas indenes torna-se um problema para a saúde pública, uma vez que poderá permitir a instalação de novos focos, favorecendo a disseminação da doença em todo o país.