996 resultados para Hydrogen breath test
Resumo:
Informe de l'anàlisi realitzat sobre el nou web de la Biblioteca Virtual de la UOC, per tal d'avaluar el grau d'usabilitat de la nova eina. És el segon test amb usuaris que es realitza del nou web i s'han analitzat els següents aspectes: l'accés a la col·lecció digital, les cinc funcionalitats més utilitzades del web i les cinc funcionalitats menys visibles del web.
Resumo:
N = 1 designs imply repeated registrations of the behaviour of the same experimental unit and the measurements obtained are often few due to time limitations, while they are also likely to be sequentially dependent. The analytical techniques needed to enhance statistical and clinical decision making have to deal with these problems. Different procedures for analysing data from single-case AB designs are discussed, presenting their main features and revising the results reported by previous studies. Randomization tests represent one of the statistical methods that seemed to perform well in terms of controlling false alarm rates. In the experimental part of the study a new simulation approach is used to test the performance of randomization tests and the results suggest that the technique is not always robust against the violation of the independence assumption. Moreover, sensitivity proved to be generally unacceptably low for series lengths equal to 30 and 40. Considering the evidence available, there does not seem to be an optimal technique for single-case data analysis
Resumo:
Tämä diplomityö on Lappeenrannan teknillisessä yliopistossa aloitetun kaasunpolttotutkimushankkeen ensimmäinen tutkimusjakso. Tutkimushanketta varten on LTY:n voimalaitostekniikan koepolttolaboratoriossa rakennettu kaasunpolton tutkimuslaitteisto, jolla tässä diplomityössä perehdytään kaasuliekin lämpötilan mittausmenetelmiin, lämmönsiirtoon ja syntyviin päästöihin neste- ja maakaasupoltossa. Hankkeen toisessa tutkimusjaksossa laitteistolla tutkitaan regenaratiivista polttoa, ja polttoaineena käytetään neste- ja maakaasun lisäksi muita kaasuja kuten vetyä ja erilaisia seoskaasuja. Kaasunpolttotutkimushankkeen kokonaistavoitteena on pienentää kaasunpoltossa syntyviä NOx-päästöjä ja parantaa palamishyötysuhdetta ja tätä kautta pienentää laitteiston kokoa ja vähentää hiilidioksidipäästöjä.
Resumo:
OBJECTIVE: This pilot experimental study tested the feasibility and intended effect of an educational intervention for parents to help them assist their adolescent child with chronic illness (CI) in becoming autonomous. METHODS: A two-phase pre-post pilot intervention study targeting parents of adolescents with CI was conducted. Parents were allocated to group 1 and 2 and received the four-module intervention consecutively. Intended effect was measured through online questionnaires for parents and adolescents before, at 2 months after, and at 4-6 months after the intervention. Feasibility was assessed through an evaluation questionnaire for parents. RESULTS: The most useful considered modules concerned the future of the adolescent and parents and social life. The most valued aspect was to exchange with other parents going through similar problems and receiving a new outlook on their relationship with their child. For parents, improvement trends appeared for shared management, parent protection, and self-efficacy, and worsening trends appeared for coping skills, parental perception of child vulnerability, and parental stress. For adolescents, improvement trends appeared for self-efficacy and parental bonding and worsening trends appeared for shared management and coping skills. CONCLUSION: Parents could benefit from peer-to-peer support and education as they support the needed autonomy development of their child. Future studies should test an online platform for parents to find peer support at all times and places.
Resumo:
Water is vital to humans and each of us needs at least 1.5 L of safe water a day to drink. Beginning as long ago as 1958 the World Health Organization (WHO) has published guidelines to help ensure water is safe to drink. Focused from the start on monitoring radionuclides in water, and continually cooperating with WHO, the International Standardization Organization (ISO) has been publishing standards on radioactivity test methods since 1978. As reliable, comparable and"fit for purpose" results are an essential requirement for any public health decision based on radioactivity measurements, international standards of tested and validated radionuclide test methods are an important tool for production of such measurements. This paper presents the ISO standards already published that could be used as normative references by testing laboratories in charge of radioactivity monitoring of drinking water as well as those currently under drafting and the prospect of standardized fast test methods in response to a nuclear accident.
Resumo:
BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
Resumo:
Oxidative stress is implicated in the pathogenesis of neurodegenerative disorders and hydrogen peroxide (H2O2) plays a central role in the stress. Huprines, a group of potent acetylcholinesterase inhibitors (AChEIs), have shown a broad cholinergic pharmacological profile. Recently, it has been observed that huprine X (HX) improves cognition in non transgenic middle aged mice and shows a neuroprotective activity (increased synaptophysin expression) in 3xTg-AD mice. Consequently, in the present experiments the potential neuroprotective effect of huprines (HX, HY, HZ) has been analyzed in two different in vitro conditions: undifferentiated and NGF-differentiated PC12 cells. Cells were subjected to oxidative insult (H2O2, 200 µM) and the protective effects of HX, HY and HZ (0.01 µM- 1 µM) were analyzed after a pre-incubation period of 24 and 48 hours. All huprines showed protective effects in both undifferentiated and NGF-differentiated cells, however only in differentiated cells the effect was dependent on cholinergic receptors as atropine (muscarinic antagonist, 0.1 µM) and mecamylamine (nicotinic antagonist, 100 µM) reverted the neuroprotection action of huprines. The decrease in SOD activity observed after oxidative insult was overcome in the presence of huprines and this effect was not mediated by muscarinic or nicotinic receptors. In conclusion, huprines displayed neuroprotective properties as previously observed in in vivo studies. In addition, these effects were mediated by cholinergic receptors only in differentiated cells. However, a non-cholinergic mechanism, probably through an increase in SOD activity, seems to be also involved in the neuroprotective effects of huprines.