945 resultados para Droplet etching
Resumo:
In this work poly(hydroxybutyrate/poly(vinyl butyral)- co-(vinyl alcohol)-co(vinyl acetate) (or ethylene propylene diene monomer rubber) blends were prepared by conventional processing techniques (extrusion and injection moulding). A droplet type morphology was obtained for P(3HB)/PVB blends whereas P(3HB)/EPDM blends presented some extent of co-continuous morphology. In addition, rubbery domains were much smaller in the case of PVB. These differences in morphology are discussed taking into account solubility parameters and rheological behaviours of each component. For both blends, the increase of elastomer ratio led to a decrease of Young's modulus but an increase in elongation at break and impact strength. The latter increased more in the case of P(3HB)/EPDM blends although the rubbery domains were larger. These results are explained in the light of the glass transition of the rubber and the presence of plasticizer in the case of PVB. The addition of elastomer also resulted in an increase of P(3HB) biodegradation rate, especially in the case of EPDM. It is assumed that, in this case, the size and morphology of the rubbery domains induce a geometrical modification of the erosion front which leads to an increase of the interface between P(3HB) phase and the degradation medium and consequently to an apparently faster biodegradation kinetics of PHB/rubber blends. Copyright (C) 2011 Society of Chemical Industry
Resumo:
Implant topography is an important factor that influences many cell types. To understand the role of topography in the inflammatory events, we evaluated the response of human gingival fibroblasts (HGFs) by the release pattern of cytokines. HGFs were cultured on Ti discs for 24 and 48 h. Four different surface treatments were used: machining method (turned), blasting followed by an acid-etching method (BAE), oxidative nanopatterning (ON) method, and an association of blasting followed by an acid-etching plus oxidative nanopatterning (BAE+ON) method. Extracellular levels of IL-6, IL-8, transforming growth factor beta (TGF-beta), IL-4, and IL-10 were measured by enzyme-linked immunosorbant assay. Increased levels of IL-6 and IL-8 were observed in all surfaces after 24 h which decreased after 48 h. BAE, ON, and BAE+ON surfaces showed a reduction in IL-6 levels compared with the turned after 48 h (p < 0.05). On one hand, IL-8 production was lower in BAE+ON in comparison to the turned surface (p < 0.05). On the other hand, IL-4 showed increased levels with 48 h, which were significantly different between turned, BAE, and ON surfaces, but not with BAE+ON. Additionally, TGF-beta and IL-10 production were not detected. This study indicates that nanotopography might be important in the modulation of the inflammatory response in cultured HGFs. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A 100A:2629-2636, 2012.
Resumo:
The aim of this study was to evaluate the resindentin bonds of two simplified etch-and-rinse adhesive after simulated cariogenic and inhibited cariogenic challenge in situ. Dental cavities (4 mm wide, 4 mm long, and 1.5 mm deep) were prepared in 60 bovine teeth with enamel margins. Restorations were bonded with either adhesive Adper Single Bond 2 (3MESPE) or Optibond Solo Plus (Kerr). Forty restorations were included in an intra-oral palatal appliance that was used for 10 adult volunteers while the remaining 20 dental blocks were not submitted to any cariogenic challenge [NC group] and tested immediately. For the simulated cariogenic challenge [C+DA], each volunteer dropped 20% sucrose solution onto all blocks four times a day during 14 days and distilled water twice a day. In the inhibited cariogenic challenge group [C + FA], the same procedure was done, but slurry of fluoride dentifrice (1.100 ppm) was applied instead of water. The restored bovine blocks were sectioned to obtain a slice for cross-sectional Vickers microhardness evaluation and resindentin bonded sticks (0.8 mm2) for resindentin microtensile evaluation. Data were evaluated by two-way ANOVA and Tukey's tests (a = 0.05). Statistically lower microhardness values and degradation of the resindentin bonds were only found in the C + DW group for both adhesives. The in situ model seems to be a suitable short-term methodology to investigate the degradation of the resindentin bonds under a more realistic condition. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 100B: 14661471, 2012.
Resumo:
In this letter, we describe a simple and effective technique to prevent evaporation in liquid-core photonic crystal fibers (PCFs). The technique consists of using a micropipette to deploy a micro-droplet of an ultraviolet curable polymer adhesive in both core inputs. After it is cured, the adhesive creates sealing polymer plugs with quite satisfactory insertion loss (overall optical transmission of about 15%). Processed fibers remained liquid-filled for at least six weeks. From a practical point of view, we conducted a supercontinuum generation experiment in a water-core PCF to demonstrate a 120-minute spectral width stability and the ability to withstand at least 3-mW average power at the sealed fiber input. Similar experiments carried out with nonsealed fibers produced supercontinuum spectra lasting no longer than 10 minutes, with average powers kept below 0.5 mW to avoid thermally induced evaporation.
Resumo:
Aim: To assess the immediate influence of dentine bonding systems (DBS) associated with 2% chlorhexidine digluconate (CHX) on glass-fibre post-bond strength to root dentine, in terms of coronal, middle and apical thirds. Methodology: Sixty bovine roots were root filled and randomly assigned to 1 of 6 groups (n = 10): SBMP (3-step etch-and-rinse system, Scotchbond Multi-Purpose), SB (2-step etch-and-rinse system, Single Bond 2), SE (2-step self-etching system, Clearfil SE Bond) and SBMP-CHX, SB-CHX and SE-CHX, respectively, associated with CHX. For all groups, a glassfibre post was luted with a dual-cure resin cement, RelyX ARC. After 7-day storage, specimens were subjected to the push-out test. Failure modes were analysed under optical microscopy (40x). Bond strength values were statistically analysed by two-way ANOVA and Bonferroni tests (P < 0.05). Results: The effect of DBS was significant (P < 0.05), and SE reached higher bond strength in comparison with the other DBS tested. CHX association did not show improvement with any DBS (P > 0.05); rather, it negatively affected SE, which was detected for all thirds. There was no difference between thirds (P > 0.05), except for the SE-CHX, which presented lower values for the apical third (P < 0.05). Adhesive cement/dentine adhesive failure was predominant for all groups. CHX did not influence the failure mode for any DBS (P > 0.05). Conclusions: The performance of the dentine bonding systems was material dependent. CHX did not improve immediate bond strength; however, CHX negatively affected the bond strength of the self-etching system, especially in the third apical
Resumo:
The purpose of the present study was to evaluate in vivo the failure rate of metallic brackets bonded with two orthodontic composites. Nineteen patients with ages ranging from 10.5 to 38.7 years needing corrective orthodontic treatment were selected for study. The enamel surfaces from second premolars to second premolars were treated with Transbond Plus-Self Etching Primer (3M Unitek). Next, 380 orthodontic brackets were bonded on maxillary and mandibular teeth, as follows: 190 with Transbond XT composite (3M Unitek) (control) and 190 with Transbond Plus Color Change (3M Unitek) (experimental) in contralateral quadrants. The bonded brackets were light cured for 40 s, and initial alignment archwires were inserted. Bond failure rates were recorded over a six-month period. At the end of the evaluation, six bond failures occurred, three for each composite. Kaplan-Meyer method and log-rank test (Mantel-Cox) was used for statistical analysis, and no statistically significant difference was found between the materials (p=0.999). Both Transbond XT and Transbond Plus Color Change composites had low debonding rates over the study period.
Resumo:
The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate (CHX) on immediate bond strength of etch-and-rinse adhesive to sound (SD) and caries-affected (CAD) primary dentin compared with permanent dentin. Flat dentin surfaces from 20 primary molars (Pri) and 20 permanent molars (Perm) were assigned to 8 experimental groups (n=5) according to tooth type (Pri or Perm), dentin condition (SD or CAD - pH-cycling for 14 days) and treatment (control - C or 60 s application of 2% CHX solution after acid etching - CHX). The bonding system (Adper Single Bond 2) was applied according to manufacturer's instructions followed by resin composite application (Filtek Z250). After 24 h water storage, specimens with cross-section area of 0.8 mm² were prepared for being tested under microtensile test (1 mm/min). Data were submitted to ANOVA and Tukey's post hoc test (α=0.05). Failure mode was evaluated using a stereomicroscope at ×400. Treatment with CHX did not result in higher bond strength values than no pre-treatment (C groups), independently of tooth type. Primary teeth and caries-affected dentin showed significantly lower (p<0.05) bond strength means compared with permanent teeth and sound dentin, respectively. Predominance of adhesive/mixed failure was observed for all groups. CHX did not influence the immediate bond strength to sound or caries-affected dentin of primary and permanent teeth.
Resumo:
OBJECTIVES: The aim of this study was to evaluate in vivo the bonding of metallic orthodontic brackets with different adhesive systems. MATERIAL AND METHODS: Twenty patients (10.5-15.1 years old) who had sought corrective orthodontic treatment at a University Orthodontic Clinic were evaluated. Brackets were bonded from the right second premolar to the left second premolar in the upper and lower arches using: Orthodontic Concise, conventional Transbond XT, Transbond XT without primer, and Transbond XT associated with Transbond Plus Self-etching Primer (TPSEP). The 4 adhesive systems were used in all patients using a split-mouth design; each adhesive system was used in one quadrant of each dental arch, so that each group of 5 patients received the same bonding sequence. Initial archwires were inserted 1 week after bracket bonding. The number of bracket failures for each adhesive system was quantified over a 6-month period. RESULTS: The number of debonded brackets was: 8- Orthodontic Concise, 2- conventional Transbond XT, 9- Transbond XT without primer, and 1- Transbond XT + TPSEP. By using the Kaplan-Meier methods, statistically significant differences were found between the materials (p=0.0198), and the Logrank test identified these differences. Conventional Transbond XT and Transbond XT + TPSEP adhesive systems were statistically superior to Orthodontic Concise and Transbond XT without primer (p<0.05). There was no statistically significant difference between the dental arches (upper and lower), between the dental arch sides (right and left), and among the quadrants. CONCLUSIONS: The largest number of bracket failures occurred with Orthodontic Concise and Transbond XT without primer systems and few bracket failures occurred with conventional Transbond XT and Transbond XT+TPSEP. More bracket failures were observed in the posterior region compared with the anterior region.
Resumo:
A detailed numerical simulation of ethanol turbulent spray combustion on a rounded jet flame is pre- sented in this article. The focus is to propose a robust mathematical model with relatively low complexity sub- models to reproduce the main characteristics of the cou- pling between both phases, such as the turbulence modulation, turbulent droplets dissipation, and evaporative cooling effect. A RANS turbulent model is implemented. Special features of the model include an Eulerian– Lagrangian procedure under a fully two-way coupling and a modified flame sheet model with a joint mixture fraction– enthalpy b -PDF. Reasonable agreement between measured and computed mean profiles of temperature of the gas phase and droplet size distributions is achieved. Deviations found between measured and predicted mean velocity profiles are attributed to the turbulent combustion modeling adopted
Resumo:
[EN] This paper deals with the relief generation in Ourense, an interior territory of the Galicia Country, at NW Spain, after the breakdown of Pangea 200 million years ago. The rupture of supercontinent causes the main effects in the outer part of Galicia, the present coast line and the shelf, but also the inner parts of Galicia where the landscape changes dramatically mainly ruled by fluvial incision connected with uprising, (orogenic, epirogenic, or isostatic origin), or even with eustatic oscillations, that shaped the previous old mesozoic landscape. Various things complicate the correct understanding of Galician geomorphology:1) the prevalent hercynian structure, (presumably reactivated during the Alpine Orogeny), causes that the epigenic processes, (fluvial, glaciar, marine and etching), acting on Galicia from Mesozoic to present times, produce end forms identified erroneously at the previous literature as tectonic and not as etch forms profiting from lithological or structural contrasts. 2) the common morphotectonic model accepted by all previous researchers establishes for the whole of Galicia a blocky pattern, (horst and graben like), due to extensional tectonic regime. This model is proved as no longer valid because the Galician tertiary basins, even were described at the past as graben depressions never have this origin. 3) big differences exist between the north and western sides of Galicia that show contrasted tectonic regime: compressional (with forms as the so called raised platforms), at the northern coast border, and extensional (with forms so typical as the Rias), at the western side. The study area is located at the confluence of two tectonic domains where the above mentioned effects are coincidents and specially well showed through different effects: prominent assimetry of fluvial captures (west facing), pronounced river incision and different kinds of tertiary basins: either strike slipe faults (Maceda, Xinzo de Limia, etc), or overslipped by inverse faults, (Quiroga, A Rúa, etc.), or even corresponding with depressions never, (or anywise passively), affected by tectonic movements, (Monforte). The paper include a detailed inventory of surfaces and terrace levels and their incision sequence which allow stablish a relative chronology of geomorphic evolution at this area of NW Spain during meso-cainozoic times.
Resumo:
This thesis deals with two important research aspects concerning radio frequency (RF) microresonators and switches. First, a new approach for compact modeling and simulation of these devices is presented. Then, a combined process flow for their simultaneous fabrication on a SOI substrate is proposed. Compact models for microresonators and switches are extracted by applying mathematical model order reduction (MOR) to the devices finite element (FE) description in ANSYS c° . The behaviour of these devices includes forms of nonlinearities. However, an approximation in the creation of the FE model is introduced, which enables the use of linear model order reduction. Microresonators are modeled with the introduction of transducer elements, which allow for direct coupling of the electrical and mechanical domain. The coupled system element matrices are linearized around an operating point and reduced. The resulting macromodel is valid for small signal analysis around the bias point, such as harmonic pre-stressed analysis. This is extremely useful for characterizing the frequency response of resonators. Compact modelling of switches preserves the nonlinearity of the device behaviour. Nonlinear reduced order models are obtained by reducing the number of nonlinearities in the system and handling them as input to the system. In this way, the system can be reduced using linear MOR techniques and nonlinearities are introduced directly in the reduced order model. The reduction of the number of system nonlinearities implies the approximation of all distributed forces in the model with lumped forces. Both for microresonators and switches, a procedure for matrices extraction has been developed so that reduced order models include the effects of electrical and mechanical pre-stress. The extraction process is fast and can be done automatically from ANSYS binary files. The method has been applied for the simulation of several devices both at devices and circuit level. Simulation results have been compared with full model simulations, and, when available, experimental data. Reduced order models have proven to conserve the accuracy of finite element method and to give a good description of the overall device behaviour, despite the introduced approximations. In addition, simulation is very fast, both at device and circuit level. A combined process-flow for the integrated fabrication of microresonators and switches has been defined. For this purpose, two processes that are optimized for the independent fabrication of these devices are merged. The major advantage of this process is the possibility to create on-chip circuit blocks that include both microresonators and switches. An application is, for example, aswitched filter bank for wireless transceiver. The process for microresonators fabrication is characterized by the use of silicon on insulator (SOI) wafers and on a deep reactive ion etching (DRIE) step for the creation of the vibrating structures in single-crystal silicon and the use of a sacrificial oxide layer for the definition of resonator to electrode distance. The fabrication of switches is characterized by the use of two different conductive layers for the definition of the actuation electrodes and by the use of a photoresist as a sacrificial layer for the creation of the suspended structure. Both processes have a gold electroplating step, for the creation of the resonators electrodes, transmission lines and suspended structures. The combined process flow is designed such that it conserves the basic properties of the original processes. Neither the performance of the resonators nor the performance of the switches results affected by the simultaneous fabrication. Moreover, common fabrication steps are shared, which allows for cheaper and faster fabrication.
Resumo:
The growing interest for Integrated Optics for sensing, telecommunications and even electronics is driving research to find solutions to the new challenges issued by a more and more fast, connected and smart world. This thesis deals with the design, the fabrication and the characterisation of the first prototypes of Microring Resonators realised using ion implanted Lithium Niobate (LiNbO3) ridge waveguides. Optical Resonator is one among the most important devices for all tasks described above. LiNbO3 is the substrate commonly used to fabricate optical modulators thanks to its electro-optic characteristics. Since it is produced in high quantity, good quality and large wafers its price is low compared to other electro-optic substrate. We propose to use ion implantation as fabrication technology because in the other way standard optical waveguides realised in LiNbO3 by Proton Exchange (PE) or metal diffusion do not allow small bending radii, which are necessary to keep the circuit footprint small. We will show in fact that this approach allows to fabricate waveguides on Lithium Niobate that are better than PE or metal diffused waveguides as it allows smaller size devices and tailoring of the refractive index profile controlling the implantation parameters. Moreover, we will show that the ridge technology based on enhanced etching rate via ion implantation produces a waveguide with roughness lower than a dry etched one. Finally it has been assessed a complete technological process for fabrication of Microring Resonator devices in Lithium Niobate by ion implantation and the first prototypes have been produced.
Resumo:
Lipolysis and oxidation of lipids in foods are the major biochemical and chemical processes that cause food quality deterioration, leading to the characteristic, unpalatable odour and flavour called rancidity. In addition to unpalatability, rancidity may give rise to toxic levels of certain compounds like aldehydes, hydroperoxides, epoxides and cholesterol oxidation products. In this PhD study chromatographic and spectroscopic techniques were employed to determine the degree of lipid oxidation in different animal products and its relationship with technological parameters like feeding fat sources, packaging, processing and storage conditions. To achieve this goal capillary gas chromatography (CGC) was employed not only to determine the fatty acids profile but also, after solid phase extraction, the amount of sterols (cholesterol and phytosterols) and cholesterol oxidation products (COPs). To determine hydroperoxides, primary products of oxidation and quantify secondary products UV/VIS absorbance spectroscopy was applied. Beef and pork meat in this study were analysed. In actual fact, lipid oxidation is a major deterioration reaction in meat, meat products and results in adverse changes in the colour, flavour, texture of meat and develops different compounds which should be a risk to human health as oxysterols. On beef and pork meat, a study of lipid fraction during storage was carried out to evaluate its shelf-life and some nutritional features life saturated/unsaturated fatty acids ratio and sterols content, in according to the interest that has been growing around functional food in the last years. The last part of this research was focused on the study of lipid oxidation in emulsions. In oil-in-water emulsions antioxidant activity of 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) was evaluated. The rates of lipid oxidation of 1.0% stripped soybean oil-in-water emulsions with DOPC were followed by monitoring lipid hydroperoxide and hexanal as indicators of primary and secondary oxidation products and the droplet surface charge or zeta potential (ζ) of the emulsions with varying concentrations of DOPC were tested. This manuscript reports the main results obtained in the three activities briefly summarized as follows: 1. study on effects of feeding composition on the photoxidative stability of lipids from beef meat, evaluated during storage under commercial retail conditions; 2. evaluation of effects of diets and storage conditions on the oxidative stability of pork meat lipids; 3. study on oxidative behavior of DOPC in stripped soybean oil-in-water emulsions stabilized by nonionic surfactant.
Resumo:
Im Rahmen dieser Arbeit wurde am System Polyethylenoxid / Polypropylenoxid (PEO / PPO) der Einfluß von Copolymeren auf die Grenzflächenspannung Sigma von Homopolymerblends untersucht. Als Additive dienten Triblockcopolymere EO-block-PO-block-EO bzw. PO-block-EO-block-PO, Diblockcopolymere S-block-EO sowie statistische Copolymere EO-ran-PO. Die Additive wurden so ausgewählt, daß sich Paare von Additiven jeweils in genau einer Eigenschaft (Zusammensetzung, Kettenlänge, Blockanordnung) unterscheiden, in allen anderen Parametern jedoch vergleichbar sind. Die Grenzflächenspannung wurde experimentell mit Hilfe der Pendant-Drop-Methode in Abhängigkeit von der Temperatur ermittelt, wobei das Polymer mit der höheren Dichte, PEO, die Tropfenphase und PPO die Matrixphase bildet. Das Additiv wurde bei Messung der Grenzflächenspannung der ternären Systeme in unterschiedlichen Konzentrationen entweder einer oder beiden Homopolymerphasen zugegeben. Die Konzentrationsabhängigkeit von Sigma lässt sich sowohl mit dem Modell von Tang und Huang als auch mit einem Langmuir-analogen Ansatz gut beschreiben.Um den Zusammenhang zwischen sigma und dem Phasenverhalten zu untersuchen, wurden für einige der ternären Systeme Trübungskurven bei 100°C aufgenommen. Der Vergleich zwischen den Phasendiagrammen und den korrespondierenden Werten von sigma weist darauf hin, dass ein Additiv sigma gerade dann wirksam reduziert, wenn es einem Homopolymer zugefügt wird, mit dem es nur begrenzt verträglich ist, da dann die Triebkraft zur Anlagerung an der Grenzfläche besonders ausgeprägt ist. Das bereits bekannte Phänomen, wonach der Wert der Grenzflächenspannung davon abhängig sein kann, in welcher der Phasen das Additiv zu Beginn der Messung vorliegt, wurde ausführlich untersucht. Es wird angenommen, dass das System nicht in jedem Fall das thermodynamische Gleichgewicht erlangt und der beobachtete Effekt auf das Erreichen stationärer Zustände zurückzuführen ist. Dieses Verhalten kann mit einem Modell beschrieben werden, in welches das Viskositätsverhältnis der Homopolymere sowie der Verteilungskoeffizient des Copolymers zwischen den Homopolymerphasen eingehen. Aus Löslichkeitsparametern wurde der binäre Wechselwirkungsparameter Chi PEO/PPO = 0.18 abgeschätzt und mit diesem die theoretischen Werte für sigma zwischen PEO und PPO nach den Modellen von Roe bzw. Helfand und Tagami berechnet. Der Vergleich mit den experimentellen Daten des binären Systems zeigt, dass beide Ansätze sigma-Werte liefern, die in der Größenordnung der experimentellen Daten liegen, hierbei erweist sich der Ansatz von Roe als besonders geeignet. Die Temperaturabhängigkeit der Grenzflächenspannung wird jedoch durch beide Ansätze unzutreffend wiedergegeben. Mit dem Modell von Helfand und Tagami wurden eine Grenzflächendicke von 7.9 à und das Dichteprofil der Grenzfläche berechnet. Für die Copolymere EO92PO56EO92 und S9EO22 (die Indices geben die Zahl der Monomereinheiten an) können die Grenzflächenüberschusskonzentrationen, die kritische Mizellenkonzentration sowie der einem Additivmolekül an der Grenzschicht zur Verfügung stehende Platz bestimmt werden.Der Vergleich unterschiedlicher Copolymere hinsichtlich ihrer Fähigkeit, sigma wirkungsvoll herabzusetzen, zeigt, dass im Fall von Triblockcopolymeren die Anordnung der Blöcke gegenüber der Zusammensetzung eine untergeordnete Rolle spielt. Mit zunehmender Kettenlänge nimmt die Effektivität als Compatibilizer sowohl bei Blockcopolymeren als auch bei statistischen Copolymeren zu.
Resumo:
In der vorliegenden Arbeit wurde die Morphologie von zweiphasigen Polymermischungen unter Scherung in situ mit Hilfe einer Kombination aus optischer Scherzelle, Durchlichtmikroskop und computergestützten CCD-Kamera untersucht. Als Modellblends dienten die unverträglichen, bei Raumtemperatur flüssigen Polymersysteme Polyisobutylen (PIB)/Polydimethylsiloxan (PDMS) (I) und Poly(dimethyl-co-methylphenyl)siloxan/PDMS (II). Alle Komponenten verhalten sich bei den verwendeten Scherraten newtonisch.Eine der wichtigsten Einflussgrößen für die Blendmorphologie ist die Grenzflächenspannung gamma 12. Sie wurde für I und II mit Hilfe der Methode der Tropfenrelaxation (dynamisch) als Funktion der Zeit bestimmt. Diese Methode erlaubt die Messung von gamma 12 für Tropfen der Phase A in B sowie von Tropfen B in A. Bei der Methode des hängenden Tropfens (statisch) muss der Tropfen aus der Phase mit der höheren Dichte bestehen. Wo der Vergleich der beiden Methoden möglich ist, stimmen die Ergebnisse für beide Systeme sehr gut überein. Bei II sind die aus der Tropfenrelaxation erhaltenen gamma 12-Werte der beiden komplementären Zusammensetzungen im Rahmen des Fehlers gleich, bei I zeigt ein PIB-Tropfen in PDMS einen um 40 % niedrigeren Wert als ein PDMS-Tropfen in PIB, dies wird auf die Diffusion von kurzkettigen Anteilen des PDMS in die Grenzschicht zurückgeführt. Die Grenzflächenspannung hängt also unter Umständen auch bei binären Systemen deutlich von der Zusammensetzung ab.Für II wurde die Blendmorphologie über den gesamten Zusammensetzungsbereich untersucht. Die häufig beobachteten cokontinuierlichen Strukturen treten bei keiner Zusammensetzung auf. Die Phaseninversion erkennt man in einer sprunghaften Änderung der Tropfengröße zwischen phiPDMS <= 0,400 und 0,500; zudem lässt sich die Zeitabhängigkeit der Radien durch Auftragung gegen das Produkt aus der Deformation und dem Quadrat des Volumenbruchs der Tropfenphase für 0 <= phiPDMS <= 0,400 sowie 0,500 <= phiPDMS <= 1 normieren. Für I und II wurde die Morphologieentwicklung bei 25 °C nach Vorscherung bei 100 bzw. 50 s-1 und anschließendem Sprung der Scherrate auf deutlich niedrigere Werte als Funktion der Zeit verfolgt. Hierbei erhält man bei genügend langer Messdauer (mindestens 200 000-300 000 Schereinheiten) konstante Tropfengrößen. Zum einen handelt es sich dabei um pseudo-stationäre Werte, die nur durch Koaleszenz bestimmt sind, zum anderen um echte stationäre Radien, die durch gleichzeitig ablaufende Koaleszenz und Zerteilung entstehen. Für I liegen die stationären Mittelwerte auf der Zerteilungskurve, für II hingegen auf der Koaleszenzkurve.Der Einfluss eines grenzflächenwirksamen Additivs wurde anhand von I durch Zugabe des Blockcopolymer PIB-b-PDMS zu PIB untersucht. Der Vergleich des zeitlichen Verlaufs von gamma 12 mit der Morphologieentwicklung zeigt, dass das Additiv eine Stabilisierung der feinen Tropfen/Matrix-Struktur des Blends durch Hinderung der Koaleszenz und nicht durch Reduktion der Grenzflächenspannung bewirkt.