932 resultados para Heat Solar Energy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Micro-generation is the small scale production of heat and/or electricity from a low carbon source and can be a powerful driver for carbon reduction, behavior change, security of supply and economic value. The energy conversion technologies can include photovoltaic panels, micro combined heat and power, micro wind, heat pumps, solar thermal systems, fuel cells and micro hydro schemes. In this paper, a small research of the availability of the conversion apparatus and the prices for the micro wind turbines and photovoltaic systems is made and a comparison between these two technologies is performed in terms of the availability of the resource and costs. An analysis of the new legal framework published in Portugal is done to realize if the incentives to individualspsila investment in sustainable and local energy production is worth for their point of view. An economic evaluation for these alternatives, accounting with the governmentpsilas incentives should lead, in most cases, into attractive return rates for the investment. Apart from the attractiveness of the investment there are though other aspects that should be taken into account and those are the benefits that these choices have to us all. The idea is that micro-generation will not only make a significant direct contribution to carbon reduction targets, it will also trigger a multiplier effect in behavior change by engaging hearts and minds, and providing more efficient use of energy by householders. The diversified profile of power generation by micro-generators, both in terms of location and timing, should reduce the impact of intermittency or plant failures with significant gains for security of supply.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this article is to analyse and evaluate the economical, energetic and environmental impacts of the increasing penetration of renewable energies and electrical vehicles in isolated systems, such as Terceira Island in Azores and Madeira Island. Given the fact that the islands are extremely dependent on the importation of fossil fuels - not only for the production of energy, but also for the transportation’s sector – it’s intended to analyse how it is possible to reduce that dependency and determine the resultant reduction of pollutant gas emissions. Different settings have been analysed - with and without the penetration of EVs. The Terceira Island is an interesting case study, where EVs charging during off-peak hours could allow an increase in geothermal power, limited by the valley of power demand. The percentage of renewable energy in the electric power mix could reach the 74% in 2030 while at the same time, it is possible to reduce the emissions of pollutant gases in 45% and the purchase of fossil fuels in 44%. In Madeira, apart from wind, solar and small hydro power, there are not so many endogenous resources and the Island’s emission factor cannot be so reduced as in Terceira. Although, it is possible to reduce fossil fuels imports and emissions in 1.8% in 2030 when compared with a BAU scenario with a 14% of the LD fleet composed by EVs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this article is to analyse and evaluate the economical, energetic and environmental impacts of the increasing penetration of renewable energies and electrical vehicles in isolated systems, such as Terceira Island in Azores and Madeira Island. Given the fact that the islands are extremely dependent on the importation of fossil fuels - not only for the production of energy, but also for the transportation’s sector – it’s intended to analyse how it is possible to reduce that dependency and determine the resultant reduction of pollutant gas emissions. Different settings have been analysed - with and without the penetration of EVs. The Terceira Island is an interesting case study, where EVs charging during off-peak hours could allow an increase in geothermal power, limited by the valley of power demand. The percentage of renewable energy in the electric power mix could reach the 74% in 2030 while at the same time, it is possible to reduce the emissions of pollutant gases in 45% and the purchase of fossil fuels in 44%. In Madeira, apart from wind, solar and small hydro power, there are not so many endogenous resources and the Island’s emission factor cannot be so reduced as in Terceira. Although, it is possible to reduce fossil fuels imports and emissions in 1.8% in 2030 when compared with a BAU scenario with a 14% of the LD fleet composed by EVs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dye-sensitized solar cell (DSSC) is a promising solution to global energy and environmental problems because of its clean, low-cost, high efficiency, good durability, and easy fabrication. However, enhancing the efficiency of the DSSC still is an important issue. Here we devise a bifacial DSSC based on a transparent polyaniline (PANI) counter electrode (CE). Owing to the sunlight irradiation simultaneously from the front and the rear sides, more dye molecules are excited and more carriers are generated, which results in the enhancement of short-circuit current density and therefore overall conversion efficiency. The photoelectric properties of PANI can be improved by modifying with 4-aminothiophenol (4-ATP). The bifacial DSSC with 4-ATP/PANI CE achieves a light-to-electric energy conversion efficiency of 8.35%, which is increased by ,24.6% compared to the DSSC irradiated from the front only. This new concept along with promising results provides a new approach for enhancing the photovoltaic performances of solar cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is on the self-scheduling for a power producer taking part in day-ahead joint energy and spinning reserve markets and aiming at a short-term coordination of wind power plants with concentrated solar power plants having thermal energy storage. The short-term coordination is formulated as a mixed-integer linear programming problem given as the maximization of profit subjected to technical operation constraints, including the ones related to a transmission line. Probability density functions are used to model the variability of the hourly wind speed and the solar irradiation in regard to a negative correlation. Case studies based on an Iberian Peninsula wind and concentrated solar power plants are presented, providing the optimal energy and spinning reserve for the short-term self-scheduling in order to unveil the coordination benefits and synergies between wind and solar resources. Results and sensitivity analysis are in favour of the coordination, showing an increase on profit, allowing for spinning reserve, reducing the need for curtailment, increasing the transmission line capacity factor. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho realizado sob orientação do Prof. António Brandão Moniz para a disciplina “Sócio-Economia da Inovação” do Mestrado Engenharia Integrado em Engenharia Electrotécnica e Computadores realizado na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa (Portugal)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a case study of heat exchanger network (HEN) retrofit with the objective to reduce the utilities consumption in a biodiesel production process. Pinch analysis studies allow determining the minimum duty utilities as well the maximum of heat recovery. The existence of heat exchangers for heat recovery already running in the process causes a serious restriction for the implementation of grassroot HEN design based on pinch studies. Maintaining the existing HEN, a set of alternatives with additional heat exchangers was created and analysed using some industrial advice and selection criteria. The final proposed solution allows to increase the actual 18 % of recovery heat of the all heating needs of the process to 23 %, with an estimated annual saving in hot utility of 35 k(sic)/y.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Brown adipose tissue (BAT) plays an important role in whole body metabolism and could potentially mediate weight gain and insulin sensitivity. Although some imaging techniques allow BAT detection, there are currently no viable methods for continuous acquisition of BAT energy expenditure. We present a non-invasive technique for long term monitoring of BAT metabolism using microwave radiometry. Methods: A multilayer 3D computational model was created in HFSS™ with 1.5 mm skin, 3-10 mm subcutaneous fat, 200 mm muscle and a BAT region (2-6 cm3) located between fat and muscle. Based on this model, a log-spiral antenna was designed and optimized to maximize reception of thermal emissions from the target (BAT). The power absorption patterns calculated in HFSS™ were combined with simulated thermal distributions computed in COMSOL® to predict radiometric signal measured from an ultra-low-noise microwave radiometer. The power received by the antenna was characterized as a function of different levels of BAT metabolism under cold and noradrenergic stimulation. Results: The optimized frequency band was 1.5-2.2 GHz, with averaged antenna efficiency of 19%. The simulated power received by the radiometric antenna increased 2-9 mdBm (noradrenergic stimulus) and 4-15 mdBm (cold stimulus) corresponding to increased 15-fold BAT metabolism. Conclusions: Results demonstrated the ability to detect thermal radiation from small volumes (2-6 cm3) of BAT located up to 12 mm deep and to monitor small changes (0.5°C) in BAT metabolism. As such, the developed miniature radiometric antenna sensor appears suitable for non-invasive long term monitoring of BAT metabolism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study is based on a previous experimental work in which embedded cylindrical heaters were applied to a pultrusion machine die, and resultant energetic performance compared with that achieved with the former heating system based on planar resistances. The previous work allowed to conclude that the use of embedded resistances enhances significantly the energetic performance of pultrusion process, leading to 57% decrease of energy consumption. However, the aforementioned study was developed with basis on an existing pultrusion die, which only allowed a single relative position for the heaters. In the present work, new relative positions for the heaters were investigated in order to optimise heat distribution process and energy consumption. Finite Elements Analysis was applied as an efficient tool to identify the best relative position of the heaters into the die, taking into account the usual parameters involved in the process and the control system already tested in the previous study. The analysis was firstly developed based on eight cylindrical heaters located in four different location plans. In a second phase, in order to refine the results, a new approach was adopted using sixteen heaters with the same total power. Final results allow to conclude that the correct positioning of the heaters can contribute to about 10% of energy consumption reduction, decreasing the production costs and leading to a better eco-efficiency of pultrusion process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study addresses to the optimization of pultrusion manufacturing process from the energy-consumption point of view. The die heating system of external platen heaters commonly used in the pultrusion machines is one of the components that contribute the most to the high consumption of energy of pultrusion process. Hence, instead of the conventional multi-planar heaters, a new internal die heating system that leads to minor heat losses is proposed. The effect of the number and relative position of the embedded heaters along the die is also analysed towards the setting up of the optimum arrangement that minimizes both the energy rate and consumption. Simulation and optimization processes were greatly supported by Finite Element Analysis (FEA) and calibrated with basis on the temperature profile computed through thermography imaging techniques. The main outputs of this study allow to conclude that the use of embedded cylindrical resistances instead of external planar heaters leads to drastic reductions of both the power consumption and the warm-up periods of the die heating system. For the analysed die tool and process, savings on energy consumption up to 60% and warm-up period stages less than an half hour were attained with the new internal heating system. The improvements achieved allow reducing the power requirements on pultrusion process, and thus minimize industrial costs and contribute to a more sustainable pultrusion manufacturing industry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The global warming due to high CO2 emission in the last years has made energy saving a global problem nowadays. However, manufacturing processes such as pultrusion necessarily needs heat for curing the resin. Then, the only option available is to apply all efforts to make the process even more efficient. Different heating systems have been used on pultrusion, however, the most widely used are the planar resistances. The main objective of this study is to develop another heating system and compares it with the former one. Thermography was used in spite of define the temperature profile along the die. FEA (finite element analysis) allows to understand how many energy is spend with the initial heating system. After this first approach, changes were done on the die in order to test the new heating system and to check possible quality problems on the product. Thus, this work allows to conclude that with the new heating system a significant reduction in the setup time is now possible and an energy reduction of about 57% was achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A eficiência energética e a preocupação com a sustentabilidade têm vindo a ganhar preponderância na sociedade moderna. Este trabalho é uma contribuição para esta tendência onde se pretendeu avaliar e sugerir alterações ao sistema de climatização do edifício Biorama do Parque Biológico de Vila Nova de Gaia (PBG). Procedeu-se em primeiro lugar a uma caracterização física, química e geográfica dos 5 biomas constituintes do Biorama. Para isso, recorreu-se a documentos fornecidos pelo próprio PBG, visitas ao local e registo de medições de alguns parâmetros (temperatura, humidade relativa, qualidade do ar). Posteriormente foi realizado o balanço térmico dos edifícios, de acordo com a legislação em vigor, recorrendo a expressões e conceitos teóricos. Foram determinados valores dos ganhos térmicos de aquecimento de 15811, 10694, 7939, 9233, e 6621 kWh/ano para Floresta tropical, Mesozoico, Dunas, Savana e Deserto, respetivamente. Foram igualmente determinados valores dos ganhos térmicos no verão de 7093, 4798, 3560, 4144 e 2971 kWh na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. As cargas térmicas de aquecimento foram 149, 125, 47, 60 e 51 kW na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. As cargas térmicas de arrefecimento foram iguais a 59, 57, 47, 35 e 36 kW na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. Algumas soluções são avançadas, bem como alternativas comportamentais de modo a corrigir alguns problemas identificados. Uma proposta é a da instalação de painéis solares e acumuladores de calor, com os quais se estima um ganho médio conjunto de 500 W em cada bioma, e representam um investimento de 1050 euros e terão um retorno de 1 ano. Em relação à humidade é sugerido a utilização mais eficaz dos aspersores existentes e a utilização de esponjas, para fazer subir a humidade relativa para valores superiores a 80%. Em sentido inverso, no inverno, propõem-se a utilização de material higroscópico para fazer baixar a humidade relativa em cerca de 5%. Os custos com os suportes e o material higroscópico rondam os 250 €. Por fim, é sugerido a instalação de um aparelho de ar condicionado de 16 000 BTU no corredor de ligação, pois é a única forma de garantir condições de conforto térmico. Esta proposta de arrefecimento com ar condicionado e ainda o recurso a uma cortina de lâminas de plástico, que servem para efetuar uma separação mais eficiente entre ar frio e ar quente, têm um custo aproximado de 350 €. É ainda sugerida a utilização de lonas ou de uma planta trepadeira com um custo por planta de 5€, nas coberturas dos telhados virados a sul, sendo que a zona do corredor deverá ser totalmente coberta, a fim de evitar a exposição solar direta.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Civil

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O presente trabalho pretende mostrar que a aplicação de medidas de conservação de energia (MCE) pode representar uma redução da intensidade de utilização de matérias-primas na construção de um edifício. Mais concretamente, pode representar uma redução da utilização de materiais e equipamentos, e como consequência, uma redução no esforço económico ao primeiro investimento. Podendo posteriormente representar uma redução na utilização de energia durante o período de funcionamento do edifício. A aplicação de MCE no sector da construção tem vindo a ser uma prática corrente nos novos edifícios e edifícios sujeitos a grandes intervenções de reabilitação. Esta prática deve-se à obrigatoriedade de cumprimento de requisitos regulamentares aplicados à otimização do desempenho energético dos edifícios e dos seus sistemas técnicos, nomeadamente, o RCCTE e o RSECE, entretanto revogados pelo REH e pelo RECS, respetivamente. A implementação de MCE apresenta, na maioria dos casos, benefícios económicos para o promotor do edifício, uma vez que se traduz muitas vezes, na otimização do dimensionamento dos sistemas de Aquecimento, Ventilação e Ar Condicionado (AVAC). Esta otimização permite reduzir os custos associados ao primeiro investimento, bem como na utilização de energia por parte do utilizador, logo na redução dos custos de exploração. No entanto, a falta de quantificação dos impactos do dimensionamento dos sistemas AVAC, da redução de utilização de energia e da análise do custo-benefício da sua aplicação pode condicionar o interesse na sua implementação. Neste contexto, surge a presente dissertação, por iniciativa do Instituto Soldadura e Qualidade (ISQ), aplicado a um caso prático de um edifício já construído e propriedade daquela empresa. Com este trabalho pretende-se avaliar o contributo efetivo das MCE implementadas na fase de projeto e na fase de construção, quer na otimização da dimensão de sistemas e equipamentos AVAC, por via da redução das necessidades energéticas, quer na redução de utilização de energia, permitindo, de seguida, uma avaliação custo-benefício.Na base do caso de estudo está o ECOTERMOLAB, o edifício acima referido, adquirido pelo ISQ para instalação de um laboratório de formação, investigação e desenvolvimento na área da energia. Após aquisição pelo ISQ, o edifício sofreu várias alterações/beneficiações, entre as quais a implementação de MCE, tais como, a aplicação de isolamento térmico na envolvente opaca (paredes, pavimentos e coberturas), duplicação dos vãos envidraçados simples, conferindo-lhes melhores caraterísticas térmicas, e pela aplicação de proteções solar. Foram ainda adotadas MCE aos sistemas AVAC, designadamente, pela adoção de recuperadores de calor nas Unidades de Tratamento de Ar Novo (UTAN’s) e de variadores de velocidade nas bombas de circulação de água e nos ventiladores de ar das UTAN’s. Pretendia o ISQ concluir se a aplicação de todas as MCE contribuiu de forma efetiva para o dimensionamento de sistemas e equipamentos AVAC de menor capacidade e, consequentemente, numa redução de utilização de energia. Em sequência, pretendia avaliar a viabilidade económica da aplicação de todas as MCE, estimando o sobrecusto inicial e o tempo necessário para o retorno financeiro daquele investimento. Para alcançar os objetivos propostos, procedeu-se à simulação energética dinâmica do ECOTERMOLAB, utilizando o programa EnergyPlus. Primeiro foi simulada uma situação base do edifício, sem quaisquer MCE. Posteriormente foi caraterizada cada uma das situações de aplicação das MCE, com o objetivo de avaliar o respetivo impacto individual na utilização de energia pelos sistemas AVAC. Por último foram assumidas todas as soluções em conjunto para avaliar o impacto final de todas as MCE na utilização de energia dos sistemas AVAC, bem como no seu dimensionamento. Das simulações dinâmicas foram obtidos os valores das necessidades de aquecimento e arrefecimento, de energia utilizada pelos sistemas AVAC e de caudais de água aquecida e arrefecida circulada. Com estes valores foi feita uma estimativa de dimensionamento dos equipamentos e componentes AVAC para as situações da aplicação de todas as MCE no ECOTERMOLAB e a sua ausência. A partir da diferença dos custos de aquisição dos respetivos equipamentos e dos valores de poupança em energia foi realizado o estudo da viabilidade económica da implementação das MCE neste edifício. Este estudo permitiu concluir que a aplicação das MCE no ECOTERMOLAB levou à redução da dimensão na generalidade dos equipamentos e componentes AVAC. Permitiu, ainda, concluir que houve uma diminuição de utilização de energia por parte destes sistemas e equipamentos para o aquecimento e arrefecimento. Conclui-se ainda que o período de retorno (Payback) do sobrecusto inicial, estimado em 37.822€ é de, aproximadamente, onze anos e meio, para um valor atual líquido (VAL) de 8.061€ e à taxa interna de rentabilidade (TIR) de 7,03%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, perfil Engenharia Sanitária