982 resultados para Equipamento tomográfico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ceramic pigments are colored inorganic substances that during the process of dispersion in the ceramic glazes and subsequent calcination, are stable against physical and chemical attack. Therefore, they are crystalline compounds applied in the ceramic industry for coloring vitreous base. In this study, the Pechini method was used for obtaining the pigment CuCr2O4 with heat treatment at the temperatures of 800, 900 and 1000 ° C. The powder pigments were characterized on their structural, morphological and colorimetric aspects. The thermal analysis conducted on an amorphous precursor in a TG / DTA indicates the weight loss in the entire temperature range investigated, with characteristic exothermic peak of the elimination of the organic composition of the precursor around 300°C. The development of the crystalline phases were investigated by XRD, using a diffractometer with Cu Ka radiation and graphite monochromator, where it was observed the presence of crystalline phases corresponding to Cr2O3 and CuCr2O4.The measurements of the specific surface area of the powders pigments were carried out in an equipment Micromeritcs, model ASAP 2000, using N2 as gas of adsorption/desorption. The colorimetric measurements of the pigments were made in a colorimeter Gretac Macbeth Color-eye spectrophotometer 2180 / 2180UV in CIELAB standards. Based on the obtained results, it can be verified the thermal stability of the powder pigments of green coloration, which enables it as an alternative to the materials currently used in the manufacture of ceramic tiles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aims to study the possible causes of cracks founded and recovered in translation cars of ore Forklift / ore Reclaimer. To identify the possible causes of cracks observed on the equipment it was used a static approach analysis, using a finite element method as an analysis tool, using a specific structural analysis program. After making the model, a strain gage measurement was necessary because there may be significant amounts of masses of non-structural components that were not modeled and were not available in the drawings, as well as fouling ore. With the calibrated model it was processed analyses with the load cases of dead load, product, wind and excavation. After the processing, it was observed that none of these load cases resulted in values that caused the crack, so another three hypotheses were tested: depression and misalignment, jacking and translation of only three cars. Of these three hypotheses it was observed that the jacking coud be the cause of the cracks, because the distribution of stress. Due to the miss of parameters, like the height utilized in this process, it was not possible to affirm the real stress level

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The finite element method is of great importance for the development and analysis of a new product being designed or already on the market, and that requires some specific request or special application. The tower crane, being an essential equipment for modern construction to increase productivity and safety on construction sites, is required for many types of special applications day after day, in many kinds of work. Paying attention to this growing need for handling special projects for the tower crane, faced with the importance and necessity of development and improvement of knowledge in more accurate and practical calculation methods such as the finite element method , for greater agility and precision in the response to a new project. The tower crane is defined by the maximum load moment that it can act with a certain amount of load. The tower crane which will be analyzed in this work , for example, is a tower crane with a resulting capacity of 85 Metric Tons which are considered basic dimensions data of a fisical tower crane of a crane company Liebherr in Guaratinguetá . Thus, the project analysis will begin with the threedimensional representation of the crane lines with AutoCAD software , conversion of this model to the format accepted ANSYS Workbench and completion of 3D modeling of structural components in Design module ANSYS software. After structural modeling is completed, the simulation is performed in static simulation of ANSYS Workbench software mode. The standards will be adopted to DIN (Deutsches Institut für Normung) and EN 14439 (Europäische Normung 14439) and some NR 's related to specific security class of tower cranes, which will be referred throughout the work

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dentre as várias espécies de café, Coffea arabica L. destaca-se pela sua ampla importância comercial relacionada ao consumo da bebida e à produção de óleo. O grão de café possui grande quantidade de compostos fenólicos bioativos - destacando-se os com atividade antioxidante e fotoprotetora - e após a extração do óleo há sobra de grande quantidade de subprodutos, denominado torta. O objetivo desse trabalho é produzir um extrato a partir da torta de café selecionando o melhor solvente extrator, avaliando o teor de compostos fenólicos e o potencial antioxidante, para o emprego como ativo cosmético em formulações desenvolvidas, com análise in vitro para quantificação do Fator de Proteção Solar (FPS) dessas. Os extratos foram previamente produzidos por sonicação utilizando solventes de diferentes polaridades, e o extrato escolhido foi produzido em maior escala por maceração e realizado também extração exaustiva com o solvente escolhido (extrato etanólico 70%, v/v). Na determinação do teor de fenólicos totais foi utilizado o método com o reagente Folin-Ciocalteu. Foi avaliado também o rendimento (m/m) dos extratos e atividade antioxidante pelo método do radical DPPH. O extrato apresentou boa atividade antioxidante e alto teor de compostos fenólicos em comparação com outras plantas consideradas referências nessas propriedades. Para o preparo das formulações foram utilizados matérias primas aprovadas pela ANVISA, e as quantidades dos filtros solares químicos empregados para obtenção de Fator de Proteção Solar (FPS) teórico próximo de 30, utilizou-se como ferramenta o BASF - Sunscreen Simulator. As formulas desenvolvidas e preparadas foram analisadas com o equipamento Optometrics SPF 290S, capaz de fazer a determinação do FPS por análise in vitro. A preparação selecionada foi a que apresentou FPS adequado pela análise in vitro e sensorial mais leve, visto ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study describes the preliminary design of a static skip compactor and its hydraulic system. The objective of this study is to develop and to improve the design of a made project. The methodology used in this study was to analyze the faults of the already done projects and to suggest possible improvements. The result is a preliminary design of a skip with the main necessary dimensions and specifications to build that equipment. The conclusion of this study is a preliminary project of simple equipment that makes in very efficient way its work

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to present the design and development of a speed reducer worm gear that will be implemented on an inclined treadmill that aims to raise the load below the top floor. The project start was made with research on issues related to mechanisms and machine elements, and these theories of fundamental importance in the development of device components, along with the help of SolidWorks software that was used to model the main parts of the project and Microsoft Office Excel 2007 was used to alight formulas to perform calculations of the project. All data for calculations were taken from the conditions of the problem to be solved in the best possible way the proposed problem (lifting load from the belt). Following the entire sequence of design gearbox assembly, beginning in pre-sizing and endless selection of electric motor, which consists of an iterative project, then scaling the worm gear and crown, shafts, splines, calculation and bearing selection

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho foi realizado nas dependências da FURP (Fundação para o Remédio Popular) de Américo Brasiliense - SP, com o objetivo de validar o método de determinação para residual de detergente alcalino nos equipamentos de revestimento de comprimidos. O trabalho foi desenvolvido no laboratório do Controle de Qualidade da FURP. A validação de limpeza é um tema pouco visto durante o curso de graduação em Farmácia - Bioquímica, porém bastante importante dentro da Indústria Farmacêutica. O processo de limpeza dos equipamentos utilizados na indústria farmacêutica deve ser validado para garantir a qualidade dos produtos. Determinar o residual de um produto de limpeza em um equipamento assegura que o agente de limpeza usado no processo, no caso o detergente alcalino, esteja em uma quantidade dentro do limite aceitável após a limpeza do equipamento. Primeiramente, validou-se o método analítico utilizado para determinar a quantidade de resíduo através da condutividade. Foram analisados os parâmetros linearidade, precisão e especificidade, que se encontraram dentro do limite permitido. Também foi realizado o estudo de recuperação (recovery) do resíduo de detergente do equipamento para confirmar a eficácia da técnica de amostragem juntamente com o método analítico quantitativo escolhido. Após a validação da metodologia analítica quantitativa e o estudo de recuperação foi possível definir um procedimento adequado para a análise do residual de detergente alcalino nos equipamentos submetidos ao processo de limpeza. Juntamente com o setor de Garantia da Qualidade, também foi realizado o estudo de validação da limpeza dos equipamentos da linha de sólidos da FURP (unidade Américo Brasiliense), neste estudo foi avaliado se o procedimento de limpeza estava sendo eficiente e também foi possível fazer a determinação de residual de detergente alcalino presente no equipamento após amostragem com swab, ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the remodeling of autologous and homologous bone grafts in humans, using tomographic images. For this, CT images from 10 patients (5 treated with autologous bone grafts and 5 treated with homologous bone grafts), made previously to the grafting procedures, and 14 and 180 days post operatory were evaluated regarding to bone height, width, and density, in a total of 19 bone blocks, 10 homologous and 9 autologous. Results showed similarities between the two tested materials regarding bone width and density. It can be concluded that the homologous bone presented, in a tomographic approach, after 180 days of follow-up, characteristics which can corroborate its use as a bone graft material, providing and sustaining a good bone volume for oral rehabilitation with dental implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of specimen size, in comparison with the ISO Standard, on the three point flexural strength of resin composite restorative materials Filtek Supreme and Filtek Z-250. Forty specimens were fabricated for each material with the following length, width and thickness measurements (n = 10): 1) 20 × 2 × 2 mm (ISO 4049); 2) 10 × 2 × 1 mm; 3) 10 × 1 × 1 mm; 4) 8 × 0.8 × 0.8 mm. The composites were inserted in a single increment into two-piece metal device and light-polymerized. The specimens were dry stored at 37 ± 1 °C and protected from light for 7 days. After this period, flexural strength was measured by three-point flexure test using MTS 810 equipment, with a load cell of 10 kN at a speed of 0.5 mm/min. For the evaluated sizes, the results showed significant variability (p = 0.00) with values when compared with the ISO Standard (116.700 MPa), being statistically higher for the test specimens measuring 10 × 1 × 1 mm (142.530 MPa), similar for those of 10  ×  2  ×  1  mm (115.815 MPa) and lower for those of 8 × 0.8 × 0.8 mm (86.650 MPa). There was statistical equality (p = 0.08) for the studied composites (Filtek Supreme, 125.270 MPa; Filtek Z-250, 108.130 MPa). Specimens measuring 10 × 2 × 1 mm provided flexural strength values equivalent to those obtained in the sizes recommended by the ISO 4049 standard, with lower consumption of material, energy and time.