926 resultados para High-power devices
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
TDEM survey in urban environmental for hydrogeological study at USP campus in Sao Paulo city, Brazil
Resumo:
In this work, some TDEM (Time Domain Electromagnetic) results at USP (University of Sao Paulo) campus in Sao Paulo city, Brazil, are presented. The data were acquired focusing on two mains objectives: (i) to map geoelectrical stratigraphy of Sao Paulo sedimentary basin, emphasizing on hydrogeological studies about sedimentary and crystalline aquifers, and (ii) to analyze the viability of TDEM data acquisition use in urban environment. The study area is located in Sao Paulo basin border, characterized by Resende and Sao Paulo formations, which are constituted by sand-clays sediments over a granite-gneissic basement. Two equipments were used in order to acquire database: Protem47 (low power), and Protem57-MK2 (high power). Capacitive noise affect obtained data with Protem47 due to the presence of metal pipes buried at IAG/USP (Institute of Astronomy, Geophysics, and Atmospheric Science) test site at USP. On the other hand, capacitive noise did not affect acquired data with Protem57-MK2, and the data present high signal to noise ratio. Surveys helped in determining sedimentary and crystalline aquifers, characterized by a fracture zone with water inside basin basement (conductive zone). Results show good agreement with local geology obtained from lithological boreholes located in the study areas. Moreover, it shows that TDEM method can be used in urban environments with a countless potential in hydrogeological studies, offering great reliability. Studies showed that main TDEM-method limitation at USP was the lack of space for opening the transmitter loop. Results are very promising and open new perspectives for TDEM-method use in urban environments as this area remains unexplored. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A new methodology for the synthesis of tunable patch filters is presented. The methodology helps the designer to perform a theoretical analysis of the filter through a coupling matrix that includes the effect of the tuning elements used to tune the filter. This general methodology accounts for any tuning parameter desired and was applied to the design of a tunable dual-mode patch filter with independent control of center frequency and bandwidth (BW). The bandpass filter uses a single triangular resonator with two etched slots that split the fundamental degenerate modes and form the filter passband. Varactor diodes assembled across the slots are used to vary the frequency of each degenerate fundamental mode independently, which is feasible due to the nature of the coupling scheme of the filter. The varactor diode model used in simulations, their assembling, the dc bias configuration, and measured results are presented. The theory results are compared to the simulations and to measurements showing a very good agreement and validating the proposed methodology. The fabricated filter presents an elliptic response with 20% of center frequency tuning range around 3.2 GHz and a fractional BW variation from 4% to 12% with low insertion loss and high power handling with a 1-dB compression point higher than +14.5 dB.
Resumo:
Introduction: Laser hair removal is becoming an increasingly popular alternative to traditional methods such as shaving, waxing, among other methods. Semiconductor diode lasers are considered the most efficient light sources available and are especially well suited for clinical applications including hair reduction. The effectiveness of laser hair reduction depends on many variables, including the skin type of the patient. Material and Methods: A patient with Fitzpatrick Skin Type IV was submitted to laser hair removal of the arms with a high-power diode laser system with long pulses with a wavelength of 800 nm, a fluence of 40 J/cm2 and a pulse width of 20 ms. A 12-month follow-up assessment was performed and included photography and questionnaire. Results: Hypopigmentation was observed after a single laser hair removal section. After 6 months with the area totally covered, a gradual suntan with a sun screen lotion with an SPF of 15 was prescribed by the dermatologist. After 12 months of the initial treatment, a complete recovery of the hypopigmentation was achieved. Conclusion: Although a safe procedure, lasers for hair removal may be associated with adverse side effects including undesired pigment alterations. Before starting a laser hair removal treatment, patients seeking the eradication of hair should be informed that temporary, and possibly permanent, pigmentary changes may occur.
Resumo:
The Department of Mechanical and Civil Engineering (DIMeC) of the University of Modena and Reggio Emilia is developing a new type of small capacity HSDI 2-Stroke Diesel engine (called HSD2), featuring a specifically designed combustion system, aimed to reduce weight, size and manufacturing costs, and improving pollutant emissions at partial load. The present work is focused on the analysis of the combustion and the scavenging process, investigated by means of a version of the KIVA-3V code customized by the University of Chalmers and modified by DIMeC. The customization of the KIVA-3V code includes a detailed combustion chemistry approach, coupled with a comprehensive oxidation mechanism for diesel oil surrogate and the modeling of turbulence/chemistry interaction through the PaSR (Partially Stirred Reactor) model. A four stroke automobile Diesel engine featuring a very close bore size is taken as a reference, for both the numerical models calibration and for a comparison with the 2-Stroke engine. Analysis is carried out trough a comparison between HSD2 and FIAT 1300 MultiJet in several operating conditions, at full and partial load. Such a comparison clearly demonstrates the effectiveness of the two stroke concept in terms of emissions reduction and high power density. However, HSD2 is still a virtual engine, and experimental results are needed to assume the reliability of numerical results.
Resumo:
The running innovation processes of the microwave transistor technologies, used in the implementation of microwave circuits, have to be supported by the study and development of proper design methodologies which, depending on the applications, will fully exploit the technology potentialities. After the choice of the technology to be used in the particular application, the circuit designer has few degrees of freedom when carrying out his design; in the most cases, due to the technological constrains, all the foundries develop and provide customized processes optimized for a specific performance such as power, low-noise, linearity, broadband etc. For these reasons circuit design is always a “compromise”, an investigation for the best solution to reach a trade off between the desired performances. This approach becomes crucial in the design of microwave systems to be used in satellite applications; the tight space constraints impose to reach the best performances under proper electrical and thermal de-rated conditions, respect to the maximum ratings provided by the used technology, in order to ensure adequate levels of reliability. In particular this work is about one of the most critical components in the front-end of a satellite antenna, the High Power Amplifier (HPA). The HPA is the main power dissipation source and so the element which mostly engrave on space, weight and cost of telecommunication apparatus; it is clear from the above reasons that design strategies addressing optimization of power density, efficiency and reliability are of major concern. Many transactions and publications demonstrate different methods for the design of power amplifiers, highlighting the availability to obtain very good levels of output power, efficiency and gain. Starting from existing knowledge, the target of the research activities summarized in this dissertation was to develop a design methodology capable optimize power amplifier performances complying all the constraints imposed by the space applications, tacking into account the thermal behaviour in the same manner of the power and the efficiency. After a reminder of the existing theories about the power amplifier design, in the first section of this work, the effectiveness of the methodology based on the accurate control of the dynamic Load Line and her shaping will be described, explaining all steps in the design of two different kinds of high power amplifiers. Considering the trade-off between the main performances and reliability issues as the target of the design activity, we will demonstrate that the expected results could be obtained working on the characteristics of the Load Line at the intrinsic terminals of the selected active device. The methodology proposed in this first part is based on the assumption that designer has the availability of an accurate electrical model of the device; the variety of publications about this argument demonstrates that it is so difficult to carry out a CAD model capable to taking into account all the non-ideal phenomena which occur when the amplifier operates at such high frequency and power levels. For that, especially for the emerging technology of Gallium Nitride (GaN), in the second section a new approach for power amplifier design will be described, basing on the experimental characterization of the intrinsic Load Line by means of a low frequency high power measurements bench. Thanks to the possibility to develop my Ph.D. in an academic spin-off, MEC – Microwave Electronics for Communications, the results of this activity has been applied to important research programs requested by space agencies, with the aim support the technological transfer from universities to industrial world and to promote a science-based entrepreneurship. For these reasons the proposed design methodology will be explained basing on many experimental results.
Resumo:
This thesis presents the outcomes of a Ph.D. course in telecommunications engineering. It is focused on the optimization of the physical layer of digital communication systems and it provides innovations for both multi- and single-carrier systems. For the former type we have first addressed the problem of the capacity in presence of several nuisances. Moreover, we have extended the concept of Single Frequency Network to the satellite scenario, and then we have introduced a novel concept in subcarrier data mapping, resulting in a very low PAPR of the OFDM signal. For single carrier systems we have proposed a method to optimize constellation design in presence of a strong distortion, such as the non linear distortion provided by satellites' on board high power amplifier, then we developed a method to calculate the bit/symbol error rate related to a given constellation, achieving an improved accuracy with respect to the traditional Union Bound with no additional complexity. Finally we have designed a low complexity SNR estimator, which saves one-half of multiplication with respect to the ML estimator, and it has similar estimation accuracy.
Resumo:
Die Resonanzionisations-Massenspektrometrie (RIMS) ist sowohl für spektroskopische Untersuchungen seltener Isotope als auch für den Ultraspurennachweis langlebiger radioaktiver Elemente einsetzbar. Durch die mehrstufige resonante Anregung atomarer Energieniveaus mit anschließender Ionisation mit Laserlicht wird eine sehr hohe Elementselektivität und Ionisationseffizienz erreicht. Der nachfolgende massenselektive Ionennachweis liefert eine gute Isotopenselektivität zusammen mit einer effektiven Untergrundunterdrückung. Ein wichtiger Bestandteil der RIMS-Apparatur ist ein zuverlässig arbeitendes, leistungsstarkes Lasersystem für die Resonanzionisation. Im Rahmen dieser Arbeit wurde ein von einem hochrepetierenden Nd:YAG-Laser gepumptes, aus drei Titan-Saphir-Lasern bestehendes System fertig aufgebaut und in den Routinebetrieb überführt. Die Titan-Saphir-Laser liefern im Durchstimmbereich von 730 - 880 nm eine mittlere Leistung von bis zu 3 W pro Laser bei einer Linienbreite von 2 - 3 GHz. Sie lassen sich computergesteuert in ihren Wellenlängen durchstimmen. Die mittels Resonanzionisation erzeugten Ionen werden dann in einem Flugzeit-Massenspektrometer entsprechend ihrer Masse aufgetrennt und mit einem Kanalplattendetektor nachgewiesen.Als Voraussetzung für die isotopenselektive Ultraspurenanalyse von Plutonium wurden mit diesem Lasersystem die Isotopieverschiebungen eines effizienten, dreistufigen Anregungsschema für Plutonium bestimmt. Die Laserleistungen reichen zur vielfachen Sättigung der ersten beiden Anregungsschritte und zur zweifachen Sättigung des dritten Anregungsschritts aus.Außerdem wurden die Ionisationsenergien von Pu-239 und Pu-244 zur Untersuchung ihrer Isotopenabhängigkeit bestimmt. Die beiden Ionisationsenergien sind im Rahmen der erreichten Genauigkeit bei einem Meßwert von IP239-IP244 = 0,24(82) cm^-1 gleich.Die Nachweiseffizienz der RIMS-Apparatur für Plutonium wurde in Effizienzmessungen zu 10^-5 bestimmt. Durch die gute Untergrundunterdrückung ergab sich daraus eine Nachweisgrenze von 10^6 Atomen bei der Messung eines Plutoniumisotops. Die Bestimmung der Isotopenverhältnisse von Proben mit einer zertifizierten Isotopenzusammensetzung lieferte eine gute Übereinstimmung der Meßwerte mit den angegebenen Zusammensetzungen.Die RIMS-Apparatur wurde zur Bestimmung des Gehalts und der Isotopenzusammensetzung von Plutonium in Meerwasser- und Staubproben eingesetzt.Auf Grund der Isotopenzusammensetzung konnte gezeigt werden, daß das Plutonium bei den meisten Proben aus dem Fallout von oberirdischen Kernwaffentests stammte. Des weiteren wurde Plutonium in Urinproben bestimmt. Die Nachweisgrenzen lagen bei diesen Umweltproben bei 10^6 bis 10^7 Atomen Plutonium und damit um zwei Größenordnungen niedriger als die Nachweisgrenze für Pu-239 bei der alpha-Spektroskopie, der Standardmethode für den Plutoniumnachweis.
Resumo:
The laser driven ion acceleration is a burgeoning field of resarch and is attracting a growing number of scientists since the first results reported in 2000 obtained irradiating thin solid foils by high power laser pulses. The growing interest is driven by the peculiar characteristics of the produced bunches, the compactness of the whole accelerating system and the very short accelerating length of this all-optical accelerators. A fervent theoretical and experimental work has been done since then. An important part of the theoretical study is done by means of numerical simulations and the most widely used technique exploits PIC codes (“Particle In Cell'”). In this thesis the PIC code AlaDyn, developed by our research group considering innovative algorithms, is described. My work has been devoted to the developement of the code and the investigation of the laser driven ion acceleration for different target configurations. Two target configurations for the proton acceleration are presented together with the results of the 2D and 3D numerical investigation. One target configuration consists of a solid foil with a low density layer attached on the irradiated side. The nearly critical plasma of the foam layer allows a very high energy absorption by the target and an increase of the proton energy up to a factor 3, when compared to the ``pure'' TNSA configuration. The differences of the regime with respect to the standard TNSA are described The case of nearly critical density targets has been investigated with 3D simulations. In this case the laser travels throughout the plasma and exits on the rear side. During the propagation, the laser drills a channel and induce a magnetic vortex that expanding on the rear side of the targer is source of a very intense electric field. The protons of the plasma are strongly accelerated up to energies of 100 MeV using a 200PW laser.
Resumo:
Lo studio presentato in questa sede concerne applicazioni di saldatura LASER caratterizzate da aspetti di non-convenzionalità ed è costituito da tre filoni principali. Nel primo ambito di intervento è stata valutata la possibilità di effettuare saldature per fusione, con LASER ad emissione continua, su pannelli Aluminum Foam Sandwich e su tubi riempiti in schiuma di alluminio. Lo studio ha messo in evidenza numerose linee operative riguardanti le problematiche relative alla saldatura delle pelli esterne dei componenti ed ha dimostrato la fattibilità relativa ad un approccio di giunzione LASER integrato (saldatura seguita da un post trattamento termico) per la realizzazione della giunzione completa di particolari tubolari riempiti in schiuma con ripristino della struttura cellulare all’interfaccia di giunzione. Il secondo ambito di intervento è caratterizzato dall’applicazione di una sorgente LASER di bassissima potenza, operante in regime ad impulsi corti, nella saldatura di acciaio ad elevato contenuto di carbonio. Lo studio ha messo in evidenza come questo tipo di sorgente, solitamente applicata per lavorazioni di ablazione e marcatura, possa essere applicata anche alla saldatura di spessori sub-millimetrici. In questa fase è stato messo in evidenza il ruolo dei parametri di lavoro sulla conformazione del giunto ed è stata definita l’area di fattibilità del processo. Lo studio è stato completato investigando la possibilità di applicare un trattamento LASER dopo saldatura per addolcire le eventuali zone indurite. In merito all’ultimo ambito di intervento l’attività di studio si è focalizzata sull’utilizzo di sorgenti ad elevata densità di potenza (60 MW/cm^2) nella saldatura a profonda penetrazione di acciai da costruzione. L’attività sperimentale e di analisi dei risultati è stata condotta mediante tecniche di Design of Experiment per la valutazione del ruolo preciso di tutti i parametri di processo e numerose considerazioni relative alla formazione di cricche a caldo sono state suggerite.
Resumo:
In dieser Arbeit wurde die Methode der resonanten Ionisation von neutralen Atomen mittels Laserstrahlung auf die leichten Aktinide Thorium, Uran, Neptunium und Plutonium angewendet und für die Ultraspurenanalyse optimiert. Der empfindliche Nachweis dieser Aktinide stellt eine Herausforderung für die Beobachtung und Bestimmung von radioaktiven Verunreinigungen aus kerntechnischen Anlagen in der Umwelt dar. In einem für diese Untersuchungen entwickelten Quadrupolmassenspektrometer konnte durch Resonanzionisationsspektroskopie jeweils eine Reihe unbekannter Energiezustände in der Elektronenhülle des neutralen Atoms der oben genannten Aktinide identifiziert, sowie effiziente Anregungsschemata für die resonante Ionisation entwickelt und charakterisiert werden. Durch die verwendete in-source-Ionisation, die aufgrund der guten Überlagerung von Laserstrahlung und Atomstrahl eine hohe Nachweiseffizienz gewährleistet, konnten diese Untersuchungen bereits mit einem, für Radionuklide notwendigen, geringen Probeneintrag erfolgen. Die resonante Ionisation erlaubt durch die selektiven resonanten Prozesse eine Unterdrückung unerwünschter Kontaminationen und wurde auf den analytischen Nachweis von Ultraspurengehalten in Umweltproben, sowie die Bestimmung der entsprechenden Isotopenzusammensetzung optimiert. Durch die effiziente in-source-Ionisation mit leistungsstarker gepulster Laserstrahlung, konnten Nachweiseffizienzen im Bereich von bis zu 1% erreicht werden. Dabei wurden für Plutonium in synthetischen Proben, aber auch in ersten Umweltproben, Nachweisgrenzen von 10^4-10^5 Atomen erzielt. Die Verwendung spektral schmalbandiger Dauerstrichlaser und eine Ionisation transversal zum frei propagierenden Atomstrahl ermöglicht durch Auflösung der Isotopieverschiebung eine hohe Selektivität gegenüber dominanten Nachbarisotopen, wohingegen die Ionisationseffizienz deutlich abnimmt. Hiermit konnte für das Ultraspurenisotop U-236 eine Nachweisgrenze bis hinab zu 10^-9 für das Isotopenverhältnis N(U-236)/N(U-238) bestimmt werden.