931 resultados para Conversational routine


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transgenic animals with improved qualities have the potential to upset the ecological balance of a natural environment. We investigated metabolic rates of 'all-fish' growth hormone (GH) transgenic common carp under routine conditions and during starvation periods to determine whether energy stores in transgenic fish would deplete faster than controls during natural periods of starvation. Before the oxygen uptake was measured, the mean daily feed intake of transgenic carp was 2.12 times greater than control fish during 4 days of feeding. The average oxygen uptake of GH transgenic fish was 1.32 times greater than control fish within 96 h of starvation, but was not significantly different from controls between 96 and 144 h of starvation. At the same time, GH transgenic fish did not deplete energy reserves at a faster rate than did the controls, as the carcass energy contents of the two groups following a 60-d starvation period were not significantly different. Consequently, we suggest that increased routine oxygen uptake in GH transgenic common carp over that of control fish may be mainly due to the effects of feeding, and not to an increase in basal metabolism. GH transgenic fish are similar to controls in the regulation of metabolism to normally distribute energy reserves during starvation. (c) 2008 Published by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dynamics of planktonic cyanobacteria in eutrophicated freshwaters play an important role in formation of annual summer blooms, yet overwintering mechanisms of these water bloom forming cyanobacteria remain unknown. The responses to darkness and low temperature of three strains (unicellular Microcystis aeruginosa FACHB-905, colonial M. aeruginosa FACHB-938, and a green alga Scenedesmus quadricauda FACHB-45) were investigated in the present study. After a 30-day incubation under darkness and low temperature, cell morphology, cell numbers, chlorophyll a, photosynthetic activity (ETRmax and I-k), and malodialdehyde (MDA) content exhibited significant changes in Scenedesmus. In contrast, Microcystis aeruginosa cells did not change markedly in morphology, chlorophyll a, photosynthetic activity, and MDA content. The stress caused by low temperature and darkness resulted in an increase of the antioxidative enzyme-catalase (CAT) in all three strains. When the three strains re-grew under routine cultivated condition subjected to darkness and low temperature, specific growth rate of Scenedesmus was lower than that of Microcystis. Flow cytometry (FCM) examination indicated that two distinct types of metabolic response to darkness and low temperature existed in the three strains. The results from the present study reveal that the cyanobacterium Microcystis, especially colonial Microcystis, has greater endurance and adaptation ability to the stress of darkness and low temperature than the green alga Scenedesmus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Systematic investigations into the temporal and spatial distribution, composition and abundance of protozoa in two regions with different trophic levels in Chaohu Lake, a large, shallow and highly eutrophic freshwater lake in China, were conducted during 2002-2003. A total of 114 species of protozoa, including phytomastigophorans, zoomastigophorans, amoebae and ciliates, were identified from 120 polyurethane foam unit (PFU) samples exposed at four stations and from various types of natural substrates. Of the 114 taxa, 36 core species were found on PFU substrates and 23 of these were found on natural ones. Protozoan abundance and chemical physical parameters at nine sampling stations, four in the western lake and five in the eastern part, indicate trophic gradient changes along the lake. Seasonal variations in the species composition of major groups at littoral PFU sampling stations illustrate the effect of a severe algal bloom on the protozoan community structure. Temporal and spatial distributions of individual abundance as functions of water temperature and trophic status were revealed. This study demonstrates again that the PFU artificial substrate method samples protozoan communities more effectively than routine natural substrate methods. (c) 2005 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The H4IIE rat hepatoma cell line was employed as a cell model to screen 7-ethoxyresorufin O-deethylase (EROD)-TCDD equivalents (EROD-TEQ) of human breast milk samples collected from Hong Kong and Guangzhou, China. The screening methods employed a 96-well plate spectrofluorometer-EROD assay. For cell-line validation, our results demonstrated a dose-dependent increase in the Ah receptor-mediated response (i.e., CYP1A1 mRNA and EROD) of the cells upon exposure to a number of known Ah receptor agonists, including 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), 2,3,7,8-tetrachlorodibenzothiophene, benzo[a]pyrene, and beta-naphthaflavone. TCDD induced CYP1A1 mRNA and EROD was in a close positive correlation (r = 0.98). For the screening of dioxin-like compounds, breast milk samples collected during lactation weeks 3-5 were used. One hundred (from Hong Kong) and 48 (from Guangzhou) breast milk samples were assayed, of which 65% and 68% of the samples, respectively, showed detectable dioxin-like activities using the H4IIE cell EROD screening method. For sixty-five samples from Hong Kong the mean EROD-TEQ values ranged from 58.1 to 96.5 pg/g of milk fat for those aged 21-36 years while 32 samples from Guangzhou had mean values of 98.8-202.1 pg/g of milk fat. In comparisons of the EROD-TEQ values for different age groups from both cities, there were no significant differences (P < 0.05). However, the mean and median EROD-TEQ values of the Guangzhou population were in general higher than those of the Hong Kong population. The results of the present study indicate that it is feasible to use the H4IIE cell-line as a model for screening dioxin-like compounds in human breast milk. In addition, the method is rapid and cost-effective, particularly for a routine and high-throughput sample screening analysis, compared to the costly and time-intensive chemical analytical techniques. (C) 2003 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e mu A of Xe-129(43+), 22 e mu A of Bi-209(41+), and 1.5 e mu A of Bi-209(50+). To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e mu A of Xe-129(27+) and 152 e mu A of Xe-129(30+), although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and Xe-129(27+), Kr-78(19+), Bi-209(31+), and Ni-58(19+) beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production. Finally the future development of SECRAL will be presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The traditional design of accelerator magnet usually involves many time consuming iterations of the manual analysis process. A software platform to do these iterations automatically is proposed in this paper. In this platform, we use DAKOTA (a open source software developed by Sandia National Laboratories) as the optimizing routine, which provides a variety of optimization methods and algorithms, and OPERA (software from Vector Fields) is selected as the electromagnetic simulating routine. In this paper, two examples of designs of accelerator magnets are used to illustrate how an optimization algorithm is chosen and the platform works.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the method for the derivatization of carbohydrates with 1-phenyl-3-methyl-5-pyrazolone (PMP) was simplified. One-third of the derivatization time was saved. Five monosaccharide derivatives have been well separated by MEKC and HPLC under optimized conditions. Good reproducibility could be obtained with relative standard deviation (RSD) values of the migration times within 5.0 and 2.3%, respectively. Furthermore, the developed methods have been successfully applied to the analysis of carbohydrates in Aloe powder and food. These methods are quite useful for routine analysis of monosaccharides and oligosaccharides in real samples. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We described here a new method for the determination of total calcium in plasma. The method is based on the precipitation of calcium with excess oxalate and the measurement of residual oxalate by flow injection analysis with Ru(bpy)(3)(2+) electrochemiluminescent detection. It has the advantages of extremely stable reagent, user-friendly instrument, high selectivity, good analytical recovery, wide dynamic range, and nice correlation with atomic absorption spectroscopy. The calibration plot for calcium is linear over a concentration range from 0.5 mmol L-1 to 4.8 mmol L-1, which is wider than those obtained by most other methods. The analytical recoveries for plasma calcium are 98.4-101.2% with coefficients of variation (CVs) of 1.96-2.52%. The within-day CVs range from 0.76% to 0.95%, and between-day CVs were from 1.12% to 1.46%. The time for each injection is one minute. Because the proposed method can be readily carried out on increasingly popular instruments for Ru(bpy)(3)(2+) ECL immunoassays and DNA probe assays, Ru(bpy)32+ ECL method is suitable for routine clinical analysis of calcium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The design and performance of a miniaturized chip-type tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] electrochemiluminescence (ECL) detection cell suitable for both capillary electrophoresis (CE) and flow injection (FI) analysis are described. The cell was fabricated from two pieces of glass (20 x 15 x 1.7 mm), and the 0.5-mm-diameter platinum disk was used as working electrode held at +1.15 V (vs silver wire quasi-reference), the stainless steel guide tubing as counter electrode, and the silver wire as quasi-reference electrode. The performance traits of the cell in both CE and FI modes were evaluated using tripropylamine, proline, and oxalate and compared favorably to those reported for CE and FI detection cells. The advantages of versatility, sensitivity, and accuracy make the device attractive for the routine analysis of amine-containing species or oxalate by CE and FI with Ru(bPY)(3)(2divided by) ECL detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

More than 22 000 folding kinetic simulations were performed to study the temperature dependence of the distribution of first passage time (FPT) for the folding of an all-atom Go-like model of the second beta-hairpin fragment of protein G. We find that the mean FPT (MFPT) for folding has a U (or V)-shaped dependence on the temperature with a minimum at a characteristic optimal folding temperature T-opt*. The optimal folding temperature T-opt* is located between the thermodynamic folding transition temperature and the solidification temperature based on the Lindemann criterion for the solid. Both the T-opt* and the MFPT decrease when the energy bias gap against nonnative contacts increases. The high-order moments are nearly constant when the temperature is higher than T-opt* and start to diverge when the temperature is lower than T-opt*. The distribution of FPT is close to a log-normal-like distribution at T* greater than or equal to T-opt*. At even lower temperatures, the distribution starts to develop long power-law-like tails, indicating the non-self-averaging intermittent behavior of the folding dynamics. It is demonstrated that the distribution of FPT can also be calculated reliably from the derivative of the fraction not folded (or fraction folded), a measurable quantity by routine ensemble-averaged experimental techniques at dilute protein concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present study, curcumin from Chinese herbal medicine turmeric was determined by capillary electrophoresis with amperometric detection (CE-AD) pretreated by a self-designed, simple, inexpensive solid-phase extraction (SPE) cartridge based on the material of tributyl phosphate resin. An average concentration factor of 9 with the recovery of >80% was achieved when applied to the analysis of curcumin in extracts of turmeric. Under the optimized CE-AD conditions: a running buffer composed of 15 mM phosphate buffer at a pH 9.7, separation voltage at 16 W, injection for 6 s at 9 W and detection at 1.20 V, CE-AD with SPE exhibited low detection limit as 3 - 10(-8) mol/l (SIN = 3), high efficiency of 1.0(.)10(5) N, linear range of 7(.)10(-4) -3(.)10(-6) mol/l (r = 0.9986) for curcumin extracted from light petroleum. The method developed resulted in enhancement of the detection sensitivity and reduction of interference from sample matrix in complicated samples and exhibited the potential application for routine analysis, especially in food, because a relatively complete process of sample treatment and analysis was described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using a recently developed laser light-scattering (LLS) procedure, we accomplished the characterization of a broadly distributed unfractionated phenolphthalein poly(aryl ether ketone) (PEK-C) in CHCl3 at 25 degrees C. The laplace inversion of precisely measured intensity-intensity time correlation function from dynamic LLS leads us first to an estimate of the characteristic line-width distribution G(Gamma) and then to the translational diffusion coefficient distribution G(D). By using a previously established calibration of D (cm(2)/s) = 2.37 X 10(-4)M(-0.57), were able to convert G(D) into a differential weight distribution f(w)(M). The weight-average molecular weight M(w) calculated from f(w)(M) agrees well with that directly measured in static LLS. Our results indicate that both the calibration and LLS procedure used in this study are ready to be applied as a routine method for the characterization of the molecular weight distribution of PEK-C. (C) 1996 John Wiley & Sons, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel Eastman-AQ/Ni(II) chemically modified electrode (CME) produced by "double coating step" deposition of a poly(ester sulphonic acid) polymer film and Ni2+-containing crystalline species onto glassy carbon instead of a metallic nickel electrode exhibited stable electrocatalytic oxidation of numerous alpha-hydrogen compounds including carbohydrates, amines and amino acids. In cyclic voltammetry, the electrocatalysis appeared with an irreversible anodic wave at +0.55 V (vs. Ag/AgCl). The CME was adapted for constant-potential amperometric detection of these compounds in flow injection analysis. Using the CME, the linear response concentration range was between 1.0 x 10(-5) and 5.0 x 10(-2) mol/l and the detection limit was 5.0 x 10(-6) mol/l for glucose. The stability of the CME was adequate for routine quantitative application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Barcodes based on mitochondrial cytochrome oxidase (mtDNA CO1) sequences are being used for broad taxonomic groups of animals with demonstrated success in species identification and cryptic species discovery, but it has become clear that complementation by a nuclear marker system is necessary, in particular for the barcoding of plants. Here, we propose the nuclear internal transcribed spacer (ITS) as a potentially usable and complementary marker for species identification of red macroalgae, as well as present a primary workflow for species barcoding. Data show that for most red macroalgal genera (except members of the family Delesseriaceae), the size of ITS region ranges from 600 to 1200 bp, and contains enough variation to generate unique identifiers at either the species or genus levels. Consistent with previous studies, we found that the ITS sequence can resolve closely related species with the same fidelity as mtDNA CO1. Significantly, we confirmed that length polymorphism in the ITS region (including 5.8S rRNA gene) can be utilized as a character to discriminate red macroalgal species. As a complementary marker, the verifiable nuclear ITS region can speed routine identification and the detection of species, advance ecological and taxonomic inquiry, and permit rapid and accurate analysis of red macroalgae.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple method was developed for extracting DNA from brown algae Laminaria japonica, which possess large amounts of acidic polysaccharides. Firstly, the sporophyte were washed by eliminating polysaccaride buffer to remove the polysaccharides and then ground in liquid nitrogen. Secondly, the powders were treated with lysing buffer. Thirdly, KAc was used to eliminate the remaining acidic polysaccharides. The extracted DNA was purified using a chloroform-isoamyl alcohol ( 24: 1 v/v), and precipitated in cold isopropanol. The yield was from 18.7 to 37.5 mu g g(-1) (wet weight) and the purity of total DNA was determined spectrophotometrically as the ratio of A(260)/A(280), which was about 1.7 - 1.9. The extracted DNA was of high quality and suitable for molecular analyses, such as PCR, restriction enzyme digestion. This method is a reproducible, simple, and rapid technique for routine DNA extraction from sporophyte in Laminaria japonica. Furthermore, the low cost of this method makes it attractive for large-scale studies.