968 resultados para GPS collar, koala, mate selection, remote acoustic monitor, vocalizations
Resumo:
Jurassic volcanic formations interlayered with (ammonite-bearing) sediments are common in the Caucasus area; this situation is of interest for the numerical calibration of the poorly documented Jurassic portion of the time scale. However, following petrographic study on thin sections no whole-rocks can be considered reliable geochronometers due to subsequent alteration; from about 20 samples, two were selected for plagioclase dating; one (V134) is probably early Kimmeridgian in age; the other (V136) is probably located in the Lower Bathonian stage according to diagnostic ammonites. Cathodoluminescence (CTL) study has shown that sample V136 was similar to usual volcanic feldspars (blue to green colour); however, the lack of CTL of the V134 plagioclase is a character common to diagenetic feldspars; consequently, in spite of a good optical preservation, this geo-chronometer cannot give an age representative of the time of emplacement of the lava flow. We have combined CTL observation with microprobe analysis in order to document the poorly known CTL behaviour of volcanic feldspars; cations Ti4+ and Fe2+ play a major role in the CTL colour of plagioclases and are able to document the growing history of these feldspars ; phenocrysts are initially rich in Fe2+ (core of the crystals, green in colour), then richer in Ti toward the exterior; microcrysts are even richer in Ti (blue to bright blue). We have also observed that natural CTL colour was modified resulting from acid ``cleaning'' of the separated feldspars : the initial blue or green colour tends to change to yellow or violet, respectively, after acid treatment probably due to oxydation of Fe2+ toward Fe3+. X-ray and microprobe analyses both indicated that plagioclases from sample V134 was near the sodic end member (albite) suggesting a diagenetic origin in this andesitic basalt; In contrast, sample V136 contains a calcic plagioclase of common composition for a doleritic basalt. The K-Ar conventional technique was applied as a preliminary tool for radiometric analysis. The Kimmeridgian Na-plagioclase sample gave a ``rejuvenated'' (85 Ma) apparent age which confirms a late genesis for the separated plagioclase phase; this interpretation is based on CTL observation, X-ray analysis, and microprobe analysis ; these techniques are able to distinguish samples which have been submitted to diagenetic alteration from those which have not. An age consistent with the stratigraphic location has been obtained from sample V136. This age of 161 +/- 3 (2-sigma) Ma, is the first one available from a sample palaeontologically located with reasonable precision within the mid Jurassic time.
Resumo:
OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.
Resumo:
We evaluated a new combined sensor for monitoring transcutaneous carbon dioxide tension (PtcCO2) and oxygen tension (PtcO2) in 20 critically ill newborn infants. Arterial oxygen tension (PaO2) ranged from 16 to 126 torr and arterial carbon dioxide tension (PaCO2) from 14 to 72 torr. Linear correlation analysis (100 paired values) of PtcO2 versus PaO2 showed an r value of 0.75 with a regression equation of PtcO2 = 8.59 + 0.905 (PaO2), while PtcCO2 versus PaCO2 revealed a correlation coefficient of r = 0.89 with an equation of PtcCO2 = 2.53 + 1.06 (PaCO2). The bias between PaO2 and PtcO2 was -2.8 with a precision of +/- 16.0 torr (range, -87 to +48 torr). The bias between PaCO2 and PtcCO2 was -5.1 with a precision of +/- 7.3 torr (range, -34 to +8 torr). The transcutaneous sensor detected 83% of hypoxia (PaO2 less than 45 torr), 75% of hyperoxia (PaO2 greater than 90 torr), 45% of hypocapnia (PaCO2 less than 35 torr), and 96% of hypercapnia (PaCO2 greater than 45 torr). We conclude that the reliability of the combined transcutaneous PO2 and PCO2 monitor in sick neonates is good for detecting hypercapnia, fair for hypoxia and hyperoxia, but poor for hypocapnia. It is an improvement in that it spares available skin surface and requires less handling, but it appears to be slightly less accurate than the single electrodes.
Resumo:
We present an approach for creating image mosaics using navigation data consisting on 3D position estimates provided by sensors such as LBL available in deep water surveys. A central issue with acoustic 3D positioning is that the accuracy is far too low compositing the images within reasonable accuracy
Resumo:
A team representing Iowa Workforce Development, the Office of Energy Independence, the Department of Natural Resources, the Department of Public Safety, the Iowa Utilities Board, the Department of Economic Development and Iowa Community Colleges reviewed many reports on green jobs published by states, associations and private research companies with the purpose of determining whether the number of “green collar” jobs in Iowa’s economy can be quantified. The team found that there was no standard on definition, identifying jobs or occupations, or level of inclusion for counting green collar jobs. All reports were tailored to their own audiences, without regard to the ability to measure their results against findings made by other states or organizations. Green collar jobs can be found in construction, manufacturing, installation, maintenance, agriculture and many other sectors of the economy. While some of the green collar jobs are in new occupations and industries, most are existing jobs that demand new green collar skills.
Resumo:
How positive selection molds the T cell repertoire has been difficult to examine. In this study, we use TCR-beta-transgenic mice in which MHC shapes TCR-alpha use. Differential AV segment use is directly related to the constraints placed on the composition of the CDR3 loops. Where these constraints are low, efficient selection of alphabeta pairs follows. This mode of selection preferentially uses favored AV-AJ rearrangements and promotes diversity. Increased constraint on the alpha CDR3 loops leads to inefficient selection associated with uncommon recombination events and limited diversity. Further, the two modes of selection favor alternate sets of AJ segments. We discuss the relevance of these findings to the imprint of self-MHC restriction and peripheral T cell activation.
Resumo:
Alpha-band activity (8-13 Hz) is not only suppressed by sensory stimulation and movements, but also modulated by attention, working memory and mental tasks, and could be sensitive to higher motor control functions. The aim of the present study was to examine alpha oscillatory activity during the preparation of simple left or right finger movements, contrasting the external and internal mode of action selection. Three preparation conditions were examined using a precueing paradigm with S1 as the preparatory and S2 as the imperative cue: Full, laterality instructed by S1; Free, laterality freely selected and None, laterality instructed by S2. Time-frequency (TF) analysis was performed in the alpha frequency range during the S1-S2 interval, and alpha motor-related amplitude asymmetries (MRAA) were also calculated. The significant MRAA during the Full and Free conditions indicated effective external and internal motor response preparation. In the absence of specific motor preparation (None), a posterior alpha event-related desynchronization (ERD) dominated, reflecting the main engagement of attentional resources. In Full and Free motor preparation, posterior alpha ERD was accompanied by a midparietal alpha event-related synchronization (ERS), suggesting a concomitant inhibition of task-irrelevant visual activity. In both Full and Free motor preparation, analysis of alpha power according to MRAA amplitude revealed two types of functional activation patterns: (1) a motor alpha pattern, with predominantly midparietal alpha ERS and large MRAA corresponding to lateralized motor activation/visual inhibition and (2) an attentional alpha pattern, with dominating right posterior alpha ERD and small MRAA reflecting visuospatial attention. The present results suggest that alpha oscillatory patterns do not resolve the selection mode of action, but rather distinguish separate functional strategies of motor preparation.
Resumo:
Many traits and/or strategies expressed by organisms are quantitative phenotypes. Because populations are of finite size and genomes are subject to mutations, these continuously varying phenotypes are under the joint pressure of mutation, natural selection and random genetic drift. This article derives the stationary distribution for such a phenotype under a mutation-selection-drift balance in a class-structured population allowing for demographically varying class sizes and/or changing environmental conditions. The salient feature of the stationary distribution is that it can be entirely characterized in terms of the average size of the gene pool and Hamilton's inclusive fitness effect. The exploration of the phenotypic space varies exponentially with the cumulative inclusive fitness effect over state space, which determines an adaptive landscape. The peaks of the landscapes are those phenotypes that are candidate evolutionary stable strategies and can be determined by standard phenotypic selection gradient methods (e.g. evolutionary game theory, kin selection theory, adaptive dynamics). The curvature of the stationary distribution provides a measure of the stability by convergence of candidate evolutionary stable strategies, and it is evaluated explicitly for two biological scenarios: first, a coordination game, which illustrates that, for a multipeaked adaptive landscape, stochastically stable strategies can be singled out by letting the size of the gene pool grow large; second, a sex-allocation game for diploids and haplo-diploids, which suggests that the equilibrium sex ratio follows a Beta distribution with parameters depending on the features of the genetic system.
Resumo:
O conhecimento da variabilidade da fertilidade do solo em áreas cultivadas pode trazer importantes subsídios para a racionalização de uso dos corretivos e fertilizantes do solo. O objetivo deste estudo foi determinar a variabilidade da fertilidade do solo por meio do fracionamento de um talhão comercial em pequenas células de manejo. O experimento foi realizado na Fazenda Alto Alegre em Planaltina - GO, numa área de 373 ha de um Latossolo cultivada com milho na safra 2003/04. Traçado um polígono da área, procedeu-se à divisão em 80 células de manejo de quatro hectares cada. A amostragem do solo seguiu uma diagonal com doze pontos para formar a amostra composta representativa dentro de cada célula. As coordenadas desses pontos foram obtidas e arquivadas. Realizou-se a análise da textura do solo e da fertilidade do solo. A produtividade de cada célula foi obtida por meio da colhedora equipada com Sistema de Posicionamento Geográfico (GPS) e monitor de rendimento de grãos. Na análise da variabilidade espacial dos dados, foram considerados parâmetros estatísticos descritivos. A medida de correlação linear de Pearson a 5 e 1 % dos atributos de fertilidade com a produtividade do milho e altitude foi realizada. A variabilidade foi considerada alta para o P disponível, Cu e Zn; média, para matéria orgânica, S, Ca, Mg, acidez potencial, soma de bases, capacidade de troca de cátions a pH 7,0, saturação por bases, B, Fe e Mn, e baixa, para pH e K. Os coeficientes de correlação linear foram significativos e positivos para a matéria orgânica e boro versus produtividade do milho. Contudo, para Cu, manganês e Zn foram significativos e negativos. Em estudos de escala de campo, normalmente não é possível isolar ou medir todos os fatores bióticos e abióticos que influenciam a produção da cultura. Entretanto, verificou-se que o conhecimento da variabilidade da fertilidade e produtividade pode fornecer importantes subsídios para a racionalização do uso de insumos.
Resumo:
BACKGROUND: The criteria for choosing relevant cell lines among a vast panel of available intestinal-derived lines exhibiting a wide range of functional properties are still ill-defined. The objective of this study was, therefore, to establish objective criteria for choosing relevant cell lines to assess their appropriateness as tumor models as well as for drug absorption studies. RESULTS: We made use of publicly available expression signatures and cell based functional assays to delineate differences between various intestinal colon carcinoma cell lines and normal intestinal epithelium. We have compared a panel of intestinal cell lines with patient-derived normal and tumor epithelium and classified them according to traits relating to oncogenic pathway activity, epithelial-mesenchymal transition (EMT) and stemness, migratory properties, proliferative activity, transporter expression profiles and chemosensitivity. For example, SW480 represent an EMT-high, migratory phenotype and scored highest in terms of signatures associated to worse overall survival and higher risk of recurrence based on patient derived databases. On the other hand, differentiated HT29 and T84 cells showed gene expression patterns closest to tumor bulk derived cells. Regarding drug absorption, we confirmed that differentiated Caco-2 cells are the model of choice for active uptake studies in the small intestine. Regarding chemosensitivity we were unable to confirm a recently proposed association of chemo-resistance with EMT traits. However, a novel signature was identified through mining of NCI60 GI50 values that allowed to rank the panel of intestinal cell lines according to their drug responsiveness to commonly used chemotherapeutics. CONCLUSIONS: This study presents a straightforward strategy to exploit publicly available gene expression data to guide the choice of cell-based models. While this approach does not overcome the major limitations of such models, introducing a rank order of selected features may allow selecting model cell lines that are more adapted and pertinent to the addressed biological question.