989 resultados para Fast Five
Resumo:
Birds have remained the dominant model for studying the mechanisms of animal navigation for decades, with much of what has been discovered coming from laboratory studies or model systems. The miniaturisation of tracking technology in recent years now promises opportunities for studying navigation during migration itself (migratory navigation) on an unprecedented scale. Even if migration tracking studies are principally being designed for other purposes, we argue that attention to salient environmental variables during the design or analysis of a study may enable a host of navigational questions to be addressed, greatly enriching the field. We explore candidate variables in the form of a series of contrasts (e. g. land vs ocean or night vs day migration), which may vary naturally between migratory species, populations or even within the life span of a migrating individual. We discuss how these contrasts might help address questions of sensory mechanisms, spatiotemporal representational strategies and adaptive variation in navigational ability. We suggest that this comparative approach may help enrich our knowledge about the natural history of migratory navigation in birds.
Resumo:
Coccidiostats are the only veterinary drugs still permitted to be used as feed additives to treat poultry for coccidiosis. To protect consumers, maximum levels for their presence in food and feed have been set by the European Union (EU). To monitor these coccidiostats, a rapid and inexpensive screening method would be a useful tool. The development of such a screening method, using a flow cytometry-based immunoassay, is described. The assay uses five sets of colour-coded paramagnetic microspheres for the detection of six selected priority coccidiostats. Different coccidiostats, with and without carrier proteins, were covalently coupled onto different bead sets and tested in combination with polyclonal antisera and with a fluorescent-labelled secondary antibody. The five optimal combinations were selected for this multiplex and a simple-to-use sample extraction method was applied for screening blank and spiked eggs and feed samples. A very good correlation (r ranging from 0.995 to 0.999) was obtained with the responses obtained in two different flow cytometers (Luminex 100 and FLEXMAP 3D). The sensitivities obtained were in accordance with the levels set by the EU as the measured limits of detection for narasin/salinomycin, lasalocid, diclazuril, nicarbazin (4,4'-dinitrocarbanilide) and monensin in eggs were 0.01, 0.1, 0.5, 53 and 0.1 µg/kg and in feed 0.1, 0.2, 0.3, 9 and 1.5 µg/kg, respectively.
Resumo:
In this letter we present data comparing the yield of Cu K-alpha radiation for foils of differing thickness irradiated with a Ti:Sapphire laser generating 40 fs pulses at 800 nm and incident at 45 degrees. At tight focus, the yields for all thicknesses are similar, whilst away from best focus there are clear differences. We discuss the origin of these similarities and differences in terms of the penetration of fast electrons into the foil and the possible importance of refluxing of fast electrons as they reach the non-irradiated side of the foil.
Resumo:
OBJECTIVE: Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states?
DESIGN: Animal study.
SETTING: University research laboratory.
SUBJECTS: Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg.
INTERVENTIONS: Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone).
MEASUREMENTS AND MAIN RESULTS: The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set).
CONCLUSIONS: As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.
Resumo:
In April 1998, a holding lagoon containing pyrite ore processing waste, failed and released 5-6 million m3 of highly polluting sludge and acidic water. Over 2650 ha of the internationally important Doñana Natural Park became contaminated, along with <100 ha of the more pristine Doñana National Park. In order to assess the affect of the spill on waterfowl from Doñana, bone and liver samples from 124 individuals have been analysed for As, Pb, Cu, Zn and Se. Five species have been studied, from the Rallidae (rails), Anatini (dabbling ducks) and Aythyini (pochards) families. Geometric mean bone concentrations 2-3 months after the spill were in the order of Zn > Cu > Pb > Se > As, while liver concentrations were in the order of Zn > Cu > Se > Pb > As. Dry weight bone concentrations ranged from n.d-1.76 mg kg(-1) As, 109.4-247.6 mg kg(-1) Zn, 0.06-1.27 mg kg(-1) Se, n.d-134.11 mg kg(-1) Pb, and 2.18-8.92 mg kg(-1) Cu. Wet weight liver concentrations ranged from n.d-0.34 mg kg(-1) As, 29.8-220.1 mg kg(-1) Zn, 0.15-0.85 mg kg(-1) Se, n.d-3.80 mg kg(-1) Pb, and 7.30-742.96 mg kg(-1) Cu. The most important factor related to the accumulation of these metals was commonly species; however, location and sex also had important effects on liver As levels, location and age affected Cu levels, while Zn and Pb were affected by age, sex and location. Birds from Natural Park areas were found to have significantly higher levels of bone Zn, Pb and Cu, and liver As and Cu than birds from National Park areas. Female birds had higher liver As, Zn and Pb than males; whilst adults appeared to have lower bone As and Zn but higher liver Pb than chicks/juveniles. Although metal concentrations were elevated in certain individuals, in the majority of birds studied, they did not reach levels widely considered to be toxic. However, it would appear that As and Cu liver levels (which may be indicative of short-medium term pollutant exposure) were elevated in waterbirds which died in the spill contaminated Natural Park, 2-3 months after the disaster.
Resumo:
Real time digital signal processing demands high performance implementations of division and square root. This can only be achieved by the design of fast and efficient arithmetic algorithms which address practical VLSI architectural design issues. In this paper, new algorithms for division and square root are described. The new schemes are based on pre-scaling the operands and modifying the classical SRT method such that the result digits and the remainders are computed concurrently and the computations in adjacent rows are overlapped. Consequently, their performance exceeds that of the SRT methods. The hardware cost for higher radices is considerably more than that of the SRT methods but for many applications, this is not prohibitive. A system of equations is presented which enables both an analysis of the method for any radix and the parameters of implementations to be easily determined. This is illustrated for the case of radix 2 and radix 4. In addition, a highly regular array architecture combining the division and square root method is described. © 1994 Kluwer Academic Publishers.
Resumo:
Research on fusion fast ignition (FI) initiated by laser-driven ion beams has made substantial progress in the last years. Compared with electrons, FI based on a beam of quasi-monoenergetic ions has the advantage of a more localized energy deposition, and stiffer particle transport, bringing the required total beam energy close to the theoretical minimum. Due to short pulse laser drive, the ion beam can easily deliver the 200 TW power required to ignite the compressed D-T fuel. In integrated calculations we recently simulated ion-based FI targets with high fusion gain targets and a proof of principle experiment [1]. These simulations identify three key requirements for the success of ion-driven fast ignition (IFI): (1) the generation of a sufficiently high-energetic ion beam (approximate to 400-500 MeV for C), with (2) less than 20% energy spread at (3) more than 10% conversion efficiency of laser to beam energy. Here we present for the first time new experimental results, demonstrating all three parameters in separate experiments. Using diamond nanotargets and ultrahigh contrast laser pulses we were able to demonstrate >500 MeV carbon ions, as well as carbon pulses with Delta E/E
Resumo:
PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 ± 0.28 minutes, 2.31 ± 0.28 minutes, and 4.14 ± 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF. © 2002 by Elsevier Science Inc. All rights reserved.