932 resultados para Heat pump, Solar Energy, Ambient Energy, Evaporator Collector, Collector Efficiency
Resumo:
The need for renewable energy sources, facing the consequences of Climate Change, results in growing investment for solar collectors use. Research in this field has accompanied this expansion and evacuated tube solar collector stands as an important study focus. Thus, several works have been published for representing the stratification of the fluid inside the tubes and the reservoir, as well as analytical modeling for the heat flow problem. Based on recent publications, this paper proposes the study of solar water heating with evacuated tubes, their operation characteristics and operating parameters. To develop this work, a computational tool will be used - in this case, the application of computational fluid dynamics (CFD) software. In possession of the implemented model, a numerical simulation will be performed to evaluate the behavior of the fluid within this solar collector and possible improvements to be applied in the model.
Resumo:
This thesis develops an effective modeling and simulation procedure for a specific thermal energy storage system commonly used and recommended for various applications (such as an auxiliary energy storage system for solar heating based Rankine cycle power plant). This thermal energy storage system transfers heat from a hot fluid (termed as heat transfer fluid - HTF) flowing in a tube to the surrounding phase change material (PCM). Through unsteady melting or freezing process, the PCM absorbs or releases thermal energy in the form of latent heat. Both scientific and engineering information is obtained by the proposed first-principle based modeling and simulation procedure. On the scientific side, the approach accurately tracks the moving melt-front (modeled as a sharp liquid-solid interface) and provides all necessary information about the time-varying heat-flow rates, temperature profiles, stored thermal energy, etc. On the engineering side, the proposed approach is unique in its ability to accurately solve both individually and collectively all the conjugate unsteady heat transfer problems for each of the components of the thermal storage system. This yields critical system level information on the various time-varying effectiveness and efficiency parameters for the thermal storage system.
Resumo:
Polysilicon cost impacts significantly on the photovoltaics (PV) cost and on the energy payback time. Nowadays, the besetting production process is the so called Siemens process, polysilicon deposition by chemical vapor deposition (CVD) from Trichlorosilane. Polysilicon purification level for PV is to a certain extent less demanding that for microelectronics. At the Instituto de Energa Solar (IES) research on this subject is performed through a Siemens process-type laboratory reactor. Through the laboratory CVD prototype at the IES laboratories, valuable information about the phenomena involved in the polysilicon deposition process and the operating conditions is obtained. Polysilicon deposition by CVD is a complex process due to the big number of parameters involved. A study on the influence of temperature and inlet gas mixture composition on the polysilicon deposition growth rate, based on experimental experience, is shown. Moreover, CVD process accounts for the largest contribution to the energy consumption of the polysilicon production. In addition, radiation phenomenon is the major responsible for low energetic efficiency of the whole process. This work presents a model of radiation heat loss, and the theoretical calculations are confirmed experimentally through a prototype reactor at our disposal, yielding a valuable know-how for energy consumption reduction at industrial Siemens reactors.
Resumo:
Many efforts have been made in order to adequate the production of a solar thermal collector field to the consumption of domestic hot water of the inhabitants of a building. In that sense, much has been achieved in different domains: research agencies, government policies and manufacturers. However, most of the design rules of the solar plants are based on steady state models, whereas solar irradiance, consumption and thermal accumulation are inherently transient processes. As a result of this lack of physical accuracy, thermal storage tanks are sometimes left to be as large as the designer decides without any aforementioned precise recommendation. This can be a problem if solar thermal systems are meant to be implemented in nowadays buildings, where there is a shortage of space. In addition to that, an excessive storage volume could not result more efficient in many residential applications, but costly, extreme in space consumption and in some cases too heavy. A proprietary transient simulation program has been developed and validated with a detailed measurement campaign in an experimental facility. In situ environmental data have been obtained through a whole year of operation. They have been gathered at intervals of 10 min for a solar plant of 50 m2 with a storage tank of 3 m3, including the equipment for domestic hot water production of a typical apartment building. This program has been used to obtain the design and dimensioning criteria of DHW solar plants under daily transient conditions throughout a year and more specifically the size of the storage tank for a multi storey apartment building. Comparison of the simulation results with the current Spanish regulation applicable, Cdigo Tcnico de la Edificacin (CTE 2006), offers fruitful details and establishes solar facilities dimensioning criteria.
Resumo:
La perdiz roja es la especie cinegtica por excelencia en la pennsula ibrica, cuya cra en cautividad y suelta controlada comenz a regularse en los aos 70 con la aparicin del ICONA. La incubacin controlada de huevos de perdiz es imprescindible, con fines cinegticos y de preservacin de la especie, y se desarrolla con incubadoras comerciales de pequea y mediana escala, distribuidas en zonas rurales con acceso limitado y/o deficiente al suministro elctrico. En nuestras latitudes el aporte de energa solar trmica se perfila como una posibilidad de mejorar la eficiencia energtica de stas y otras instalaciones y de reducir la dependencia energtica exterior. Hay diversos factores fsico-qumicos que influyen en la calidad de la incubacin: temperatura, humedad relativa, y concentracin de gases, de los cuales slo los dos primeros son habitualmente supervisados y controlados en este tipo de incubadoras. Esta Tesis surge en el marco de dos proyectos de cooperacin con la AECID, y tiene como objetivos: la caracterizacin espacial de variables relevantes (temperatura (T), humedad relativa (HR)) en la incubadora comercial durante el proceso de incubacin, la determinacin de la relacin existente entre la evolucin de variables ambientales durante el proceso de incubacin y la tasa de nacimientos (35-77%), as como el diseo y evaluacin del sistema de apoyo solar trmico para determinar su potencial de utilizacin durante las incubaciones comerciales. La instalacin de un nmero limitado de sensores permite la monitorizacin precisa del proceso de incubacin de los huevos. Los resultados ms relevantes indican que en incubaciones comerciales los gradientes de T y HR han sido despreciables (1C de diferencia entre las posiciones con mayor y menor T media y un 4,5% de diferencia entre las posiciones con mayor y menor HR), mientras que el seguimiento y ajuste (mediante modelos de crecimiento) de la concentracin de CO2 (r2 entre 0,948 y 0,987 en las 5 incubaciones, para un total de 43315 huevos) permite valorar la actividad fisiolgica de los huevos e incluso predecir la tasa de xito (nacimientos), basndose en la concentracin de CO2 estimada mediante modelos de crecimiento en el da 20 de incubacin (r2 entre 0,997 y 0,994 segn el modelo de estimacin empleado). El sistema ha sido valorado muy positivamente por los productores (Finca Cinegtica Dehesa Vieja de Galapagar). El aporte trmico se ha diseado (con mnima intrusin en el sistema comercial) sobre la base de un sistema de enfriamiento de emergencia original de la incubadora, al que se han incorporado un colector solar, un depsito, un sistema de electrovlvulas, una bomba de circulacin y sensores de T en distintos puntos del sistema, y cuyo control ha sido automatizado. En esta Tesis se muestra que la contribucin solar puede aportar hasta un 42% de las demandas de energa en nuestras condiciones geogrficas para una temperatura de consigna dentro de la incubadora de 36.8C, sin afectar a la estabilidad de la temperatura. Adems, el rendimiento del colector solar se ha acotado entre un 44% y un 85%, de acuerdo con los clculos termodinmicos; valores que se mantienen dentro del rango aportado por el fabricante (61%). En el futuro se plantea evaluar el efecto de distintas estrategias de control, tales como controladores difusos, que incorporan el conocimiento experto al control automtico. ABSTRACT The partridge is the quintessential game species in the Iberian Peninsula, which controlled breeding and release, began to be regulated in the 70s with the emergence of ICONA. The controlled incubation of eggs is essential, and takes place in commercial incubators of small and medium scale, distributed in rural areas with limited and/or inadequate access to power. In our latitudes the contribution of solar thermal energy is emerging as a possibility to improve the energy efficiency of the facilities and to reduce external energy dependence. There are various physicochemical factors influencing the quality of incubation: temperature, relative humidity and concentration of gases, of which only the first two are typically monitored and controlled in such incubators. This PhD comes within the framework of two cooperation projects with AECID and aims: the spatial characterization of relevant variables in a commercial incubator (temperature (T), and relative humidity (HR)), determining the relationships in the changes in environmental variables during incubation and birth rates (35-77%) as well as the design and evaluation of solar thermal support system to determine its potential use during commercial incubations; the installation of a limited number of sensors has allowed accurate monitoring of incubation of eggs. The most relevant results indicate that in commercial incubations, the gradients in T and HR have been negligible (1C difference between the highest and lowest positions T and average 4.5% difference between the highest and lowest positions HR), while monitoring and fit using growth models of the concentration of CO2 (r2 between 0.948 and 0.987 in 5 incubations, for a total amount of 43,315 eggs) allows assessing the physiological activity of the eggs and even predict the success rate (hatchability), based on the estimated concentration of CO2 by using growth models on day 20 of incubation (r2 between 0.997 and 0.994 depending on the fit model).The system has been highly valued by producers (Finca Cinegtica Dehesa Vieja de Galapagar). The hybrid heat system is designed (with minimal intrusion into the commercial system) based on an emergency cooling device, original in the incubator. New elements have been incorporated: a solar collector, a tank, a system of solenoid valves, a circulating pump and T sensors at various points of the system, whose control has been automated. This PhD shows that the solar contribution is responsible for up to 42% of energy demands in our geographical conditions for a setpoint temperature inside the incubator of 36.8C, without questioning the stability of the temperature. Furthermore, the efficiency of the solar collector has been bounded between 44% and 85%, according to thermodynamic calculations; values remain within the range provided by the manufacturer (61%). In the future it is proposed to evaluate the effect of different control strategies, such as fuzzy controllers, which incorporate the expertise to automated control.
Resumo:
A conceptual energy storage system design that utilizes ultra high temperature phase change materials is presented. In this system, the energy is stored in the form of latent heat and converted to electricity upon demand by TPV (thermophotovoltaic) cells. Silicon is considered in this study as PCM (phase change material) due to its extremely high latent heat (1800 J/g or 500 Wh/kg), melting point (1410 C), thermal conductivity (~25 W/mK), low cost (less than $2/kg or $4/kWh) and abundance on earth. The proposed system enables an enormous thermal energy storage density of ~1 MWh/m3, which is 10e20 times higher than that of lead-acid batteries, 2e6 times than that of Li-ion batteries and 5e10 times than that of the current state of the art LHTES systems utilized in CSP (concentrated solar power) applications. The discharge efficiency of the system is ultimately determined by the TPV converter, which theoretically can exceed 50%. However, realistic discharge efficiencies utilizing single junction TPV cells are in the range of 20e45%, depending on the semiconductor bandgap and quality, and the photon recycling efficiency. This concept has the potential to achieve output electric energy densities in the range of 200-450 kWhe/m3, which is comparable to the best performing state of the art Lithium-ion batteries.
Resumo:
This study is an attempt at achieving Net Zero Energy Building (NZEB) using a solar Organic Rankine Cycle (ORC) based on exergetic and economic measures. The working fluid, working conditions of the cycle, cycle configuration, and solar collector type are considered the optimization parameters for the solar ORC system. In the first section, a procedure is developed to compare ORC working fluids based on their molecular components, temperature-entropy diagram and fluid effects on the thermal efficiency, net power generated, vapor expansion ratio, and exergy efficiency of the Rankine cycle. Fluids with the best cycle performance are recognized in two different temperature levels within two different categories of fluids: refrigerants and non-refrigerants. Important factors that could lead to irreversibility reduction of the solar ORC are also investigated in this study. In the next section, the system requirements needed to maintain the electricity demand of a geothermal air-conditioned commercial building located in Pensacola of Florida is considered as the criteria to select the optimal components and optimal working condition of the system. The solar collector loop, building, and geothermal air conditioning system are modeled using TRNSYS. Available electricity bills of the building and the 3-week monitoring data on the performance of the geothermal system are employed to calibrate the simulation. The simulation is repeated for Miami and Houston in order to evaluate the effect of the different solar radiations on the system requirements. The final section discusses the exergoeconomic analysis of the ORC system with the optimum performance. Exergoeconomics rests on the philosophy that exergy is the only rational basis for assigning monetary costs to a systems interactions with its surroundings and to the sources of thermodynamic inefficiencies within it. Exergoeconomic analysis of the optimal ORC system shows that the ratio Rex of the annual exergy loss to the capital cost can be considered a key parameter in optimizing a solar ORC system from the thermodynamic and economic point of view. It also shows that there is a systematic correlation between the exergy loss and capital cost for the investigated solar ORC system.
Resumo:
The Z-scan and thermal-lens techniques have been used to obtain the energy transfer upconversion parameter in Nd(3+)-doped materials. A comparison between these methods is done, showing that they are independent and provide similar results. Moreover, the advantages and applicability of each one are also discussed. The results point to these approaches as valuable alternative methods because of their sensitivity, which allows measurements to be performed in a pump-power regime without causing damage to the investigated material. (C) 2009 Optical Society of America
Resumo:
The end consumers in a smart grid context are seen as active players. The distributed generation resources applied in smart home system as a micro and small-scale systems can be wind generation, photovoltaic and combine heat and power facility. The paper addresses the management of domestic consumer resources, i.e. wind generation, solar photovoltaic, combined heat and power, electric vehicle with gridable capability and loads, in a SCADA system with intelligent methodology to support the user decision in real time. The main goal is to obtain the better management of excess wind generation that may arise in consumers distributed generation resources. The optimization methodology is performed in a SCADA House Intelligent Management context and the results are analyzed to validate the SCADA system.
Resumo:
Companies and researchers involved in developing miniaturized electronic devices face the basic problem of the needed batteries size, finite life of time and environmental pollution caused by their final deposition. The current trends to overcome this situation point towards Energy Harvesting technology. These harvesters (or scavengers) store the energy from sources present in the ambient (as wind, solar, electromagnetic, etc) and are costless for us. Piezoelectric devices are the ones that show a higher power density, and materials as ceramic PZT or polymeric PVDF have already demonstrated their ability to act as such energy harvester elements. Combinations between piezoelectric and electromagnetic mechanism have been also extensively investigated. Nevertheless, the power generated by these combinations is limited under the application of small magnetic fields, reducing the performance of the energy harvester [1]. In the last years the appearance of magnetoelectric (ME) devices, in which the piezoelectric deformation is driven by the magnetostrictive element, enables to extract the energy of very small electromagnetic signals through the generated magnetoelectric voltage at the piezoelectric element. However, very little work has been done testing PVDF polymer as piezoelectric constituent of the ME energy harvester device, and only to be proposed as a possibility of application [2]. Among the advantages of using piezopolymers for vibrational energy harvesting we can remember that they are ductile, resilient to shock, deformable and lightweight. In this work we demonstrate the feasibility of using magnetostrictive Fe-rich magnetic amorphous alloys/piezoelectric PVDF sandwich-type laminated ME devices as energy harvesters. A very simple experimental set-up will show how these laminates can extract energy, in amounts of W, from an external AC field.
Resumo:
Energy management is the process of monitoring, controlling and conserving energy in a building or organisation. The main reasons for this are for cost purposes and benefit to the environment. Through various techniques and solutions for lighting, heating, office equipment, the building fabric etc along with a change in peoples attitudes there can be a substantial saving in the amount spent on energy. A good example o f energy waste in GMIT is the lighting situation in the library. All the lights are switched on all day on even in places where that is adequate daylighting, which is a big waste o f energy. Also the lights for book shelves are left on. Surely all these books wont be searched for all at the one time. It would make much more sense to have local switches that the users can control when they are searching for a particular book. Heating controls for the older parts o f the college are badly needed. A room like 834 needs a TRV to prevent it from overheating as temperatures often reach the high twenties due to the heat from the radiators, computers, solar gains and heat from users o f the room. Also in the old part o f the college it is missing vital insulation, along with not being air tight due to the era when it was built. Pumped bonded bead insulation and sealant around services and gaps can greatly improve the thermal performance o f the building and help achieve a higher BER cert. GMIT should also look at the possibility o f installing a CHP plant to meet the base heating loads. It would meet the requirement o f running 4500 hours a year and would receive some financial support from the Accelerated Capital Allowance. I f peoples attitudes are changed through energy awareness campaigns and a few changes made for more energy efficient equipment, substantial savings can be made in the energy expenditure.
Resumo:
Driven by concerns about rising energy costs, security of supply and climate change a new wave of Sustainable Energy Technologies (SETs) have been embraced by the Irish consumer. Such systems as solar collectors, heat pumps and biomass boilers have become common due to government backed financial incentives and revisions of the building regulations. However, there is a deficit of knowledge and understanding of how these technologies operate and perform under Irelands maritime climate. This AQ-WBL project was designed to address both these needs by developing a Data Acquisition (DAQ) system to monitor the performance of such technologies and a web-based learning environment to disseminate performance characteristics and supplementary information about these systems. A DAQ system consisting of 108 sensors was developed as part of Galway-Mayo Institute of Technologys (GMITs) Centre for the Integration of Sustainable EnergyTechnologies (CiSET) in an effort to benchmark the performance of solar thermal collectors and Ground Source Heat Pumps (GSHPs) under Irish maritime climate, research new methods of integrating these systems within the built environment and raise awareness of SETs. It has operated reliably for over 2 years and has acquired over 25 million data points. Raising awareness of these SETs is carried out through the dissemination of the performance data through an online learning environment. A learning environment was created to provide different user groups with a basic understanding of a SETs with the support of performance data, through a novel 5 step learning process and two examples were developed for the solar thermal collectors and the weather station which can be viewed at http://www.kdp 1 .aquaculture.ie/index.aspx. This online learning environment has been demonstrated to and well received by different groups of GMITs undergraduate students and plans have been made to develop it further to support education, awareness, research and regional development.
Resumo:
Magdeburg, Univ., Fak. fr Verfahrens- und Systemtechnik, Diss., 2011
Resumo:
This thesis analyses the calculation of FanSave and PumpSave energy saving tools calculation. With these programs energy consumption of variable speed drive control for fans and pumps can be compared to other control methods. With FanSave centrifugal and axial fans can be examined and PumpSave deals with centrifugal pumps. By means of these programs also suitable frequency converter can be chosen from the ABB collection. Programs need as initial values information about the appliances like amount of flow and efficiencies. Operation time is important factor when calculating the annual energy consumption and information about it are the length and profile. Basic theory related to fans and pumps is introduced without more precise instructions for dimensioning. FanSave and PumpSave contain various methods for flow control. These control methods are introduced in the thesis based on their operational principles and suitability. Also squirrel cage motor and frequency converter are introduced because of their close involvement to fans and pumps. Second part of the thesis contains comparison between results of FanSaves and PumpSaves calculation and performance curve based calculation. Also laboratory tests were made with centrifugal and axial fan and also with centrifugal pump. With the results from this thesis the calculation of these programs can be adjusted to be more accurate and also some new features can be added.
Resumo:
Approximately a quarter of electrical power consumption in pulp and paper industry is used in different pumping systems. Therefore, improving pumping system efficiency is a considerable way to reduce energy consumption in different processes. Pumping of wood pulp in different consistencies is common in pulp and paper industry. Earlier, centrifugal pumps were used to pump pulp only at low consistencies, but development of MC technology has made it possible to pump medium consistency pulp. Pulp is a non-Newtonian fluid, which flow characteristics are significantly different than what of water. In this thesis is examined the energy efficiency of pumping medium consistency pulp with centrifugal pump. The factors effecting the pumping of MC pulp are presented and through case study is examined the energy efficiency of pumping in practice. With data obtained from the case study are evaluated the effects of pump rotational speed and pulp consistency on energy efficiency. Additionally, losses caused by control valve and validity of affinity laws in pulp pumping are evaluated. The results of this study can be used for demonstrating the energy consumption of MC pumping processes and finding ways to improve energy efficiency in these processes.