973 resultados para Cost comparison
Resumo:
OBJECTIVE: This study was performed to observe the number of pacemakers that had never been reprogrammed after implantation, and the effect of optimised output programming on estimated longevity of pulse generators in patients with pacemaker METHODS: Sixty patients with Teletronics Reflex pacemakers were evaluated in a pacemaker clinic, from the time of the beginning of its activities, in June 1998, until March 1999. Telemetry was performed during the first clinic visit, and we observed how many pulse generators retained nominal output settings of the manufactures indicating the absence of reprogramming until that date. After evaluation of the capture threshold, reprogramming of pacemakers was performed with a safety margin of 2 to 2.5:1, and we compared the estimated longevity based on battery current at the manufacturer's settings with that based on settings achieved after reprogramming. RESULTS: In 95% of the cases, the original programmed setting was never reprogrammed before the patients attended the pacemaker clinic. Reprogramming the pacemaker prolonged estimated pulse generator life by 19.7±15.6 months (35.5%). CONCLUSION: The majority of the pacemakers evaluated had never been reprogrammed. Estimated pulse generator longevity can be prolonged significantly, using this simple, safe, efficacious, and cost-effective procedure.
Resumo:
OBJECTIVE: Our aim was to compare, in a non randomized study, the surgical outcome in elderly patients with mechanical (Group 1; n=83) and bioprosthetic valve implants (Group 2; n=136). METHODS: During a three year period, 219 patients >75 years underwent Aortic Valve Replacement. The groups matched according to age, sex, comorbidity, valve pathology and concomitant Coronary Artery Bypass Surgery. Follow-up was a total of 469 patient-years (mean follow-up 2.1 years, maximum 4,4 years). RESULTS: Operative mortality was zero and the overall early mortality was 2.3 % (within 30 days). Actuarial survival was 87.5 ± 4.0% and 66.1 ± 7.7% (NS) at 4 years in Group 1 and Group 2, respectively. Freedom from valve-related death was 88.9 ± 3.8% in Group 1 and 69.9±7.9% (NS) in Group 2 at 4 years. CONCLUSION: Aortic Valve Replacement in the elderly (>75 years) is a safe procedure even in cases where concomitant coronary artery revascularization is performed. Only a few anticoagulant-related complications were reported and this may indicate that selected groups of elderly patients with significant life expectancy may benefit from mechanical implants .
Resumo:
The last four decades have seen a dramatic increase in the number of women entering employment. This is particularly true in Europe and although more European women are working outside the home, the patterns of female employment have changed very little. An analysis of these patterns is presented. It was found that women continue to dominate specific fields, particularly teaching and service providing. An investigation of the interpersonal behavior differences among 117 American women from the southeastern United States in three work roles--homemakers, women in traditional occupations, and in nontraditional occupations--was conducted and the sex-role orientation, attitudes toward success, and demographic indicators were examined in order to consider the interplay of these variables with female occupational role and interpersonal behavior. A second focus of the study is on the cross-cultural comparison of the psychological and work variables in women of two different cultures: America and Portugal. Thirty-one Portuguese women were a preliminary comparison sample. The American results showed significant differences between groups in self-perceived interpersonal behaviors and the findings contradicted current stereotypes. The cross-cultural data, although preliminary, indicates differences between the countries in social desirability, aggressive and assertive behaviors, and in sex-role attitudes, which seem to reflect the different stages of economic development. (MKA)
Resumo:
OBJECTIVE: To verify the possible role of adventitial inflammation in atherosclerotic plaque vulnerability and coronary artery remodelling. METHODS: We compared the mean numbers of lymphocytes in the adventitia and in the plaque of ruptured thrombosed and stable equi-stenotic coronary segments of 34 patients who died due to acute myocardial infarction. We also analysed adventitial microvessels, adventitial fibrosis and the external elastic membrane. RESULTS: In the adventitia, the numbers of lymphocytes and microvessels/mm² were 69.5±88.3 and 60.9± 32.1 in culprit lesions and 16.4 ± 21.1 and 44.3±16.1 in stable lesions (p<0.05); within the plaques, the mean number of lymphocytes was 24±40.8 in culprit lesions and 10.9±13.2 in stable ones (p=0.17). The mean percent area of adventitial fibrosis/cross-sectional area of the vessel was significantly lower in unstable plaques (p<0.001). The confocal images showed holes in the external elastic membrane. CONCLUSION: Unstable plaques exhibit chronic pan-arteritis, accompanied by enlargement, medial thinning, and less fibrosis than in stable lesions, which is compatible with vessel aneurysm. Adventitial inflammation may contribute significantly to atheroma instability.
Resumo:
OBJECTIVE: To evaluate the influences of circadian variations on tilt-table testing (TTT) results by comparing the positivity rate of the test performed during the morning with that of the test performed in the afternoon and to evaluate the reproducibility of the results in different periods of the day. METHODS: One hundred twenty-three patients with recurrent unexplained syncope or near-syncope referred for TTT were randomized into 2 groups. In group I, 68 patients, TTT was performed first in the afternoon and then in the morning. In group II, 55 patients, the test was performed first in the morning and then in the afternoon. RESULTS: The TTT protocol was the prolonged passive test, without drug sensitization. Twenty-nine (23.5%) patients had a positive result in at least one of the periods. The positivity rate for each period was similar: 20 (16.2%) patients in the afternoon and 19 (15.4%) in the morning (p=1.000). Total reproducibility (positive/positive and negative/negative) was observed in 49 (89%) patients in group I and in 55 (81%) in group II. Reproducibility of the results was obtained in 94 (90.4%) patients with first negative tests but in 10 (34%) patients with first positive tests. CONCLUSION: TTT could be performed during any period of the day, and even in the 2 periods to enhance positivity. Considering the low reproducibility rate of the positive tests, serial TTT to evaluate therapeutic efficacy should be performed during the same period of the day.
Resumo:
OBJECTIVE: To assess the differences between young males and females after acute myocardial infarction. METHODS: We retrospectively studied 236 patients (54 females and 182 males) after acute myocardial infarction and during hospital stay assessed the following parameters: risk factors; the treatment used; the pattern of coronary artery obstruction; left ventricular ejection fraction; complications; and, using a logistic regression model, the factors related to the occurrence of reinfarction and death. RESULTS: No significant difference was observed between the sexes in risk factors, pattern of coronary artery obstruction, and left ventricular function. The time interval between symptom onset and treatment was longer in females (p=0.03), who underwent thrombolysis (p=0.01) and angioplasty (p=0.03) less frequently than males did, but not myocardial revascularization. Female sex (OR = 5.98) and diabetes (OR = 14.52) were independent factors related to the occurrence of reinfarction and death. CONCLUSION: Young males and females after acute myocardial infarction did not differ in coronary risk factors, and clinical and hemodynamic characteristics. Females had their treatment started later, and they underwent chemical thrombolysis and angioplasty less frequently than males did. Female sex and diabetes were related to the occurrence of reinfarction and death.
Resumo:
OBJECTIVE: To study the differences between fluvastatin and pravastatin regarding LDL susceptibility to oxidation, plasma levels of total cholesterol (TC), HDL-C, LDL-C and triglycerides (TG) in hypercholesterolemic patients with established coronary heart disease (CHD). METHODS: A double-blind randomized parallel study was conducted that included 41 hypercholesterolemic outpatients with CHD treated at the Instituto de Cardiologia do Rio Grande do Sul. The inclusion criteria were LDL-C above 100 mg/dL and triglycerides below 400 mg/dL based on 2 measures. After 4 weeks on a low cholesterol diet, those patients that fullfilled the inclusion criteria were randomized into 2 groups: the fluvastatin group (fluvastatin 40 mg/day) and the pravastatin group (pravastatin 20 mg/day), for 24 weeks of treatment. LDL susceptibility to oxidation was analyzed with copper-induced production of conjugated dienes (Cu2+) and water-soluble free radical initiator azo-bis (2'-2'amidinopropanil) HCl (AAPH). Spectroscopy nuclear magnetic resonance was used for determination of lipids. RESULTS: After 24 weeks of drug therapy, fluvastatin and pravastatin significantly reduced LDL susceptibility to oxidation as demonstrated by the reduced rate of oxidation (azo and Cu) and by prolonged azo-induced lag time (azo lag). The TC, LDL-C, and TG reduced significantly and HDL-C increased significantly. No differences between the drugs were observed. CONCLUSION: In hypercholesterolemic patients with CHD, both fluvastatin and pravastatin reduced LDL susceptibility to oxidation.
Resumo:
OBJECTIVE: To assess the in-hospital results and clinical follow-up of young patients (< 50 years) with multivessel coronary artery disease undergoing stent implantation in native coronary arteries and to compare their results with those of patients with single-vessel coronary artery disease. METHODS: We retrospectively studied 462 patients undergoing coronary stent implantation. Patients were divided into 2 groups: group I (G-I) - 388 (84%) patients with single-vessel coronary artery disease; and group II (G-II) - 74 (16%) patients with multivessel coronary artery disease. RESULTS: The mean age of the patients was 45±4.9 years, and the clinical findings at presentation and demographic data were similar in both groups. The rate of clinical success was 95% in G-I and 95.8% in G-II (P=0.96), with no difference in regard to in-hospital evolution between the groups. Death, acute myocardial infarction, and the need for myocardial revascularization during clinical follow-up occurred in 10.1% and 11.2% (P=0.92) in G-I and G-II, respectively. By the end of 24 months, the actuarial analysis showed an event-free survival of 84.6 % in G-I and 81.1% in G-II (P=0.57). CONCLUSION: Percutaneous treatment with coronary stent implantation in young patients with multivessel disease may be safe with a high rate of clinical success, a low incidence of in-hospital complications, and a favorable evolution in clinical follow-up.
Resumo:
The objective of this thesis is to compare and contrast environmental licensing systems, for the wood panel industry, in a number of countries in order to determine which system is the best from an environmental and economic point of view. The thesis also examines the impact which government can have on industry and the type of licensing system in operation in a country. Initially, the thesis investigates the origins of the various environmental licensing systems which are in operation in Ireland, Scotland, Wales, France, USA and Canada. It then examines the Environmental Agencies which control and supervise industry in these countries. The impact which the type of government (i.e. unitary or federal) in charge in any particular country has on industry and the Regulatory Agency in that country is then described. Most of the mills in the thesis make a product called OSB (Oriented Strand Board) and the manufacturing process is briefly described in order to understand where the various emissions are generated. The main body of the thesis examines a number of environmental parameters which have emission limit values in the licenses examined, although not all of these parameters have emission limit values in all of the licenses. All of these parameters are used as indicators of the potential impact which the mill can have on the environment. They have been set at specific levels by the Environmental Agencies in the individual countries to control the impact of the mill. Following on from this, the two main types of air pollution control equipment (WESPs and RTOs) are described in regard to their function and capabilities. The mill licenses are then presented in the form of results tables which compare air results and water results separately. This is due to the fact that the most significant emission from this type of industry is to air. A matrix system is used to compare the licenses so that the comparison can be as objective as possible. The discussion examines all of the elements previously described and from this it was concluded that the IPC licensing system is the best from an environmental and economic point of view. It is a much more expensive system to operate than the other systems examined, but it is much more comprehensive and looks at the mill as a whole rather than fragmenting it. It was also seen that the type of environmental licensing system which is in place in a country can play a role in the locating of an industry as certain systems were seen to have more stringent standards attached to them. The type of standard in place in a country is in turn influenced by the type of government which is in place in that country.
Resumo:
Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.
Resumo:
Background: Postprandial Lipemia (PPL) is a physiological process that reflects the ability of the body to metabolize lipids. Even though the influence of oral contraceptives (OC) on PPL is not known, it is a known fact that their use increases fasting lipid values. Objective: To compare the PPL between women who are on OC and those who are not. Methods: A prospective analytical study which assessed eutrophic women, aged between 18 and 28 years old, who were irregularly active and with fasting triglycerides ≤150 mg/dL. They were divided into two groups: oral contraceptive group (COG) and non-oral contraceptive group (NCOG). Volunteers were submitted to the PPL test, in which blood samples were collected in time 0 (12-hour fasting) and after the intake of lipids in times 180 and 240 minutes. In order to compare the triglyceride deltas, which reflect PPL, the two-tailed Mann-Whitney test was used for independent samples between fasting collections and 180 minutes (Δ1) and between fasting and 240 minutes (Δ2). Results: Forty women were assessed and equally divided between groups. In the fasting lipid profile, it was observed that HDL did not present significant differences and that triglycerides in COG were twice as high in comparison to NCOG. Medians of Δ1 and Δ2 presented significant differences in both comparisons (p ≤0.05). Conclusion: The results point out that women who are irregularly active and use OC present more PPL in relation to those who do not use OC, which suggests that in this population, its chronic use increases the risk of heart conditions.
Resumo:
Background:Cardiovascular diseases (CVDs) are the leading cause of death worldwide. Knowledge about cardiovascular risk factors (CVRFs) in young adults and their modification over time are measures that change the risks and prevent CVDs.Objectives:To determine the presence of CVRFs and their changes in different health care professionals over a period of 20 years.Methods:All students of medicine, nursing, nutrition, odontology, and pharmacy departments of Federal University of Goiás who agreed to participate in this study were evaluated when they started their degree courses and 20 years afterward. Questionnaires on CVRFs [systemic arterial hypertension (SAH), diabetes mellitus, dyslipidemia, and family history of early CVD, smoking, alcohol consumption, and sedentarism] were administered. Cholesterol levels, blood sugar levels, blood pressure, weight, height, and body mass index were determined. The Kolmogorov-Smirnov test was used to evaluate distribution, the chi-square test was used to compare different courses and sexes, and the McNemar test was used for comparing CVRFs. The significance level was set at a p value of < 0.05.Results:The first stage of the study included 281 individuals (91% of all the students), of which 62.9% were women; the mean age was 19.7 years. In the second stage, 215 subjects were reassessed (76% of the initial sample), of which 59.07% were women; the mean age was 39.8 years. The sample mostly consisted of medical students (with a predominance of men), followed by nursing, nutrition, and pharmacy students, with a predominance of women (p < 0.05). Excessive weight gain, SAH, and dyslipidemia were observed among physicians and dentists (p < 0.05). Excessive weight gain and SAH and a reduction in sedentarism (p < 0.05) were observed among pharmacists. Among nurses there was an increase in excessive weight and alcohol consumption (p < 0.05). Finally, nutritionists showed an increase in dyslipidemia (p < 0.05).Conclusion:In general, there was an unfavorable progression of CVRFs in the population under study, despite it having adequate specialized knowledge about these risk factors.
Resumo:
Background: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. Objectives: We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. Methods: The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 ± 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. Results: At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. Conclusions: In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques.