925 resultados para ELECTROSPAY IONIZATION TANDEM MASS SPECTROMETRY(ESI-MSn)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work presented herein covers a broad range of research topics and so, in the interest of clarity, has been presented in a portfolio format. Accordingly, each chapter consists of its own introductory material prior to presentation of the key results garnered, this is then proceeded by a short discussion on their significance. In the first chapter, a methodology to facilitate the resolution and qualitative assessment of very large inorganic polyoxometalates was designed and implemented employing ion-mobility mass spectrometry. Furthermore, the potential of this technique for ‘mapping’ the conformational space occupied by this class of materials was demonstrated. These claims are then substantiated by the development of a tuneable, polyoxometalate-based calibration protocol that provided the necessary platform for quantitative assessments of similarly large, but unknown, polyoxometalate species. In addition, whilst addressing a major limitation of travelling wave ion mobility, this result also highlighted the potential of this technique for solution-phase cluster discovery. The second chapter reports on the application of a biophotovoltaic electrochemical cell for characterising the electrogenic activity inherent to a number of mutant Synechocystis strains. The intention was to determine the key components in the photosynthetic electron transport chain responsible for extracellular electron transfer. This would help to address the significant lack of mechanistic understanding in this field. Finally, in the third chapter, the design and fabrication of a low-cost, highly modular, continuous cell culture system is presented. To demonstrate the advantages and suitability of this platform for experimental evolution investigations, an exploration into the photophysiological response to gradual iron limitation, in both the ancestral wild type and a randomly generated mutant library population, was undertaken. Furthermore, coupling random mutagenesis to continuous culture in this way is shown to constitute a novel source of genetic variation that is open to further investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans les dernières années, les perturbateurs endocriniens ont été observés dans les rivières qui reçoivent des entrées importantes d’eaux usées. Parmi les perturbateurs endocriniens, les hormones stéroïdiennes naturelles et synthétiques sont des composés dont le potentiel d'imiter ou d'interférer avec les fonctions hormonales normales (développement, croissance et reproduction), est reconnu même au niveau ultra-traces (ng L-1). Bien que les hormones conjuguées soient moins actives que les hormones libres, elles peuvent être clivées et redevenir libres une fois exposées aux processus microbiens avant ou pendant le traitement des eaux usées. En raison de la nécessité d'identifier et de quantifier ces composés dans l'eau, une nouvelle méthode, entièrement automatisée, a été développée pour la détermination simultanée des deux formes de plusieurs hormones stéroïdiennes (conjuguées et libres) dans les matrices d'eau et dans l’urine des femmes. La méthode est basée sur l'extraction en phase solide couplée en ligne à la chromatographie liquide et la spectrométrie de masse en tandem (SPE-LC-MS/MS). Plusieurs paramètres ont été évalués dans le but d'optimiser l'efficacité de la méthode, tels que le type et le débit de la phase mobile, des différentes colonnes de SPE et de chromatographie, ainsi que différentes sources et modes d'ionisation des échantillons pour la MS. La méthode démontre une bonne linéarité (R2 > 0.993), ainsi qu'une précision avec un coefficient de variance inférieure à 10%. Les limites de quantification varient d’un minimum de 3 à 15 ng L-1 pour un volume d'injection entre 1 mL et 5 mL et le recouvrement des composés varie de 72 % à 117 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A human genome contains more than 20 000 protein-encoding genes. A human proteome, instead, has been estimated to be much more complex and dynamic. The most powerful tool to study proteins today is mass spectrometry (MS). MS based proteomics is based on the measurement of the masses of charged peptide ions in a gas-phase. The peptide amino acid sequence can be deduced, and matching proteins can be found, using software to correlate MS-data with sequence database information. Quantitative proteomics allow the estimation of the absolute or relative abundance of a certain protein in a sample. The label-free quantification methods use the intrinsic MS-peptide signals in the calculation of the quantitative values enabling the comparison of peptide signals from numerous patient samples. In this work, a quantitative MS methodology was established to study aromatase overexpressing (AROM+) male mouse liver and ovarian endometriosis tissue samples. The workflow of label-free quantitative proteomics was optimized in terms of sensitivity and robustness, allowing the quantification of 1500 proteins with a low coefficient of variance in both sample types. Additionally, five statistical methods were evaluated for the use with label-free quantitative proteomics data. The proteome data was integrated with other omics datasets, such as mRNA microarray and metabolite data sets. As a result, an altered lipid metabolism in liver was discovered in male AROM+ mice. The results suggest a reduced beta oxidation of long chain phospholipids in the liver and increased levels of pro-inflammatory fatty acids in the circulation in these mice. Conversely, in the endometriosis tissues, a set of proteins highly specific for ovarian endometrioma were discovered, many of which were under the regulation of the growth factor TGF-β1. This finding supports subsequent biomarker verification in a larger number of endometriosis patient samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work outlined in this dissertation will allow biochemists and cellular biologists to characterize polyubiquitin chains involved in their cellular environment by following a facile mass spectrometric based workflow. The characterization of polyubiquitin chains has been of interest since their discovery in 1984. The profound effects of ubiquitination on the movement and processing of cellular proteins depend exclusively on the structures of mono and polyubiquitin modifications anchored or unanchored on the protein within the cellular environment. However, structure-function studies have been hindered by the difficulty in identifying complex chain structures due to limited instrument capabilities of the past. Genetic mutations or reiterative immunoprecipitations have been used previously to characterize the polyubiquitin chains, but their tedium makes it difficult to study a broad ubiquitinome. Top-down and middle-out mass spectral based proteomic studies have been reported for polyubiquitin and have had success in characterizing parts of the chain, but no method to date has been successful at differentiating all theoretical ubiquitin chain isomers (ubiquitin chain lengths from dimer to tetramer alone have 1340 possible isomers). The workflow presented here can identify chain length, topology and linkages present using a chromatographic-time-scale compatible, LC-MS/MS based workflow. To accomplish this feat, the strategy had to exploit the most recent advances in top-down mass spectrometry. This included the most advanced electron transfer dissociation (ETD) activation and sensitivity for large masses from the orbitrap Fusion Lumos. The spectral interpretation had to be done manually with the aid of a graphical interface to assign mass shifts because of a lack of software capable to interpret fragmentation across isopeptide linkages. However, the method outlined can be applied to any mass spectral based system granted it results in extensive fragmentation across the polyubiquitin chain; making this method adaptable to future advances in the field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comets harbor the most pristine material in our solar system in the form of ice, dust, silicates, and refractory organic material with some interstellar heritage. The evolved gas analyzer Cometary Sampling and Composition (COSAC) experiment aboard Rosetta's Philae lander was designed for in situ analysis of organic molecules on comet 67P/Churyumov-Gerasimenko. Twenty-five minutes after Philae's initial comet touchdown, the COSAC mass spectrometer took a spectrum in sniffing mode, which displayed a suite of 16 organic compounds, including many nitrogen-bearing species but no sulfur-bearing species, and four compounds-methyl isocyanate, acetone, propionaldehyde, and acetamide-that had not previously been reported in comets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Exosomes released by myeloid-derived suppressor cells (MDSC) are 30 nm in diameter extracellular vesicles that have been shown to carry biologically active proteins as well as ubiquitin molecules. Ubiquitin is known to have many functions, including involvement in the formation of exosomes, although the exact role is highly contested. In the study reported here, the proteome and ubiquitome of MDSC exosomes has been investigated by bottom-up proteomics techniques. This report identifies more than 1000 proteins contained in the MDSC exosome cargo and 489 sites of ubiquitination in more than 300 ubiquitinated proteins based on recognition of glycinylglycine tagged peptides without antibody enrichment. This has allowed extensive chemical and biological characterization of the ubiquitinated cohort compared to that of the entire protein cargo to support hypotheses on the role of ubiquitin in exosomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The elemental analysis of soil is useful in forensic and environmental sciences. Methods were developed and optimized for two laser-based multi-element analysis techniques: laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and laser-induced breakdown spectroscopy (LIBS). This work represents the first use of a 266 nm laser for forensic soil analysis by LIBS. Sample preparation methods were developed and optimized for a variety of sample types, including pellets for large bulk soil specimens (470 mg) and sediment-laden filters (47 mg), and tape-mounting for small transfer evidence specimens (10 mg). Analytical performance for sediment filter pellets and tape-mounted soils was similar to that achieved with bulk pellets. An inter-laboratory comparison exercise was designed to evaluate the performance of the LA-ICP-MS and LIBS methods, as well as for micro X-ray fluorescence (μXRF), across multiple laboratories. Limits of detection (LODs) were 0.01-23 ppm for LA-ICP-MS, 0.25-574 ppm for LIBS, 16-4400 ppm for µXRF, and well below the levels normally seen in soils. Good intra-laboratory precision (≤ 6 % relative standard deviation (RSD) for LA-ICP-MS; ≤ 8 % for µXRF; ≤ 17 % for LIBS) and inter-laboratory precision (≤ 19 % for LA-ICP-MS; ≤ 25 % for µXRF) were achieved for most elements, which is encouraging for a first inter-laboratory exercise. While LIBS generally has higher LODs and RSDs than LA-ICP-MS, both were capable of generating good quality multi-element data sufficient for discrimination purposes. Multivariate methods using principal components analysis (PCA) and linear discriminant analysis (LDA) were developed for discriminations of soils from different sources. Specimens from different sites that were indistinguishable by color alone were discriminated by elemental analysis. Correct classification rates of 94.5 % or better were achieved in a simulated forensic discrimination of three similar sites for both LIBS and LA-ICP-MS. Results for tape-mounted specimens were nearly identical to those achieved with pellets. Methods were tested on soils from USA, Canada and Tanzania. Within-site heterogeneity was site-specific. Elemental differences were greatest for specimens separated by large distances, even within the same lithology. Elemental profiles can be used to discriminate soils from different locations and narrow down locations even when mineralogy is similar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sampling and preconcentration techniques play a critical role in headspace analysis in analytical chemistry. My dissertation presents a novel sampling design, capillary microextraction of volatiles (CMV), that improves the preconcentration of volatiles and semivolatiles in a headspace with high throughput, near quantitative analysis, high recovery and unambiguous identification of compounds when coupled to mass spectrometry. The CMV devices use sol-gel polydimethylsiloxane (PDMS) coated microglass fibers as the sampling/preconcentration sorbent when these fibers are stacked into open-ended capillary tubes. The design allows for dynamic headspace sampling by connecting the device to a hand-held vacuum pump. The inexpensive device can be fitted into a thermal desorption probe for thermal desorption of the extracted volatile compounds into a gas chromatography-mass spectrometer (GC-MS). The performance of the CMV devices was compared with two other existing preconcentration techniques, solid phase microextraction (SPME) and planar solid phase microextraction (PSPME). Compared to SPME fibers, the CMV devices have an improved surface area and phase volume of 5000 times and 80 times, respectively. One (1) minute dynamic CMV air sampling resulted in similar performance as a 30 min static extraction using a SPME fiber. The PSPME devices have been fashioned to easily interface with ion mobility spectrometers (IMS) for explosives or drugs detection. The CMV devices are shown to offer dynamic sampling and can now be coupled to COTS GC-MS instruments. Several compound classes representing explosives have been analyzed with minimum breakthrough even after a 60 min. sampling time. The extracted volatile compounds were retained in the CMV devices when preserved in aluminum foils after sampling. Finally, the CMV sampling device were used for several different headspace profiling applications which involved sampling a shipping facility, six illicit drugs, seven military explosives and eighteen different bacteria strains. Successful detection of the target analytes at ng levels of the target signature volatile compounds in these applications suggests that the CMV devices can provide high throughput qualitative and quantitative analysis with high recovery and unambiguous identification of analytes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Liquid chromatography coupled with mass spectrometry is one of the most powerful tools in the toxicologist’s arsenal to detect a wide variety of compounds from many different matrices. However, the huge number of potentially abused substances and new substances especially designed as intoxicants poses a problem in a forensic toxicology setting. Most methods are targeted and designed to cover a very specific drug or group of drugs while many other substances remain undetected. High resolution mass spectrometry, more specifically time-of-flight mass spectrometry, represents an extremely powerful tool in analysing a multitude of compounds not only simultaneously but also retroactively. The data obtained through the time-of-flight instrument contains all compounds made available from sample extraction and chromatography, which can be processed at a later time with an improved library to detect previously unrecognised compounds without having to analyse the respective sample again. The aim of this project was to determine the utility and limitations of time-of-flight mass spectrometry as a general and easily expandable screening method. The resolution of time-of-flight mass spectrometry allows for the separation of compounds with the same nominal mass but distinct exact masses without the need to separate them chromatographically. To simulate the wide variety of potentially encountered drugs in such a general screening method, seven drugs (morphine, cocaine, zolpidem, diazepam, amphetamine, MDEA and THC) were chosen to represent this variety in terms of mass, properties and functional groups. Consequently, several liquid-liquid and solid phase extractions were applied to urine samples to determine the most general suitable and unspecific extraction. Chromatography was optimised by investigating the parameters pH, concentration, organic solvent and gradient of the mobile phase to improve data obtained by the time-of-flight instrument. The resulting method was validated as a qualitative confirmation/identification method. Data processing was automated using the software TargetAnalysis, which provides excellent analyte recognition according to retention time, exact mass and isotope pattern. The recognition of isotope patterns allows excellent recognition of analytes even in interference rich mass spectra and proved to be a good positive indicator. Finally, the validated method was applied to samples received from the A& E Department of Glasgow Royal Infirmary in suspected drug abuse cases and samples received from the Scottish Prison Service, which we received from their own prevalence study targeting drugs of abuse in the prison population. The obtained data was processed with a library established in the course of this work.