929 resultados para High, Peter S.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: During histoplasmosis, Histoplasma capsulatum soluble antigens (CFAg) can be naturally released by yeast cells. Because CFAg can be specifically targeted during infection, in the present study we investigated CFAg release in experimental murine histoplasmosis, and evaluated the host humoral immune response against high-molecular-mass antigens (hMMAg. >150 kDa), the more immunogenic CFAg fraction. METHODS: Mice were infected with 2.2x10(4) H. capsulatum IMT/HC128 yeast cells. The soluble CFAg, IgG anti-CFAg, IgG anti-hMMAg, and IgG-hMMAg circulating immune complexes (CIC) levels were determined by enzymelinked immunosorbent assay, at days 0, 7, 14, and 28 post-infection. RESULTS: We observed a progressive increase in circulating levels of CFAg, IgG anti-CFAg, IgG anti-hMMAg, and IgG-hMMAg CIC after H. capsulatum infection. The hMMAg showed a high percentage of carbohydrates and at least two main immunogenic components. CONCLUSIONS: We verified for the first time that hMMAg from H. capsulatum IMT/HC128 strain induce humoral immune response and lead to CIC formation during experimental histoplasmosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper was prepared for the course “Project III”, with the supervision of Prof. António Moniz, reporting on the author speaking notes at the Winter School on Technology Assessment, 6-7 December 2010, as part of the Doctoral Programme on Technology Assessment at FCT-UNL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics and Maastricht University School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study evaluated the level of concordance between hybrid capture II (HCII) and PapilloCheck® for the detection of high-risk human papillomavirus (HPV) in anal samples. Methods Anal cell samples collected from 42 human immunodeficiency virus (HIV)+ patients were analyzed. Results Considering only the 13 high-risk HPV types that are detectable by both tests, HCII was positive for 52.3% of the samples, and PapilloCheck® was positive for 52.3%. The level of concordance was 80.9% (Kappa = 0.61). Conclusions Good concordance was observed between the tests for the detection of high-risk HPV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project has two different goals, one of them is to promote the consumption of exotic fruits with high quality. The other goal of the project is to look for the viability of turning this work project into a real business, focusing in two different channels to diversify its revenues: B2B and B2C. In order to achieve this second goal, this project aims to see the best way to commercialize this product (Lucuma powder and Pulp of Lucuma) and how to make it in an efficient way with right companies. Therefore, the project aims to create a company to commercialize the product between the producers in Peru and possibly small businesses interested in acquire the processed fruit and also individuals interested in own consumption in small quantities. This project, if successful, tries to diversify the consumption into other good organic healthy products in the long-term.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Nine cases of visceral leishmaniasis occurred recently in Barra Mansa, State of Rio de Janeiro, with a high mortality rate. Methods We reviewed the medical records of the patients. Results Eight were male; 7 were adults. Patients who died progressed to death quickly and presented with aggravating factors: systemic steroid therapy before diagnosis, bleeding, severe liver involvement, infection, and/or refusal to receive transfusion. Conclusions We warn clinicians to be aware of the emergence of visceral leishmaniasis in new areas and to keep in mind the possibility of atypical clinical pictures and aggravating factors, so timely diagnosis can be made and prompt and adequate treatment can be initiated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IntroductionDetermining the genetic similarities among Trypanosoma cruzi populations isolated from different hosts and vectors is very important to clarify the epidemiology of Chagas disease.MethodsAn epidemiological study was conducted in a Brazilian endemic area for Chagas disease, including 76 chronic chagasic individuals (96.1% with an indeterminate form; 46.1% with positive hemoculture).ResultsT. cruzi I (TcI) was isolated from one child and TcII was found in the remaining (97.1%) subjects. Low-stringency single-specific-primer-polymerase chain reaction (LSSP-PCR) showed high heterogeneity among TcII populations (46% of shared bands); however, high similarities (80-100%) among pairs of mothers/children, siblings, or cousins were detected.ConclusionsLSSP-PCR showed potential for identifying similar parasite populations among individuals with close kinship in epidemiological studies of Chagas disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The association of lymphoma with necrotic granuloma can pose diagnostic challenges and delay treatment, especially in settings with a high burden of infection. In these settings, the timely use of cytogenetic and molecular methods is most relevant. Here, we report a case of B-cell lymphoma with t (8;14) in a 5-year-old male child. The lymphoma was associated with necrotic granuloma and was initially misdiagnosed as tuberculosis. Polymerase chain reaction was used to detect clonal lymphoproliferation and to rule out Mycobacterium tuberculosis infection. Tumor cells harbored Epstein-Barr virus and expressed CD20, CD10, BCL6, and Ki67 (30%), leading to the diagnosis of B-cell lymphoma with features intermediate between diffuse large B-cell lymphoma and Burkitt lymphoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: INTRODUCTION: The World Health Organization endorses the BACTEC Mycobacterial Growth Indicator Tube (MGIT)(tm) system as a rapid, sensitive, and specific method to diagnostic of tuberculosis. Here, we compared the performance of this system against Ogawa-Kudoh cultures and microscopy. METHODS: A total of 927 samples were obtained between December 2011 and December 2013 from 652 cases of suspected tuberculosis at the School Hospital of the Federal University of Rio Grande in Brazil. RESULTS: The MGIT system confirmed tuberculosis in more cases in less time. CONCLUSIONS: The MGIT system is an effective tool for early diagnosis of tuberculosis, especially in patients with HIV/AIDS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aims of this study were to evaluate the role of high resolution computed tomography of the torax in detecting abnormalities in chronic asthmatic patients and to determine the behavior of these lesions after at least one year. METHOD: Fourteen persistent asthmatic patients with a mean forced expiratory volume in 1-second that was 63% of predicted and a mean forced expiratory volume in 1-second /forced vital capacity of 60% had two high resolution computed tomographys separated by an interval of at least one year. RESULTS: All 14 patients had abnormalities on both scans. The most common abnormality was bronchial wall thickening, which was present in all patients on both computed tomographys. Bronchiectasis was suggested on the first computed tomography in 5 of the 14 (36%) patients, but on follow-up, the bronchial dilatation had disappeared in 2 and diminished in a third. Only one patient had any emphysematous changes; a minimal persistent area of paraseptal emphysema was present on both scans. In 3 patients, a "mosaic" appearance was observed on the first scan, and this persisted on the follow-up computed tomography. Two patients had persistent areas of mucoid impaction. In a third patient, mucus plugging was detected only on the second computed tomography. CONCLUSIONS: We conclude that there are many abnormalities on the high resolution computed tomography of patients with persistent asthma. Changes suggestive of bronchiectasis, namely bronchial dilatation, frequently resolve spontaneously. Therefore, the diagnosis of bronchiectasis by high resolution computed tomography in asthmatic patients must be made with caution, since bronchial dilatation can be reversible or can represent false dilatation. Nonsmoking chronic asthmatic subjects in this study had no evidence of centrilobular or panacinar emphysema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many municipal activities require updated large-scale maps that include both topographic and thematic information. For this purpose, the efficient use of very high spatial resolution (VHR) satellite imagery suggests the development of approaches that enable a timely discrimination, counting and delineation of urban elements according to legal technical specifications and quality standards. Therefore, the nature of this data source and expanding range of applications calls for objective methods and quantitative metrics to assess the quality of the extracted information which go beyond traditional thematic accuracy alone. The present work concerns the development and testing of a new approach for using technical mapping standards in the quality assessment of buildings automatically extracted from VHR satellite imagery. Feature extraction software was employed to map buildings present in a pansharpened QuickBird image of Lisbon. Quality assessment was exhaustive and involved comparisons of extracted features against a reference data set, introducing cartographic constraints from scales 1:1000, 1:5000, and 1:10,000. The spatial data quality elements subject to evaluation were: thematic (attribute) accuracy, completeness, and geometric quality assessed based on planimetric deviation from the reference map. Tests were developed and metrics analyzed considering thresholds and standards for the large mapping scales most frequently used by municipalities. Results show that values for completeness varied with mapping scales and were only slightly superior for scale 1:10,000. Concerning the geometric quality, a large percentage of extracted features met the strict topographic standards of planimetric deviation for scale 1:10,000, while no buildings were compliant with the specification for scale 1:1000.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We tested the role of frozen section examination of the cone specimen in the evaluation of the resection margin status and to rule out invasion in patients with high-grade cervical intraepithelial neoplasia. METHODS: Twenty-five patients with cervical intraepithelial neoplasia underwent conization followed by frozen section examination and planned hysterectomy. The results of the definitive paraffin exam were compared with frozen section examination. RESULTS: In the evaluation of the margins by frozen section examination, 16 patients (64%) had positive cone margins and 9 (36%) had negative margins. The definitive paraffin examination of margin status was concordant in all the cases. Intraoperative diagnosis of invasion was made in 5 cases, and 1 of these was microinvasive. Among the remaining 20 cases, we detected 2 additional microinvasive carcinomas after paraffin study, so the diagnosis of the frozen section examination was concordant with the paraffin sections in 23/25 cases (92%). Two cases of microinvasive carcinoma were diagnosed as cervical intraepithelial neoplasia by frozen section examination and had less than 2 mm stromal invasion. CONCLUSIONS: In high-grade cervical intraepithelial neoplasia, frozen section examination can provide immediate and precise evaluation of the cone margin status in high-grade cervical intraepithelial neoplasia. It can identify frank invasion and permit adequate treatment in a one-stage procedure. In early microinvasive disease, frozen section examination fails to detect the area of invasion but reliably detects clear resection margins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of AC losses in superconducting pancake coils is of utmost importance for the development of superconducting devices. Due to different technical difficulties this study is usually performed considering one of two approaches: considering superconducting coils of few turns and studying AC losses in a large frequency range vs. superconducting coils with a large number of turns but measuring AC losses only in low frequencies. In this work, a study of AC losses in 128 turn superconducting coils is performed, considering frequencies ranging from 50 Hz till 1152 Hz and currents ranging from zero till the critical current of the coils. Moreover, the study of AC losses considering two different simultaneous harmonic components is also performed and results are compared to the behaviour presented by the coils when operating in a single frequency regime. Different electrical methods are used to verify the total amount of AC losses in the coil and a simple calorimetric method is presented, in order to measure AC losses in a multi-harmonic context. Different analytical and numerical methods are implemented and/or used, to design the superconducting coils and to compute the total amount of AC losses in the superconducting system and a comparison is performed to verify the advantages and drawbacks of each method.