967 resultados para Image quality
Resumo:
A two terminal optically addressed image processing device based on two stacked sensing/switching p-i-n a-SiC:H diodes is presented. The charge packets are injected optically into the p-i-n sensing photodiode and confined at the illuminated regions changing locally the electrical field profile across the p-i-n switching diode. A red scanner is used for charge readout. The various design parameters and addressing architecture trade-offs are discussed. The influence on the transfer functions of an a-SiC:H sensing absorber optimized for red transmittance and blue collection or of a floating anode in between is analysed. Results show that the thin a-SiC:H sensing absorber confines the readout to the switching diode and filters the light allowing full colour detection at two appropriated voltages. When the floating anode is used the spectral response broadens, allowing B&W image recognition with improved light-to-dark sensitivity. A physical model supports the image and colour recognition process.
Resumo:
Recently, several distributed video coding (DVC) solutions based on the distributed source coding (DSC) paradigm have appeared in the literature. Wyner-Ziv (WZ) video coding, a particular case of DVC where side information is made available at the decoder, enable to achieve a flexible distribution of the computational complexity between the encoder and decoder, promising to fulfill novel requirements from applications such as video surveillance, sensor networks and mobile camera phones. The quality of the side information at the decoder has a critical role in determining the WZ video coding rate-distortion (RD) performance, notably to raise it to a level as close as possible to the RD performance of standard predictive video coding schemes. Towards this target, efficient motion search algorithms for powerful frame interpolation are much needed at the decoder. In this paper, the RD performance of a Wyner-Ziv video codec is improved by using novel, advanced motion compensated frame interpolation techniques to generate the side information. The development of these type of side information estimators is a difficult problem in WZ video coding, especially because the decoder only has available some reference, decoded frames. Based on the regularization of the motion field, novel side information creation techniques are proposed in this paper along with a new frame interpolation framework able to generate higher quality side information at the decoder. To illustrate the RD performance improvements, this novel side information creation framework has been integrated in a transform domain turbo coding based Wyner-Ziv video codec. Experimental results show that the novel side information creation solution leads to better RD performance than available state-of-the-art side information estimators, with improvements up to 2 dB: moreover, it allows outperforming H.264/AVC Intra by up to 3 dB with a lower encoding complexity.
Resumo:
We report in this paper the recent advances we obtained in optimizing a color image sensor based on the laser-scanned-photodiode (LSP) technique. A novel device structure based on a a-SiC:H/a-Si:H pin/pin tandem structure has been tested for a proper color separation process that takes advantage on the different filtering properties due to the different light penetration depth at different wavelengths a-SM and a-SiC:H. While the green and the red images give, in comparison with previous tested structures, a weak response, this structure shows a very good recognition of blue color under reverse bias, leaving a good margin for future device optimization in order to achieve a complete and satisfactory RGB image mapping. Experimental results about the spectral collection efficiency are presented and discussed from the point of view of the color sensor applications. The physics behind the device functioning is explained by recurring to a numerical simulation of the internal electrical configuration of the device.
Resumo:
Large area hydrogenated amorphous silicon single and stacked p-i-n structures with low conductivity doped layers are proposed as monochrome and color image sensors. The layers of the structures are based on amorphous silicon alloys (a-Si(x)C(1-x):H). The current-voltage characteristics and the spectral sensitivity under different bias conditions are analyzed. The output characteristics are evaluated under different read-out voltages and scanner wavelengths. To extract information on image shape, intensity and color, a modulated light beam scans the sensor active area at three appropriate bias voltages and the photoresponse in each scanning position ("sub-pixel") is recorded. The investigation of the sensor output under different scanner wavelengths and varying electrical bias reveals that the response can be tuned, thus enabling color separation. The operation of the sensor is exemplified and supported by a numerical simulation.
Resumo:
In recent works large area hydrogenated amorphous silicon p-i-n structures with low conductivity doped layers were proposed as single element image sensors. The working principle of this type of sensor is based on the modulation, by the local illumination conditions, of the photocurrent generated by a light beam scanning the active area of the device. In order to evaluate the sensor capabilities is necessary to perform a response time characterization. This work focuses on the transient response of such sensor and on the influence of the carbon contents of the doped layers. In order to evaluate the response time a set of devices with different percentage of carbon incorporation in the doped layers is analyzed by measuring the scanner-induced photocurrent under different bias conditions.
Resumo:
An optimized ZnO:Al/a-pin SixCl1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed. The LSP utilizes light induced depletion layers as detector and a laser beam for readout. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Experimental data reveal that the large optical gap and the low conductivity of the doped a-SixC1-x:H layers are responsible by an induced inversion layer at the illuminated interfaces which blocks the carrier collection. These insulator-like layers act as MIS gates preventing image smearing. The physical background of the LSP is discussed.
Resumo:
An optimized ZnO:Al/a-pin SixC1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed and the read-out parameters improved. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Data reveals that for sensors with wide band gap doped layers an increase on the image signal optimized to the blue is achieved with a dynamic range of two orders of magnitude, a responsivity of 6 mA W-1 and a sensitivity of 17 muW cm(-2) at 530 nm. The main output characteristics such as image responsivity, resolution, linearity and dynamic range were analyzed under reverse, forward and short circuit modes. The results show that the sensor performance can be optimized in short circuit mode. A trade-off between the scan time and the required resolution is needed since the spot size limits the resolution due to the cross-talk between dark and illuminated regions leading to blurring effects.
Resumo:
This work presents preliminary results in the study of a novel structure for a laser scanned photodiode (LSP) type of image sensor. In order to increase the signal output, a stacked p-i-n-p-i-n structure with an intermediate light-blocking layer is used. The image and the scanning beam are incident through opposite sides of the sensor and their absorption is kept in separate junctions by an intermediate light-blocking layer. As in the usual LSP structure the scanning beam-induced photocurrent is dependent on the local illumination conditions of the image. The main difference between the two structures arises from the fact that in this new structure the image and the scanner have different optical paths leading to an increase in the photocurrent when the scanning beam is incident on a region illuminated on the image side of the sensor, while a decreasing in the photocurrent was observed in the single junction LSP. The results show that the structure can be successfully used as an image sensor even though some optimization is needed to enhance the performance of the device.
Resumo:
Liver transplantation is the unique treatment for several end stage diseases. Familial Amiloidotic Polineuropathy (FAP) is a neurodegenerative disease related with systemic deposition of amyloidal fibre mainly on peripheral nervous system, clinically translated by an autonomous sensitive-motor neuropathy with severe functional limitations in some cases. The unique treatment for FAP disease is a liver transplant with a very aggressive medication to muscle metabolism and force production. To our knowledge there are no quantitative characterizations of body composition, strength or functional capacity in this population. The purpose of this study was to compare levels of specific strength (isometric strength adjusted by lean mass or muscle quality) and functional capacity (meters in 6 minutes walk test) between FAP patients after a liver transplant (4.1±2 months after transplant surgery) (FAPT) and a healthy group (HG).
Resumo:
The aims of this study is to examine the interest for quality of life of an implementation of program physical activity, with patients of multiple sclerosis.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Ressonância Magnética
Resumo:
We investigate whether firms’ economic and financial situation influence the Quality of their Financial Reports (FRQ). FRQ is fundamental for investors and it affects the international capital movements [Bradshaw et al. (2004)] and Gelos and Wei (2005)]. Following Schipper and Vicent (2003) we use two issues to access earnings quality: abnormal accruals and earnings persistence. For seventeen European countries, we find evidence that the economic performance affects FRQ. Big firms and those with high current earnings exhibit better financial information. These results are robust since they don’t depend on FRQ proxy and we have the same evidence when we estimate regression with economical and financial factors separately or together. About financial situation, it seems not to affect FRQ. However, in high leveraged firms, the capital structure becomes determinant.
Resumo:
Recently, companies developed strategies which may influence their Corporate Social Responsibility (CSR) image. This paper discusses the image of four different supermarkets with stores in Portugal. The research compares CSR image and brand attitude of the four supermarkets. Empirical evidence shows that different supermarkets belonging to the same company have different CSR image and brand attitude. The research also confirms that there is positive correlation between CSR image and attitude towards the brand. Further, the results offer empirical evidence that CSR image and brand attitude influence purchase intention of supermarket brands. Finally, brand purchase intention is highly influenced by attitude towards the brand than CSR image.
Resumo:
Introdução – A mamografia é o principal método de diagnóstico por imagem utilizado no rastreio e diagnóstico do cancro da mama, sendo a modalidade de imagem recomendada em vários países da Europa e Estados Unidos para utilização em programas de rastreio. A implementação da tecnologia digital causou alterações na prática da mamografia, nomeadamente a necessidade de adaptar os programas de controlo de qualidade. Objetivos – Caracterizar a tecnologia instalada para mamografia em Portugal e as práticas adotadas na sua utilização pelos profissionais de saúde envolvidos. Concluir sobre o nível de harmonização das práticas em mamografia em Portugal e a conformidade com as recomendações internacionais. Identificar oportunidades para otimização que permitam assegurar a utilização eficaz e segura da tecnologia. Metodologia – Pesquisa e recolha de dados sobre a tecnologia instalada, fornecidos por fontes governamentais, prestadores de serviços de mamografia e indústria. Construção de três questionários, orientados ao perfil do médico radiologista, técnico de radiologia com atividade em mamografia digital e técnico de radiologia coordenador. Os questionários foram aplicados em 65 prestadores de serviços de mamografia selecionados com base em critérios de localização geográfica, tipo de tecnologia instalada e perfil da instituição. Resultados – Foram identificados 441 sistemas para mamografia em Portugal. A tecnologia mais frequente (62%) e vulgarmente conhecida por radiografia computorizada (computed radiography) é constituída por um detector (image plate) de material fotoestimulável inserido numa cassete de suporte e por um sistema de processamento ótico. A maioria destes sistemas (78%) está instalada em prestadores privados. Aproximadamente 12% dos equipamentos instalados são sistemas para radiografia digital direta (Direct Digital Radiography – DDR). Os critérios para seleção dos parâmetros técnicos de exposição variam, observando-se que em 65% das instituições são adotadas as recomendações dos fabricantes do equipamento. As ferramentas de pós-processamento mais usadas pelos médicos radiologistas são o ajuste do contraste e brilho e magnificação total e/ou localizada da imagem. Quinze instituições (em 19) têm implementado um programa de controlo de qualidade. Conclusões – Portugal apresenta um parque de equipamentos heterogéneo que inclui tecnologia obsoleta e tecnologia “topo de gama”. As recomendações/guidelines (europeias ou americanas) não são adotadas formalmente na maioria das instituições como guia para fundamentação das práticas em mamografia, dominando as recomendações dos fabricantes do equipamento. Foram identificadas, pelos técnicos de radiologia e médicos radiologistas, carências de formação especializada, nomeadamente nas temáticas da intervenção mamária, otimização da dose e controlo da qualidade. A maioria dos inquiridos concorda com a necessidade de certificação da prática da mamografia em Portugal e participaria num programa voluntário. ABSTRACT - Introduction – Mammography is the gold standard for screening and imaging diagnosis of breast disease. It is the imaging modality recommended by screening programs in various countries in Europe and the United States. The implementation of the digital technology promoted changes in mammography practice and triggered the need to adjust quality control programs. Aims –Characterize the technology for mammography installed in Portugal. Assess practice in use in mammography and its harmonization and compliance to international guidelines. Identify optimization needs to promote an effective and efficient use of digital mammography to full potential. Methodology – Literature review was performed. Data was collected from official sources (governmental bodies, mammography healthcare providers and medical imaging industry) regarding the number and specifications of mammography equipment installed in Portugal. Three questionnaires targeted at radiologists, breast radiographers and the chief-radiographer were designed for data collection on the technical and clinical practices in mammography. The questionnaires were delivered in a sample of 65 mammography providers selected according to geographical criteria, type of technology and institution profile. Results – Results revealed 441 mammography systems installed in Portugal. The most frequent (62%) technology type are computerized systems (CR) mostly installed in the private sector (78%). 12% are direct radiography systems (DDR). The criteria for selection of the exposure parameters differ between the institutions with the majority (65%) following the recommendations from the manufacturers. The use of available tools for post-processing is limited being the most frequently reported tools used the contrast/ brightness and Zoom or Pan Magnification tools. Fifteen participant institutions (out of 19) have implemented a quality control programme. Conclusions – The technology for mammography in Portugal is heterogeneous and includes both obsolete and state of the art equipment. International guidelines (European or American) are not formally implemented and the manufacturer recommendations are the most frequently used guidance. Education and training needs were identified amongst the healthcare professionals (radiologists and radiographers) with focus in the areas of mammography intervention, patient dose optimization and quality control. The majority of the participants agree with the certification of mammography in Portugal.
Resumo:
Indoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide (CO) and carbon dioxide (CO2), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM10), and ozone (O3) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM10, O3, and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping.