1000 resultados para Illiac computer.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical characteristics of stirred curd were simultaneously monitored during syneresis in a 10-L cheese vat using computer vision and colorimetric measurements. Curd syneresis kinetic conditions were varied using 2 levels of milk pH (6.0 and 6.5) and 2 agitation speeds (12.1 and 27.2 rpm). Measured optical parameters were compared with gravimetric measurements of syneresis, taken simultaneously. The results showed that computer vision and colorimeter measurements have potential for monitoring syneresis. The 2 different phases, curd and whey, were distinguished by means of color differences. As syneresis progressed, the backscattered light became increasingly yellow in hue for circa 20 min for the higher stirring speed and circa 30 min for the lower stirring speed. Syneresis-related gravimetric measurements of importance to cheese making (e.g., curd moisture content, total solids in whey, and yield of whey) correlated significantly with computer vision and colorimetric measurements..

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The meltabilities of 14 process cheese samples were determined at 2 and 4 weeks after manufacture using sensory analysis, a computer vision method, and the Olson and Price test. Sensory analysis meltability correlated with both computer vision meltability (R-2 = 0.71, P < 0.001) and Olson and Price meltability (R-2 = 0.69, P < 0.001). There was a marked lack of correlation between the computer vision method and the Olson and Price test. This study showed that the Olson and Price test gave greater repeatability than the computer vision method. Results showed process cheese meltability decreased with increasing inorganic salt content and with lower moisture/fat ratios. There was very little evidence in this study to show that process cheese meltability changed between 2 and 4 weeks after manufacture..

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain-Computer Interfacing (BCI) has been previously demonstrated to restore patient communication, meeting with varying degrees of success. Due to the nature of the equipment traditionally used in BCI experimentation (the electroencephalograph) it is mostly conned to clinical and research environments. The required medical safety standards, subsequent cost of equipment and its application/training times are all issues that need to be resolved if BCIs are to be taken out of the lab/clinic and delivered to the home market. The results in this paper demonstrate a system developed with a low cost medical grade EEG amplier unit in conjunction with the open source BCI2000 software suite thus constructing the cheapest per electrode system available, meeting rigorous clinical safety standards. Discussion of the future of this technology and future work concerning this platform are also introduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although a number of studies have reported that force feedback gravity wells can improve performance in "point-and-click" tasks, there have been few studies addressing issues surrounding the use of gravity wells for multiple on-screen targets. This paper investigates the performance of users, both with and without motion-impairments, in a "point-and-click" task when an undesired haptic distractor is present. The importance of distractor location is studied explicitly. Results showed that gravity wells can still improve times and error rates, even on occasions when the cursor is pulled into a distractor. The greatest improvement is seen for the most impaired users. In addition to traditional measures such as time and errors, performance is studied in terms of measures of cursor movement along a path. Two cursor measures, angular distribution and temporal components, are proposed and their ability to explain performance differences is explored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

“Point and click” interactions remain one of the key features of graphical user interfaces (GUIs). People with motion-impairments, however, can often have difficulty with accurate control of standard pointing devices. This paper discusses work that aims to reveal the nature of these difficulties through analyses that consider the cursor’s path of movement. A range of cursor measures was applied, and a number of them were found to be significant in capturing the differences between able-bodied users and motion-impaired users, as well as the differences between a haptic force feedback condition and a control condition. The cursor measures found in the literature, however, do not make up a comprehensive list, but provide a starting point for analysing cursor movements more completely. Six new cursor characteristics for motion-impaired users are introduced to capture aspects of cursor movement different from those already proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

People with motion-impairments can often have difficulty with accurate control of standard pointing devices for computer input. The nature of the difficulties may vary, so to be most effective, methods of assisting cursor control must be suited to each user's needs. The work presented here involves a study of cursor trajectories as a means of assessing the requirements of motion-impaired computer users. A new cursor characteristic is proposed that attempts to capture difficulties with moving the cursor in a smooth trajectory. A study was conducted to see if haptic tunnels could improve performance in "point and click" tasks. Results indicate that the tunnels reduced times to target for those users identified by the new characteristic as having the most difficulty moving in a smooth trajectory. This suggests that cursor characteristics have potential applications in performing assessments of a user's cursor control capabilities which can then be used to determine appropriate methods of assistance.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: