988 resultados para INTERGROUP CONTACT


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The contact load-bearing response and surface damage resistance of multilayered hierarchical structured (MHSed) titanium were determined and compared to monolithic nanostructured titanium. The MHS structure was formed by combining cryorolling with a subsequent Surface Mechanical Attrition Treatment (SMAT) producing a surface structure consisted of an outer amorphous layer containing nanocrystals, an inner nanostructured layer and finally an ultra-fine grained core. The combination of a hard outer layer, a gradual transition layer and a compliant core results in reduced indentation depth, but a deeper and more diffuse sub-surface plastic deformation zone, compared to the monolithic nanostructured Ti. The redistribution of surface loading between the successive layers in the MHS Ti resulted in the suppression of cracking, whereas the monolithic nanograined (NG) Ti exhibited sub-surface cracks at the boundary of the plastic strain field. Finite element models with discrete layers and mechanically graded layersrepresenting the MHS system confirmed the absence of cracking and revealed a 38% decrease in shear stress in the sub-surface plastic strain field, compared to the monolithic NG Ti. Further, the mechanical gradation achieves a more gradual stress distribution which mitigates the interface failure and increases the interfacial toughness, thus providing strong resistance to loading damage. © 2014 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare subjective and objective visual performance of the Air Optix Aqua Multifocal lens to monovision in a group of subjects requiring a medium level of reading-addition power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dispersion state of individual MWCNT in the polymer matrix influences the mechanical, thermal, and electrical properties of the resulting composite. One method of obtaining a good dispersion state of MWCNT in a polymer matrix is to functionalize the surface of MWCNT using various treatments to enhance the surface energy and increase the dispersibility of MWCNT. In this study, wettability and surface energy of UV/Oand acid-treated multiwall carbon nanotubes (MWCNTs) and its polymethyl methacrylate (PMMA) polymer nanocomposites were measured using contact angle analysis in various solvent media. Contact angle analysis was based on ethylene glycol-water-glycerol probe liquid set and data was further fitted into geometric mean (Fowkes), van Oss-Chaudhury-Good (GvOC), and Chang-Qing-Chen (CQC) models to determine both nonpolar and acid base surface energy components. Analysis was conducted on MWCNT thin films subjected to different levels of UV/Oand acid treatments as well as their resulting MWCNT/PMMA nanocomposites. Contact angle analysis of thin films and nanocomposites revealed that the total surface energy of all samples was well fitted with each other. In addition, CQC model was able to determine the surface nature and polarity of MWCNT and its nanocomposites. Results indicated that the wettability changes in the thin film and its nanocomposites are due to the change in surface chemistry. Finally, electrical properties of nanocomposites were measured to investigate the effect of surface functionality (acid or basic) on the MWCNT surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

 This paper further the investigation of Doppler radar feasibility in measuring the flow in and out due to inhalation and exhalation under different conditions of breathing activities. Three different experiment conditions were designed to investigate the feasibility and consistency of Doppler radar which includes the combination of the states of normal breathing, deep breathing and apnoea state were demonstrated. The obtained Doppler radar signals were correlated and compared with the gold standard medical device, spirometer, yielding a good correlations between both devices. We also demonstrated the calibration of the Doppler radar signal can be performed in a simple manner in order to have a good agreements with the spirometer readings. The measurement of the flow in and out during the breathing activities can be measured accurately under different dynamics of breathing as long as the calibration is performed correctly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the ease with which children and youths without previous soft contact lens (SCL) experience were able to handle, care for, adapt and be fitted with SCLs. METHODS: 179 children aged 8-16 were recruited. Study visits included: screening and training visits, 1-week and 3-month follow-ups. During the training visit, the time taken to demonstrate proficiency in lens insertion and removal and care was recorded. A second training visit was scheduled if necessary. RESULTS: Nine children did not complete the screening visit and eight discontinued during the study. Of those eight, seven discontinued during the first week and one before the 3-month visit. Of those recruited, 90.5% (162/179) were successfully fitted and completed the study. A majority of children were dispensed with lenses at the first training visit (94.6%, 162/171). The mean training time for all children was 30min. There were no statistically significant differences in the number of lenses required to fit or instruction time by age group (p>0.05) or gender (p>0.05). Nine participants (5.3%, 9/171) required a second training visit with four still unable to handle lenses (2.3%, 4/171). By the 1-week visit 13.2% (22/167) of participants either lost or tore lenses, no subsequent lost or torn lenses occurred. No serious adverse events occurred during the study. CONCLUSION: Children and youths with no previous contact lens experience were easily fitted, able to successfully wear and care for lenses. The results of this study should encourage practitioners to recommend SCLs as a vision correction option.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To document contact lens prescribing patterns in the United States between 2002 and 2014. Methods A survey of contact lens prescribing trends was conducted each year between 2002 and 2014, inclusive. Randomly selected contact lens practitioners were asked to provide information relating to 10 consecutive contact lens fits between January and March each year. Results Over the 13-year survey period, 1650 survey forms were received from US practitioners representing details of 7702 contact lens fits. The mean (±SD) age of lens wearers was 33.6 (±15.2) years, of whom 65.2% were female. Rigid lens new fits decreased from 13.0% in 2002 to 9.4% in 2014. Across this period, silicone hydrogels have replaced mid water contact lens hydrogels as the soft lens material of choice. Toric lenses represented about 25 to 30% of all soft lens fits. Multifocal soft lenses are generally preferred to monovision. Daily disposable lens fits have recently increased, and in 2014, they represented 27.1% of all soft lens fits. Most lenses are prescribed on 1 to 2 weekly or monthly lens replacement regimen. Extended wear remains a minority lens wearing modality. The vast majority of those wearing reusable lenses use multipurpose lens care solutions. Lenses are mostly worn 7 d/wk. Conclusions This survey has revealed prescribing trends and preferences in the United States over the past 13 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Accelerometer peak impact accelerations are being used to measure player physical demands in contact sports. However, their accuracy to do so has not been ascertained. PURPOSE: To compare peak-impact-acceleration data from an accelerometer contained in a wearable tracking device with a 3-dimensional motion-analysis (MA) system during tackling and bumping. METHODS: Twenty-five semielite rugby athletes wore a tracking device containing a 100-Hz triaxial accelerometer (MinimaxX S4, Catapult Innovations, Australia). A single retroreflective marker was attached to the device, with its position recorded by a 12-camera MA system during 3 physical-collision tasks (tackle bag, bump pad, and tackle drill; N = 625). The accuracy, effect size, agreement, precision, and relative errors for each comparison were obtained as measures of accelerometer validity. RESULTS: Physical-collision peak impact accelerations recorded by the accelerometer overestimated (mean bias 0.60 g) those recorded by the MA system (P < .01). Filtering the raw data at a 20-Hz cutoff improved the accelerometer's relationship with MA data (mean bias 0.01 g; P > .05). When considering the data in 9 magnitude bands, the strongest relationship with the MA system was found in the 3.0-g or less band, and the precision of the accelerometer tended to reduce as the magnitude of impact acceleration increased. Of the 3 movements performed, the tackle-bag task displayed the greatest validity with MA. CONCLUSIONS: The findings indicate that the MinimaxX S4 accelerometer can accurately measure physical-collision peak impact accelerations when data are filtered at a 20-Hz cutoff frequency. As a result, accelerometers may be useful to measure physical collisions in contact sports.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous research has suggested that the presence of zoo visitors may be stressful for various primate species, and visual contact with visitors may be the sensory stimuli that mediate visitor effects. We studied a group of black-capped capuchins, Cebus apella, in a controlled experiment, randomly imposing two treatments: customised one-way vision screens on the exhibit viewing windows to reduce visual contact with visitors; and unmodified viewing windows that allow full visual contact with visitors. We sampled capuchin behaviour including intra-group aggression and other social interactions, vigilance and abnormal behaviours. To provide a measure of physiological stress, we also analysed capuchin faecal samples for glucocorticoid metabolite (FGM) concentration. When the view of visitors was obscured, we found marked reductions in capuchin aggression (from 14.5 bouts to 4.6 bouts per weekend, P= 0.004) and FGM concentration (from 620 to 410. ng/g, P= 0.008) among all adults, as well as reductions in abnormal behaviour (P = 0.01) in two individuals. The capuchins also avoided the visitor viewing area (P = 0.003) in the unmodified viewing window treatment. These results suggest that reducing the capuchins' ability to view visitors improved their welfare. However we also found a reduction in the number of visitors when visual contact was reduced (from an average of 23 visitors per scan to 15, P = 0.008), suggesting that the visitor experience may have been compromised by the lack of interaction with the capuchins. These results highlight a possible dilemma for the zoo industry between enhancing animal welfare in primates and providing for visitor experience.