984 resultados para DC-DC converters
Resumo:
Self-standing diamond films were grown by DC Arcjet plasma enhanced chemical vapor deposition (CVD). The feed gasses were Ar/H 2/CH 4, in which the flow ratio of CH 4 to H 2 (FCH4/FH2) was varied from 5% to 20%. Two distinct morphologies were observed by scanning electron microscope (SEM), i.e. the pineapple-like morphology and the cauliflower-like morphology. It was found that the morphologies of the as-grown films are strongly dependent on the flow ratio of CH 4 to H 2 in the feed gasses. High resolution transmission electron microscope (HRTEM) survey results revealed that there were nanocrystalline grains within the pineapple-like films whilst there were ultrananocrystalline grains within cauliflower-like films. X-ray diffraction (XRD) results suggested that (110) crystalline plane was the dominant surface in the cauliflower-like films whilst (100) crystalline plane was the dominant surface in the pineapple-like films. Raman spectroscopy revealed that nanostructured carbon features could be observed in both types of films. Plasma diagnosis was carried out in order to understand the morphology dependent growth mechanism. It could be concluded that the film morphology was strongly influenced by the density of gas phases. The gradient of C2 radical was found to be different along the growth direction under the different growth conditions. © 2012 Elsevier B.V. All rights reserved.
Resumo:
2000 Mathematics Subject Classification: 90C48, 49N15, 90C25
Resumo:
Although maximum power point tracking (MPPT) is crucial in the design of a wind power generation system, the necessary control strategies should also be considered for conditions that require a power reduction, called de-loading in this paper. A coordinated control scheme for a proposed current source converter (CSC) based DC wind energy conversion system is presented in this paper. This scheme combines coordinated control of the pitch angle, a DC load dumping chopper and the DC/DC converter, to quickly achieve wind farm de-loading. MATLAB/Simulink simulations and experiments are used to validate the purpose and effectiveness of the control scheme, both at the same power level. © 2013 IEEE.
Resumo:
Four-leg dc-ac power converters are widely used for the power grids to manage grid voltage unbalance caused by the interconnection of single-phase or three-phase unbalanced loads. These converters can further be connected in parallel to increase the overall power rating. The control of these converters poses a particular challenge if they are placed far apart with no links between them (e.g., in islanded microgrids). This challenge is studied in this paper with each four-leg converter designed to have improved common current sharing and selective voltage-quality enhancement. The common current sharing, including zero sequence component, is necessary since loads are spread over the microgrid and they are hence the common responsibility of all converters. The voltage-quality enhancement consideration should however be more selective since different loads have different sensitivity levels towards voltage disturbances. Converters connected to the more sensitive load buses should therefore be selectively triggered for compensation when voltage unbalances at their protected buses exceed the predefined thresholds. The proposed scheme is therefore different from conventional centralized schemes protecting only a common bus. Simulation and experimental results obtained have verified the effectiveness of the proposed scheme when applied to a four-wire islanded microgrid.
Resumo:
System efficiency and cost effectiveness are of critical importance for photovoltaic (PV) systems. This paper addresses the two issues by developing a novel three-port dc-dc converter for stand-alone PV systems, based on an improved Flyback-Forward topology. It provides a compact single-unit solution with a combined feature of optimized maximum power point tracking (MPPT), high step-up ratio, galvanic isolation, and multiple operating modes for domestic and aerospace applications. A theoretical analysis is conducted to analyze the operating modes followed by simulation and experimental work. This paper is focused on a comprehensive modulation strategy utilizing both PWM and phase-shifted control that satisfies the requirement of PV power systems to achieve MPPT and output voltage regulation. A 250-W converter was designed and prototyped to provide experimental verification in term of system integration and high conversion efficiency.
Resumo:
High-volume capacitance is required to buffer the power difference between the input and output ports in single-phase grid-connected photovoltaic inverters, which become an obstacle to high system efficiency and long device lifetime. Furthermore, total harmonic distortion becomes serious when the system runs into low power level. In this study, a comprehensive analysis is introduced for two-stage topology with the consideration of active power, DC-link (DCL) voltage, ripple and capacitance. This study proposed a comprehensive DCL voltage control strategy to minimise the DCL capacitance while maintaining a normal system operation. Furthermore, the proposed control strategy is flexible to be integrated with the pulse-skipping control that significantly improves the power quality at light power conditions. Since the proposed control strategy needs to vary DCL voltage, an active protection scheme is also introduced to prevent any voltage violation across the DCL. The proposed control strategy is evaluated by both simulation and experiments, whose results confirm the system effectiveness.
Resumo:
Modern power networks incorporate communications and information technology infrastructure into the electrical power system to create a smart grid in terms of control and operation. The smart grid enables real-time communication and control between consumers and utility companies allowing suppliers to optimize energy usage based on price preference and system technical issues. The smart grid design aims to provide overall power system monitoring, create protection and control strategies to maintain system performance, stability and security. This dissertation contributed to the development of a unique and novel smart grid test-bed laboratory with integrated monitoring, protection and control systems. This test-bed was used as a platform to test the smart grid operational ideas developed here. The implementation of this system in the real-time software creates an environment for studying, implementing and verifying novel control and protection schemes developed in this dissertation. Phasor measurement techniques were developed using the available Data Acquisition (DAQ) devices in order to monitor all points in the power system in real time. This provides a practical view of system parameter changes, system abnormal conditions and its stability and security information system. These developments provide valuable measurements for technical power system operators in the energy control centers. Phasor Measurement technology is an excellent solution for improving system planning, operation and energy trading in addition to enabling advanced applications in Wide Area Monitoring, Protection and Control (WAMPAC). Moreover, a virtual protection system was developed and implemented in the smart grid laboratory with integrated functionality for wide area applications. Experiments and procedures were developed in the system in order to detect the system abnormal conditions and apply proper remedies to heal the system. A design for DC microgrid was developed to integrate it to the AC system with appropriate control capability. This system represents realistic hybrid AC/DC microgrids connectivity to the AC side to study the use of such architecture in system operation to help remedy system abnormal conditions. In addition, this dissertation explored the challenges and feasibility of the implementation of real-time system analysis features in order to monitor the system security and stability measures. These indices are measured experimentally during the operation of the developed hybrid AC/DC microgrids. Furthermore, a real-time optimal power flow system was implemented to optimally manage the power sharing between AC generators and DC side resources. A study relating to real-time energy management algorithm in hybrid microgrids was performed to evaluate the effects of using energy storage resources and their use in mitigating heavy load impacts on system stability and operational security.
Resumo:
This project is funded by European Research Council in FP7; grant no 259328, 2010 and EPSRC grant no EP/K006428/1, 2013.
Resumo:
This project is funded by European Research Council in FP7; grant no 259328, 2010 and EPSRC grant no EP/K006428/1, 2013.
Resumo:
This work was supported by the Engineering and Physical Sciences Research Council [grant number EP/K006428/1]; and the European Regional Development Fund [grant number LUPS/ERDF/2010/4/1/0164].
Resumo:
ACKNOWLEDGMENT We are thankful to RTE for financial support of this project.
Resumo:
A Depressão na infância e adolescência, tal como na população adulta, é uma das perturbações mentais mais comuns. Uma vez que o seu aparecimento nestas faixas etárias conduz a graves consequências na idade adulta, é fundamental identificar os sintomas depressivos precocemente. Desta forma, os instrumentos de autorrelato têm um papel fundamental, uma vez que permitem com facilidade, de forma fidedigna e válida, ter acesso a formas de pensar, sentir e agir dos sujeitos. O objetivo do presente trabalho consistiu na tradução, adaptação e estudo da Center for Epidemiological Studies Depression Scale for Children (CES-DC) (Weissman, Orvash & Padian, 1980) para os adolescentes portugueses. A amostra é constituÃda por 417 adolescentes, com idades compreendidas entre os 12 e os 18 anos a frequentar o 3º ciclo do ensino básio e ensino secundário. Para o estudo da validade convergente e divergente da CES-DC, foram utilizados a Depression Anxiety Stress Scales (DASS 21) (Lovibond & Lovibond, 1995), o Children's Depresssion Inventory (CID) (Marujo, 1994) e a Students' Life Satisfaction Scale (SLSS) (Marques, Pais-Ribeiro & Lopez, 2007) que avaliam, respetivamente, os estados emocionais negativos (depressão, ansiedade e stress), a sintomatologia depressiva e a satisfação global com a vida. Os resultados obtidos mostram que a escala possui uma boa consistência interna, uma estabilidade temporal adequada, assim como uma boa validade. Sugerem, ainda, tratar-se de uma escala tridimensional: fator humor, fator interpessoal e fator felicidade. Estes dados permitem o avanço da Psicologia, no que diz respeito à avaliação e prática clÃnica com adolescentes. A utilidade do questionário deve ser verificada noutras faixas etárias, principalmente, nas de menos de 12 anos de idade, e também numa amostra clÃnica. Não obstante as limitações apontadas, os resultados sugerem que a CES-DC é um questionário útil na avaliação de sintomas depressivos nos adolescentes. / Depression in children and adolescents, as well as in adults, is one of the most common mental disorders. Since its appearance in these age groups leads to serious consequences in adulthood, it is critical to identify depressive symptoms in early stages. Therefore, self-report instruments play a key role in this contexto since they allow to easily, reliably and validly have access to ways the subject thinks, feels and acts. The aim of this study was to translate, adapt and study the Center for Epidemiological Studies Depression Scale for Children (CES-DC) (Weissman, Orvash & Padian, 1980) for portuguese adolescents. The sample consists of 417 adolescents, aged between 12 and 18 years old, attending the 3rd cycle of basic education and secondary education schools. To study the convergent and divergent validity of the CES-DC, the Depression Anxiety Stress Scales (DASS 21) (Lovibond & Lovibond, 1995) was used, along with the Children's depression Inventory (CDI) (Sailor, 1994) and the Students' Life Satisfaction Scale (SLSS) (Marques, Pais-Ribeiro & Lopez, 2007) that evaluate, respectively, the negative emotional states (depression, anxiety and stress), depressive symptoms and overall satisfaction with life. The results show that the evaluated scale presents a good internal consistency, an adequate temporal stability as well as good validity. They also suggest that this is a three-dimensional scale: humor factor, interpersonal factor and happiness factor. These data allow for the progress of psychology, regarding the assessment and clinical practice among adolescents. The usefulness of the questionnaire should be verified in other age groups, especially in children with less than 12 years old and in a clinical sample. Despite these limitations, the results suggest that CES-DC is useful in the assessment questionnaire of depressive symptoms in adolescents.
Resumo:
v. 13, n. 2, p. 82-92, 2016.