919 resultados para Fluorescence resonance energy transfer, FRET stoichiometry, Green Fluorescent Protein, Fluorescence spectroscopy, Signal Transduction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Na+ near membranes controls our nerve signals, besides several other crucial bioprocesses. We demonstrate that fluorescent PET (photoinduced electron transfer) sensor molecules target Na+ in nanospaces near micellar membranes with excellent discrimination against H+. They find that Na+ near anionic micelles is concentrated by factors of upto 160. Sensor molecules which are not held tight to the micelle surface find a Na+ amplification factor of 8 only. These findings are strengthened by the employment of control compounds whose PET processes are permanently ‘on’ or permanently ‘off’.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La fonction des canaux ioniques est finement régulée par des changements structuraux de sites clés contrôlant l’ouverture du pore. Ces modulations structurales découlent de l’interaction du canal avec l’environnement local, puisque certains domaines peuvent être suffisamment sensibles à des propriétés physico-chimiques spécifiques. Les mouvements engendrés dans la structure sont notamment perceptibles fonctionnellement lorsque le canal ouvre un passage à certains ions, générant ainsi un courant ionique mesurable selon le potentiel électrochimique. Une description détaillée de ces relations structure-fonction est cependant difficile à obtenir à partir de mesures sur des ensembles de canaux identiques, puisque les fluctuations et les distributions de différentes propriétés individuelles demeurent cachées dans une moyenne. Pour distinguer ces propriétés, des mesures à l’échelle de la molécule unique sont nécessaires. Le but principal de la présente thèse est d’étudier la structure et les mécanismes moléculaires de canaux ioniques par mesures de spectroscopie de fluorescence à l’échelle de la molécule unique. Les études sont particulièrement dirigées vers le développement de nouvelles méthodes ou leur amélioration. Une classe de toxine formeuse de pores a servi de premier modèle d’étude. La fluorescence à l’échelle de la molécule unique a aussi été utilisée pour l’étude d’un récepteur glutamate, d’un récepteur à la glycine et d’un canal potassique procaryote. Le premier volet porte sur l’étude de la stœchiométrie par mesures de photoblanchiment en temps résolu. Cette méthode permet de déterminer directement le nombre de monomères fluorescents dans un complexe isolé par le décompte des sauts discrets de fluorescence suivant les événements de photoblanchiment. Nous présentons ici la première description, à notre connaissance, de l’assemblage dynamique d’une protéine membranaire dans un environnement lipidique. La toxine monomérique purifiée Cry1Aa s’assemble à d’autres monomères selon la concentration et sature en conformation tétramérique. Un programme automatique est ensuite développé pour déterminer la stœchiométrie de protéines membranaires fusionnées à GFP et exprimées à la surface de cellules mammifères. Bien que ce système d’expression soit approprié pour l’étude de protéines d’origine mammifère, le bruit de fluorescence y est particulièrement important et augmente significativement le risque d’erreur dans le décompte manuel des monomères fluorescents. La méthode présentée permet une analyse rapide et automatique basée sur des critères fixes. L’algorithme chargé d’effectuer le décompte des monomères fluorescents a été optimisé à partir de simulations et ajuste ses paramètres de détection automatiquement selon la trace de fluorescence. La composition de deux canaux ioniques a été vérifiée avec succès par ce programme. Finalement, la fluorescence à l’échelle de la molécule unique est mesurée conjointement au courant ionique de canaux potassiques KcsA avec un système de fluorométrie en voltage imposé. Ces enregistrements combinés permettent de décrire la fonction de canaux ioniques simultanément à leur position et densité alors qu’ils diffusent dans une membrane lipidique dont la composition est choisie. Nous avons observé le regroupement de canaux KcsA pour différentes compositions lipidiques. Ce regroupement ne paraît pas être causé par des interactions protéine-protéine, mais plutôt par des microdomaines induits par la forme des canaux reconstitués dans la membrane. Il semble que des canaux regroupés puissent ensuite devenir couplés, se traduisant en ouvertures et fermetures simultanées où les niveaux de conductance sont un multiple de la conductance « normale » d’un canal isolé. De plus, contrairement à ce qui est actuellement suggéré, KcsA ne requiert pas de phospholipide chargé négativement pour sa fonction. Plusieurs mesures indiquent plutôt que des lipides de forme conique dans la phase cristalline liquide sont suffisants pour permettre l’ouverture de canaux KcsA isolés. Des canaux regroupés peuvent quant à eux surmonter la barrière d’énergie pour s’ouvrir de manière coopérative dans des lipides non chargés de forme cylindrique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemical sensors have growing interest in the determination of food additives, which are creating toxicity and may cause serious health concern, drugs and metal ions. A chemical sensor can be defined as a device that transforms chemical information, ranging from the concentration of a specific sample component to total composition analysis, into an analytically useful signal. The chemical information may be generated from a chemical reaction of the analyte or from a physical property of the system investigated. Two main steps involved in the functioning of a chemical sensor are recognition and transduction. Chemical sensors employ specific transduction techniques to yield analyte information. The most widely used techniques employed in chemical sensors are optical absorption, luminescence, redox potential etc. According to the operating principle of the transducer, chemical sensors may be classified as electrochemical sensors, optical sensors, mass sensitive sensors, heat sensitive sensors etc. Electrochemical sensors are devices that transform the effect of the electrochemical interaction between analyte and electrode into a useful signal. They are very widespread as they use simple instrumentation, very good sensitivity with wide linear concentration ranges, rapid analysis time and simultaneous determination of several analytes. These include voltammetric, potentiometric and amperometric sensors. Fluorescence sensing of chemical and biochemical analytes is an active area of research. Any phenomenon that results in a change of fluorescence intensity, anisotropy or lifetime can be used for sensing. The fluorophores are mixed with the analyte solution and excited at its corresponding wavelength. The change in fluorescence intensity (enhancement or quenching) is directly related to the concentration of the analyte. Fluorescence quenching refers to any process that decreases the fluorescence intensity of a sample. A variety of molecular rearrangements, energy transfer, ground-state complex formation and collisional quenching. Generally, fluorescence quenching can occur by two different mechanisms, dynamic quenching and static quenching. The thesis presents the development of voltammetric and fluorescent sensors for the analysis of pharmaceuticals, food additives metal ions. The developed sensors were successfully applied for the determination of analytes in real samples. Chemical sensors have multidisciplinary applications. The development and application of voltammetric and optical sensors continue to be an exciting and expanding area of research in analytical chemistry. The synthesis of biocompatible fluorophores and their use in clinical analysis, and the development of disposable sensors for clinical analysis is still a challenging task. The ability to make sensitive and selective measurements and the requirement of less expensive equipment make electrochemical and fluorescence based sensors attractive.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three promising variants of autofluorescent proteins have been analyzed photophysically for their proposed use in single-molecule microscopy studies in living cells to compare their superiority to other fluorescent proteins previously reported regarding the number of photons emitted. The first variant under investigation the F46L mutant of eYFP has a 10% greater photon emission rate and > 50% slower photobleaching rate on average than the standard eYFP fluorophore. The monomeric red fluorescent protein (mRFP) has a fivefold lower photon emission rate, likely due to the monomeric content, and also a tenfold faster photobleaching rate than the DsRed fluorescent protein. In contrast, the previously reported eqfp611 has a 50% lower emission rate yet photobleaches more than a factor 2 slowly. We conclude that the F46L YFP and the eqfp611 are superior new options for single molecule imaging and tracking studies in living cells. Studies were also performed on the effects of forced quenching of multiple fluorescent proteins in sub-micrometer regions that would show the effects of dimerization at low concentration levels of fluorescent proteins and also indicate corrections to stoichiometry patterns with fluorescent proteins previously in print. We also introduce properties at the single molecule level of new FRET pairs with combinations of fluorescent proteins and artificial fluorophores.