986 resultados para EXTRACTION CHROMATOGRAPHY
Resumo:
The adsorption and desorption coefficients of atrazine, methiocarb and simazine on a sandy loam soil were measured in this study with soil column liquid chromatographic (SCLC) technique. The adsorption and desorption data of all the three pesticides followed Freundlich isotherms revealing the existence of hysteresis. In comparing with other methods, SCLC method showed some characteristics such as rapidity, online and accuracy.
Resumo:
A resurgence of interest in the human plasma proteome has occurred in recent years because it holds great promise of revolution in disease diagnosis and therapeutic monitoring. As one of the most powerful separation techniques, multidimensional liquid chromatography has attracted extensive attention, but most published works have focused on the fractionation of tryptic peptides. In this study, proteins from human plasma were prefractionated by online sequential strong cation exchange chromatography and reversed-phase chromatography. The resulting 30 samples were individually digested by trypsin, and analyzed by capillary reversed-phase liquid chromatography coupled with linear ion trap mass spectrometry. After meeting stringent criteria, a total of 1292 distinct proteins were successfully identified in our work, among which, some proteins known to be present in serum in < 10 ng/mL were detected. Compared with other works in published literatures, this analysis offered a more full-scale list of the plasma proteome. Considering our strategy allows high throughput of protein identification in serum, the prefractionation of proteins before MS analysis is a simple and effective method to facilitate human plasma proteome research.
Resumo:
An iminodiacetic acid (IDA)-type adsorbent is prepared at the one end of a capillary by covalently bonding IDA to the monolithic rods of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate). Cu(II) is later introduced to the support via the interaction with IDA. By this means, polymer monolithic immobilized metal affinity chromatography (IMAC) materials are prepared. With such a column, IMAC for on-line concentration and capillary electrophoresis (CE) for the subsequent analysis are hyphenated for the analysis of peptides and proteins. The reproducibility of such a column has been proved good with relative standard deviations (RSDs) of dead time of less than 5% for injection-to-injection and 12% for column-to-column (n = 3). Through application on the analysis of standard peptides and real protein samples, such a technique has shown promising in proteome study.
Resumo:
2-(9-Carbazole)-ethyl-chloroformate (CEOC), a novel pre-column fluorescence labeling reagent, has been synthesized and applied for the derivatization of phenols. Taken phenol, p-chlorophenol, 2,5-dimethylphenol, 2,4-dichlorophenol and 1,4-dihydroxybenzene as testing standards, the effects of derivatization conditions, such as pH of borate buffer, reaction time and fluorescent tagging reagent concentration, have been systematically studied. Under the optimized conditions, CEOC reacts readily with the phenols to form stable derivatives with excitation and emission wavelengths, respectively, at 293 and 360 nm. The single step derivatization reaction could be finished within 20 min even at room temperature. Such a method has been successfully applied to the analysis of phenols in printing ink by high-performance liquid chromatography. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Based on the mass balance equations of solute transfer in the radial chromatographic column, the theoretical expression to describe the column efficiency and shape of elution profile is obtained under linear isotherm case. Moreover, the tendency for the variation of column efficiency and symmetry of peak profile is systematically discussed. The results showed that in radial chromatography the relationship between the column efficiency and volumetric flow rate is similar with that relationship in axial chromatography; relatively high column efficiency still can be obtained under high flow rate in radial chromatography. Accompanying the increase of retention factor of solutes and injection time, the column efficiency decreases monotonously. The effect of column diameter and column length on the column efficiency interfere with each other. It is more advantageous to increase the column efficiency by applying columns with larger column diameter and shorter column length. According to the discussion of the effect of diffusion on the column efficiency, radial chromatography is proved to be suitable for the separation of samples with relatively high diffusion coefficient, which predicts its obvious advantage in the preparative separation of samples such as proteins and DNA.
Resumo:
The extract of Adinandra nitida leaves, named as Shiyacha in China, was studied by high performance liquid chromatography (HPLC)-ultraviolet detection-electrospray ionisation (ESI) tandem mass spectrometry (MS). Under the optimized condition, the analysis could be finished in 45 min on a Hypersil C18 column combined with negative ion detection using information-dependent acquisition (IDA) mode of a Q TRAP (TM) instrument. Six flavonoids were identified as epicatechin, rhoifolin, apigenin, quercitrin, camellianin A, and camellianin B among which rhoifolin was for the first time found in Shiyacha. And the fragment pathways of these flavonoids were elucidated. Furthermore, with epicatechin, rhoifolin, and apigenin as markers, the quality control method for Shiyacha and its relevant product was firstly established. Calibration linearity was good (R-2 > 0.9992) over a three to four orders of magnitude concentration range with an S/N = 3 detection limit of 2.5 ng. (c) 2004 Elsevier B.V. All rights reserved.
Resumo:
The estrogenic activity of the Chinese herb kudzu root was investigated by a recombinant yeast screening assay (YES). Isoflavones are the main components in the plant, of which puerarin is the most abundant one. The kudzu root extract was separated into four fractions according to the polarity. The crude extract and its sub-fractions, except the water fraction, showed clear estrogenic activity and the potencies were in the range of 10(-3) to 10(-1) g/l. The ligand potency was used to compare the estrogenic activity of these fractions. The crude extract and its sub-fractions were further analyzed by high performance liquid chromatography (HPLC) to correlate the activity and the active components. Bioassay and chemical analysis showed that theoretical estrogenic activity expressed as equivalent 17 beta-estradiol concentration or the cumulative effects are comparable to that experimentally determined by YES. The results showed that the high content of isoflavones as well as the high estrogenic activity could make kudzu root extract an interesting candidate for hormone replacement therapy. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
A method with carbon nanotubes functioning both as the adsorbent of solid-phase extraction (SPE) and the matrix for matrix assisted laser desorption/ ionization mass spectrometry (MALDI-MS) to analyze small molecules in solution has been developed. In this method, 10 muL suspensions of carbon nanotubes in 50% (vol/vol) methanol were added to the sample solution to extract analytes onto surface of carbon nanotubes because of their dramatic hydrophobicity. Carbon nanotubes in solution are deposited onto the bottom of tube with centrifugation. After removing the supernatant fluid, carbon nanotubes are suspended again with dispersant and pipetted directly onto the sample target of the MALDI-MS to perform a mass spectrometric analysis. It was demonstrated by analysis of a variety of small molecules that the resolution of peaks and the efficiency of desorption/ ionization on the carbon nanotubes are better than those on the activated carbon. It is found that with the addition of glycerol and sucrose to the dispersant, the intensity, the ratio of signal to noise (S/N), and the resolution of peaks for analytes by mass spectrometry increased greatly. Compared with the previously reported method by depositing sample solution onto thin layer of carbon nanotubes, it is observed that the detection limit for analytes can be enhanced about 10 to 100 times due to solid-phase extraction of analytes in solution by carbon nanotubes. An acceptable result of simultaneously quantitative analysis of three analytes in solution has been achieved. The application in determining drugs spiked into urine has also been realized. (C) 2004 American Society for Mass Spectrometry.
Resumo:
Performance of comprehensive two-dimensional liquid chromatography system is greatly improved than we reported previously by using a silica monolithic column as for the second dimensional separation. Due to the increase of the elution speed on the second dimensional monolithic column, the first dimensional column efficiency and analysis rate can be greatly improved as comparing with conventionally second dimensional column. The developed system was applied to analysis of methanol extraction of two umbelliferae herbs Ligusticum chuanxiong Hort. and Angelica sinensis (Oliv.) Diels by using CN column as for the first dimensional separation and a silica monolithic ODS column for the second dimensional separation, and the obtained three-dimensional chromatograms were treated by normalization of peak heights with the value of the highest peak or setting a certain value using a software written in-house. It was observed that much more peaks for low-abundant components in TCM extract can clearly be detected here than we reported before, due to the large difference for the amount of components in TCMs' extract. With the above improvements in separation performance and data treatment, totally about 120 components in methanol extraction of Rhizoma chuanxiong and 100 in A. sinensis were separated with UV detection within 130 min. This result meant that both the number of peaks detected increase twice but the analysis time decease twice if comparing with the previously reported result. (c) 2005 Published by Elsevier B.V.
Resumo:
Modified nucleosides have been characterized as tumor markers for a number of malignant diseases. In order to use these markers in children, the age-dependence of the nucleoside levels in healthy children has to be established and taken into account in diagnostic decisions. In this study, the levels of 12 normal and modified nucleosides in urine of 166 healthy children and adolescents with an age between 1 day and 19 years are determined by reversed-phase HPLC, and age-dependent reference ranges are defined. The urinary nucleoside concentrations are related to the creatinine concentrations, which allows the use of randomly collected urine samples. All nucleoside levels in urine of children decrease with age, most pronounced during the first 4 years of life, and the age-dependence of the reference values of the individual nucleosides can be approximated by a mathematical function y = b(0) + b(1) (1/x) with the regression coefficients b(0) and b(1), the nucleoside levels y and the age x between 1 year and 19 years. In the very young children, the shifts in the nucleoside concentrations are more differentiated. Starting with low levels on the first day of life, the concentrations of all studied nucleosides rise up to an age of 1-2 months, when they reach their absolute maximum for all age periods, and then decrease. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Comprehensive two-dimensional gas chromatography (GC x GC) has attracted much attention for the analys is of complex samples. Even with a large peak capacity in GC x GC, peak overlapping is often met. In this paper, a new method was developed to resolve overlapped peaks based on the mass conservation and the exponentially modified Gaussian (EMG) model. Linear relationships between the calculated sigma, tau of primary peaks with the corresponding retention time (t(R)) were obtained, and the correlation coefficients were over 0.99. Based on such relationships, the elution profile of each compound in overlapped peaks could be simulated, even for the peak never separated on the second-dimension. The proposed method has proven to offer more accurate peak area than the general data processing method. (c) 2005 Elsevier B.V. All rights reserved.